| no. date by ckd description
0 10/1/26 AMG AMH ISSUED FOR BID |
|
|
|
CITY OF DECATUR
SOUTH WATER TREATMENT PLANT
INFLUENT FLUME REPAIRS
DECATUR, ILLINOIS
Contract Drawings
GENERAL / STRUCTURAL DRAWINGS
DWG NO. DWG TITLE
G001 COVER AND INDEX
S001 STRUCTURAL LEGEND AND ABBREVIATIONS
S101 BASIN COMPLEX ENLARGED PLAN
S102 BASIN COMPLEX SECTION PLAN VIEWS
S301 BASIN COMPLEX EXPANSION JOINT SECTIONS AND PHOTOS
S302 BASIN COMPLEX FLUME INTERSECTION PHOTO
SOUTH WTP
NORTH
SCALE = NTS
OCTOBER 2026
BMcD Project No. 200565
no. date by ckd description
0 10/1/26 AMG AMH ISSUED FOR BID
Cover
425 S. WOODS MILL ROAD, SUITE 300
CHESTERFIELD, MO 63017
314-682-1500
| ABBREVIATIONS CONCRETE REINFORCING BAR NOMENCLATURE
GENERAL REQUIREMENTS:
A. GENERAL
AA ALUMINUM ASSOCIATION EW EACH WAY OZ OUNCE
BAR SPACING IN INCHES
AASHTO AMERICAN ASSOCIATION OF EXP EXPANSION Pa PASCAL REINFORCING BAR DESIGNATION 1. WHERE EXISTING FACILITIES ARE IN OPERATION, CONSULT WITH THE
STATE HIGHWAY AND EXIST EXISTING PCA PORTLAND CEMENT (U.S. CUSTOMARY) BAR POSITION ABBREVIATION OWNER'S REPRESENTATIVE AND COORDINATE ALL WORK IN SUCH A
TRANSPORTATION OFFICIALS EXT EXTERIOR ASSOCIATION "NEAR FACE" MANNER AS TO MINIMIZE EFFECTS ON OWNER'S OPERATIONS.
AB ANCHOR BOLT FAB FABRICATE PCF POUNDS PER CUBIC FOOT 2. CONTRACT DRAWINGS AND SPECIFICATIONS REPRESENT THE
BAR
ABT ABOUT f'c SPECIFIED 28 DAY PCI PRESTRESSED CONCRETE #6@18 NF FINISHED STRUCTURE, DESIGNED TO BE SELF-SUPPORTING AFTER
IDENTIFICATION
ACI AMERICAN CONCRETE COMPRESSIVE STRENGTH INSTITUTE, POUNDS PER ALL PERMANENT STRUCTURAL COMPONENTS AND CONNECTIONS
INSTITUTE OF CONCRETE CUBIC INCH 36LS ARE COMPLETE. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL
ACO AT CONTRACTOR'S OPTION FD FLOOR DRAIN PED PEDESTAL CONCRETE REINFORCING BAR MEANS AND METHODS OF CONSTRUCTION INCLUDING, BUT NOT
ADH ADHESIVE FDN FOUNDATION PEN PENETRATE LAP SPLICE LENGTH IN INCHES LIMITED TO: SHORING AND TEMPORARY BRACING; SITE SAFETY FOR
AGGR AGGREGATE FF FAR FACE PERP PERPENDICULAR ALL PERSONNEL AT THE SITE; PROTECTION OF EXISTING
AHR ANCHOR FL FLOOR PJF PREFORMED JOINT FILLER STRUCTURES AND FACILITIES. IF CONSTRUCTION LOADS EXCEED
AHU AIR HANDLING UNIT FLG FLANGE PJTN PROJECTION STANDARD OR THE DESIGN LOADS INDICATED IN THE CONTRACT DOCUMENTS, THE
AISC AMERICAN INSTITUTE OF f'm SPECIFIED COMPRESSIVE PL PLATE, PROPERTY LINE 90 degrees HOOK CONTRACTOR SHALL BE RESPONSIBLE FOR TEMPORARY SHORING
CONCRETE
STEEL CONSTRUCTION STRENGTH OF MASONRY PLCS PLACES OR OTHER MEANS TO AVOID OVERLOADING THE STRUCTURE AND/OR
REINFORCING BAR CONCRETE REINFORCING BAR
AISI AMERICAN IRON AND STEEL FNSH FINISH PLF POUNDS PER LINEAR FOOT IT'S COMPONENTS. SITE VISITS BY THE OWNER'S REPRESENTATIVE
INSTITUTE FRP FIBERGLASS REINFORCED PREFAB PREFABRICATED SHALL NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITIES
AL, ALUM ALUMINUM PLASTIC PSF POUNDS PER SQUARE FOOT CONTAINED HEREIN.
ALTN ALTERNATE fs PERMISSIBLE STEEL STRESS PSI POUNDS PER SQUARE INCH STANDARD 3. NOTIFY THE OWNER OF ANY DISCREPANCIES DISCOVERED IN THESE
ANSI AMERICAN NATIONAL FS FAR SIDE PRV PRESSURE RELIEF VALVE 180 degrees HOOK DRAWINGS OR WITH OTHER TRADES.
STANDARDS INSTITUTE FT FEET, FOOT PT POINT CONCRETE REINFORCING BAR 4. INSTALL MANUFACTURED ITEMS (PRODUCTS) IN ACCORDANCE WITH
APPROX APPROXIMATE FTG FOOTING PVC POLYVINYL CHLORIDE THE MANUFACTURER'S WRITTEN INSTRUCTIONS AND
ARCH ARCHITECTURAL FUT FUTURE PWS PLASTIC WATERSTOP SPECIFICATIONS.
ASTM AMERICAN SOCIETY FOR Fy, fy YIELD STRESS R RISERS 5. CONTRACTOR MAY SUBSTITUTE ALTERNATE PRODUCTS, WHERE
MECHANICAL
TESTING AND MATERIALS GA GAGE, GAUGE RAD RADIUS PROPRIETARY PRODUCTS ARE SPECIFIED, SUBJECT TO OWNER
SPLICE
INTERNATIONAL GAL GALLON RD ROOF DRAIN CONCRETE MECHANICAL SPLICE APPROVAL.
AWS AMERICAN WELDING GALV GALVANIZED REF REFERENCE REINFORCING BAR 6. BID ALTERNATE NO. 1 INCLUDES REPAIR OF EXISTING FLUME
SOCIETY GF GRANULAR FILL REINF REINFORCEMENT EXPANSION JOINT AS INDICATED ON DRAWINGS.
B, BOT BOTTOM GND GROUND REQD REQUIRED 7. BID ALTERNATE NO. 2 INCLUDES INSTALLATION OF PVC PIPE BELOW
BBP BOTTOM OF BASE PLATE GR GRADE REV REVISION LAP SPLICE LENGTH IN INCHES ABBREVIATION FOR "LAP SPLICE" EXISTING LEAK LOCATIONS AT THE AREAS INDICATED ON THE
BC BOLT CIRCLE GRTG GRATING RJ ROUGHENED JOINT DRAWINGS.
BETW BETWEEN GS GRATING SUPPORT RM ROOM 60LS CONCRETE REINFORCING BAR
BLDG BUILDING H HIGH S SOUTH LAP SPLICE B. PROJECT CONDITIONS
BM BEAM HC HOLLOW CORE SCHED SCHEDULE 1. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS. IF
BO BOTTOM OF HEX HEXAGON SD SUBDRAIN EXISTING CONDITIONS DIFFER FROM THOSE SHOWN, THE OWNER
BOC BOTTOM OF CONCRETE HK HOOK SE SOUTHEAST, STEEL EDGE SHALL BE NOTIFIED PRIOR TO CONTINUANCE OF THE WORK.
BOS BOTTOM OF STEEL HR HANDRAIL SECT SECTION LAP SPLICE LENGTH IN INCHES ABBREVIATION FOR "LAP SPLICE" 2. CONTRACTOR SHALL BE RESPONSIBLE TO PROTECT, WORK AROUND,
BRG BEARING HORIZ HORIZONTAL SHT SHEET LAP SPLICE AT RELOCATE, OR TEMPORARILY REMOVE AND REPLACE ALL
BRKT BRACKET HPT HIGH POINT SIM SIMILAR CONTRACTOR'S 48LS CONCRETE REINFORCING BAR OBSTRUCTIONS DURING DEMOLITION FOR, AND CONSTRUCTION, OF
CAP CAPACITY HS HIGH STRENGTH SJ SAWED JOINT OPTION THE NEW STRUCTURE.
