INVITATION TO BID - Influent Flume Repairs at South Water Treatment Plant

Location: Illinois
Posted: Oct 16, 2026
Due: Nov 6, 2026
Agency: City of Decatur
Type of Government: State & Local
Category:
  • 68 - Chemicals and Chemical Products
  • J - Maintenance, Repair, and Rebuilding of Equipment
  • Z - Maintenance, Repair or Alteration of Real Property
Solicitation No: #PUR2026-09
Publication URL: To access bid details, please log in.
Bid Number: #PUR2026-09
Bid Title: INVITATION TO BID - Influent Flume Repairs at South Water Treatment Plant
Category: General City Bids
Status: Open
Publication Date/Time:
10/16/2026 9:00 AM
Publication Information:
Herald & Review
Closing Date/Time:
11/6/2026 10:00 AM
Contact Person:
Kelly Harrison
Procurement Officer
217-424-2763
Miscellaneous:
Site visits must be completed by Tuesday, October 27, 2026.
To schedule a site visit contact John Dodwell, edodwell@decaturil.gov


Any questions about the project must be submitted by Friday, October 30, 2026, to kharrison@decaturil.gov

Related Documents:

Attachment Preview

no. date by ckd description 0 10/1/26 AMG AMH ISSUED FOR BID

CITY OF DECATUR
SOUTH WATER TREATMENT PLANT
INFLUENT FLUME REPAIRS
DECATUR, ILLINOIS
Contract Drawings
GENERAL / STRUCTURAL DRAWINGS
DWG NO. DWG TITLE
G001 COVER AND INDEX
S001 STRUCTURAL LEGEND AND ABBREVIATIONS
S101 BASIN COMPLEX ENLARGED PLAN
S102 BASIN COMPLEX SECTION PLAN VIEWS
S301 BASIN COMPLEX EXPANSION JOINT SECTIONS AND PHOTOS
S302 BASIN COMPLEX FLUME INTERSECTION PHOTO
SOUTH WTP
NORTH
SCALE = NTS
OCTOBER 2026
BMcD Project No. 200565
no. date by ckd description
0 10/1/26 AMG AMH ISSUED FOR BID
Cover
425 S. WOODS MILL ROAD, SUITE 300
CHESTERFIELD, MO 63017
314-682-1500

