4110--BLAST CHILLER
| Location: |
Federal |
| Posted: |
Jul 16, 2026 |
| Due: |
Jul 23, 2026 |
| Agency: |
VETERANS AFFAIRS, DEPARTMENT OF |
| Type of Government: |
Federal |
| Category: |
- 41 - Refrigeration, Air Conditioning and Air Circulating Equip.
|
| Solicitation No: |
36C24526Q0653 |
| Publication URL: |
To access bid details, please log in. |
4110--BLAST CHILLER
Active
Contract Opportunity
Department/Ind. Agency
VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier
VETERANS AFFAIRS, DEPARTMENT OF
Office
245-NETWORK CONTRACT OFFICE 5 (36C245)
Looking for contract opportunity help?
General Information
-
Contract Opportunity Type: Sources Sought (Original)
-
Original Published Date: Jul 16, 2026 02:20 pm EDT
-
Original Response Date: Jul 23, 2026 09:00 am EDT
-
Inactive Policy: Manual
-
Original Inactive Date:
Sep 21, 2026
-
Initiative:
Classification
Description
This RFI is solely for information and planning purposes and does not constitute a solicitation or obligation on the part of the Government. Per FAR 15.201(e), responses to this notice are not considered offers, shall not be used as a proposal, and cannot be accepted by the Government to form a binding contract. Neither unsolicited proposals nor any other kinds of offers will be considered in response to this notice. No evaluation letters and/or results will be issued to the respondents; however, the Government does reserve the right to contact any respondent and/or respondent reference to obtain additional information. At this time, no solicitation exists; therefore, please do not request a copy of the solicitation. Any resulting procurement action will be the subject of a separate, future announcement. The information is provided for discussion purposes and any potential strategy for this acquisition may change prior to any solicitation release. The acquisition strategy, evaluation methodology, contract type, and any other acquisition decisions are to be determined.
STATEMENT OF WORK AND GENERAL SPECIFICATIONS FOR IRINOX BLAST CHILLER.
Specifications
Please see below for salient characteristics.
PALLET AND BULK RACKS
CLIN 0001
REACH-IN BLAST CHILLER
FUNCTIONS:
REACH-IN:
QUANTITY ONE (1)
BLAST CHILLING
SHOCK FREEZING
COLD HOLDING
FROZEN HOLDING
THAWING
PROOFING
REGENERATING
CHOCOLATE MELTING
PASTEURIZATION
DEHYDRATING
LOW-TEMPERATURE COOKING AND AUTOMATIC CHILLING
FREEZING
HOT HOLDING
CAPACITY:
NINE (9) 19 X 26 SHEET PANS
EIGHTEEN (18) 12 X 20 X 2.5 STEAM TABLE PANS
RAPID BLAST CHILL CAPACITY YIELD OF 110LBS FORM FINISHED COOKED TEMP 194 DEGREES FAHRENHEIT TO 37 DEGREES FAHRENHEIT IN APPROX 90 MINUTES AND RAPID SHOCK FREEZE CAPACITY YIELD OF 110LBS FROM FINISHED COOKED TEMP 194 DEGREES FAHRENHEIT TO 0 DEGREES FAHRENHEIT IN APPROX 4 HOURS
FEATURES:
USB HACCP DATA TRANSFER
AUTOMATIC COLD/FROZEN HOLDING
DOOR HINGE LEFT
TOUCH PAD CONTROLS
TEMPERATURE PROBE
AUTOMATIC SANITATION SYSTEM
SELF CONTAINED AIR-COOLED CONDENSING UNIT
FOUR (4) STAINLESS STEEL WIRE SHELVES
6 STAINLESS STEEL ADJUSTABLE LEGS
AISI 304 STAINLESS STEEL INTERNAL AND EXTERNAL MATERIAL
CORD INCLUDED (SUGGESTED PLUG IS L15-30P NEMA)
R290 PROPANE REFRIGERANT
ETL CERTIFIED AND ETL EPH CERTIFIED
REMOVABLE CONDENSATION TRAY
DIMENSIONS:
74 (H) X 40 (W) X 49 (D)
POWER SOURCE:
208V/60/3-PH
WARRANTIES:
TWO (2) YEAR PARTS AND LABOR WARRANTY
FIVE (5) YEAR COMPRESSOR WARRANTY
CROSS CHANNEL REINFORCEMENT
MUST MEET LRFD SPECIFICATIONS
Installation
VA Clarksburg requires a roll-in refrigerator for NFS activation to remodel the kitchen area. Installation will be completed by a contractor awarded through a separate solicitation and is not a part of this requirement.
