| Location: | Colorado |
|---|---|
| Posted: | Sep 10, 2025 |
| Due: | Sep 12, 2025 |
| Agency: | DEPT OF DEFENSE |
| Type of Government: | Federal |
| Category: |
|
| Solicitation No: | FA700025Q0GXT |
| Publication URL: | To access bid details, please log in. |
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
Qty 1- GXT Stress Test Machine
- Must have SCIMAGE/PICOM connection capabilities.
- At least a Windows 10 Operating System or newer.
- Set-up, delivery, installation, and user interface training for technician.
- ELI LINK connectivity for SCIMAGE/PICOM connection integration.
- BP monitoring capabilities with SunTech Tango and SpO2
- Full features include:
• Automatic ST segment analysis and trending on all 12 leads.
• Superimposition comparison of current and reference complexes on both a 4x QRS, and updated 12-lead
median complexes.
• Context View during the exam allowing full disclosure review and addition of past ECG events.
• Automatic ventricular ectopic beat detection.
• Up to 100 different exercise protocols.
• Automatic 12-lead ECGs with prompts for manual or automated (optional) blood pressure acquisition.
• Multiple final report formats with custom report sequence capabilities and automated narrative summary.
• Networked export of XML, PDF, HL7, or DICOM® results.
• Networked receipt of XML, HL7, or DICOM orders.
• Archive directories with full disclosure exam data.
• User-defined ST measurement points.
• Analog and TTL output for interface with external devices.
• Programmable and fixed protocols, procedures, and final reports.
• Pre-test electrode impedance check.
• Demonstration mode.
• Automated NIBP and SpO2 readings (with optional device).
• Various text and graphical formats.
• Medications, notes, diagnoses, indications, and procedural comment entries.
• Rate of Perceived Exertion (RPE) entry during test.
• Source Consistency Filter (SCF).
• Beat Consistency Filter (BCF) on ECG printouts.
• METs, maximum predicted heart rate, and target heart rate formula selection.
• Various exercise controls with compatible treadmills, ergometers, and pharmacological studies.
• Ability to select final report segments including Patient Information, Exam Summary, Rate/BP/Workload
Trends, ST Level Trends, ST Slope Trends, Worst Case Average, Periodic Averages, Peak Averages, and
ECG Prints.
• ST level and slope data for lead and worst-case average beat, updated continually during test.
INTRODUCTION27
• Editing of final report in Review phase.
• Paperless workflow capability.
• Ability to store exams and final reports in a centralized database.
• Pre-registration and scheduling of patients.
• Health risk assessment based on Duke and Functional Aerobic Impairment (FAI) algorithms.

With GovernmentContracts, you can:
...analysis that identifies the actual resources required to operate, maintain, and plan for ...
Gunnison County
Bid Due: 7/01/2026