ABBREVIATIONS CONCRETE REINFORCING BAR NOMENCLATURE GENERAL REQUIREMENTS: A. GENERAL AA ALUMINUM ASSOCIATION EW EACH WAY OZ OUNCE BAR SPACING IN INCHES AASHTO AMERICAN ASSOCIATION OF EXP EXPANSION Pa PASCAL REINFORCING BAR DESIGNATION 1. WHERE EXISTING FACILITIES ARE IN OPERATION, CONSULT WITH THE STATE HIGHWAY AND EXIST EXISTING PCA PORTLAND CEMENT (U.S. CUSTOMARY) BAR POSITION ABBREVIATION OWNER'S REPRESENTATIVE AND COORDINATE ALL WORK IN SUCH A TRANSPORTATION OFFICIALS EXT EXTERIOR ASSOCIATION "NEAR FACE" MANNER AS TO MINIMIZE EFFECTS ON OWNER'S OPERATIONS. AB ANCHOR BOLT FAB FABRICATE PCF POUNDS PER CUBIC FOOT 2. CONTRACT DRAWINGS AND SPECIFICATIONS REPRESENT THE BAR ABT ABOUT f'c SPECIFIED 28 DAY PCI PRESTRESSED CONCRETE #6@18 NF FINISHED STRUCTURE, DESIGNED TO BE SELF-SUPPORTING AFTER IDENTIFICATION ACI AMERICAN CONCRETE COMPRESSIVE STRENGTH INSTITUTE, POUNDS PER ALL PERMANENT STRUCTURAL COMPONENTS AND CONNECTIONS INSTITUTE OF CONCRETE CUBIC INCH 36LS ARE COMPLETE. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ACO AT CONTRACTOR'S OPTION FD FLOOR DRAIN PED PEDESTAL CONCRETE REINFORCING BAR MEANS AND METHODS OF CONSTRUCTION INCLUDING, BUT NOT ADH ADHESIVE FDN FOUNDATION PEN PENETRATE LAP SPLICE LENGTH IN INCHES LIMITED TO: SHORING AND TEMPORARY BRACING; SITE SAFETY FOR AGGR AGGREGATE FF FAR FACE PERP PERPENDICULAR ALL PERSONNEL AT THE SITE; PROTECTION OF EXISTING AHR ANCHOR FL FLOOR PJF PREFORMED JOINT FILLER STRUCTURES AND FACILITIES. IF CONSTRUCTION LOADS EXCEED AHU AIR HANDLING UNIT FLG FLANGE PJTN PROJECTION STANDARD OR THE DESIGN LOADS INDICATED IN THE CONTRACT DOCUMENTS, THE AISC AMERICAN INSTITUTE OF f'm SPECIFIED COMPRESSIVE PL PLATE, PROPERTY LINE 90 degrees HOOK CONTRACTOR SHALL BE RESPONSIBLE FOR TEMPORARY SHORING CONCRETE STEEL CONSTRUCTION STRENGTH OF MASONRY PLCS PLACES OR OTHER MEANS TO AVOID OVERLOADING THE STRUCTURE AND/OR REINFORCING BAR CONCRETE REINFORCING BAR AISI AMERICAN IRON AND STEEL FNSH FINISH PLF POUNDS PER LINEAR FOOT IT'S COMPONENTS. SITE VISITS BY THE OWNER'S REPRESENTATIVE INSTITUTE FRP FIBERGLASS REINFORCED PREFAB PREFABRICATED SHALL NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITIES AL, ALUM ALUMINUM PLASTIC PSF POUNDS PER SQUARE FOOT CONTAINED HEREIN. ALTN ALTERNATE fs PERMISSIBLE STEEL STRESS PSI POUNDS PER SQUARE INCH STANDARD 3. NOTIFY THE OWNER OF ANY DISCREPANCIES DISCOVERED IN THESE ANSI AMERICAN NATIONAL FS FAR SIDE PRV PRESSURE RELIEF VALVE 180 degrees HOOK DRAWINGS OR WITH OTHER TRADES. STANDARDS INSTITUTE FT FEET, FOOT PT POINT CONCRETE REINFORCING BAR 4. INSTALL MANUFACTURED ITEMS (PRODUCTS) IN ACCORDANCE WITH APPROX APPROXIMATE FTG FOOTING PVC POLYVINYL CHLORIDE THE MANUFACTURER'S WRITTEN INSTRUCTIONS AND ARCH ARCHITECTURAL FUT FUTURE PWS PLASTIC WATERSTOP SPECIFICATIONS. ASTM AMERICAN SOCIETY FOR Fy, fy YIELD STRESS R RISERS 5. CONTRACTOR MAY SUBSTITUTE ALTERNATE PRODUCTS, WHERE MECHANICAL TESTING AND MATERIALS GA GAGE, GAUGE RAD RADIUS PROPRIETARY PRODUCTS ARE SPECIFIED, SUBJECT TO OWNER SPLICE INTERNATIONAL GAL GALLON RD ROOF DRAIN CONCRETE MECHANICAL SPLICE APPROVAL. AWS AMERICAN WELDING GALV GALVANIZED REF REFERENCE REINFORCING BAR 6. BID ALTERNATE NO. 1 INCLUDES REPAIR OF EXISTING FLUME SOCIETY GF GRANULAR FILL REINF REINFORCEMENT EXPANSION JOINT AS INDICATED ON DRAWINGS. B, BOT BOTTOM GND GROUND REQD REQUIRED 7. BID ALTERNATE NO. 2 INCLUDES INSTALLATION OF PVC PIPE BELOW BBP BOTTOM OF BASE PLATE GR GRADE REV REVISION LAP SPLICE LENGTH IN INCHES ABBREVIATION FOR "LAP SPLICE" EXISTING LEAK LOCATIONS AT THE AREAS INDICATED ON THE BC BOLT CIRCLE GRTG GRATING RJ ROUGHENED JOINT DRAWINGS. BETW BETWEEN GS GRATING SUPPORT RM ROOM 60LS CONCRETE REINFORCING BAR BLDG BUILDING H HIGH S SOUTH LAP SPLICE B. PROJECT CONDITIONS BM BEAM HC HOLLOW CORE SCHED SCHEDULE 1. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS. IF BO BOTTOM OF HEX HEXAGON SD SUBDRAIN EXISTING CONDITIONS DIFFER FROM THOSE SHOWN, THE OWNER BOC BOTTOM OF CONCRETE HK HOOK SE SOUTHEAST, STEEL EDGE SHALL BE NOTIFIED PRIOR TO CONTINUANCE OF THE WORK. BOS BOTTOM OF STEEL HR HANDRAIL SECT SECTION LAP SPLICE LENGTH IN INCHES ABBREVIATION FOR "LAP SPLICE" 2. CONTRACTOR SHALL BE RESPONSIBLE TO PROTECT, WORK AROUND, BRG BEARING HORIZ HORIZONTAL SHT SHEET LAP SPLICE AT RELOCATE, OR TEMPORARILY REMOVE AND REPLACE ALL BRKT BRACKET HPT HIGH POINT SIM SIMILAR CONTRACTOR'S 48LS CONCRETE REINFORCING BAR OBSTRUCTIONS DURING DEMOLITION FOR, AND CONSTRUCTION, OF CAP CAPACITY HS HIGH STRENGTH SJ SAWED JOINT OPTION THE NEW STRUCTURE. CB CORNER BAR HVAC HEATING, VENTILATION, AND SLO SHORT LEG OUTSTANDING ACO CC CLEAR COVER AIR CONDITIONING SLP SLOPE C. SUBMITTALS ABBREVIATION FOR C/C CENTER TO CENTER IBC INTERNATIONAL BUILDING SLV SLEEVE 1. THE CONTRACTOR SHALL SUBMIT TO, AND RECEIVE APPROVAL FROM "AT CONTRACTOR'S OPTION" CE CONCRETE EDGE CODE SP SPACE THE OWNER PRIOR TO FABRICATION/INSTALLATION ALL SHOP CF CUBIC FEET ID INSIDE DIAMETER SPEC SPECIFICATION BAR SPACING IN INCHES DRAWINGS, PRODUCT DATA, ETC. NECESSARY FOR PERFORMANCE CHKR CHECKERED IF INSIDE FACE SQ SQUARE OF THE WORK, INCLUDING BUT NOT LIMITED TO: CIR CIRCLE IJ ISOLATION JOINT SS, SST STAINLESS STEEL ABBREVIATION BAR POSITION ABBREVIATION "FAR FACE" A. CONCRETE ANCHORS CIRC CIRCULAR INTR INTERIOR ST SINGLE TEE FOR "CORNER BAR" B. EPOXY ADHESIVES CIRCUM CIRCUMFERENTIAL INVT INVERT STD STANDARD LEG SHOWN, DIMENSION IN INCHES C. PIPE SUPPORT HARDWARE CIS CENTERED IN SLAB JT JOINT STIF STIFFENER REINFORCING CIW CENTERED IN WALL K KIP (1000 POUNDS) STIR STIRRUP BAR DESIGNATION LEG PERPENDICULAR TO VIEW, DIMENSION IN INCHES CJ CONSTRUCTION JOINT KB KNEE BRACE STL STEEL CJP COMPLETE JOINT KPL KICK PLATE STR STRAIGHT, STAIR #5CB@12 FF 72X96 CORNER BAR PENETRATION kg KILOGRAM STRL STRUCTURAL CL CENTER LINE kN KILONEWTON STRUC STRUCTURE CLJ CONTROL JOINT KSF KIPS PER SQUARE FOOT SW SOUTHWEST CONCRETE REINFORCING BAR CLR CLEAR KSI KIPS PER SQUARE INCH SYMM SYMMETRICAL CM CENTIMETER L ANGLE, LONG T TON, TREAD, THICKNESS, TOP MATERIALS LEGEND CMU CONCRETE MASONRY UNIT LAD LADDER TEMP TEMPERATURE, TEMPORARY CO CONCRETE OPENING LB POUND THK THICK COL COLUMN LG LENGTH, LONG THD THREAD CONC CONCRETE LL LIVE LOAD THRU THROUGH STEEL ALUMINUM CONN CONNECTION LLH LONG LEG HORIZONTAL T&B TOP AND BOTTOM (LARGE SCALE) CONSTR CONSTRUCTION LLV LONG LEG VERTICAL TOB TOP OF BOLT CONT CONTINUOUS LLO LONG LEG OUTSTANDING TOC TOP OF CONCRETE CONTR CONTRACT LNTL LINTEL TOF TOP OF FLOOR CHECKERED PLATE WATER COORD COORDINATE LONG LONGITUDINAL TOG TOP OF GRATING COR CORNER LPT LOW POINT TOS TOP OF STEEL CRSI CONCRETE REINFORCING LS LAP SPLICE TOW TOP OF WALL STEEL INSTITUTE M METER TSF TONS PER SQUARE FOOT CONCRETE EXPANSION MATERIAL CTR CENTER MATL MATERIAL TRD TREAD CWB CAPILLARY WATER BARRIER MAX MAXIMUM TYP TYPICAL CY CUBIC YARD MECH MECHANICAL UON UNLESS OTHERWISE NOTED CONCRETE db BAR DIAMETER MEZZ MEZZANINE UNO UNLESS NOTED OTHERWISE MASONRY UNITS FASTENERS DBL DOUBLE MFR MANUFACTURE(R) VAR VARIES DET DETAIL MH MANHOLE VERT VERTICAL DGA DENSE GRADED AGGREGATE MIN MINIMUM W WEST, WIDE EARTH DIA DIAMETER MISC MISCELLANEOUS WD WIDTH DIAG DIAGONAL MJ MECHANICAL JOINT WF WIDE FLANGE REINFORCING BARS DIM DIMENSION MK MARK WP WORK POINT DK DECKING MM MILLIMETER WS WATERSTOP COMPACTED DL DEAD LOAD MPa MEGAPASCAL WT WEIGHT, WATERTIGHT STRUCTURAL FILL DN DOWN MS MECHANICAL SPLICE WW WASTEWATER STRUCTURAL STEEL DT DOUBLE TEE N NORTH WWF WELDED WIRE FABRIC (SMALL SCALE) DWG DRAWING NA NOT APPLICABLE W/ WITH GRANULAR FILL DWL DOWEL NE NORTHEAST W/O WITHOUT E EAST NF NEAR FACE YD YARD EA EACH NIC NOT IN CONTRACT & AND ED EQUIPMENT DRAIN NO NUMBER APPROXIMATELY GRATING EF EACH FACE NOM NOMINAL @ AT EJ EXPANSION JOINT NS NEAR SIDE x BY EL ELEVATION NTS NOT TO SCALE degrees DEGREE (PLANE ANGLE) ELEC ELECTRICAL NW NORTHWEST DIAMETER GROUT EMBED EMBEDMENT OC ON CENTER = EQUAL EP EQUIPMENT PAD OD OUTSIDE DIAMETER > GREATER THAN ERCP ELLIPTICAL REINF CONC PIPE OF OUTER FACE < LESS THAN EQ EQUAL OPNG OPENING # NUMBER, POUND ROCK EQ SP EQUALLY SPACED OPP OPPOSITE % PERCENT EQUIP EQUIPMENT OSHA OCCUPATIONAL SAFETY AND EQUIV EQUIVALENT HEALTH ADMINISTRATION no. date by ckd description 0 10/1/26 AMG AMH ISSUED FOR BID
425 S. WOODS MILL ROAD, SUITE 300 CHESTERFIELD, MO 63017 314-682-1500
date detailed JULY 15, 2026 B. BAIR designed checked A. GRIFFIN A. HOLMES
Macon County, Illinois SOUTH WTP INFLUENT FLUME REPAIRS STRUCTURAL LEGEND AND ABBREVIATIONS project contract 200565 drawing rev. S001 0 sheet of sheets file 200565_S_FLUME REPAIR_R24.rvt
10/1/26 AMG AMH
ABBREVIATIONS CONCRETE REINFORCING BAR NOMENCLATURE
AA ALUMINUM ASSOCIATION AASHTO AMERICAN ASSOCIATION OF STATE HIGHWAY AND TRANSPORTATION OFFICIALS AB ANCHOR BOLT ABT ABOUT ACI AMERICAN CONCRETE INSTITUTE ACO AT CONTRACTOR'S OPTION ADH ADHESIVE AGGR AGGREGATE AHR ANCHOR AHU AIR HANDLING UNIT AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION AISI AMERICAN IRON AND STEEL INSTITUTE AL, ALUM ALUMINUM ALTN ALTERNATE ANSI AMERICAN NATIONAL STANDARDS INSTITUTE APPROX APPROXIMATE ARCH ARCHITECTURAL ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS INTERNATIONAL AWS AMERICAN WELDING SOCIETY B, BOT BOTTOM BBP BOTTOM OF BASE PLATE BC BOLT CIRCLE BETW BETWEEN BLDG BUILDING BM BEAM BO BOTTOM OF BOC BOTTOM OF CONCRETE BOS BOTTOM OF STEEL BRG BEARING BRKT BRACKET CAP CAPACITY CB CORNER BAR CC CLEAR COVER C/C CENTER TO CENTER CE CONCRETE EDGE CF CUBIC FEET CHKR CHECKERED CIR CIRCLE CIRC CIRCULAR CIRCUM CIRCUMFERENTIAL CIS CENTERED IN SLAB CIW CENTERED IN WALL CJ CONSTRUCTION JOINT CJP COMPLETE JOINT PENETRATION CL CENTER LINE CLJ CONTROL JOINT CLR CLEAR CM CENTIMETER CMU CONCRETE MASONRY UNIT CO CONCRETE OPENING COL COLUMN CONC CONCRETE CONN CONNECTION CONSTR CONSTRUCTION CONT CONTINUOUS CONTR CONTRACT COORD COORDINATE COR CORNER CRSI CONCRETE REINFORCING STEEL INSTITUTE CTR CENTER CWB CAPILLARY WATER BARRIER CY CUBIC YARD db BAR DIAMETER DBL DOUBLE DET DETAIL DGA DENSE GRADED AGGREGATE DIA DIAMETER DIAG DIAGONAL DIM DIMENSION DK DECKING DL DEAD LOAD DN DOWN DT DOUBLE TEE DWG DRAWING DWL DOWEL E EAST EA EACH ED EQUIPMENT DRAIN EF EACH FACE EJ EXPANSION JOINT EL ELEVATION ELEC ELECTRICAL EMBED EMBEDMENT EP EQUIPMENT PAD ERCP ELLIPTICAL REINF CONC PIPE EQ EQUAL EQ SP EQUALLY SPACED EQUIP EQUIPMENT EQUIV EQUIVALENT EW EACH WAY EXP EXPANSION EXIST EXISTING EXT EXTERIOR FAB FABRICATE f'c SPECIFIED 28 DAY COMPRESSIVE STRENGTH OF CONCRETE FD FLOOR DRAIN FDN FOUNDATION FF FAR FACE FL FLOOR FLG FLANGE f'm SPECIFIED COMPRESSIVE STRENGTH OF MASONRY FNSH FINISH FRP FIBERGLASS REINFORCED PLASTIC fs PERMISSIBLE STEEL STRESS FS FAR SIDE FT FEET, FOOT FTG FOOTING FUT FUTURE Fy, fy YIELD STRESS GA GAGE, GAUGE GAL GALLON GALV GALVANIZED GF GRANULAR FILL GND GROUND GR GRADE GRTG GRATING GS GRATING SUPPORT H HIGH HC HOLLOW CORE HEX HEXAGON HK HOOK HR HANDRAIL HORIZ HORIZONTAL HPT HIGH POINT HS HIGH STRENGTH HVAC HEATING, VENTILATION, AND AIR CONDITIONING IBC INTERNATIONAL BUILDING CODE ID INSIDE DIAMETER IF INSIDE FACE IJ ISOLATION JOINT INTR INTERIOR INVT INVERT JT JOINT K KIP (1000 POUNDS) KB KNEE BRACE KPL KICK PLATE kg KILOGRAM kN KILONEWTON KSF KIPS PER SQUARE FOOT KSI KIPS PER SQUARE INCH L ANGLE, LONG LAD LADDER LB POUND LG LENGTH, LONG LL LIVE LOAD LLH LONG LEG HORIZONTAL LLV LONG LEG VERTICAL LLO LONG LEG OUTSTANDING LNTL LINTEL LONG LONGITUDINAL LPT LOW POINT LS LAP SPLICE M METER MATL MATERIAL MAX MAXIMUM MECH MECHANICAL MEZZ MEZZANINE MFR MANUFACTURE(R) MH MANHOLE MIN MINIMUM MISC MISCELLANEOUS MJ MECHANICAL JOINT MK MARK MM MILLIMETER MPa MEGAPASCAL MS MECHANICAL SPLICE N NORTH NA NOT APPLICABLE NE NORTHEAST NF NEAR FACE NIC NOT IN CONTRACT NO NUMBER NOM NOMINAL NS NEAR SIDE NTS NOT TO SCALE NW NORTHWEST OC ON CENTER OD OUTSIDE DIAMETER OF OUTER FACE OPNG OPENING OPP OPPOSITE OSHA OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION OZ OUNCE Pa PASCAL PCA PORTLAND CEMENT ASSOCIATION PCF POUNDS PER CUBIC FOOT PCI PRESTRESSED CONCRETE INSTITUTE, POUNDS PER CUBIC INCH PED PEDESTAL PEN PENETRATE PERP PERPENDICULAR PJF PREFORMED JOINT FILLER PJTN PROJECTION PL PLATE, PROPERTY LINE PLCS PLACES PLF POUNDS PER LINEAR FOOT PREFAB PREFABRICATED PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH PRV PRESSURE RELIEF VALVE PT POINT PVC POLYVINYL CHLORIDE PWS PLASTIC WATERSTOP R RISERS RAD RADIUS RD ROOF DRAIN REF REFERENCE REINF REINFORCEMENT REQD REQUIRED REV REVISION RJ ROUGHENED JOINT RM ROOM S SOUTH SCHED SCHEDULE SD SUBDRAIN SE SOUTHEAST, STEEL EDGE SECT SECTION SHT SHEET SIM SIMILAR SJ SAWED JOINT SLO SHORT LEG OUTSTANDING SLP SLOPE SLV SLEEVE SP SPACE SPEC SPECIFICATION SQ SQUARE SS, SST STAINLESS STEEL ST SINGLE TEE STD STANDARD STIF STIFFENER STIR STIRRUP STL STEEL STR STRAIGHT, STAIR STRL STRUCTURAL STRUC STRUCTURE SW SOUTHWEST SYMM SYMMETRICAL T TON, TREAD, THICKNESS, TOP TEMP TEMPERATURE, TEMPORARY THK THICK THD THREAD THRU THROUGH T&B TOP AND BOTTOM TOB TOP OF BOLT TOC TOP OF CONCRETE TOF TOP OF FLOOR TOG TOP OF GRATING TOS TOP OF STEEL TOW TOP OF WALL TSF TONS PER SQUARE FOOT TRD TREAD TYP TYPICAL UON UNLESS OTHERWISE NOTED UNO UNLESS NOTED OTHERWISE VAR VARIES VERT VERTICAL W WEST, WIDE WD WIDTH WF WIDE FLANGE WP WORK POINT WS WATERSTOP WT WEIGHT, WATERTIGHT WW WASTEWATER WWF WELDED WIRE FABRIC W/ WITH W/O WITHOUT YD YARD & AND APPROXIMATELY @ AT x BY degrees DEGREE (PLANE ANGLE) DIAMETER = EQUAL > GREATER THAN < LESS THAN # NUMBER, POUND % PERCENT BAR SPACING IN INCHES REINFORCING BAR DESIGNATION BAR POSITION ABBREVIATION (U.S. CUSTOMARY) "NEAR FACE" BAR #6@18 NF IDENTIFICATION 36LS CONCRETE REINFORCING BAR LAP SPLICE LENGTH IN INCHES STANDARD OR 90 degrees HOOK CONCRETE REINFORCING BAR CONCRETE REINFORCING BAR STANDARD 180 degrees HOOK CONCRETE REINFORCING BAR MECHANICAL SPLICE CONCRETE MECHANICAL SPLICE REINFORCING BAR LAP SPLICE LENGTH IN INCHES ABBREVIATION FOR "LAP SPLICE" CONCRETE REINFORCING BAR 60LS LAP SPLICE LAP SPLICE LENGTH IN INCHES ABBREVIATION FOR "LAP SPLICE" LAP SPLICE AT CONTRACTOR'S CONCRETE REINFORCING BAR 48LS OPTION ACO ABBREVIATION FOR "AT CONTRACTOR'S OPTION" BAR SPACING IN INCHES ABBREVIATION BAR POSITION ABBREVIATION "FAR FACE" FOR "CORNER BAR" LEG SHOWN, DIMENSION IN INCHES REINFORCING BAR DESIGNATION LEG PERPENDICULAR TO VIEW, DIMENSION IN INCHES #5CB@12 FF 72X96 CORNER BAR CONCRETE REINFORCING BAR
MATERIALS LEGEND
STEEL ALUMINUM (LARGE SCALE) CHECKERED PLATE WATER CONCRETE EXPANSION MATERIAL CONCRETE MASONRY UNITS FASTENERS EARTH REINFORCING BARS COMPACTED STRUCTURAL FILL STRUCTURAL STEEL (SMALL SCALE) GRANULAR FILL GRATING GROUT ROCK