CB CORNER BAR HVAC HEATING, VENTILATION, AND SLO SHORT LEG OUTSTANDING
ACO
CC CLEAR COVER AIR CONDITIONING SLP SLOPE C. SUBMITTALS
ABBREVIATION FOR
C/C CENTER TO CENTER IBC INTERNATIONAL BUILDING SLV SLEEVE 1. THE CONTRACTOR SHALL SUBMIT TO, AND RECEIVE APPROVAL FROM
"AT CONTRACTOR'S OPTION"
CE CONCRETE EDGE CODE SP SPACE THE OWNER PRIOR TO FABRICATION/INSTALLATION ALL SHOP
CF CUBIC FEET ID INSIDE DIAMETER SPEC SPECIFICATION BAR SPACING IN INCHES DRAWINGS, PRODUCT DATA, ETC. NECESSARY FOR PERFORMANCE
CHKR CHECKERED IF INSIDE FACE SQ SQUARE OF THE WORK, INCLUDING BUT NOT LIMITED TO:
CIR CIRCLE IJ ISOLATION JOINT SS, SST STAINLESS STEEL ABBREVIATION BAR POSITION ABBREVIATION "FAR FACE" A. CONCRETE ANCHORS
CIRC CIRCULAR INTR INTERIOR ST SINGLE TEE FOR "CORNER BAR" B. EPOXY ADHESIVES
CIRCUM CIRCUMFERENTIAL INVT INVERT STD STANDARD LEG SHOWN, DIMENSION IN INCHES C. PIPE SUPPORT HARDWARE
CIS CENTERED IN SLAB JT JOINT STIF STIFFENER REINFORCING
CIW CENTERED IN WALL K KIP (1000 POUNDS) STIR STIRRUP BAR DESIGNATION LEG PERPENDICULAR TO VIEW,
DIMENSION IN INCHES
CJ CONSTRUCTION JOINT KB KNEE BRACE STL STEEL
CJP COMPLETE JOINT KPL KICK PLATE STR STRAIGHT, STAIR #5CB@12 FF 72X96
CORNER BAR
PENETRATION kg KILOGRAM STRL STRUCTURAL
CL CENTER LINE kN KILONEWTON STRUC STRUCTURE
CLJ CONTROL JOINT KSF KIPS PER SQUARE FOOT SW SOUTHWEST CONCRETE REINFORCING BAR
CLR CLEAR KSI KIPS PER SQUARE INCH SYMM SYMMETRICAL
CM CENTIMETER L ANGLE, LONG T TON, TREAD, THICKNESS, TOP
MATERIALS LEGEND
CMU CONCRETE MASONRY UNIT LAD LADDER TEMP TEMPERATURE, TEMPORARY
CO CONCRETE OPENING LB POUND THK THICK
COL COLUMN LG LENGTH, LONG THD THREAD
CONC CONCRETE LL LIVE LOAD THRU THROUGH STEEL
ALUMINUM
CONN CONNECTION LLH LONG LEG HORIZONTAL T&B TOP AND BOTTOM (LARGE SCALE)
CONSTR CONSTRUCTION LLV LONG LEG VERTICAL TOB TOP OF BOLT
CONT CONTINUOUS LLO LONG LEG OUTSTANDING TOC TOP OF CONCRETE
CONTR CONTRACT LNTL LINTEL TOF TOP OF FLOOR
CHECKERED PLATE WATER
COORD COORDINATE LONG LONGITUDINAL TOG TOP OF GRATING
COR CORNER LPT LOW POINT TOS TOP OF STEEL
CRSI CONCRETE REINFORCING LS LAP SPLICE TOW TOP OF WALL
STEEL INSTITUTE M METER TSF TONS PER SQUARE FOOT CONCRETE EXPANSION MATERIAL
CTR CENTER MATL MATERIAL TRD TREAD
CWB CAPILLARY WATER BARRIER MAX MAXIMUM TYP TYPICAL
CY CUBIC YARD MECH MECHANICAL UON UNLESS OTHERWISE NOTED
CONCRETE
db BAR DIAMETER MEZZ MEZZANINE UNO UNLESS NOTED OTHERWISE
MASONRY UNITS FASTENERS
DBL DOUBLE MFR MANUFACTURE(R) VAR VARIES
DET DETAIL MH MANHOLE VERT VERTICAL
DGA DENSE GRADED AGGREGATE MIN MINIMUM W WEST, WIDE
EARTH
DIA DIAMETER MISC MISCELLANEOUS WD WIDTH
DIAG DIAGONAL MJ MECHANICAL JOINT WF WIDE FLANGE REINFORCING BARS
DIM DIMENSION MK MARK WP WORK POINT
DK DECKING MM MILLIMETER WS WATERSTOP COMPACTED
DL DEAD LOAD MPa MEGAPASCAL WT WEIGHT, WATERTIGHT STRUCTURAL FILL
DN DOWN MS MECHANICAL SPLICE WW WASTEWATER STRUCTURAL STEEL
DT DOUBLE TEE N NORTH WWF WELDED WIRE FABRIC (SMALL SCALE)
DWG DRAWING NA NOT APPLICABLE W/ WITH
GRANULAR FILL
DWL DOWEL NE NORTHEAST W/O WITHOUT
E EAST NF NEAR FACE YD YARD
EA EACH NIC NOT IN CONTRACT & AND
ED EQUIPMENT DRAIN NO NUMBER APPROXIMATELY
GRATING
EF EACH FACE NOM NOMINAL @ AT
EJ EXPANSION JOINT NS NEAR SIDE x BY
EL ELEVATION NTS NOT TO SCALE degrees DEGREE (PLANE ANGLE)
ELEC ELECTRICAL NW NORTHWEST DIAMETER GROUT
EMBED EMBEDMENT OC ON CENTER = EQUAL
EP EQUIPMENT PAD OD OUTSIDE DIAMETER > GREATER THAN
ERCP ELLIPTICAL REINF CONC PIPE OF OUTER FACE < LESS THAN
EQ EQUAL OPNG OPENING # NUMBER, POUND ROCK
EQ SP EQUALLY SPACED OPP OPPOSITE % PERCENT
EQUIP EQUIPMENT OSHA OCCUPATIONAL SAFETY AND
EQUIV EQUIVALENT HEALTH ADMINISTRATION |
no. date by ckd description
0 10/1/26 AMG AMH ISSUED FOR BID |
|
|
|
425 S. WOODS MILL ROAD, SUITE 300
CHESTERFIELD, MO 63017
314-682-1500 |
|
date detailed
JULY 15, 2026 B. BAIR
designed checked
A. GRIFFIN A. HOLMES |
|
Macon County, Illinois
SOUTH WTP INFLUENT FLUME REPAIRS
STRUCTURAL LEGEND AND
ABBREVIATIONS
project contract
200565
drawing rev.
S001 0
sheet of sheets
file 200565_S_FLUME REPAIR_R24.rvt |
| ABBREVIATIONS |
|
|
CONCRETE REINFORCING BAR NOMENCLATURE |
| AA ALUMINUM ASSOCIATION
AASHTO AMERICAN ASSOCIATION OF
STATE HIGHWAY AND
TRANSPORTATION OFFICIALS
AB ANCHOR BOLT
ABT ABOUT
ACI AMERICAN CONCRETE
INSTITUTE
ACO AT CONTRACTOR'S OPTION
ADH ADHESIVE
AGGR AGGREGATE
AHR ANCHOR
AHU AIR HANDLING UNIT
AISC AMERICAN INSTITUTE OF
STEEL CONSTRUCTION
AISI AMERICAN IRON AND STEEL
INSTITUTE
AL, ALUM ALUMINUM
ALTN ALTERNATE
ANSI AMERICAN NATIONAL
STANDARDS INSTITUTE
APPROX APPROXIMATE
ARCH ARCHITECTURAL
ASTM AMERICAN SOCIETY FOR
TESTING AND MATERIALS
INTERNATIONAL
AWS AMERICAN WELDING
SOCIETY
B, BOT BOTTOM
BBP BOTTOM OF BASE PLATE
BC BOLT CIRCLE
BETW BETWEEN
BLDG BUILDING
BM BEAM
BO BOTTOM OF
BOC BOTTOM OF CONCRETE
BOS BOTTOM OF STEEL
BRG BEARING
BRKT BRACKET
CAP CAPACITY
CB CORNER BAR
CC CLEAR COVER
C/C CENTER TO CENTER
CE CONCRETE EDGE
CF CUBIC FEET
CHKR CHECKERED
CIR CIRCLE
CIRC CIRCULAR
CIRCUM CIRCUMFERENTIAL
CIS CENTERED IN SLAB
CIW CENTERED IN WALL
CJ CONSTRUCTION JOINT
CJP COMPLETE JOINT
PENETRATION
CL CENTER LINE
CLJ CONTROL JOINT
CLR CLEAR
CM CENTIMETER
CMU CONCRETE MASONRY UNIT
CO CONCRETE OPENING
COL COLUMN
CONC CONCRETE
CONN CONNECTION
CONSTR CONSTRUCTION
CONT CONTINUOUS
CONTR CONTRACT
COORD COORDINATE
COR CORNER
CRSI CONCRETE REINFORCING
STEEL INSTITUTE
CTR CENTER
