| Location: | Kentucky |
|---|---|
| Posted: | May 13, 2026 |
| Due: | Jun 4, 2026 |
| Agency: | State Government of Kentucky |
| Type of Government: | State & Local |
| Category: |
|
| Solicitation No: | RFB-785-2600000593-2 |
| Publication URL: | To access bid details, please log in. |
Description: RFB-270-26 CHFS - WSH-Replace HVAC Piping
Department: Facilities & Support Services
Buyer: Janis Wilhoite
Solicitation Number: RFB-785-2600000593-2
Type: Request for Bids (RFB)
Category: Construction
Closing Date and Time: 06/04/2026 01:30 PM EDT
| Line Number | Commodity Description | Details | Requested | |
|
1
|
***ONLY ONLINE BIDS WILL BE ACCEPTED FOR THIS RFB.***
Emailed and hard copies delivered by any method WILL NOT BE ACCEPTED.
On this line, Bidders must enter $0.00 for Contract Amount in the e-procurement system. Actual Contract Amount must be entered on "Official Bid Document" and submitted as an attachment in the e-procurement system. Vendors should review and update, if necessary, all addresses and contact persons for their account prior to bid submission. This information will carry forward to a contract if awarded, therefore please ensure all information is correct.
** Entire Official Bid Document and Bid Bond (if required) should be combined as one PDF and uploaded**
Project scope entails the furnishing and startup of dedicated outdoor air units and fan coil units to serve 21 individual Patient and Administration Wings/Floors at Western State Hospital. These wings are located within Buildings 55, 56, 57, and 58. Project furnished outdoor air units and fan coil units shall be installed by others in a multi-phase approach. Inspection and factory startup of project furnished outdoor air units and fan coil units shall be provided in this project. This on-site inspection and startup of project furnished equipment shall be performed by a manufacturers representative and shall occur after others have installed the project furnished units and other owner furnished materials such as ductwork, piping, grilles and diffusers, etc.. Controls furnished with project furnished equipment shall be integrated into the building management system by others. Proper storage of all projects furnished equipment is required from the equipment delivery date to the installation date. All project buildings/areas are located within a secure, acute care adult psychiatric facility.
|
Specifications
Commodity Code
912
|
Service From
06/09/2026
Service To
07/09/2027
|
View Purchase History
Additional Information
|

With GovernmentContracts, you can:
...Project: Construction Manager at Risk (CMAR)-Municipal Building Ref. #: 2026-55 Department...: The City ...
City of Bowling Green
Bid Due: 6/22/2026
...Project: Sun Valley Pool Construction Ref. #: RFP260268 Department: Parks & Recreation Type... ...
City of Louisville, Kentucky
Bid Due: 7/09/2026
...No. Type Title Department Close Date Reference #: 2026-55. Name: Construction Manager at ...
City of Bowling Green
Bid Due: 6/22/2026
...Bid Number: 26-026 Bid Title: Construction Inspection Services for KY-17 Corridor Tunnel Category... ...
Northern Kenturky's Sanitation District
Bid Due: 6/30/2026