ABBREVIATIONS CONCRETE REINFORCING BAR NOMENCLATURE
GENERAL REQUIREMENTS:
A. GENERAL
AA ALUMINUM ASSOCIATION EW EACH WAY OZ OUNCE
BAR SPACING IN INCHES
AASHTO AMERICAN ASSOCIATION OF EXP EXPANSION Pa PASCAL REINFORCING BAR DESIGNATION 1. WHERE EXISTING FACILITIES ARE IN OPERATION, CONSULT WITH THE
STATE HIGHWAY AND EXIST EXISTING PCA PORTLAND CEMENT (U.S. CUSTOMARY) BAR POSITION ABBREVIATION OWNER'S REPRESENTATIVE AND COORDINATE ALL WORK IN SUCH A
TRANSPORTATION OFFICIALS EXT EXTERIOR ASSOCIATION "NEAR FACE" MANNER AS TO MINIMIZE EFFECTS ON OWNER'S OPERATIONS.
AB ANCHOR BOLT FAB FABRICATE PCF POUNDS PER CUBIC FOOT 2. CONTRACT DRAWINGS AND SPECIFICATIONS REPRESENT THE
BAR
ABT ABOUT f'c SPECIFIED 28 DAY PCI PRESTRESSED CONCRETE #6@18 NF FINISHED STRUCTURE, DESIGNED TO BE SELF-SUPPORTING AFTER
IDENTIFICATION
ACI AMERICAN CONCRETE COMPRESSIVE STRENGTH INSTITUTE, POUNDS PER ALL PERMANENT STRUCTURAL COMPONENTS AND CONNECTIONS
INSTITUTE OF CONCRETE CUBIC INCH 36LS ARE COMPLETE. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL
ACO AT CONTRACTOR'S OPTION FD FLOOR DRAIN PED PEDESTAL CONCRETE REINFORCING BAR MEANS AND METHODS OF CONSTRUCTION INCLUDING, BUT NOT
ADH ADHESIVE FDN FOUNDATION PEN PENETRATE LAP SPLICE LENGTH IN INCHES LIMITED TO: SHORING AND TEMPORARY BRACING; SITE SAFETY FOR
AGGR AGGREGATE FF FAR FACE PERP PERPENDICULAR ALL PERSONNEL AT THE SITE; PROTECTION OF EXISTING
AHR ANCHOR FL FLOOR PJF PREFORMED JOINT FILLER STRUCTURES AND FACILITIES. IF CONSTRUCTION LOADS EXCEED
AHU AIR HANDLING UNIT FLG FLANGE PJTN PROJECTION STANDARD OR THE DESIGN LOADS INDICATED IN THE CONTRACT DOCUMENTS, THE
AISC AMERICAN INSTITUTE OF f'm SPECIFIED COMPRESSIVE PL PLATE, PROPERTY LINE 90 degrees HOOK CONTRACTOR SHALL BE RESPONSIBLE FOR TEMPORARY SHORING
CONCRETE
STEEL CONSTRUCTION STRENGTH OF MASONRY PLCS PLACES OR OTHER MEANS TO AVOID OVERLOADING THE STRUCTURE AND/OR
REINFORCING BAR CONCRETE REINFORCING BAR
AISI AMERICAN IRON AND STEEL FNSH FINISH PLF POUNDS PER LINEAR FOOT IT'S COMPONENTS. SITE VISITS BY THE OWNER'S REPRESENTATIVE
INSTITUTE FRP FIBERGLASS REINFORCED PREFAB PREFABRICATED SHALL NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITIES
AL, ALUM ALUMINUM PLASTIC PSF POUNDS PER SQUARE FOOT CONTAINED HEREIN.
ALTN ALTERNATE fs PERMISSIBLE STEEL STRESS PSI POUNDS PER SQUARE INCH STANDARD 3. NOTIFY THE OWNER OF ANY DISCREPANCIES DISCOVERED IN THESE
ANSI AMERICAN NATIONAL FS FAR SIDE PRV PRESSURE RELIEF VALVE 180 degrees HOOK DRAWINGS OR WITH OTHER TRADES.
STANDARDS INSTITUTE FT FEET, FOOT PT POINT CONCRETE REINFORCING BAR 4. INSTALL MANUFACTURED ITEMS (PRODUCTS) IN ACCORDANCE WITH
APPROX APPROXIMATE FTG FOOTING PVC POLYVINYL CHLORIDE THE MANUFACTURER'S WRITTEN INSTRUCTIONS AND
ARCH ARCHITECTURAL FUT FUTURE PWS PLASTIC WATERSTOP SPECIFICATIONS.
ASTM AMERICAN SOCIETY FOR Fy, fy YIELD STRESS R RISERS 5. CONTRACTOR MAY SUBSTITUTE ALTERNATE PRODUCTS, WHERE
MECHANICAL
TESTING AND MATERIALS GA GAGE, GAUGE RAD RADIUS PROPRIETARY PRODUCTS ARE SPECIFIED, SUBJECT TO OWNER
SPLICE
INTERNATIONAL GAL GALLON RD ROOF DRAIN CONCRETE MECHANICAL SPLICE APPROVAL.
AWS AMERICAN WELDING GALV GALVANIZED REF REFERENCE REINFORCING BAR 6. BID ALTERNATE NO. 1 INCLUDES REPAIR OF EXISTING FLUME
SOCIETY GF GRANULAR FILL REINF REINFORCEMENT EXPANSION JOINT AS INDICATED ON DRAWINGS.
B, BOT BOTTOM GND GROUND REQD REQUIRED 7. BID ALTERNATE NO. 2 INCLUDES INSTALLATION OF PVC PIPE BELOW
BBP BOTTOM OF BASE PLATE GR GRADE REV REVISION LAP SPLICE LENGTH IN INCHES ABBREVIATION FOR "LAP SPLICE" EXISTING LEAK LOCATIONS AT THE AREAS INDICATED ON THE
BC BOLT CIRCLE GRTG GRATING RJ ROUGHENED JOINT DRAWINGS.
BETW BETWEEN GS GRATING SUPPORT RM ROOM 60LS CONCRETE REINFORCING BAR
BLDG BUILDING H HIGH S SOUTH LAP SPLICE B. PROJECT CONDITIONS
BM BEAM HC HOLLOW CORE SCHED SCHEDULE 1. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS. IF
BO BOTTOM OF HEX HEXAGON SD SUBDRAIN EXISTING CONDITIONS DIFFER FROM THOSE SHOWN, THE OWNER
BOC BOTTOM OF CONCRETE HK HOOK SE SOUTHEAST, STEEL EDGE SHALL BE NOTIFIED PRIOR TO CONTINUANCE OF THE WORK.
BOS BOTTOM OF STEEL HR HANDRAIL SECT SECTION LAP SPLICE LENGTH IN INCHES ABBREVIATION FOR "LAP SPLICE" 2. CONTRACTOR SHALL BE RESPONSIBLE TO PROTECT, WORK AROUND,
BRG BEARING HORIZ HORIZONTAL SHT SHEET LAP SPLICE AT RELOCATE, OR TEMPORARILY REMOVE AND REPLACE ALL
BRKT BRACKET HPT HIGH POINT SIM SIMILAR CONTRACTOR'S 48LS CONCRETE REINFORCING BAR OBSTRUCTIONS DURING DEMOLITION FOR, AND CONSTRUCTION, OF
CAP CAPACITY HS HIGH STRENGTH SJ SAWED JOINT OPTION THE NEW STRUCTURE.
CB CORNER BAR HVAC HEATING, VENTILATION, AND SLO SHORT LEG OUTSTANDING
ACO
CC CLEAR COVER AIR CONDITIONING SLP SLOPE C. SUBMITTALS
ABBREVIATION FOR
C/C CENTER TO CENTER IBC INTERNATIONAL BUILDING SLV SLEEVE 1. THE CONTRACTOR SHALL SUBMIT TO, AND RECEIVE APPROVAL FROM
"AT CONTRACTOR'S OPTION"
CE CONCRETE EDGE CODE SP SPACE THE OWNER PRIOR TO FABRICATION/INSTALLATION ALL SHOP
CF CUBIC FEET ID INSIDE DIAMETER SPEC SPECIFICATION BAR SPACING IN INCHES DRAWINGS, PRODUCT DATA, ETC. NECESSARY FOR PERFORMANCE
CHKR CHECKERED IF INSIDE FACE SQ SQUARE OF THE WORK, INCLUDING BUT NOT LIMITED TO:
CIR CIRCLE IJ ISOLATION JOINT SS, SST STAINLESS STEEL ABBREVIATION BAR POSITION ABBREVIATION "FAR FACE" A. CONCRETE ANCHORS
CIRC CIRCULAR INTR INTERIOR ST SINGLE TEE FOR "CORNER BAR" B. EPOXY ADHESIVES
CIRCUM CIRCUMFERENTIAL INVT INVERT STD STANDARD LEG SHOWN, DIMENSION IN INCHES C. PIPE SUPPORT HARDWARE
CIS CENTERED IN SLAB JT JOINT STIF STIFFENER REINFORCING
CIW CENTERED IN WALL K KIP (1000 POUNDS) STIR STIRRUP BAR DESIGNATION LEG PERPENDICULAR TO VIEW,
DIMENSION IN INCHES
CJ CONSTRUCTION JOINT KB KNEE BRACE STL STEEL
CJP COMPLETE JOINT KPL KICK PLATE STR STRAIGHT, STAIR #5CB@12 FF 72X96
CORNER BAR
PENETRATION kg KILOGRAM STRL STRUCTURAL
CL CENTER LINE kN KILONEWTON STRUC STRUCTURE
CLJ CONTROL JOINT KSF KIPS PER SQUARE FOOT SW SOUTHWEST CONCRETE REINFORCING BAR
CLR CLEAR KSI KIPS PER SQUARE INCH SYMM SYMMETRICAL
CM CENTIMETER L ANGLE, LONG T TON, TREAD, THICKNESS, TOP
MATERIALS LEGEND
CMU CONCRETE MASONRY UNIT LAD LADDER TEMP TEMPERATURE, TEMPORARY
CO CONCRETE OPENING LB POUND THK THICK
COL COLUMN LG LENGTH, LONG THD THREAD
CONC CONCRETE LL LIVE LOAD THRU THROUGH STEEL
ALUMINUM
CONN CONNECTION LLH LONG LEG HORIZONTAL T&B TOP AND BOTTOM (LARGE SCALE)
CONSTR CONSTRUCTION LLV LONG LEG VERTICAL TOB TOP OF BOLT
CONT CONTINUOUS LLO LONG LEG OUTSTANDING TOC TOP OF CONCRETE
CONTR CONTRACT LNTL LINTEL TOF TOP OF FLOOR
CHECKERED PLATE WATER
COORD COORDINATE LONG LONGITUDINAL TOG TOP OF GRATING
COR CORNER LPT LOW POINT TOS TOP OF STEEL
CRSI CONCRETE REINFORCING LS LAP SPLICE TOW TOP OF WALL
STEEL INSTITUTE M METER TSF TONS PER SQUARE FOOT CONCRETE EXPANSION MATERIAL
CTR CENTER MATL MATERIAL TRD TREAD
CWB CAPILLARY WATER BARRIER MAX MAXIMUM TYP TYPICAL
CY CUBIC YARD MECH MECHANICAL UON UNLESS OTHERWISE NOTED
CONCRETE
db BAR DIAMETER MEZZ MEZZANINE UNO UNLESS NOTED OTHERWISE
MASONRY UNITS FASTENERS
DBL DOUBLE MFR MANUFACTURE(R) VAR VARIES
DET DETAIL MH MANHOLE VERT VERTICAL
DGA DENSE GRADED AGGREGATE MIN MINIMUM W WEST, WIDE
EARTH
DIA DIAMETER MISC MISCELLANEOUS WD WIDTH
DIAG DIAGONAL MJ MECHANICAL JOINT WF WIDE FLANGE REINFORCING BARS
DIM DIMENSION MK MARK WP WORK POINT
DK DECKING MM MILLIMETER WS WATERSTOP COMPACTED
DL DEAD LOAD MPa MEGAPASCAL WT WEIGHT, WATERTIGHT STRUCTURAL FILL
DN DOWN MS MECHANICAL SPLICE WW WASTEWATER STRUCTURAL STEEL
DT DOUBLE TEE N NORTH WWF WELDED WIRE FABRIC (SMALL SCALE)
DWG DRAWING NA NOT APPLICABLE W/ WITH
GRANULAR FILL
DWL DOWEL NE NORTHEAST W/O WITHOUT
E EAST NF NEAR FACE YD YARD
EA EACH NIC NOT IN CONTRACT & AND
ED EQUIPMENT DRAIN NO NUMBER APPROXIMATELY
GRATING
EF EACH FACE NOM NOMINAL @ AT
EJ EXPANSION JOINT NS NEAR SIDE x BY
EL ELEVATION NTS NOT TO SCALE degrees DEGREE (PLANE ANGLE)
ELEC ELECTRICAL NW NORTHWEST DIAMETER GROUT
EMBED EMBEDMENT OC ON CENTER = EQUAL
EP EQUIPMENT PAD OD OUTSIDE DIAMETER > GREATER THAN
ERCP ELLIPTICAL REINF CONC PIPE OF OUTER FACE < LESS THAN
EQ EQUAL OPNG OPENING # NUMBER, POUND ROCK
EQ SP EQUALLY SPACED OPP OPPOSITE % PERCENT
EQUIP EQUIPMENT OSHA OCCUPATIONAL SAFETY AND
EQUIV EQUIVALENT HEALTH ADMINISTRATION
gnimliforciM
roF
elacS
sretemilliM
sehcnI
1 2 3 4 5 6 7 8 9 10 11 12 13 14
no. date by ckd description
0 10/1/26 AMG AMH ISSUED FOR BID
A
B
C
D
E
F
G
425 S. WOODS MILL ROAD, SUITE 300
CHESTERFIELD, MO 63017
314-682-1500
H
date detailed
JULY 15, 2026 B. BAIR
designed checked
A. GRIFFIN A. HOLMES
I
Macon County, Illinois
SOUTH WTP INFLUENT FLUME REPAIRS
STRUCTURAL LEGEND AND
J
ABBREVIATIONS
project contract
200565
drawing rev.
S001 0
sheet of sheets
file 200565_S_FLUME REPAIR_R24.rvt
10/1/2026 3:58:15 PM C:\Revit_Projects\200565_S_FLUME REPAIR_R24_bmbair@burnsmcd.com.rvt