Delivery Location
Attn: Beth Bova beth@bovacorp.com
BOVA Corp
111 McFann Rd
Valencia, PA 16059
Prior to delivery, Contracting Officer Representative and representative from BOVA Corp shall receive shipping information from Contractor and forward to Logistics personnel at the VAMC Clarksburg.
The Contractor must comply and provide all necessary information to VA Clarksburg and BOVA Corp. Otherwise, the delivery may be refused and require redelivery at no additional cost to the government.
Requested Delivery Date
Delivery of equipment is expected within 60 days ARO.
Safety Data Sheet (SDS)
If applicable, contractor shall provide three (3) copies of each Safety Data Sheet for every product, chemical, etc. SDS sheets shall be provided for any material on the same day those materials arrive on VA property.
Delivery Coordination
Delivery must be coordinated with Beth Bova ( beth@bovacorp.com ) of BOVA Corp, 111 McFann Rd, Valencia PA 16059, 724-898-0288. Delivery coordination should include the COR. Delivery will be made to BOVA Corp, 111 McFann Rd, Valencia PA 16059. A Logistics Representative shall be the only VA entity signing for freight received on this requirement. The VA-issued purchase order number must be included in the packing slip. All items included in the requirement shall be shipped and delivered to site at same time. If deliveries must be broken into several shipments due to size, this must be coordinated in advance with the COR and Beth Bova. Failure to coordinate shipment with COR or Service Line Representative may result in failure to deliver and cause re-scheduling of delivery/freight at no charge to the government.
RESPONSES:Â
Please include descriptive literature demonstrating the product meets or exceeds the brand name product specified above.Â
Please provide any product solution or configuration so long as they are equivalent to the brand name product.
Responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.Â
PLEASE PROVIDE THE FOLLOWING ADDITIONAL INFORMATION:
Full name and address of company
DUNS number/ CAGE Code/ SAM UEI
Business Size
Manufacturer or DistributorÂ
If distributor, provide full name, business size and address of manufacturer.Â
Country of Origin designation for all products.
Technical Literature that clearly shows product(s) are equivalent.
Any additional product solution or configuration that would be beneficial to the functionality of the product line identified. Â
Authorized Distributor Letter Certified by OEM with a current date.Â
Attachments/Links
Contact Information
Contracting Office Address
-
8849 International Drive Suite 215
-
LINTHICUM , MD 21090
-
USA
Secondary Point of Contact
History
-
Jul 16, 2026 02:20 pm EDTSources Sought (Original)
Daily notification on new contract opportunities
With GovernmentContracts, you can:
- Find more opportunities and win more business
- Receive daily alerts for all new bid opportunities
- Get contract opportunities matched to your business
ONE WEEK FREE TRIAL
See also
..., AIR CONDITIONING, AND AIR CIRCULATING EQUIPMENT NAICS Code: 238220 - Plumbing, Heating, ...
COMMERCE, DEPARTMENT OF
Bid Due: 7/29/2026
...Code: N041 - INSTALLATION OF EQUIPMENT- REFRIGERATION, AIR CONDITIONING, AND AIR CIRCULATING EQUIPMENT... ...
INTERIOR, DEPARTMENT OF THE
Bid Due: 8/14/2026
...19.5) Product Service Code: J041 - MAINT/REPAIR/REBUILD OF EQUIPMENT- REFRIGERATION, AIR CONDITIONING..., AND ...
INTERIOR, DEPARTMENT OF THE
Bid Due: 7/30/2026
..., AIR CONDITIONING, AND AIR CIRCULATING EQUIPMENT NAICS Code: 238220 - Plumbing, Heating, ...
ENERGY, DEPARTMENT OF
Bid Due: 8/07/2026
* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.