6515--PORTABLE ECMO HEART-LUNG MACHINE

Location: District of Columbia
Posted: Jul 30, 2025
Due: Aug 6, 2025
Agency: VETERANS AFFAIRS, DEPARTMENT OF
Type of Government: Federal
Category:
  • 65 - Medical, Dental, and Veterinary Equipment and Supplies
Solicitation No: 36C25525Q0519
Publication URL: To access bid details, please log in.
Follow
6515--PORTABLE ECMO HEART-LUNG MACHINE
Active
Contract Opportunity
Notice ID
36C25525Q0519
Related Notice
Department/Ind. Agency
VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier
VETERANS AFFAIRS, DEPARTMENT OF
Office
255-NETWORK CONTRACT OFFICE 15 (36C255)
Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information
  • Contract Opportunity Type: Sources Sought (Original)
  • Original Published Date: Jul 30, 2025 10:15 am CDT
  • Original Response Date: Aug 06, 2025 11:00 am CDT
  • Inactive Policy: Manual
  • Original Inactive Date: Aug 16, 2025
  • Initiative:
    • None
Classification
  • Original Set Aside:
  • Product Service Code: 6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES
  • NAICS Code:
    • 334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing
  • Place of Performance:
    Department of Veterans Affairs Harry S. Truman Memorial Veterans Hospital Columbia , 65201
Description
This is a SOURCES SOUGHT announcement only. It is neither a solicitation announcement nor a request for proposal or quote and does not obligate the Government to award a contract. Responses to this Sources Sought must be in writing. The purpose of this Sources Sought Announcement is for market research, to make appropriate acquisition decisions, and to gain knowledge of potential qualified businesses capable of providing the following:

Portable Heart Lung Machine for Columbia VAMC
*** See Statement of Requirement below for details ***
If this is within your capability, please respond with the information below:
Company Name
Address
Point of Contact
Phone, Fax, and Email
UEI number
GSA Contract (as applicable)
Capability Statement that clearly and convincingly identifies your ability to fulfill this requirement.
Brochures of products being offered to include specifications.
Meet the Buy American statute FAR 52.225-1, where the product is manufactured.
Authorized service provider letter from OEM
Interested firms are reminded that in accordance with FAR 4.12, prospective contractors shall complete electronic annual representations and certifications to be considered for award. In addition, FAR 4.11 states that prospective contractors shall be registered in the System for Award Management (www.SAM.gov) database. All Service-Disabled Veteran Owned Small Businesses (SDVOSB) and Veteran Owned Small Businesses (VOSB) shall be verified in VetCert at https://veterans.certify.sba.gov

Point of Contact for this Sources Sought is:
veronica.flores@va.gov
Department of Veterans Affairs
Network Contracting Office -15
3450 S. 4th Street Trafficway
Leavenworth, KS. 66048Â

STATEMENT OF REQUIREMENTS
GENERAL INFORMATION

1.0 Scope of Work: Harry S Truman VA Hospital (HSTVA) needs new life saving equipment. This equipment is a heart bypass machine. HSTVA current Maquet Cardiohelp lung support systems are more than 10 years old and need to be replaced. HSTVA is requiring two new portable cardio lung supports systems to replace the Cardiohelp Maquet system. The component of the cardio lung supports systems need to include a pump, oxygenator, heat exchanger, cannulas, and tubing.

2.0 Background: The current system in place is a Cardiohelp Maquet System and the need for a new system to replace it is greatly needed. The new system MUST be FDA approved and not have any current recalls.

CONTRACTOR REQUIREMENTS

3.0 Technical Requirements/Tasks:

The system must be able to do the following:

An ECMO machine primarily consists of a mechanical blood pump, a membrane oxygenator (artificial lung), a heat exchanger to regulate blood temperature, and tubing connecting to cannulas (large tubes) that are inserted into the patient's veins and arteries, allowing the machine to draw blood out, oxygenate it, remove carbon dioxide, and then return it to the body; essentially acting as a temporary replacement for the heart and lungs when they cannot function adequately.

The ECMO machine must include:
Pump:
This component forcefully pushes the patient's blood through the circuit.
Oxygenator (membrane lung):
This is where gas exchange occurs, adding oxygen and removing carbon dioxide from the blood.
Heat exchanger:
Ensures the blood is warmed to the patient's body temperature before being returned.
Cannulas:
Large tubes inserted into the patient's blood vessels, one to draw blood out and another to return oxygenated blood.
Tubing:
Connects the cannulas to the pump and oxygenator, allowing blood to flow through the circuit.