CWB CAPILLARY WATER BARRIER
CY CUBIC YARD
db BAR DIAMETER
DBL DOUBLE
DET DETAIL
DGA DENSE GRADED AGGREGATE
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DK DECKING
DL DEAD LOAD
DN DOWN
DT DOUBLE TEE
DWG DRAWING
DWL DOWEL
E EAST
EA EACH
ED EQUIPMENT DRAIN
EF EACH FACE
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRICAL
EMBED EMBEDMENT
EP EQUIPMENT PAD
ERCP ELLIPTICAL REINF CONC PIPE
EQ EQUAL
EQ SP EQUALLY SPACED
EQUIP EQUIPMENT
EQUIV EQUIVALENT |
EW EACH WAY
EXP EXPANSION
EXIST EXISTING
EXT EXTERIOR
FAB FABRICATE
f'c SPECIFIED 28 DAY
COMPRESSIVE STRENGTH
OF CONCRETE
FD FLOOR DRAIN
FDN FOUNDATION
FF FAR FACE
FL FLOOR
FLG FLANGE
f'm SPECIFIED COMPRESSIVE
STRENGTH OF MASONRY
FNSH FINISH
FRP FIBERGLASS REINFORCED
PLASTIC
fs PERMISSIBLE STEEL STRESS
FS FAR SIDE
FT FEET, FOOT
FTG FOOTING
FUT FUTURE
Fy, fy YIELD STRESS
GA GAGE, GAUGE
GAL GALLON
GALV GALVANIZED
GF GRANULAR FILL
GND GROUND
GR GRADE
GRTG GRATING
GS GRATING SUPPORT
H HIGH
HC HOLLOW CORE
HEX HEXAGON
HK HOOK
HR HANDRAIL
HORIZ HORIZONTAL
HPT HIGH POINT
HS HIGH STRENGTH
HVAC HEATING, VENTILATION, AND
AIR CONDITIONING
IBC INTERNATIONAL BUILDING
CODE
ID INSIDE DIAMETER
IF INSIDE FACE
IJ ISOLATION JOINT
INTR INTERIOR
INVT INVERT
JT JOINT
K KIP (1000 POUNDS)
KB KNEE BRACE
KPL KICK PLATE
kg KILOGRAM
kN KILONEWTON
KSF KIPS PER SQUARE FOOT
KSI KIPS PER SQUARE INCH
L ANGLE, LONG
LAD LADDER
LB POUND
LG LENGTH, LONG
LL LIVE LOAD
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LLO LONG LEG OUTSTANDING
LNTL LINTEL
LONG LONGITUDINAL
LPT LOW POINT
LS LAP SPLICE
M METER
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MEZZ MEZZANINE
MFR MANUFACTURE(R)
MH MANHOLE
MIN MINIMUM
MISC MISCELLANEOUS
MJ MECHANICAL JOINT
MK MARK
MM MILLIMETER
MPa MEGAPASCAL
MS MECHANICAL SPLICE
N NORTH
NA NOT APPLICABLE
NE NORTHEAST
NF NEAR FACE
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NS NEAR SIDE
NTS NOT TO SCALE
NW NORTHWEST
OC ON CENTER
OD OUTSIDE DIAMETER
OF OUTER FACE
OPNG OPENING
OPP OPPOSITE
OSHA OCCUPATIONAL SAFETY AND
HEALTH ADMINISTRATION |
OZ OUNCE
Pa PASCAL
PCA PORTLAND CEMENT
ASSOCIATION
PCF POUNDS PER CUBIC FOOT
PCI PRESTRESSED CONCRETE
INSTITUTE, POUNDS PER
CUBIC INCH
PED PEDESTAL
PEN PENETRATE
PERP PERPENDICULAR
PJF PREFORMED JOINT FILLER
PJTN PROJECTION
PL PLATE, PROPERTY LINE
PLCS PLACES
PLF POUNDS PER LINEAR FOOT
PREFAB PREFABRICATED
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PRV PRESSURE RELIEF VALVE
PT POINT
PVC POLYVINYL CHLORIDE
PWS PLASTIC WATERSTOP
R RISERS
RAD RADIUS
RD ROOF DRAIN
REF REFERENCE
REINF REINFORCEMENT
REQD REQUIRED
REV REVISION
RJ ROUGHENED JOINT
RM ROOM
S SOUTH
SCHED SCHEDULE
SD SUBDRAIN
SE SOUTHEAST, STEEL EDGE
SECT SECTION
SHT SHEET
SIM SIMILAR
SJ SAWED JOINT
SLO SHORT LEG OUTSTANDING
SLP SLOPE
SLV SLEEVE
SP SPACE
SPEC SPECIFICATION
SQ SQUARE
SS, SST STAINLESS STEEL
ST SINGLE TEE
STD STANDARD
STIF STIFFENER
STIR STIRRUP
STL STEEL
STR STRAIGHT, STAIR
STRL STRUCTURAL
STRUC STRUCTURE
SW SOUTHWEST
SYMM SYMMETRICAL
T TON, TREAD, THICKNESS, TOP
TEMP TEMPERATURE, TEMPORARY
THK THICK
THD THREAD
THRU THROUGH
T&B TOP AND BOTTOM
TOB TOP OF BOLT
TOC TOP OF CONCRETE
TOF TOP OF FLOOR
TOG TOP OF GRATING
TOS TOP OF STEEL
TOW TOP OF WALL
TSF TONS PER SQUARE FOOT
TRD TREAD
TYP TYPICAL
UON UNLESS OTHERWISE NOTED
UNO UNLESS NOTED OTHERWISE
VAR VARIES
VERT VERTICAL
W WEST, WIDE
WD WIDTH
WF WIDE FLANGE
WP WORK POINT
WS WATERSTOP
WT WEIGHT, WATERTIGHT
WW WASTEWATER
WWF WELDED WIRE FABRIC
W/ WITH
W/O WITHOUT
YD YARD
& AND
APPROXIMATELY
@ AT
x BY
degrees DEGREE (PLANE ANGLE)
DIAMETER
= EQUAL
> GREATER THAN
< LESS THAN
# NUMBER, POUND
% PERCENT |
BAR SPACING IN INCHES
REINFORCING BAR DESIGNATION
BAR POSITION ABBREVIATION
(U.S. CUSTOMARY)
"NEAR FACE"
BAR
#6@18 NF
IDENTIFICATION
36LS
CONCRETE REINFORCING BAR
LAP SPLICE LENGTH IN INCHES
STANDARD OR
90 degrees HOOK
CONCRETE
REINFORCING BAR CONCRETE REINFORCING BAR
STANDARD
180 degrees HOOK
CONCRETE REINFORCING BAR
MECHANICAL
SPLICE
CONCRETE MECHANICAL SPLICE
REINFORCING BAR
LAP SPLICE LENGTH IN INCHES ABBREVIATION FOR "LAP SPLICE"
CONCRETE REINFORCING BAR
60LS
LAP SPLICE
LAP SPLICE LENGTH IN INCHES ABBREVIATION FOR "LAP SPLICE"
LAP SPLICE AT
CONTRACTOR'S CONCRETE REINFORCING BAR
48LS
OPTION
ACO
ABBREVIATION FOR
"AT CONTRACTOR'S OPTION"
BAR SPACING IN INCHES
ABBREVIATION BAR POSITION ABBREVIATION "FAR FACE"
FOR "CORNER BAR"
LEG SHOWN, DIMENSION IN INCHES
REINFORCING
BAR DESIGNATION LEG PERPENDICULAR TO VIEW,
DIMENSION IN INCHES
#5CB@12 FF 72X96
CORNER BAR
CONCRETE REINFORCING BAR |
|
|
|
MATERIALS LEGEND |
|
|
|
STEEL
ALUMINUM
(LARGE SCALE)
CHECKERED PLATE WATER
CONCRETE EXPANSION MATERIAL
CONCRETE
MASONRY UNITS FASTENERS
EARTH
REINFORCING BARS
COMPACTED
STRUCTURAL FILL
STRUCTURAL STEEL
(SMALL SCALE)
GRANULAR FILL
GRATING
GROUT
ROCK |
ABBREVIATIONS CONCRETE REINFORCING BAR NOMENCLATURE
GENERAL REQUIREMENTS:
A. GENERAL
AA ALUMINUM ASSOCIATION EW EACH WAY OZ OUNCE
BAR SPACING IN INCHES
AASHTO AMERICAN ASSOCIATION OF EXP EXPANSION Pa PASCAL REINFORCING BAR DESIGNATION 1. WHERE EXISTING FACILITIES ARE IN OPERATION, CONSULT WITH THE
STATE HIGHWAY AND EXIST EXISTING PCA PORTLAND CEMENT (U.S. CUSTOMARY) BAR POSITION ABBREVIATION OWNER'S REPRESENTATIVE AND COORDINATE ALL WORK IN SUCH A
TRANSPORTATION OFFICIALS EXT EXTERIOR ASSOCIATION "NEAR FACE" MANNER AS TO MINIMIZE EFFECTS ON OWNER'S OPERATIONS.