SEE SECTIONAL PLAN AT ELEV 643 ON DWG S102 EXISTING ACCESS HATCH BID ALTERNATE NO. 1 EXISTING EXPANSION JOINT TO BE REPAIRED SEE SECTIONAL PLAN ON DWG S102 BASIN COMPLEX ENLARGED TOP PLAN NOT TO SCALE NORTH THE REGISTRANT OF THE NEWLY APPLIED SEAL, DATED 8/XX/26 , ONLY ASSUMES RESPONSIBILITY FOR THE CHANGES AS INDICATED ON BURNS & McDONNELL DRAWING S101 REVISION 0 . no. date by ckd description 0 10/1/26 AMG AMH ISSUED FOR BID
425 S. WOODS MILL ROAD, SUITE 300 CHESTERFIELD, MO 63017 314-682-1500
date detailed JULY 15, 2026 B. BAIR designed checked A. GRIFFIN A. HOLMES
Macon County, Illinois SOUTH WTP INFLUENT FLUME REPAIRS BASIN COMPLEX ENLARGED PLAN project contract 200565 drawing rev. S101 0 sheet of sheets file 200565_S_FLUME REPAIR_R24.rvt
10/1/26 AMG AMH
SEE SECTIONAL PLAN
AT ELEV 643 ON DWG S102
BID ALTERNATE NO. 1
EXISTING EXPANSION JOINT
TO BE REPAIRED
SEE SECTIONAL PLAN ON DWG S102
NO RTH
BASIN COMPLEX
ENLARGED PLAN

