| Location: | Federal |
|---|---|
| Posted: | Feb 6, 2026 |
| Due: | Feb 21, 2026 |
| Agency: | DEPT OF DEFENSE |
| Type of Government: | Federal |
| Category: |
|
| Solicitation No: | F3W3426029A001 |
| Publication URL: | To access bid details, please log in. |
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
1 each three-phase oil transformer in hermetic design according to DIN EN 50588 Loss series AAo/AK with reduced power losses in accordance with the European Commission's Ecodesign Regulation, with zere tolerance, stage 2 from July 1, 2021, with the following specs: High voltage (HV) 20,000 V; Low voltage (LV) 400/230 V; Voltage Tapping 5 steps ± 2x2.5%; Vector Group Dyn5; Frequency 50 Hz; Cooling Method 3. Length approx. 1,340 mm; Width approx. 1,045 mm; Height approx. 1,630 mm; Weight approx. 2,650 kg; Oil weight approx. 490 kg.
Additional accessories:
1 each Transformer protection relay RIS/DMCR/DGPT2
3 each Euromold plug bushings for 250A angle plugs
4 each Transformer connection terminals, four wire, 35-240 mm², for M30x2 feed-through, for terminals 2DIRECT-CL/35-240/4x/L/M30x2 (Pfisterer 331 747 001); clamps for terminal bolts compliant with DIN EN 50386; DIN EN 50386 compliant bolted connections (1 kV). Type tested in compliance with IEC 61238 with Cu cables, 240 mm².
4 each Cover for 2DIREKT Four Wire Terminal, for Bolted Connections M30-M24, Indoor Use (Pfisterer 331 347 001).
4 each additional covers for Screw with Ball Pin.
4 each vibration dampers EK90
60 meters 20 kV cable type N2XSY 1 x 35/RM 16.
The intention is to award to the vendor who is deemed responsible, responsive, and represents the best value to the Government based on selection of the lowest total price that is deemed technically acceptable.
In accordance with FAR 12.201-1 (c) (2) Contracting Officer has chosen to solicit quotations directly from suppliers. When soliciting directly-
(i) Post a presolicitation notice in the GPE according to subpart 5.1, unless an exception in 5.101(b) applies.
(ii) Solicit quotations from at least three sources; and
(iii) Whenever practicable, solicit quotations from two sources not included in the previous solicitation.
In case you are interested in receiving the solicitation please feel free to contact the Primary or the Secondary Point of Contact.

With GovernmentContracts, you can:
...Mountain Region (RMR) is proposing to upgrade 35 miles of its Lusk Rural ...
ENERGY, DEPARTMENT OF
Bid Due: 7/24/2026
...Lusk Rural Tap-Glendo (LRT- GLD) 69-kV transmission line to a 115-kV transmission line ...
ENERGY, DEPARTMENT OF
Bid Due: 7/03/2026
...PROJECT (LIBERTY - LONE BUTTE, LIBERTY - PHOENIX 230-kV TRANSMISSION LINE) Attachments/Links Contact...
ENERGY, DEPARTMENT OF
Bid Due: 6/12/2026
...and Related Structures Construction Place of Performance: Description North Gunnison 115-kV Switch...
ENERGY, DEPARTMENT OF
Bid Due: 7/06/2026