AB ANCHOR BOLT FAB FABRICATE PCF POUNDS PER CUBIC FOOT 2. CONTRACT DRAWINGS AND SPECIFICATIONS REPRESENT THE
BAR
ABT ABOUT f'c SPECIFIED 28 DAY PCI PRESTRESSED CONCRETE #6@18 NF FINISHED STRUCTURE, DESIGNED TO BE SELF-SUPPORTING AFTER
IDENTIFICATION
ACI AMERICAN CONCRETE COMPRESSIVE STRENGTH INSTITUTE, POUNDS PER ALL PERMANENT STRUCTURAL COMPONENTS AND CONNECTIONS
INSTITUTE OF CONCRETE CUBIC INCH 36LS ARE COMPLETE. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL
ACO AT CONTRACTOR'S OPTION FD FLOOR DRAIN PED PEDESTAL CONCRETE REINFORCING BAR MEANS AND METHODS OF CONSTRUCTION INCLUDING, BUT NOT
ADH ADHESIVE FDN FOUNDATION PEN PENETRATE LAP SPLICE LENGTH IN INCHES LIMITED TO: SHORING AND TEMPORARY BRACING; SITE SAFETY FOR
AGGR AGGREGATE FF FAR FACE PERP PERPENDICULAR ALL PERSONNEL AT THE SITE; PROTECTION OF EXISTING
AHR ANCHOR FL FLOOR PJF PREFORMED JOINT FILLER STRUCTURES AND FACILITIES. IF CONSTRUCTION LOADS EXCEED
AHU AIR HANDLING UNIT FLG FLANGE PJTN PROJECTION STANDARD OR THE DESIGN LOADS INDICATED IN THE CONTRACT DOCUMENTS, THE
AISC AMERICAN INSTITUTE OF f'm SPECIFIED COMPRESSIVE PL PLATE, PROPERTY LINE 90 degrees HOOK CONTRACTOR SHALL BE RESPONSIBLE FOR TEMPORARY SHORING
CONCRETE
STEEL CONSTRUCTION STRENGTH OF MASONRY PLCS PLACES OR OTHER MEANS TO AVOID OVERLOADING THE STRUCTURE AND/OR
REINFORCING BAR CONCRETE REINFORCING BAR
AISI AMERICAN IRON AND STEEL FNSH FINISH PLF POUNDS PER LINEAR FOOT IT'S COMPONENTS. SITE VISITS BY THE OWNER'S REPRESENTATIVE
INSTITUTE FRP FIBERGLASS REINFORCED PREFAB PREFABRICATED SHALL NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITIES
AL, ALUM ALUMINUM PLASTIC PSF POUNDS PER SQUARE FOOT CONTAINED HEREIN.
ALTN ALTERNATE fs PERMISSIBLE STEEL STRESS PSI POUNDS PER SQUARE INCH STANDARD 3. NOTIFY THE OWNER OF ANY DISCREPANCIES DISCOVERED IN THESE
ANSI AMERICAN NATIONAL FS FAR SIDE PRV PRESSURE RELIEF VALVE 180 degrees HOOK DRAWINGS OR WITH OTHER TRADES.
STANDARDS INSTITUTE FT FEET, FOOT PT POINT CONCRETE REINFORCING BAR 4. INSTALL MANUFACTURED ITEMS (PRODUCTS) IN ACCORDANCE WITH
APPROX APPROXIMATE FTG FOOTING PVC POLYVINYL CHLORIDE THE MANUFACTURER'S WRITTEN INSTRUCTIONS AND
ARCH ARCHITECTURAL FUT FUTURE PWS PLASTIC WATERSTOP SPECIFICATIONS.
ASTM AMERICAN SOCIETY FOR Fy, fy YIELD STRESS R RISERS 5. CONTRACTOR MAY SUBSTITUTE ALTERNATE PRODUCTS, WHERE
MECHANICAL
TESTING AND MATERIALS GA GAGE, GAUGE RAD RADIUS PROPRIETARY PRODUCTS ARE SPECIFIED, SUBJECT TO OWNER
SPLICE
INTERNATIONAL GAL GALLON RD ROOF DRAIN CONCRETE MECHANICAL SPLICE APPROVAL.
AWS AMERICAN WELDING GALV GALVANIZED REF REFERENCE REINFORCING BAR 6. BID ALTERNATE NO. 1 INCLUDES REPAIR OF EXISTING FLUME
SOCIETY GF GRANULAR FILL REINF REINFORCEMENT EXPANSION JOINT AS INDICATED ON DRAWINGS.
B, BOT BOTTOM GND GROUND REQD REQUIRED 7. BID ALTERNATE NO. 2 INCLUDES INSTALLATION OF PVC PIPE BELOW
BBP BOTTOM OF BASE PLATE GR GRADE REV REVISION LAP SPLICE LENGTH IN INCHES ABBREVIATION FOR "LAP SPLICE" EXISTING LEAK LOCATIONS AT THE AREAS INDICATED ON THE
BC BOLT CIRCLE GRTG GRATING RJ ROUGHENED JOINT DRAWINGS.
BETW BETWEEN GS GRATING SUPPORT RM ROOM 60LS CONCRETE REINFORCING BAR
BLDG BUILDING H HIGH S SOUTH LAP SPLICE B. PROJECT CONDITIONS
BM BEAM HC HOLLOW CORE SCHED SCHEDULE 1. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS. IF
BO BOTTOM OF HEX HEXAGON SD SUBDRAIN EXISTING CONDITIONS DIFFER FROM THOSE SHOWN, THE OWNER
BOC BOTTOM OF CONCRETE HK HOOK SE SOUTHEAST, STEEL EDGE SHALL BE NOTIFIED PRIOR TO CONTINUANCE OF THE WORK.
BOS BOTTOM OF STEEL HR HANDRAIL SECT SECTION LAP SPLICE LENGTH IN INCHES ABBREVIATION FOR "LAP SPLICE" 2. CONTRACTOR SHALL BE RESPONSIBLE TO PROTECT, WORK AROUND,
BRG BEARING HORIZ HORIZONTAL SHT SHEET LAP SPLICE AT RELOCATE, OR TEMPORARILY REMOVE AND REPLACE ALL
BRKT BRACKET HPT HIGH POINT SIM SIMILAR CONTRACTOR'S 48LS CONCRETE REINFORCING BAR OBSTRUCTIONS DURING DEMOLITION FOR, AND CONSTRUCTION, OF
CAP CAPACITY HS HIGH STRENGTH SJ SAWED JOINT OPTION THE NEW STRUCTURE.
CB CORNER BAR HVAC HEATING, VENTILATION, AND SLO SHORT LEG OUTSTANDING
ACO
CC CLEAR COVER AIR CONDITIONING SLP SLOPE C. SUBMITTALS
ABBREVIATION FOR
C/C CENTER TO CENTER IBC INTERNATIONAL BUILDING SLV SLEEVE 1. THE CONTRACTOR SHALL SUBMIT TO, AND RECEIVE APPROVAL FROM
"AT CONTRACTOR'S OPTION"
CE CONCRETE EDGE CODE SP SPACE THE OWNER PRIOR TO FABRICATION/INSTALLATION ALL SHOP
CF CUBIC FEET ID INSIDE DIAMETER SPEC SPECIFICATION BAR SPACING IN INCHES DRAWINGS, PRODUCT DATA, ETC. NECESSARY FOR PERFORMANCE
CHKR CHECKERED IF INSIDE FACE SQ SQUARE OF THE WORK, INCLUDING BUT NOT LIMITED TO:
CIR CIRCLE IJ ISOLATION JOINT SS, SST STAINLESS STEEL ABBREVIATION BAR POSITION ABBREVIATION "FAR FACE" A. CONCRETE ANCHORS
CIRC CIRCULAR INTR INTERIOR ST SINGLE TEE FOR "CORNER BAR" B. EPOXY ADHESIVES
CIRCUM CIRCUMFERENTIAL INVT INVERT STD STANDARD LEG SHOWN, DIMENSION IN INCHES C. PIPE SUPPORT HARDWARE
CIS CENTERED IN SLAB JT JOINT STIF STIFFENER REINFORCING
CIW CENTERED IN WALL K KIP (1000 POUNDS) STIR STIRRUP BAR DESIGNATION LEG PERPENDICULAR TO VIEW,
DIMENSION IN INCHES
CJ CONSTRUCTION JOINT KB KNEE BRACE STL STEEL
CJP COMPLETE JOINT KPL KICK PLATE STR STRAIGHT, STAIR #5CB@12 FF 72X96
CORNER BAR
PENETRATION kg KILOGRAM STRL STRUCTURAL
CL CENTER LINE kN KILONEWTON STRUC STRUCTURE
CLJ CONTROL JOINT KSF KIPS PER SQUARE FOOT SW SOUTHWEST CONCRETE REINFORCING BAR
CLR CLEAR KSI KIPS PER SQUARE INCH SYMM SYMMETRICAL