SEE SECTIONAL PLAN
AT ELEV 643 ON DWG S102
EXISTING ACCESS HATCH
BID ALTERNATE NO. 1
EXISTING EXPANSION JOINT
TO BE REPAIRED
SEE SECTIONAL PLAN ON DWG S102
BASIN COMPLEX ENLARGED TOP PLAN
NOT TO SCALE NORTH
gnimliforciM
roF
elacS
sretemilliM
sehcnI
1 2 3 4 5 6 7 8 9 10 11 12 13 14
no. date by ckd description
0 10/1/26 AMG AMH ISSUED FOR BID
A
B
C
D
E
F
G
425 S. WOODS MILL ROAD, SUITE 300
CHESTERFIELD, MO 63017
314-682-1500
H
date detailed
JULY 15, 2026 B. BAIR
designed checked
A. GRIFFIN A. HOLMES
I
Macon County, Illinois
SOUTH WTP INFLUENT FLUME REPAIRS
BASIN COMPLEX
J
ENLARGED PLAN
THE REGISTRANT OF
project contract
THE NEWLY APPLIED
200565
SEAL, DATED 8/XX/26 ,
ONLY ASSUMES RESPONSIBILITY FOR THE CHANGES drawing rev.
AS INDICATED ON BURNS & McDONNELL DRAWING S101 0
S101 REVISION 0 .
sheet of sheets
file 200565_S_FLUME REPAIR_R24.rvt
10/1/2026 3:58:16 PM C:\Revit_Projects\200565_S_FLUME REPAIR_R24_bmbair@burnsmcd.com.rvt

3 S302 APPROX LOCATION OF BOTTOM SLAB AND WALL CRACKING, TO BE CRACK INJECTED (SEE FLUME INTERSECTION EPOXY CRACK INJECTION NOTES ON THIS SHEET FOR ADDITIONAL DETAILS) SECTIONAL PLAN @ EL 643.00' NORTH NOT TO SCALE BID ALTERNATE NO. 1 FLUME EXPANSION JOINT REPAIR NOTES: FLUME INTERSECTION EPOXY CRACK INJECTION NOTES: 1. CONSTRUCTION SEQUENCING: 1. CONTRACTOR AND/OR INSTALLER SHALL HAVE COMPLETED WORK SIMILAR IN MATERIAL, A. INFLUENT FLUME SHUTDOWN FOR INSTALLATION OF EXPANSION JOINT REPAIRS SHALL DESIGN AND EXTENT TO THAT INDICATED FOR THIS PROJECT WITH A MINIMUM OF FIVE BE LIMITED TO APPROXIMATELY A FOUR-HOUR WORKING WINDOW. CONTRACTOR SHALL PREVIOUS SUCCESSFUL INSTALLATIONS. COORDINATE SCHEDULED SHUTDOWN WITH OWNER. 2. CRACKING SHOWN IS CONCEPTUAL IN NATURE. FOR BIDDING PURPOSES, CONTRACTOR 2. INSTALLATION NOTES: SHALL ASSUME 60 LINEAR FEET OF CRACK INJECTION. A. DETAIL SHALL BE INSTALLED FROM THE INTERIOR OF THE FLUME B. ALL PRODUCTS SHALL BE NSF 61 PRODUCT CERTIFIED 3. CRACK INJECTION SHALL CONFORM TO ASTM C881 TYPE IV. C. CONTRACTOR SHALL CLEAN CONCRETE SURFACE AT AREAS IN CONTACT WITH THE PROPOSED DETAIL TO REMOVE LOOSE CONCRETE, SCALING, DEBRIS AND LAITENANCE. 4. ALL PRODUCTS SHALL BE NSF 61 PRODUCT CERTIFIED. D. GASKET SHALL BE 14" THICK AND CONFORM TO ASTM D2240 SHORE 50A. E. GASKET SHALL BE INSTALLED AS ONE CONTINUOUS STRIP FROM SLAB TO WALL 5. ACCEPTABLE PRODUCTS: SURFACES. A. SIKAFIX HH LV F. BATTEN BAR SHALL BE SPLICED AS REQUIRED FOR INSTALLATION IN ACCORDANCE WITH B. SEALBOSS FLEXGEL TYPICAL DETAIL. C. ENGINEER APPROVED EQUAL G. INSTALL COMPONENTS PER MANUFACTURERS WRITTEN INSTRUCTIONS. 6. CRACK INJECTION SHALL BE PERFORMED FROM THE NEGATIVE (DRY) SIDE OF THE WALL. BID ALTERNATE NO. 2 NOTES: 1. BID ALTERNATE IS TYPICAL AT BOTH THE NORTH (FLUME INTERSECTION) AND SOUTH 7. INSTALL PER MANUFACTURERS WRITTEN INSTRUCTIONS AND IN ACCORDANCE WITH THE (EXPANSION JOINT) FLUME REPAIR LOCATIONS. FOLLOWING: A. CLEAN CRACKS WITH OIL FREE COMPRESSED AIR OR LOW-PRESSURE WATER TO 2. LOCATE PVC PIPE BELOW EXISTING LEAK LOCATIONS. FIELD ROUTE TO NEAREST FLOOR REMOVE LOOSE PARTICLES DRAIN AT MINIMUM 1/4" PER FOOT. B. CLEAN AREAS TO RECEIVE CAPPING ADHESIVE OF OIL, DIRT, AND OTHER SUBSTANCES A. AT THE NORTH (FLUME INTERSECTION) LOCATION, A FLOOR DRAIN IS LOCATED BELOW THAT WOULD INTERFERE WITH BOND. 2 THE WORK AREA IN THE SECONDARY SLUDGE CONTROL AREA (FIELD VERIFY). C. PLACE INJECTION PORTS AS RECOMMENDED BY EPOXY MANUFACTURER, BUT NOT TO B. THE SOUTH (EXPANSION JOINT) LOCATION SHALL BE ROUTED TO LOCATION INDICATED EXCEED 12 INCHES. SEAL INJECTION PORTS IN PLACE WITH CAPPING ADHESIVE. S301 ON DRAWING S301. D. INJECT EPOXY ADHESIVE, BEGINNING AT WIDEST PART OF CRACK AND WORKING TOWARD NARROWER PARTS. INJECT ADHESIVE INTO PORTS TO REFUSAL, CAPPING 3. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL PIPE SUPPORTS. SUPPORTS SHALL 304 ADJACENT PORTS WHEN THEY EXTRUDE EPOXY. CAP INJECTED PORTS AND INJECT STAINLESS STEEL CONFORMING TO MSS-SP 58 WITH 304 STAINLESS STEEL CONCRETE THROUGH ADJACENT PORTS UNTIL CRACK IS FILLED. ANCHORS. E. AFTER EPOXY ADHESIVE HAS SET, REMOVE INJECTION PORTS AND GRIND SURFACES SMOOTH. A F. SEAL CRACKS AT EXPOSED SURFACES WITH A RIBBON OF CAPPING ADHESIVE AT LEAST S301 1/4 INCH THICK BY 1 INCH WIDER THAN CRACK. APPROX LOCATION OF EXIST FLUME EJ (SEE BID ALTERNATE NO. 1 FLUME EXPANSION JOINT REPAIR NOTES ON THIS SHEET FOR ADDITIONAL DETAILS) 1 THE REGISTRANT OF S301 THE NEWLY APPLIED SEAL, DATED 8/XX/26 , ONLY ASSUMES RESPONSIBILITY FOR THE CHANGES NORTH TUNNEL SECTIONAL PLAN AS INDICATED ON BURNS & McDONNELL DRAWING NOT TO SCALE S101 REVISION 0 . no. date by ckd description 0 10/1/26 AMG AMH ISSUED FOR BID
425 S. WOODS MILL ROAD, SUITE 300 CHESTERFIELD, MO 63017 314-682-1500
date detailed JULY 15, 2026 B. BAIR designed checked A. GRIFFIN A. HOLMES
Macon County, Illinois SOUTH WTP INFLUENT FLUME REPAIRS BASIN COMPLEX SECTION PLAN VIEWS project contract 200565 drawing rev. S102 0 sheet of sheets file 200565_S_FLUME REPAIR_R24.rvt
10/1/26 AMG AMH
3
S302
APPROX LOCATION OF BOTTOM SLAB
AND WALL CRACKING, TO BE CRACK
INJECTED (SEE FLUME INTERSECTION
EPOXY CRACK INJECTION NOTES ON
FLUME INTERSECTION EPOXY CRACK INJECTION NOTES:
1.
CONTRACTOR AND/OR INSTALLER SHALL HAVE COMPLETED WORK SIMILAR IN MATERIAL,
DESIGN AND EXTENT TO THAT INDICATED FOR THIS PROJECT WITH A MINIMUM OF FIVE
PREVIOUS SUCCESSFUL INSTALLATIONS.
NFLUENT FLUME SHUTDOWN FOR INSTALLATION OF EXPANSION JOINT REPAIRS SHALL
E LIMITED TO APPROXIMATELY A FOUR - HOUR WORKING WINDOW. CONTRACTOR SHALL
OORDINATE SCHEDULED SHUTDOWN WITH OWNER.
CRACKING SHOWN IS CONCEPTUAL IN NATURE. FOR BIDDING PURPOSES, CONTRACTOR
SHALL ASSUME 60 LINEAR FEET OF CRACK INJECTION.
ETAIL SHALL BE INSTALLED FROM THE INTERIOR OF THE FLUME
LL PRODUCTS SHALL BE NSF 61 PRODUCT CERTIFIED
ONTRACTOR SHALL CLEAN CONCRETE SURFACE AT AREAS IN CONTACT WITH THE
ROPOSED DETAIL TO REMOVE LOOSE CONCRETE, SCALING, DEBRIS AND LAITENANCE
ASKET SHALL BE 14 " THICK AND CONFORM TO ASTM D2240 SHORE 50A.
ASKET SHALL BE INSTALLED AS ONE CONTINUOUS STRIP FROM SLAB TO WALL
URFACES.
ATTEN BAR SHALL BE SPLICED AS REQUIRED FOR INSTALLATION IN ACCORDANCE WITH
YPICAL DETAIL.
NSTALL COMPONENTS PER MANUFACTURERS WRITTEN INSTRUCTIONS.
ACCEPTABLE PRODUCTS:
A.
B.
C.
SIKAFIX HH LV
SEALBOSS FLEXGEL
ENGINEER APPROVED EQUAL
INSTALL PER MANUFACTURERS WRITTEN INSTRUCTIONS AND IN ACCORDANCE WITH THE
FOLLOWING:
A.
CLEAN CRACKS WITH OIL FREE COMPRESSED AIR OR LOW - PRESSURE WATER TO
REMOVE LOOSE PARTICLES
CLEAN AREAS TO RECEIVE CAPPING ADHESIVE OF OIL, DIRT, AND OTHER SUBSTANCES
THAT WOULD INTERFERE WITH BOND.
PLACE INJECTION PORTS AS RECOMMENDED BY EPOXY MANUFACTURER, BUT NOT TO
EXCEED 12 INCHES. SEAL INJECTION PORTS IN PLACE WITH CAPPING ADHESIVE.
INJECT EPOXY ADHESIVE, BEGINNING AT WIDEST PART OF CRACK AND WORKING
TOWARD NARROWER PARTS. INJECT ADHESIVE INTO PORTS TO REFUSAL, CAPPING
ADJACENT PORTS WHEN THEY EXTRUDE EPOXY. CAP INJECTED PORTS AND INJECT
THROUGH ADJACENT PORTS UNTIL CRACK IS FILLED.
AFTER EPOXY ADHESIVE HAS SET, REMOVE INJECTION PORTS AND GRIND SURFACES
SMOOTH.
SEAL CRACKS AT EXPOSED SURFACES WITH A RIBBON OF CAPPING ADHESIVE AT LEAST
1/4 INCH THICK BY 1 INCH WIDER THAN CRACK.
" PER FOOT.
T THE NORTH (FLUME INTERSECTION) LOCATION, A FLOOR DRAIN IS LOCATED BELOW
HE WORK AREA IN THE SECONDARY SLUDGE CONTROL AREA (FIELD VERIFY).
HE SOUTH (EXPANSION JOINT) LOCATION SHALL BE ROUTED TO LOCATION INDICATED
N DRAWING S301.
2
S301
01
- SP 58 WITH 304 STAINLESS STEEL CONCRETE
APPROX LOCATION OF
EXIST FLUME EJ (SEE BID
ALTERNATE NO. 1 FLUME
EXPANSION JOINT REPAIR
NOTES ON THIS SHEET FOR
ADDITIONAL DETAILS)
1 1
S301
NO RTH

