VPRO Max2 Low Temp Sterilizers
Active
Contract Opportunity
Notice ID
36C25526Q0168
Related Notice
36C25526Q0168
Department/Ind. Agency
VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier
VETERANS AFFAIRS, DEPARTMENT OF
Office
255-NETWORK CONTRACT OFFICE 15 (36C255)
Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information
  • Contract Opportunity Type: Solicitation (Original)
  • Original Published Date: Jan 30, 2026 08:22 am CST
  • Original Date Offers Due: Feb 10, 2026 11:00 am CST
  • Inactive Policy: 15 days after date offers due
  • Original Inactive Date: Feb 25, 2026
  • Initiative:
    • None
Classification
  • Original Set Aside: No Set aside used
  • Product Service Code: 6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES
  • NAICS Code:
    • 334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing
  • Place of Performance:
    Kansas City , MO 64128
    USA
Description

1. STATEMENT OF WORK

The contractor shall furnish all requisite services, labor, travel, transportation, materials, shipping,

parts, connections, and equipment for the provision and on-site installation of a minimum of three

vaporized hydrogen peroxide Low Temperature Sterilizers. These units are to be located at 4801

Linwood Blvd, Kansas City MO 64128. These low temperature sterilizers are essential for the Sterile

Processing Service (SPS) in reprocessing reusable medical devices (RMDs) employed in invasive

procedures. needed to support Sterile Processing Service (SPS) for reprocessing reuseable medical

devices (RMD) used in invasive procedures. Furthermore, these units are critical for supporting

medical procedures and surgeries and surgeries conducted within the Operating Room, as well as

in various ancillary clinics throughout the KCVA.

The contractor shall additionally furnish training to clinical personnel prior to the utilization of the

equipment. This training is to encompass all tours of duty for the sterile processing department and

necessitate annual retraining on all associated on all associated equipment. Moreover, the

contractor bears the responsibility for the removal and disposal of all debris and packaging

material resulting from the installation of the VPRO MaX2 Low Temp Sterilizers.

2. SPECIFICATIONS

• Three low temperature sterilizers shall have a minimum individual dimensions of Cabinet

(DD): 33 x 40-15/16 x 72” (838 x 1040 x 1829 mm) with Recessed/Cabinet (SD): 33 x

38-5/16 x 72” (838 x 973 x 1829 mm).

o Mounting single door, cabinet

o System installation requires no plumbing, ventilation or air

o supply – only a dedicated electrical connection is needed. A power cord is supplied

for this connection

o The facility space in which the vehicle can occupy is approx. 35’ x 110’.

• Vaporized hydrogen peroxide sterilization processes are particularly suited for sterilizing

heat- sensitive materials because temperatures within the load currently do not exceed

55ºC (131ºF) and sterilization occurs in a low-moisture environment. Heat tolerant devices



and materials can also be indicated for vaporized hydrogen peroxide sterilization processes.

FDA-cleared vaporized hydrogen peroxide sterilizers, either with or without plasma, are

currently available in the United States.

 Per ANSI/AAMI ST58:2013 or subsequent, the sterilizer shall be installed and operated in

an area with a ventilation system capable of at least 10 air exchanges per hour.

 VPRO MaX2 must support utility requirements:

o Current 16 AMP

o Minimum Circuit Breaker 20 AMPS

o Use NEMA L15-20R Plug

o Provide grouped or ganged circuit protection and disconnect for phase 3 power as

required by NEC and local codes.

o Individual power shutoffs near each machine for servicing.

 Shall integrate with the CensiTrac Instrument Tracking System.


Attachments/Links
Contact Information
Contracting Office Address
  • VA MEDICAL CENTER 4101 SOUTH 4TH STREET
  • LEAVENWORTH , KS 66048
  • USA
Primary Point of Contact
Secondary Point of Contact


History

Related Document

Jan 26, 2026[Presolicitation (Original)] VPRO Max2 Low Temp Sterilizers
Daily notification on new contract opportunities

With GovernmentContracts, you can:

  • Find more opportunities and win more business
  • Receive daily alerts for all new bid opportunities
  • Get contract opportunities matched to your business
ONE WEEK FREE TRIAL
* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.