CM CENTIMETER L ANGLE, LONG T TON, TREAD, THICKNESS, TOP
MATERIALS LEGEND
CMU CONCRETE MASONRY UNIT LAD LADDER TEMP TEMPERATURE, TEMPORARY
CO CONCRETE OPENING LB POUND THK THICK
COL COLUMN LG LENGTH, LONG THD THREAD
CONC CONCRETE LL LIVE LOAD THRU THROUGH STEEL
ALUMINUM
CONN CONNECTION LLH LONG LEG HORIZONTAL T&B TOP AND BOTTOM (LARGE SCALE)
CONSTR CONSTRUCTION LLV LONG LEG VERTICAL TOB TOP OF BOLT
CONT CONTINUOUS LLO LONG LEG OUTSTANDING TOC TOP OF CONCRETE
CONTR CONTRACT LNTL LINTEL TOF TOP OF FLOOR
CHECKERED PLATE WATER
COORD COORDINATE LONG LONGITUDINAL TOG TOP OF GRATING
COR CORNER LPT LOW POINT TOS TOP OF STEEL
CRSI CONCRETE REINFORCING LS LAP SPLICE TOW TOP OF WALL
STEEL INSTITUTE M METER TSF TONS PER SQUARE FOOT CONCRETE EXPANSION MATERIAL
CTR CENTER MATL MATERIAL TRD TREAD
CWB CAPILLARY WATER BARRIER MAX MAXIMUM TYP TYPICAL
CY CUBIC YARD MECH MECHANICAL UON UNLESS OTHERWISE NOTED
CONCRETE
db BAR DIAMETER MEZZ MEZZANINE UNO UNLESS NOTED OTHERWISE
MASONRY UNITS FASTENERS
DBL DOUBLE MFR MANUFACTURE(R) VAR VARIES
DET DETAIL MH MANHOLE VERT VERTICAL
DGA DENSE GRADED AGGREGATE MIN MINIMUM W WEST, WIDE
EARTH
DIA DIAMETER MISC MISCELLANEOUS WD WIDTH
DIAG DIAGONAL MJ MECHANICAL JOINT WF WIDE FLANGE REINFORCING BARS
DIM DIMENSION MK MARK WP WORK POINT
DK DECKING MM MILLIMETER WS WATERSTOP COMPACTED
DL DEAD LOAD MPa MEGAPASCAL WT WEIGHT, WATERTIGHT STRUCTURAL FILL
DN DOWN MS MECHANICAL SPLICE WW WASTEWATER STRUCTURAL STEEL
DT DOUBLE TEE N NORTH WWF WELDED WIRE FABRIC (SMALL SCALE)
DWG DRAWING NA NOT APPLICABLE W/ WITH
GRANULAR FILL
DWL DOWEL NE NORTHEAST W/O WITHOUT
E EAST NF NEAR FACE YD YARD
EA EACH NIC NOT IN CONTRACT & AND
ED EQUIPMENT DRAIN NO NUMBER APPROXIMATELY
GRATING
EF EACH FACE NOM NOMINAL @ AT
EJ EXPANSION JOINT NS NEAR SIDE x BY
EL ELEVATION NTS NOT TO SCALE degrees DEGREE (PLANE ANGLE)
ELEC ELECTRICAL NW NORTHWEST DIAMETER GROUT
EMBED EMBEDMENT OC ON CENTER = EQUAL
EP EQUIPMENT PAD OD OUTSIDE DIAMETER > GREATER THAN
ERCP ELLIPTICAL REINF CONC PIPE OF OUTER FACE < LESS THAN
EQ EQUAL OPNG OPENING # NUMBER, POUND ROCK
EQ SP EQUALLY SPACED OPP OPPOSITE % PERCENT
EQUIP EQUIPMENT OSHA OCCUPATIONAL SAFETY AND
EQUIV EQUIVALENT HEALTH ADMINISTRATION
gnimliforciM
roF
elacS
sretemilliM
sehcnI
1 2 3 4 5 6 7 8 9 10 11 12 13 14
no. date by ckd description
0 10/1/26 AMG AMH ISSUED FOR BID
A
B
C
D
E
F
G
425 S. WOODS MILL ROAD, SUITE 300
CHESTERFIELD, MO 63017
314-682-1500
H
date detailed
JULY 15, 2026 B. BAIR
designed checked
A. GRIFFIN A. HOLMES
I
Macon County, Illinois
SOUTH WTP INFLUENT FLUME REPAIRS
STRUCTURAL LEGEND AND
J
ABBREVIATIONS
project contract
200565
drawing rev.
S001 0
sheet of sheets
file 200565_S_FLUME REPAIR_R24.rvt
10/1/2026 3:58:15 PM C:\Revit_Projects\200565_S_FLUME REPAIR_R24_bmbair@burnsmcd.com.rvt
| SEE SECTIONAL PLAN
AT ELEV 643 ON DWG S102
EXISTING ACCESS HATCH
BID ALTERNATE NO. 1
EXISTING EXPANSION JOINT
TO BE REPAIRED
SEE SECTIONAL PLAN ON DWG S102
BASIN COMPLEX ENLARGED TOP PLAN
NOT TO SCALE NORTH
THE REGISTRANT OF
THE NEWLY APPLIED
SEAL, DATED 8/XX/26 ,
ONLY ASSUMES RESPONSIBILITY FOR THE CHANGES
AS INDICATED ON BURNS & McDONNELL DRAWING
S101 REVISION 0 . |
no. date by ckd description
0 10/1/26 AMG AMH ISSUED FOR BID |
|
|
|
425 S. WOODS MILL ROAD, SUITE 300
CHESTERFIELD, MO 63017
314-682-1500 |
|
date detailed
JULY 15, 2026 B. BAIR
designed checked
A. GRIFFIN A. HOLMES |
|
Macon County, Illinois
SOUTH WTP INFLUENT FLUME REPAIRS
BASIN COMPLEX
ENLARGED PLAN
project contract
200565
drawing rev.
S101 0
sheet of sheets
file 200565_S_FLUME REPAIR_R24.rvt |
| SEE SECTIONAL PLAN |
| AT ELEV 643 ON DWG S102 |
| BID ALTERNATE NO. 1 |
| EXISTING EXPANSION JOINT |
| TO BE REPAIRED |
| SEE SECTIONAL PLAN ON DWG S102 |
| BASIN COMPLEX |
| ENLARGED PLAN |
SEE SECTIONAL PLAN
AT ELEV 643 ON DWG S102
EXISTING ACCESS HATCH
BID ALTERNATE NO. 1
EXISTING EXPANSION JOINT
TO BE REPAIRED
SEE SECTIONAL PLAN ON DWG S102
BASIN COMPLEX ENLARGED TOP PLAN
NOT TO SCALE NORTH
gnimliforciM
roF
elacS
sretemilliM
sehcnI
1 2 3 4 5 6 7 8 9 10 11 12 13 14
no. date by ckd description
0 10/1/26 AMG AMH ISSUED FOR BID
A
B
C
D
E
F
G
425 S. WOODS MILL ROAD, SUITE 300
CHESTERFIELD, MO 63017
314-682-1500
H
date detailed
JULY 15, 2026 B. BAIR
designed checked
A. GRIFFIN A. HOLMES
I
Macon County, Illinois
SOUTH WTP INFLUENT FLUME REPAIRS
BASIN COMPLEX
J
ENLARGED PLAN
THE REGISTRANT OF
project contract
THE NEWLY APPLIED
200565
SEAL, DATED 8/XX/26 ,
ONLY ASSUMES RESPONSIBILITY FOR THE CHANGES drawing rev.
AS INDICATED ON BURNS & McDONNELL DRAWING S101 0
S101 REVISION 0 .
sheet of sheets
file 200565_S_FLUME REPAIR_R24.rvt
10/1/2026 3:58:16 PM C:\Revit_Projects\200565_S_FLUME REPAIR_R24_bmbair@burnsmcd.com.rvt
| 3
S302
APPROX LOCATION OF BOTTOM SLAB
AND WALL CRACKING, TO BE CRACK
INJECTED (SEE FLUME INTERSECTION
EPOXY CRACK INJECTION NOTES ON
THIS SHEET FOR ADDITIONAL DETAILS)
SECTIONAL PLAN @ EL 643.00'
NORTH
NOT TO SCALE
BID ALTERNATE NO. 1 FLUME EXPANSION JOINT REPAIR NOTES: FLUME INTERSECTION EPOXY CRACK INJECTION NOTES:
1. CONSTRUCTION SEQUENCING: 1. CONTRACTOR AND/OR INSTALLER SHALL HAVE COMPLETED WORK SIMILAR IN MATERIAL,
A. INFLUENT FLUME SHUTDOWN FOR INSTALLATION OF EXPANSION JOINT REPAIRS SHALL DESIGN AND EXTENT TO THAT INDICATED FOR THIS PROJECT WITH A MINIMUM OF FIVE
BE LIMITED TO APPROXIMATELY A FOUR-HOUR WORKING WINDOW. CONTRACTOR SHALL PREVIOUS SUCCESSFUL INSTALLATIONS.
COORDINATE SCHEDULED SHUTDOWN WITH OWNER.
2. CRACKING SHOWN IS CONCEPTUAL IN NATURE. FOR BIDDING PURPOSES, CONTRACTOR
2. INSTALLATION NOTES: SHALL ASSUME 60 LINEAR FEET OF CRACK INJECTION.
A. DETAIL SHALL BE INSTALLED FROM THE INTERIOR OF THE FLUME
B. ALL PRODUCTS SHALL BE NSF 61 PRODUCT CERTIFIED 3. CRACK INJECTION SHALL CONFORM TO ASTM C881 TYPE IV.
C. CONTRACTOR SHALL CLEAN CONCRETE SURFACE AT AREAS IN CONTACT WITH THE
PROPOSED DETAIL TO REMOVE LOOSE CONCRETE, SCALING, DEBRIS AND LAITENANCE. 4. ALL PRODUCTS SHALL BE NSF 61 PRODUCT CERTIFIED.
D. GASKET SHALL BE 14" THICK AND CONFORM TO ASTM D2240 SHORE 50A.
E. GASKET SHALL BE INSTALLED AS ONE CONTINUOUS STRIP FROM SLAB TO WALL 5. ACCEPTABLE PRODUCTS:
SURFACES. A. SIKAFIX HH LV
F. BATTEN BAR SHALL BE SPLICED AS REQUIRED FOR INSTALLATION IN ACCORDANCE WITH B. SEALBOSS FLEXGEL
TYPICAL DETAIL. C. ENGINEER APPROVED EQUAL
G. INSTALL COMPONENTS PER MANUFACTURERS WRITTEN INSTRUCTIONS.
6. CRACK INJECTION SHALL BE PERFORMED FROM THE NEGATIVE (DRY) SIDE OF THE WALL.
BID ALTERNATE NO. 2 NOTES:
1. BID ALTERNATE IS TYPICAL AT BOTH THE NORTH (FLUME INTERSECTION) AND SOUTH 7. INSTALL PER MANUFACTURERS WRITTEN INSTRUCTIONS AND IN ACCORDANCE WITH THE
(EXPANSION JOINT) FLUME REPAIR LOCATIONS. FOLLOWING:
A. CLEAN CRACKS WITH OIL FREE COMPRESSED AIR OR LOW-PRESSURE WATER TO
2. LOCATE PVC PIPE BELOW EXISTING LEAK LOCATIONS. FIELD ROUTE TO NEAREST FLOOR REMOVE LOOSE PARTICLES
DRAIN AT MINIMUM 1/4" PER FOOT. B. CLEAN AREAS TO RECEIVE CAPPING ADHESIVE OF OIL, DIRT, AND OTHER SUBSTANCES
A. AT THE NORTH (FLUME INTERSECTION) LOCATION, A FLOOR DRAIN IS LOCATED BELOW THAT WOULD INTERFERE WITH BOND.
2 THE WORK AREA IN THE SECONDARY SLUDGE CONTROL AREA (FIELD VERIFY). C. PLACE INJECTION PORTS AS RECOMMENDED BY EPOXY MANUFACTURER, BUT NOT TO
B. THE SOUTH (EXPANSION JOINT) LOCATION SHALL BE ROUTED TO LOCATION INDICATED EXCEED 12 INCHES. SEAL INJECTION PORTS IN PLACE WITH CAPPING ADHESIVE.
S301
ON DRAWING S301. D. INJECT EPOXY ADHESIVE, BEGINNING AT WIDEST PART OF CRACK AND WORKING
TOWARD NARROWER PARTS. INJECT ADHESIVE INTO PORTS TO REFUSAL, CAPPING
3. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL PIPE SUPPORTS. SUPPORTS SHALL 304 ADJACENT PORTS WHEN THEY EXTRUDE EPOXY. CAP INJECTED PORTS AND INJECT
STAINLESS STEEL CONFORMING TO MSS-SP 58 WITH 304 STAINLESS STEEL CONCRETE THROUGH ADJACENT PORTS UNTIL CRACK IS FILLED.
ANCHORS. E. AFTER EPOXY ADHESIVE HAS SET, REMOVE INJECTION PORTS AND GRIND SURFACES
SMOOTH.
A
F. SEAL CRACKS AT EXPOSED SURFACES WITH A RIBBON OF CAPPING ADHESIVE AT LEAST
S301 1/4 INCH THICK BY 1 INCH WIDER THAN CRACK.
APPROX LOCATION OF
EXIST FLUME EJ (SEE BID
ALTERNATE NO. 1 FLUME
EXPANSION JOINT REPAIR
NOTES ON THIS SHEET FOR
ADDITIONAL DETAILS)
1
THE REGISTRANT OF
S301
THE NEWLY APPLIED
SEAL, DATED 8/XX/26 ,
ONLY ASSUMES RESPONSIBILITY FOR THE CHANGES
NORTH
TUNNEL SECTIONAL PLAN
AS INDICATED ON BURNS & McDONNELL DRAWING
NOT TO SCALE
S101 REVISION 0 . |
no. date by ckd description
0 10/1/26 AMG AMH ISSUED FOR BID |
|
|
|
425 S. WOODS MILL ROAD, SUITE 300
CHESTERFIELD, MO 63017
314-682-1500 |
|
date detailed
JULY 15, 2026 B. BAIR
designed checked
A. GRIFFIN A. HOLMES |
|
Macon County, Illinois
SOUTH WTP INFLUENT FLUME REPAIRS
BASIN COMPLEX
SECTION PLAN VIEWS
project contract
200565
drawing rev.
S102 0
sheet of sheets
file 200565_S_FLUME REPAIR_R24.rvt |
| APPROX LOCATION OF BOTTOM SLAB |
| AND WALL CRACKING, TO BE CRACK |
| INJECTED (SEE FLUME INTERSECTION |
| EPOXY CRACK INJECTION NOTES ON |
| FLUME INTERSECTION EPOXY CRACK INJECTION NOTES: |
| 1. |
| CONTRACTOR AND/OR INSTALLER SHALL HAVE COMPLETED WORK SIMILAR IN MATERIAL, |
| DESIGN AND EXTENT TO THAT INDICATED FOR THIS PROJECT WITH A MINIMUM OF FIVE |
| PREVIOUS SUCCESSFUL INSTALLATIONS. |
| NFLUENT FLUME SHUTDOWN FOR INSTALLATION OF EXPANSION JOINT REPAIRS SHALL |
|
|
| E LIMITED TO APPROXIMATELY A FOUR |
- |
HOUR WORKING WINDOW. CONTRACTOR SHALL |
| OORDINATE SCHEDULED SHUTDOWN WITH OWNER. |
|
|
| CRACKING SHOWN IS CONCEPTUAL IN NATURE. FOR BIDDING PURPOSES, CONTRACTOR |
| SHALL ASSUME 60 LINEAR FEET OF CRACK INJECTION. |
| ETAIL SHALL BE INSTALLED FROM THE INTERIOR OF THE FLUME |
|
|
| LL PRODUCTS SHALL BE NSF 61 PRODUCT CERTIFIED |
|
|
| ONTRACTOR SHALL CLEAN CONCRETE SURFACE AT AREAS IN CONTACT WITH THE |
|
|
| ROPOSED DETAIL TO REMOVE LOOSE CONCRETE, SCALING, DEBRIS AND LAITENANCE |
|
|
| ASKET SHALL BE 14 |
" |
THICK AND CONFORM TO ASTM D2240 SHORE 50A. |
| ASKET SHALL BE INSTALLED AS ONE CONTINUOUS STRIP FROM SLAB TO WALL |
|
|
| URFACES. |
|
|
| ATTEN BAR SHALL BE SPLICED AS REQUIRED FOR INSTALLATION IN ACCORDANCE WITH |
|
|
| YPICAL DETAIL. |
|
|
| NSTALL COMPONENTS PER MANUFACTURERS WRITTEN INSTRUCTIONS. |
|
|
| ACCEPTABLE PRODUCTS: |
| A. |
| B. |
| C. |
| SIKAFIX HH LV |
| SEALBOSS FLEXGEL |
| ENGINEER APPROVED EQUAL |
| INSTALL PER MANUFACTURERS WRITTEN INSTRUCTIONS AND IN ACCORDANCE WITH THE |
| FOLLOWING: |
| A. |
| CLEAN CRACKS WITH OIL FREE COMPRESSED AIR OR LOW |
- |
PRESSURE WATER TO |
| REMOVE LOOSE PARTICLES |
|
|
| CLEAN AREAS TO RECEIVE CAPPING ADHESIVE OF OIL, DIRT, AND OTHER SUBSTANCES |
|
|
| THAT WOULD INTERFERE WITH BOND. |
|
|
| PLACE INJECTION PORTS AS RECOMMENDED BY EPOXY MANUFACTURER, BUT NOT TO |
|
|
| EXCEED 12 INCHES. SEAL INJECTION PORTS IN PLACE WITH CAPPING ADHESIVE. |
|
|