3
S302
APPROX LOCATION OF BOTTOM SLAB
AND WALL CRACKING, TO BE CRACK
INJECTED (SEE FLUME INTERSECTION
EPOXY CRACK INJECTION NOTES ON
THIS SHEET FOR ADDITIONAL DETAILS)
SECTIONAL PLAN @ EL 643.00'
NORTH
NOT TO SCALE
2
S301
A
S301
APPROX LOCATION OF
EXIST FLUME EJ (SEE BID
ALTERNATE NO. 1 FLUME
EXPANSION JOINT REPAIR
NOTES ON THIS SHEET FOR
ADDITIONAL DETAILS)
1
S301
NORTH
TUNNEL SECTIONAL PLAN
NOT TO SCALE
gnimliforciM
roF
elacS
sretemilliM
sehcnI
1 2 3 4 5 6 7 8 9 10 11 12 13 14
no. date by ckd description
0 10/1/26 AMG AMH ISSUED FOR BID
A
B
C
D
E
BID ALTERNATE NO. 1 FLUME EXPANSION JOINT REPAIR NOTES: FLUME INTERSECTION EPOXY CRACK INJECTION NOTES:
1. CONSTRUCTION SEQUENCING: 1. CONTRACTOR AND/OR INSTALLER SHALL HAVE COMPLETED WORK SIMILAR IN MATERIAL,
A. INFLUENT FLUME SHUTDOWN FOR INSTALLATION OF EXPANSION JOINT REPAIRS SHALL DESIGN AND EXTENT TO THAT INDICATED FOR THIS PROJECT WITH A MINIMUM OF FIVE
BE LIMITED TO APPROXIMATELY A FOUR-HOUR WORKING WINDOW. CONTRACTOR SHALL PREVIOUS SUCCESSFUL INSTALLATIONS. F
COORDINATE SCHEDULED SHUTDOWN WITH OWNER.
2. CRACKING SHOWN IS CONCEPTUAL IN NATURE. FOR BIDDING PURPOSES, CONTRACTOR
2. INSTALLATION NOTES: SHALL ASSUME 60 LINEAR FEET OF CRACK INJECTION.
A. DETAIL SHALL BE INSTALLED FROM THE INTERIOR OF THE FLUME
B. ALL PRODUCTS SHALL BE NSF 61 PRODUCT CERTIFIED 3. CRACK INJECTION SHALL CONFORM TO ASTM C881 TYPE IV.
C. CONTRACTOR SHALL CLEAN CONCRETE SURFACE AT AREAS IN CONTACT WITH THE
PROPOSED DETAIL TO REMOVE LOOSE CONCRETE, SCALING, DEBRIS AND LAITENANCE. 4. ALL PRODUCTS SHALL BE NSF 61 PRODUCT CERTIFIED.
D. GASKET SHALL BE 14" THICK AND CONFORM TO ASTM D2240 SHORE 50A.
E. GASKET SHALL BE INSTALLED AS ONE CONTINUOUS STRIP FROM SLAB TO WALL 5. ACCEPTABLE PRODUCTS:
SURFACES. A. SIKAFIX HH LV
F. BATTEN BAR SHALL BE SPLICED AS REQUIRED FOR INSTALLATION IN ACCORDANCE WITH B. SEALBOSS FLEXGEL G
TYPICAL DETAIL. C. ENGINEER APPROVED EQUAL
G. INSTALL COMPONENTS PER MANUFACTURERS WRITTEN INSTRUCTIONS.
6. CRACK INJECTION SHALL BE PERFORMED FROM THE NEGATIVE (DRY) SIDE OF THE WALL.
BID ALTERNATE NO. 2 NOTES:
1. BID ALTERNATE IS TYPICAL AT BOTH THE NORTH (FLUME INTERSECTION) AND SOUTH 7. INSTALL PER MANUFACTURERS WRITTEN INSTRUCTIONS AND IN ACCORDANCE WITH THE
(EXPANSION JOINT) FLUME REPAIR LOCATIONS. FOLLOWING:
A. CLEAN CRACKS WITH OIL FREE COMPRESSED AIR OR LOW-PRESSURE WATER TO
2. LOCATE PVC PIPE BELOW EXISTING LEAK LOCATIONS. FIELD ROUTE TO NEAREST FLOOR REMOVE LOOSE PARTICLES
425 S. WOODS MILL ROAD, SUITE 300
DRAIN AT MINIMUM 1/4" PER FOOT. B. CLEAN AREAS TO RECEIVE CAPPING ADHESIVE OF OIL, DIRT, AND OTHER SUBSTANCES
CHESTERFIELD, MO 63017
A. AT THE NORTH (FLUME INTERSECTION) LOCATION, A FLOOR DRAIN IS LOCATED BELOW THAT WOULD INTERFERE WITH BOND.
314-682-1500
H
THE WORK AREA IN THE SECONDARY SLUDGE CONTROL AREA (FIELD VERIFY). C. PLACE INJECTION PORTS AS RECOMMENDED BY EPOXY MANUFACTURER, BUT NOT TO
B. THE SOUTH (EXPANSION JOINT) LOCATION SHALL BE ROUTED TO LOCATION INDICATED EXCEED 12 INCHES. SEAL INJECTION PORTS IN PLACE WITH CAPPING ADHESIVE.
date detailed
ON DRAWING S301. D. INJECT EPOXY ADHESIVE, BEGINNING AT WIDEST PART OF CRACK AND WORKING
JULY 15, 2026 B. BAIR
TOWARD NARROWER PARTS. INJECT ADHESIVE INTO PORTS TO REFUSAL, CAPPING
3. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL PIPE SUPPORTS. SUPPORTS SHALL 304 ADJACENT PORTS WHEN THEY EXTRUDE EPOXY. CAP INJECTED PORTS AND INJECT
designed checked
STAINLESS STEEL CONFORMING TO MSS-SP 58 WITH 304 STAINLESS STEEL CONCRETE THROUGH ADJACENT PORTS UNTIL CRACK IS FILLED.
A. GRIFFIN A. HOLMES
ANCHORS. E. AFTER EPOXY ADHESIVE HAS SET, REMOVE INJECTION PORTS AND GRIND SURFACES
SMOOTH.
F. SEAL CRACKS AT EXPOSED SURFACES WITH A RIBBON OF CAPPING ADHESIVE AT LEAST
1/4 INCH THICK BY 1 INCH WIDER THAN CRACK.
I
Macon County, Illinois
SOUTH WTP INFLUENT FLUME REPAIRS
BASIN COMPLEX
J
SECTION PLAN VIEWS
THE REGISTRANT OF
project contract
THE NEWLY APPLIED
200565
SEAL, DATED 8/XX/26 ,
ONLY ASSUMES RESPONSIBILITY FOR THE CHANGES drawing rev.
AS INDICATED ON BURNS & McDONNELL DRAWING S102 0
S101 REVISION 0 .
sheet of sheets
file 200565_S_FLUME REPAIR_R24.rvt
10/1/2026 3:58:16 PM C:\Revit_Projects\200565_S_FLUME REPAIR_R24_bmbair@burnsmcd.com.rvt

