| Location: | Texas |
|---|---|
| Posted: | Feb 25, 2026 |
| Due: | Mar 24, 2026 |
| Agency: | State Government of Texas |
| Type of Government: | State & Local |
| Category: |
|
| Solicitation No: | TAMUS-CSP-02-3434 |
| Publication URL: | To access bid details, please log in. |
TAMUS-CSP-02-3434
Posted
Matt Forester
(713) 780-7563
mforester@shahsmith.com
3/24/2026
2:00 PM
710
21+ Days for Solicitation Notice
CTCD
2/25/2026
2/25/2026 3:27 pm
90903-Administration Of Contracts: Summary Of Work, