HASKELL IHS - VESTIBULE DOORS, SIDELIGHTS, AND TRANSOMS REPLACEMENT

Location: Kansas
Posted: Jun 5, 2025
Due: Jul 7, 2025
Agency: HEALTH AND HUMAN SERVICES, DEPARTMENT OF
Type of Government: Federal
Category:
  • Z - Maintenance, Repair or Alteration of Real Property
Solicitation No: IHS1512570
Publication URL: To access bid details, please log in.
Follow
HASKELL IHS - VESTIBULE DOORS, SIDELIGHTS, AND TRANSOMS REPLACEMENT
Active
Contract Opportunity
Notice ID
IHS1512570
Related Notice
IHS1512570
Department/Ind. Agency
HEALTH AND HUMAN SERVICES, DEPARTMENT OF
Sub-tier
INDIAN HEALTH SERVICE
Office
OK CITY AREA INDIAN HEALTH SVC
Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information
  • Contract Opportunity Type: Solicitation (Original)
  • Original Published Date: Jun 05, 2025 02:48 pm CDT
  • Original Date Offers Due: Jul 07, 2025 05:00 pm CDT
  • Inactive Policy: 15 days after date offers due
  • Original Inactive Date: Jul 22, 2025
  • Initiative:
    • None
Classification
  • Original Set Aside: Indian Small Business Economic Enterprise (ISBEE) Set-Aside (specific to Department of Interior and Indian Health Services)
  • Product Service Code: Z2DA - REPAIR OR ALTERATION OF HOSPITALS AND INFIRMARIES
  • NAICS Code:
    • 236220 - Commercial and Institutional Building Construction
  • Place of Performance:
    Lawrence , KS 66046
    USA
Description

1. PURPOSE OF THE PROJECT

The Haskell Indian Health Center (HIHC), Indian Health Services (IHS) has a requirement for the

replacement of (4) existing exterior entryway doors, (4) interior entryway doors, and the sidelights and

transoms for all (4) vestibules.

2. DETAILED DESCRIPTION OF THE TECHNICAL REQUIREMENTS

• The interior and exterior doors shall be 42” wide to accommodate gurneys used by EMS and wide

wheelchairs.

• All exterior doors shall have a full window/daylight panel measuring approximately 34”x 69” and be

UL

752 Level 5 bullet resistant glazing or equivalent.

• All exterior glazing (door, transom, sidelights, exterior vestibule) shall be UL 752 Level 5 bullet

resistant glazing or equivalent, except where noted in the scope of work. Interior glazing (door,

transom, sidelights) shall be ¼” tempered glass.

• The northwest corner of the building has an existing metal and glass vestibule protruding from the

building measuring approximately 36” out from the building and 64” wide. The (2) panes of glass on

the exterior vestibule measure approximately 30”x 90”. These panes of glass shall be replaced with

UL Level 5 bullet resistant glazing or equivalent. Within this vestibule there shall be a left hand reverse

exterior door measuring 42”x 84”. The transom window shall be 4”x 42” and shall be 1/4” tempered

glass. The interior door, leading from the vestibule to the Pediatric/Behavior Health (north) hallway,

shall be a left hand reverse door measuring 42”x 84” with (2) sidelights measuring approximately 8”

x 100” and a transom measuring approximately 16” x 42”.

• The far west entryway leading to the Medical Staff hallway shall have a left hand reverse exterior door

measuring 42”x 84” with (2) sidelights measuring approximately 14”x 100”and a transom measuring

approximately 16”x 42”. The interior door shall be a left hand reverse door measuring 42”x 84” with

(2) sidelights measuring approximately 15”x 100” and a transom measuring approximately 16”x 42”.

• The south/southwest entryway in the breezeway between the Main Building and Wellness Center shall

have a right hand reverse exterior door measuring 42”x 84” with (1) sidelight measuring approximately

13”x 101” and a transom measuring approximately 17”x 42”. The interior door shall be a right hand

reverse door measuring 42”x 84” with (2) sidelights measuring approximately 5”x 100” and a transom

measuring approximately 16”x 42”.

• The south entryway near the kitchen shall have a left hand reverse exterior door measuring 42”x 84”

with (2) sidelights measuring approximately 15”x 100” and a transom measuring approximately 17”x

42”. The interior door shall be a left hand reverse door measuring 42”x 84” with (2) sidelights

measuring approximately 15”x 100” and a transom measuring approximately 16”x 42”.

• Contractor shall coordinate with the facility’s existing Secure Access Control provider (Cam-Dex

Security Corp.) to remove and replace the wires, card readers, and electronically operated door strikes

back to original locations or as close as possible for all replaced doors. Card readers and strikes shall

be in good working order before starting on the next exterior door for security purposes and to justify

egress.

• Door and window frames shall be black anodized aluminum and match the fit and finish of the current

frames.

• All doors, interior and exterior, shall be equipped with a commercial grade LCN door closer, panic bar,

heavy-duty continuous hinge with threshold, and lock keyed to the facility master key.

• All exterior doors, sidelights and transoms shall be tinted with a mirror tint that is reflective when

viewed from the exterior. In addition, the same tint shall be applied to the front (east), exterior,

automatic sliding door entrance. Tinting shall be minimum of 35% shade.

• All (4) exterior doors shall be equipped with awnings that span the width of the exterior frame to cover

persons entering and exiting the building. The awnings shall be black anodized aluminum (or

equivalent metal) to match the fit and finish of the exterior frames. The awnings shall not extend more

than 36” away from the building. All awnings shall be equipped with gutters and downspouts to divert

water away from the building.


Attachments/Links
Contact Information
Contracting Office Address
  • 701 MARKET DRIVE
  • OKLAHOMA CITY , OK 73114
  • USA
Primary Point of Contact
Secondary Point of Contact


History

Related Document

May 19, 2025[Presolicitation (Original)] HASKELL IHS - VESTIBULE DOORS, SIDELIGHTS, AND TRANSOMS REPLACEMENT
Daily notification on new contract opportunities

With GovernmentContracts, you can:

  • Find more opportunities and win more business
  • Receive daily alerts for all new bid opportunities
  • Get contract opportunities matched to your business
ONE WEEK FREE TRIAL
* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.