NOTES: 1. SEE BID ALTERNATE NO. 1 FLUME EXPANSION JOINT REPAIR NOTES AND BID ALTERNATE NO. 2 NOTES ON DRAWING S102 FOR ADDITIONAL DETAILS. 8'-0" FV C C "6-'5 2 0 '-0 " + /- CORE DRILL THROUGH EXIST MASONRY WALL CORE SHALL BE C MINIMUM 8" CLEAR FROM EDGE OF ROUGH OPENING OF MASONRY GROUT EXP JT GASKET PACK ANNULUS AROUND PIPE SEE DETAIL THIS DWG BID ALTERNATE 3" DIA PVC PIPE FIELD ROUTE TO EXISTING FLOOR DRAIN SECTION A ELEVATION 1 S102 S102 NOT TO SCALE NOT TO SCALE 1/2" DIA 316 SST WEDGE EPDM GASKET ANCHOR W/ 2 1/2" (MIN) 1/4" X 2" SST BATTEN BAR EMBED AT 18" OC (TYP) (SEE SPLICE DETAIL THIS DWG) 4" REMOVE AND REPLACE LIGHT; EXIST EJ FLOOR DRAIN BEYOND COORDINATE WITH OWNER INTERIOR OF FLUME 1" BACKERROD EXTERIOR OF FLUME STAINLESS STEEL BID ALTERNATE NO. 2: 3" DIA PIPE HANGER PVC PIPE FIELD ROUTE TO 3" PVC PIPE FLOOR DRAIN AS INDICATED BID ALTERNATE CAP UPSTREAM END NO. 2 SEE NOTES SECTION C NOT TO SCALE 1'-6" MAX 2" 3" 3" 2" SST BATTEN BAR EPDM GASKET THE REGISTRANT OF TYPICAL BATTEN BAR SPLICE DETAIL THE NEWLY APPLIED NOT TO SCALE SEAL, DATED 8/XX/26 , ELEVATION 2 ONLY ASSUMES RESPONSIBILITY FOR THE CHANGES AS INDICATED ON BURNS & McDONNELL DRAWING S102 NOT TO SCALE S101 REVISION 0 . no. date by ckd description 0 10/1/26 AMG AMH ISSUED FOR BID
425 S. WOODS MILL ROAD, SUITE 300 CHESTERFIELD, MO 63017 314-682-1500
date detailed JULY 15, 2026 B. BAIR designed checked A. GRIFFIN A. HOLMES
Macon County, Illinois SOUTH WTP INFLUENT FLUME REPAIRS BASIN COMPLEX EXPANSION JOINT SECTIONS AND PHOTOS project contract 200565 drawing rev. S301 0 sheet of sheets file 200565_S_FLUME REPAIR_R24.rvt
SEE BID ALTERNATE NO. 1 FLUME EXPANSION JOINT REPAIR
NOTES AND BID ALTERNATE NO. 2 NOTES ON DRAWING S102
FOR ADDITIONAL DETAILS.
10/1/26 AMG AMH
C
CORE DRILL THROUGH
EXIST MASONRY
WALL CORE SHALL BE
MINIMUM 8" CLEAR FROM
EDGE OF ROUGH OPENING
OF MASONRY GROUT
PACK ANNULUS AROUND PIPE
EXP JT GASKET
SEE DETAIL THIS DWG
1/2" DIA 316 SST WEDG
ANCHOR W/ 2 1/2" (MIN)
EMBED AT 18" OC (T YP)
1/4" X 2" SST BATTEN BAR
(SEE SPLICE DETAIL THIS DWG)
REMOVE AND REPLACE LIGHT;
COORDINATE WITH OWNER
STAINLESS STEEL
PIPE HANGER
BID ALTERNATE NO. 2: 3" DIA
PVC PIPE FIELD ROUTE TO
FLOOR DRAIN AS INDICATED
CAP UPSTREAM END
3" PVC PIPE
BID ALTERNATE
NO. 2 SEE NOTES

8'-0" FV
C
C
C
EXP JT GASKET
SEE DETAIL THIS DWG
"6-'5
2
0
'-0
"
+
/-
CORE DRILL THROUGH
EXIST MASONRY
WALL CORE SHALL BE
MINIMUM 8" CLEAR FROM
EDGE OF ROUGH OPENING
OF MASONRY GROUT
PACK ANNULUS AROUND PIPE
BID ALTERNATE
3" DIA PVC PIPE FIELD ROUTE
TO EXISTING FLOOR DRAIN
NOT TO SCALE NOT TO SCALE
1/2" DIA 316 SST WEDGE
EPDM GASKET ANCHOR W/ 2 1/2" (MIN) 1/4" X 2" SST BATTEN BAR
EMBED AT 18" OC (TYP) (SEE SPLICE DETAIL THIS DWG)
4"
REMOVE AND REPLACE LIGHT; EXIST EJ FLOOR DRAIN BEYOND
COORDINATE WITH OWNER
INTERIOR OF FLUME
1" BACKERROD
EXTERIOR OF FLUME
STAINLESS STEEL BID ALTERNATE NO. 2: 3" DIA
PIPE HANGER PVC PIPE FIELD ROUTE TO
3" PVC PIPE
FLOOR DRAIN AS INDICATED
BID ALTERNATE
CAP UPSTREAM END
NO. 2 SEE NOTES
NOT TO SCALE
1'-6" MAX
2" 3" 3" 2"
SST BATTEN BAR
EPDM GASKET
TYPICAL BATTEN BAR SPLICE DETAIL
NOT TO SCALE
NOT TO SCALE
gnimliforciM
roF
elacS
sretemilliM
sehcnI
1 2 3 4 5 6 7 8 9 10 11 12 13 14
no. date by ckd description
NOTES:
1. SEE BID ALTERNATE NO. 1 FLUME EXPANSION JOINT REPAIR
0 10/1/26 AMG AMH ISSUED FOR BID
NOTES AND BID ALTERNATE NO. 2 NOTES ON DRAWING S102
FOR ADDITIONAL DETAILS.
A
B
C
D
SECTION A ELEVATION 1 E
S102 S102
F
G
425 S. WOODS MILL ROAD, SUITE 300
CHESTERFIELD, MO 63017
314-682-1500
H
date detailed
JULY 15, 2026 B. BAIR
designed checked
A. GRIFFIN A. HOLMES
SECTION C
I
Macon County, Illinois
SOUTH WTP INFLUENT FLUME REPAIRS
BASIN COMPLEX
J
EXPANSION JOINT SECTIONS AND PHOTOS
THE REGISTRANT OF
project contract
THE NEWLY APPLIED
200565
SEAL, DATED 8/XX/26 ,
ELEVATION 2 ONLY ASSUMES RESPONSIBILITY FOR THE CHANGES drawing rev.
AS INDICATED ON BURNS & McDONNELL DRAWING S301 0
S102
S101 REVISION 0 .
sheet of sheets
file 200565_S_FLUME REPAIR_R24.rvt
10/1/2026 3:58:17 PM C:\Revit_Projects\200565_S_FLUME REPAIR_R24_bmbair@burnsmcd.com.rvt

EPOXY CRACK INJECTION (SLAB AND WALLS - SEE DRAWING S102) BID ALTERNATE NO. 2 ROUTE PVC PIPE ALONG WALL TO FLOOR DRAIN BELOW CONTRACTOR SHALL FIELD VERIFY EXISTING FLOOR DRAIN LOCATION FOR BID ALTERNATE NO. 2 ELEVATION 3 S102 NOT TO SCALE no. date by ckd description 0 10/1/26 AMG AMH ISSUED FOR BID
425 S. WOODS MILL ROAD, SUITE 300 CHESTERFIELD, MO 63017 314-682-1500
date detailed JULY 15, 2026 B. BAIR designed checked A. GRIFFIN A. HOLMES
Macon County, Illinois SOUTH WTP INFLUENT FLUME REPAIRS BASIN COMPLEX FLUME INTERSECTION PHOTO project contract 200565 drawing rev. S302 0 sheet of sheets file 200565_S_FLUME REPAIR_R24.rvt
10/1/26 AMG AMH
EPOXY CRACK INJECTION
(SLAB AND WALLS -
DRAWING S102)

EPOXY CRACK INJECTION
(SLAB AND WALLS - SEE
DRAWING S102)
BID ALTERNATE NO. 2
ROUTE PVC PIPE ALONG
WALL TO FLOOR DRAIN BELOW
CONTRACTOR SHALL FIELD
VERIFY EXISTING FLOOR
DRAIN LOCATION FOR BID
ALTERNATE NO. 2
NOT TO SCALE
gnimliforciM
roF
elacS
sretemilliM
sehcnI
1 2 3 4 5 6 7 8 9 10 11 12 13 14
no. date by ckd description
0 10/1/26 AMG AMH ISSUED FOR BID
A
B
C
D
E
F
ELEVATION 3
S102
G
425 S. WOODS MILL ROAD, SUITE 300
CHESTERFIELD, MO 63017
314-682-1500
H
date detailed
JULY 15, 2026 B. BAIR
designed checked
A. GRIFFIN A. HOLMES
I
Macon County, Illinois
SOUTH WTP INFLUENT FLUME REPAIRS
BASIN COMPLEX
J
FLUME INTERSECTION PHOTO
project contract
200565
drawing rev.
S302 0
sheet of sheets
file 200565_S_FLUME REPAIR_R24.rvt
10/1/2026 3:58:18 PM C:\Revit_Projects\200565_S_FLUME REPAIR_R24_bmbair@burnsmcd.com.rvt

This is the opportunity summary page. It provides an overview of this opportunity and a preview of the attached documentation.
Daily notification on new contract opportunities

With GovernmentContracts, you can:

  • Find more opportunities and win more business
  • Receive daily alerts for all new bid opportunities
  • Get contract opportunities matched to your business
ONE WEEK FREE TRIAL

See also

DEPARTMENT OF WATER MANAGEMENT Commodities 70287,2 1271795B 1271795B: Lignite Coal Based Powdered Activated

City of Chicago

Bid Due: 11/20/2026

Bid Title: 2027 WATER SOFTENER SALT Category: RFQ/RFP Status: Open Description: The Village

Woodstock city

Bid Due: 11/20/2026

DEPARTMENT OF WATER MANAGEMENT Small Order 78344 1334052 1334052: Jardine Water Purification Plant

City of Chicago

Bid Due: 12/18/2026

DEPARTMENT OF WATER MANAGEMENT Small Order 78344,1 1334052 1334052: Jardine Water Purification Plant

City of Chicago

Bid Due: 1/22/2027

* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.