4.0 Salient Characteristics:

The Cart must be compact and able to fit through any doorway. Cart must be able to fit into an OR room or normal patient room on the floor such as ICU. (Intensive Care Unit).
It must be easily portable to move and transport patients from hospital to any ambulatory transportation.
Battery Life must be least 90 mins when fully charged.
The unit must include an LED speed indicator integrated into the top of the console to display the speed independently of the touchscreen.
The console must have a weight bearing carrying handle on top of the console that includes an integrated holder that must accept the emergency hand crank.
The console must have a safety bar to protect the console and the attached disposable.
The console must have a pump drive capable of accepting the centrifugal pump of the HLS Set 7.0 or 5.0 disposable circuit
The console must have a combined flow/bubble sensor for flow measurement and arterial bubble monitoring.
The console must have the capability and expandability to add a bubble sensor for venous bubble monitoring if desired.
The console must have a venous probe to measure the venous blood parameters of SV O2, Hb, Hct and temperature. This probe must be able to attach to the Venous Cell of the HLS Set 7.0 or 5.0 disposable circuit.
The console must have an emergency hand crank used in emergency situations to manually drive the HLS Set 7.0 or 5.0 disposable circuit.
The console must have an emergency mode button that can be activated in the event of failure of the touchscreen or other components to operate the disposable and control its speed directly via the rotary knob.
The console must have a Zero Flow mode during which the system must aim at a flow of 0Â l/min by controlling the pump accordingly. In this way, both forward and backward flow can be prevented
The console must have backflow prevention to detect and respond to a backflow of blood. The console must monitor the blood flow, display any alarms and activate the zero-flow mode automatically to prevent any backflow.
The console must have bubble detection to monitor for arterial bubbles. It must have the ability to trigger an intervention and/or an alarm when bubbles are detected. With a user activated intervention, the detection of bubbles by the flow/ bubble sensor must trigger a pump stop.
The console must have the ability to provide Offline Recording to record data in an internal memory and later exported to a USB drive if desired by the user.
The console must have a rotary knob to enable the clinician to change the setpoint speed or the setpoint flow
The console s user interface must be a touch screen and could display:
Flow and LPM
Pressure Internal, Pressure Arterial, Pressure Venous and Dela P
Arterial Temperature and Venous Temperature
SVO2, HB, HCT
Visual Alarms
System Lock status
Battery Status
The console s user interface must also include a separate Keypad next to the touch screen with:
Lock/Unlock LED & button
On/Off LED & button
Zero Flow Mode LED & button
Safety LED button
Battery status LED
The clinician must have the ability to set both alarms and interventions for:
LPM or RPM
Pressure Venous, Pressure Arterial and Pressure Internal.
Arterial bubble sensor
Venous bubble sensor
5.0 Deliverables / Schedule:
Deliverables of this system must be shipped to
800 Hospital Dr Columbia MO 65201. ATT: Warehouse foreman,
All equipment and components must be shipped together.
All equipment and components must be tracked upon shipment and tracking number given to the POC.

Federal Holidays Observed by the VA Medical Center
New Year's Day
Labor DayÂ
Martin Luther King, Jr. Day
Columbus DayÂ
President's DayÂ
Veterans DayÂ
Memorial DayÂ
Thanksgiving DayÂ
JuneteenthÂ
Christmas DayÂ
Independence DayÂ
Â
and any other day specifically designated by the President of the United States.Â
6.0 Training: Travel for training and install must be done by vendor after the delivery receipt of the equipment. No additional fees must be incurred outside the quote. Any fees must be identified in the quote of the procurement not noted later. The vendor must handle all traveling to meet the needs of installation and training.
Vendor must provide training and installation of equipment with local Biomedical rep from HSTVA to ensure equipment is working properly.

7.0 Data Rights: All rights and admin privileges must be handed over to HSTVA upon install of equipment.
Attachments/Links
Contact Information
Contracting Office Address
  • VA MEDICAL CENTER 4101 SOUTH 4TH STREET
  • LEAVENWORTH , KS 66048
  • USA
Primary Point of Contact
Secondary Point of Contact


History
  • Jul 30, 2025 10:15 am CDTSources Sought (Original)
Daily notification on new contract opportunities

With GovernmentContracts, you can:

  • Find more opportunities and win more business
  • Receive daily alerts for all new bid opportunities
  • Get contract opportunities matched to your business
ONE WEEK FREE TRIAL
* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.