C26-032 Altitude Test Chamber Blower Replacement

Location: Oklahoma
Posted: Aug 4, 2026
Due: Aug 10, 2026
Agency: DEPT OF DEFENSE
Type of Government: Federal
Category:
  • 43 - Pumps and Compressors
Solicitation No: F3YCEB6058A101
Publication URL: To access bid details, please log in.
Follow
C26-032 Altitude Test Chamber Blower Replacement
Active
Contract Opportunity
Notice ID
F3YCEB6058A101
Related Notice
Department/Ind. Agency
DEPT OF DEFENSE
Sub-tier
DEPT OF THE AIR FORCE
Major Command
AIR FORCE MATERIEL COMMAND
Sub Command
AIR FORCE SUSTAINMENT CENTER
Office
FA8125 AFSC PZIMA
Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information View Changes
  • Contract Opportunity Type: Presolicitation (Updated)
  • Updated Published Date: Aug 04, 2026 02:06 pm CDT
  • Original Published Date: Jun 24, 2026 01:06 pm CDT
  • Updated Response Date: Aug 10, 2026 02:00 pm CDT
  • Original Response Date: Jul 01, 2026 03:00 pm CDT
  • Inactive Policy: 15 days after response date
  • Updated Inactive Date: Aug 25, 2026
  • Original Inactive Date: Jul 16, 2026
  • Initiative:
    • None
Classification
  • Original Set Aside: Total Small Business Set-Aside (FAR 19.5)
  • Product Service Code: 4310 - COMPRESSORS AND VACUUM PUMPS
  • NAICS Code:
    • 333912 - Air and Gas Compressor Manufacturing
  • Place of Performance:
    Tinker AFB , OK 73145
    USA
Description View Changes

** THIS IS A PRE-SOLICITATION NOTICE. NO QUOTES WILL BE ACCEPTED UNTIL THE REQUEST FOR QUOTE (RFQ) IS POSTED. **



The 76 CMXG is requesting procurement of one (1) Altitude Test Chamber System Pressurization Blower. The requested equipment item description/specifications are outlined below. This is a BRAND-NAME requirement.




  1. Model Number: Dearing Compressor and Pump Co. Pressure Blower System, Part Number DSP-2505-8CM-6-50 or equal.

  2. Quantity: One (1) each

  3. The replacement unit shall be a direct replacement for the current Pressure Blower System Model 38406A, Serial Number 27335 used in conjunction with the existing Altitude Chamber Test System and shall meet all form, fit, and functions of the original unit.

  4. The new direct replacement Pressure Blower System shall meet all the design requirements of the original Pressure Blower system.

  5. The new replacement blower shall be a centrifugal multistage blower.

  6. The blower operational design criteria shall be inlet air pressure range from 28 inches HgA to 31 HgA, inlet air temperature range from 0 degrees F to 115 degrees F, inlet air design temperature of 80 degrees F, output air volume of 2000 SCFM, and outlet air pressure of 6 psig at 2000 SCFM.

  7. The blower section joints shall be equipped with O-Rings.

  8. The blower shall utilize labyrinth seals.

  9. The new replacement blower shall be equipped with a 100 HP TEFC premium efficient motor with 460 VAC, 3 phase and 60 Hz power requirements, and an operational speed of 3600 rpm.

  10. The motor shall be equipped with a conduit box for connection to the existing facility starter power enclosure.

  11. The new replacement blower and motor shall be skid mounted as a packaged unit.

  12. The skid shall be constructed of I-Beam steel and powder coated.

  13. The blower motor package shall be equipped with all required motor and blower shaft coupling components and rotational safety guards for a complete operational system.

  14. The new direct replacement Pressure Blower system shall connect to the existing Altitude Chamber Test System.

  15. All blower package components shall be new.

  16. Any substitutions shall be responsible for connection to the existing Altitude Chamber Test System and functional testing to ensure form, fit, and function of the Altitude Chamber Test System is maintained.



Contemplated contract details:




  • Firm-fixed price

  • 100% Small Business Set-Aside

  • FSC/PSC: 4310

  • NAICS: 333912

  • Size Standard: 1,000 EMPL



Requirements for Award:




  • System for Award Management (SAM) is required to receive any award. Vendors can register electronically at https://sam.gov/content/home.


Attachments/Links
Contact Information
Contracting Office Address
  • CP 405 734 9107 3001 STAFF DR STE 2S76
  • TINKER AFB , OK 73145-3303
  • USA
Primary Point of Contact
Secondary Point of Contact
History

Related Document

Jun 24, 2026[Presolicitation (Original)] C26-032 Altitude Test Chamber Blower Replacement
Daily notification on new contract opportunities

With GovernmentContracts, you can:

  • Find more opportunities and win more business
  • Receive daily alerts for all new bid opportunities
  • Get contract opportunities matched to your business
ONE WEEK FREE TRIAL

See also

Training Support for Costing Practices and Rate Development for University Research, Core Facilities

Oklahoma State University

Bid Due: 9/03/2026

Follow EWP Nowata County, OK - NS 411 Rd Nowata County, OK -

AGRICULTURE, DEPARTMENT OF

Bid Due: 9/17/2026

Procurement #164857 Title Solicitation 2026-001-050- (11) 3 and 4 Bedroom Homes- New Construction

Cherokee Nation

Bid Due: 9/18/2026

NewsRFQ 3951 Aug 12, 2026 Amendment of Solicitation The bid submission deadline for

Grand River Dam Authority

Bid Due: 9/03/2026

* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.