| INJECT EPOXY ADHESIVE, BEGINNING AT WIDEST PART OF CRACK AND WORKING |
|
|
| TOWARD NARROWER PARTS. INJECT ADHESIVE INTO PORTS TO REFUSAL, CAPPING |
|
|
| ADJACENT PORTS WHEN THEY EXTRUDE EPOXY. CAP INJECTED PORTS AND INJECT |
|
|
| THROUGH ADJACENT PORTS UNTIL CRACK IS FILLED. |
|
|
| AFTER EPOXY ADHESIVE HAS SET, REMOVE INJECTION PORTS AND GRIND SURFACES |
|
|
| SMOOTH. |
|
|
| SEAL CRACKS AT EXPOSED SURFACES WITH A RIBBON OF CAPPING ADHESIVE AT LEAST |
|
|
| 1/4 INCH THICK BY 1 INCH WIDER THAN CRACK. |
|
|
| T THE NORTH (FLUME INTERSECTION) LOCATION, A FLOOR DRAIN IS LOCATED BELOW |
| HE WORK AREA IN THE SECONDARY SLUDGE CONTROL AREA (FIELD VERIFY). |
| HE SOUTH (EXPANSION JOINT) LOCATION SHALL BE ROUTED TO LOCATION INDICATED |
| N DRAWING S301. |
| - |
SP 58 WITH 304 STAINLESS STEEL CONCRETE |
| APPROX LOCATION OF |
| EXIST FLUME EJ (SEE BID |
| ALTERNATE NO. 1 FLUME |
| EXPANSION JOINT REPAIR |
| NOTES ON THIS SHEET FOR |
| ADDITIONAL DETAILS) |
3
S302
APPROX LOCATION OF BOTTOM SLAB
AND WALL CRACKING, TO BE CRACK
INJECTED (SEE FLUME INTERSECTION
EPOXY CRACK INJECTION NOTES ON
THIS SHEET FOR ADDITIONAL DETAILS)
SECTIONAL PLAN @ EL 643.00'
NORTH
NOT TO SCALE
2
S301
A
S301
APPROX LOCATION OF
EXIST FLUME EJ (SEE BID
ALTERNATE NO. 1 FLUME
EXPANSION JOINT REPAIR
NOTES ON THIS SHEET FOR
ADDITIONAL DETAILS)
1
S301
NORTH
TUNNEL SECTIONAL PLAN
NOT TO SCALE
gnimliforciM
roF
elacS
sretemilliM
sehcnI
1 2 3 4 5 6 7 8 9 10 11 12 13 14
no. date by ckd description
0 10/1/26 AMG AMH ISSUED FOR BID
A
B
C
D
E
BID ALTERNATE NO. 1 FLUME EXPANSION JOINT REPAIR NOTES: FLUME INTERSECTION EPOXY CRACK INJECTION NOTES:
1. CONSTRUCTION SEQUENCING: 1. CONTRACTOR AND/OR INSTALLER SHALL HAVE COMPLETED WORK SIMILAR IN MATERIAL,
A. INFLUENT FLUME SHUTDOWN FOR INSTALLATION OF EXPANSION JOINT REPAIRS SHALL DESIGN AND EXTENT TO THAT INDICATED FOR THIS PROJECT WITH A MINIMUM OF FIVE
BE LIMITED TO APPROXIMATELY A FOUR-HOUR WORKING WINDOW. CONTRACTOR SHALL PREVIOUS SUCCESSFUL INSTALLATIONS. F
COORDINATE SCHEDULED SHUTDOWN WITH OWNER.
2. CRACKING SHOWN IS CONCEPTUAL IN NATURE. FOR BIDDING PURPOSES, CONTRACTOR
2. INSTALLATION NOTES: SHALL ASSUME 60 LINEAR FEET OF CRACK INJECTION.
A. DETAIL SHALL BE INSTALLED FROM THE INTERIOR OF THE FLUME
B. ALL PRODUCTS SHALL BE NSF 61 PRODUCT CERTIFIED 3. CRACK INJECTION SHALL CONFORM TO ASTM C881 TYPE IV.
C. CONTRACTOR SHALL CLEAN CONCRETE SURFACE AT AREAS IN CONTACT WITH THE
PROPOSED DETAIL TO REMOVE LOOSE CONCRETE, SCALING, DEBRIS AND LAITENANCE. 4. ALL PRODUCTS SHALL BE NSF 61 PRODUCT CERTIFIED.
D. GASKET SHALL BE 14" THICK AND CONFORM TO ASTM D2240 SHORE 50A.
E. GASKET SHALL BE INSTALLED AS ONE CONTINUOUS STRIP FROM SLAB TO WALL 5. ACCEPTABLE PRODUCTS:
SURFACES. A. SIKAFIX HH LV
F. BATTEN BAR SHALL BE SPLICED AS REQUIRED FOR INSTALLATION IN ACCORDANCE WITH B. SEALBOSS FLEXGEL G
TYPICAL DETAIL. C. ENGINEER APPROVED EQUAL
G. INSTALL COMPONENTS PER MANUFACTURERS WRITTEN INSTRUCTIONS.
6. CRACK INJECTION SHALL BE PERFORMED FROM THE NEGATIVE (DRY) SIDE OF THE WALL.
BID ALTERNATE NO. 2 NOTES:
1. BID ALTERNATE IS TYPICAL AT BOTH THE NORTH (FLUME INTERSECTION) AND SOUTH 7. INSTALL PER MANUFACTURERS WRITTEN INSTRUCTIONS AND IN ACCORDANCE WITH THE
(EXPANSION JOINT) FLUME REPAIR LOCATIONS. FOLLOWING:
A. CLEAN CRACKS WITH OIL FREE COMPRESSED AIR OR LOW-PRESSURE WATER TO
2. LOCATE PVC PIPE BELOW EXISTING LEAK LOCATIONS. FIELD ROUTE TO NEAREST FLOOR REMOVE LOOSE PARTICLES
425 S. WOODS MILL ROAD, SUITE 300
DRAIN AT MINIMUM 1/4" PER FOOT. B. CLEAN AREAS TO RECEIVE CAPPING ADHESIVE OF OIL, DIRT, AND OTHER SUBSTANCES
CHESTERFIELD, MO 63017
A. AT THE NORTH (FLUME INTERSECTION) LOCATION, A FLOOR DRAIN IS LOCATED BELOW THAT WOULD INTERFERE WITH BOND.
314-682-1500
H
THE WORK AREA IN THE SECONDARY SLUDGE CONTROL AREA (FIELD VERIFY). C. PLACE INJECTION PORTS AS RECOMMENDED BY EPOXY MANUFACTURER, BUT NOT TO
B. THE SOUTH (EXPANSION JOINT) LOCATION SHALL BE ROUTED TO LOCATION INDICATED EXCEED 12 INCHES. SEAL INJECTION PORTS IN PLACE WITH CAPPING ADHESIVE.
date detailed
ON DRAWING S301. D. INJECT EPOXY ADHESIVE, BEGINNING AT WIDEST PART OF CRACK AND WORKING
JULY 15, 2026 B. BAIR
TOWARD NARROWER PARTS. INJECT ADHESIVE INTO PORTS TO REFUSAL, CAPPING
3. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL PIPE SUPPORTS. SUPPORTS SHALL 304 ADJACENT PORTS WHEN THEY EXTRUDE EPOXY. CAP INJECTED PORTS AND INJECT
designed checked
STAINLESS STEEL CONFORMING TO MSS-SP 58 WITH 304 STAINLESS STEEL CONCRETE THROUGH ADJACENT PORTS UNTIL CRACK IS FILLED.
A. GRIFFIN A. HOLMES
ANCHORS. E. AFTER EPOXY ADHESIVE HAS SET, REMOVE INJECTION PORTS AND GRIND SURFACES
SMOOTH.
F. SEAL CRACKS AT EXPOSED SURFACES WITH A RIBBON OF CAPPING ADHESIVE AT LEAST
1/4 INCH THICK BY 1 INCH WIDER THAN CRACK.
I
Macon County, Illinois
SOUTH WTP INFLUENT FLUME REPAIRS
BASIN COMPLEX
J
SECTION PLAN VIEWS
THE REGISTRANT OF
project contract
THE NEWLY APPLIED
200565
SEAL, DATED 8/XX/26 ,
ONLY ASSUMES RESPONSIBILITY FOR THE CHANGES drawing rev.
AS INDICATED ON BURNS & McDONNELL DRAWING S102 0
S101 REVISION 0 .
sheet of sheets
file 200565_S_FLUME REPAIR_R24.rvt
10/1/2026 3:58:16 PM C:\Revit_Projects\200565_S_FLUME REPAIR_R24_bmbair@burnsmcd.com.rvt
| NOTES:
1. SEE BID ALTERNATE NO. 1 FLUME EXPANSION JOINT REPAIR
NOTES AND BID ALTERNATE NO. 2 NOTES ON DRAWING S102
FOR ADDITIONAL DETAILS.
8'-0" FV
C
C
"6-'5
2
0
'-0
"
+
/-
CORE DRILL THROUGH
EXIST MASONRY
WALL CORE SHALL BE
C
MINIMUM 8" CLEAR FROM
EDGE OF ROUGH OPENING
OF MASONRY GROUT
EXP JT GASKET
PACK ANNULUS AROUND PIPE
SEE DETAIL THIS DWG
BID ALTERNATE
3" DIA PVC PIPE FIELD ROUTE
TO EXISTING FLOOR DRAIN
SECTION A ELEVATION 1
S102 S102
NOT TO SCALE NOT TO SCALE
1/2" DIA 316 SST WEDGE
EPDM GASKET ANCHOR W/ 2 1/2" (MIN) 1/4" X 2" SST BATTEN BAR
EMBED AT 18" OC (TYP) (SEE SPLICE DETAIL THIS DWG)
4"
REMOVE AND REPLACE LIGHT; EXIST EJ FLOOR DRAIN BEYOND
COORDINATE WITH OWNER
INTERIOR OF FLUME
1" BACKERROD
EXTERIOR OF FLUME
STAINLESS STEEL BID ALTERNATE NO. 2: 3" DIA
PIPE HANGER PVC PIPE FIELD ROUTE TO
3" PVC PIPE
FLOOR DRAIN AS INDICATED
BID ALTERNATE
CAP UPSTREAM END
NO. 2 SEE NOTES
SECTION C
NOT TO SCALE
1'-6" MAX
2" 3" 3" 2"
SST BATTEN BAR
EPDM GASKET
THE REGISTRANT OF
TYPICAL BATTEN BAR SPLICE DETAIL THE NEWLY APPLIED
NOT TO SCALE SEAL, DATED 8/XX/26 ,
ELEVATION 2 ONLY ASSUMES RESPONSIBILITY FOR THE CHANGES
AS INDICATED ON BURNS & McDONNELL DRAWING
S102
NOT TO SCALE
S101 REVISION 0 . |
no. date by ckd description
0 10/1/26 AMG AMH ISSUED FOR BID |
|
|
|
425 S. WOODS MILL ROAD, SUITE 300
CHESTERFIELD, MO 63017
314-682-1500 |
|
date detailed
JULY 15, 2026 B. BAIR
designed checked
A. GRIFFIN A. HOLMES |
|
Macon County, Illinois
SOUTH WTP INFLUENT FLUME REPAIRS
BASIN COMPLEX
EXPANSION JOINT SECTIONS AND PHOTOS
project contract
200565
drawing rev.
S301 0
sheet of sheets
file 200565_S_FLUME REPAIR_R24.rvt |
| SEE BID ALTERNATE NO. 1 FLUME EXPANSION JOINT REPAIR |
| NOTES AND BID ALTERNATE NO. 2 NOTES ON DRAWING S102 |
| FOR ADDITIONAL DETAILS. |
| CORE DRILL THROUGH |
| EXIST MASONRY |
| WALL CORE SHALL BE |
| MINIMUM 8" CLEAR FROM |
| EDGE OF ROUGH OPENING |
| OF MASONRY GROUT |
| PACK ANNULUS AROUND PIPE |
| EXP JT GASKET |
| SEE DETAIL THIS DWG |
| 1/2" DIA 316 SST WEDG |
|
|
| ANCHOR W/ 2 1/2" (MIN) |
|
|
| EMBED AT 18" OC (T |
|
YP) |
|
|
|
| 1/4" X 2" SST BATTEN BAR |
| (SEE SPLICE DETAIL THIS DWG) |
| REMOVE AND REPLACE LIGHT; |
| COORDINATE WITH OWNER |
| STAINLESS STEEL |
| PIPE HANGER |
| BID ALTERNATE NO. 2: 3" DIA |
| PVC PIPE FIELD ROUTE TO |
| FLOOR DRAIN AS INDICATED |
| CAP UPSTREAM END |
| 3" PVC PIPE |
| BID ALTERNATE |
| NO. 2 SEE NOTES |
8'-0" FV
C
C
C
EXP JT GASKET
SEE DETAIL THIS DWG
"6-'5
2
0
'-0
"
+
/-
CORE DRILL THROUGH
EXIST MASONRY
WALL CORE SHALL BE
MINIMUM 8" CLEAR FROM
EDGE OF ROUGH OPENING
OF MASONRY GROUT
PACK ANNULUS AROUND PIPE
BID ALTERNATE
3" DIA PVC PIPE FIELD ROUTE
TO EXISTING FLOOR DRAIN
NOT TO SCALE NOT TO SCALE
1/2" DIA 316 SST WEDGE
EPDM GASKET ANCHOR W/ 2 1/2" (MIN) 1/4" X 2" SST BATTEN BAR
EMBED AT 18" OC (TYP) (SEE SPLICE DETAIL THIS DWG)
4"
REMOVE AND REPLACE LIGHT; EXIST EJ FLOOR DRAIN BEYOND
COORDINATE WITH OWNER
INTERIOR OF FLUME
1" BACKERROD
EXTERIOR OF FLUME
STAINLESS STEEL BID ALTERNATE NO. 2: 3" DIA
PIPE HANGER PVC PIPE FIELD ROUTE TO
3" PVC PIPE
FLOOR DRAIN AS INDICATED
BID ALTERNATE
CAP UPSTREAM END
NO. 2 SEE NOTES
NOT TO SCALE
1'-6" MAX
2" 3" 3" 2"
SST BATTEN BAR
EPDM GASKET
TYPICAL BATTEN BAR SPLICE DETAIL
NOT TO SCALE
NOT TO SCALE
gnimliforciM
roF
elacS
sretemilliM
sehcnI
1 2 3 4 5 6 7 8 9 10 11 12 13 14
no. date by ckd description
NOTES:
1. SEE BID ALTERNATE NO. 1 FLUME EXPANSION JOINT REPAIR
0 10/1/26 AMG AMH ISSUED FOR BID
NOTES AND BID ALTERNATE NO. 2 NOTES ON DRAWING S102
FOR ADDITIONAL DETAILS.
A
B
C
D
SECTION A ELEVATION 1 E
S102 S102
F
G
425 S. WOODS MILL ROAD, SUITE 300
CHESTERFIELD, MO 63017
314-682-1500
H
date detailed
JULY 15, 2026 B. BAIR
designed checked
A. GRIFFIN A. HOLMES
SECTION C
I
Macon County, Illinois
SOUTH WTP INFLUENT FLUME REPAIRS
BASIN COMPLEX
J
EXPANSION JOINT SECTIONS AND PHOTOS
THE REGISTRANT OF
project contract
THE NEWLY APPLIED
200565
SEAL, DATED 8/XX/26 ,
ELEVATION 2 ONLY ASSUMES RESPONSIBILITY FOR THE CHANGES drawing rev.
AS INDICATED ON BURNS & McDONNELL DRAWING S301 0
S102
S101 REVISION 0 .
sheet of sheets
file 200565_S_FLUME REPAIR_R24.rvt
10/1/2026 3:58:17 PM C:\Revit_Projects\200565_S_FLUME REPAIR_R24_bmbair@burnsmcd.com.rvt
| EPOXY CRACK INJECTION
(SLAB AND WALLS - SEE
DRAWING S102)
BID ALTERNATE NO. 2
ROUTE PVC PIPE ALONG
WALL TO FLOOR DRAIN BELOW
CONTRACTOR SHALL FIELD
VERIFY EXISTING FLOOR
DRAIN LOCATION FOR BID
ALTERNATE NO. 2
ELEVATION 3
S102
NOT TO SCALE |
no. date by ckd description
0 10/1/26 AMG AMH ISSUED FOR BID |
|
|
|
425 S. WOODS MILL ROAD, SUITE 300
CHESTERFIELD, MO 63017
314-682-1500 |
|
date detailed
JULY 15, 2026 B. BAIR
designed checked
A. GRIFFIN A. HOLMES |
|
Macon County, Illinois
SOUTH WTP INFLUENT FLUME REPAIRS
BASIN COMPLEX
FLUME INTERSECTION PHOTO
project contract
200565
drawing rev.
S302 0
sheet of sheets
file 200565_S_FLUME REPAIR_R24.rvt |
| EPOXY CRACK INJECTION |
|
| (SLAB AND WALLS |
- |
| DRAWING S102) |
|
EPOXY CRACK INJECTION
(SLAB AND WALLS - SEE
DRAWING S102)
BID ALTERNATE NO. 2
ROUTE PVC PIPE ALONG
WALL TO FLOOR DRAIN BELOW
CONTRACTOR SHALL FIELD
VERIFY EXISTING FLOOR
DRAIN LOCATION FOR BID
ALTERNATE NO. 2
NOT TO SCALE
gnimliforciM
roF
elacS
sretemilliM
sehcnI
1 2 3 4 5 6 7 8 9 10 11 12 13 14
no. date by ckd description
0 10/1/26 AMG AMH ISSUED FOR BID
A
B
C
D
E
F
ELEVATION 3
S102
G
425 S. WOODS MILL ROAD, SUITE 300
CHESTERFIELD, MO 63017
314-682-1500
H
date detailed
JULY 15, 2026 B. BAIR
designed checked
A. GRIFFIN A. HOLMES
I
Macon County, Illinois
SOUTH WTP INFLUENT FLUME REPAIRS
BASIN COMPLEX
J
FLUME INTERSECTION PHOTO
project contract
200565
drawing rev.
S302 0
sheet of sheets
file 200565_S_FLUME REPAIR_R24.rvt
10/1/2026 3:58:18 PM C:\Revit_Projects\200565_S_FLUME REPAIR_R24_bmbair@burnsmcd.com.rvt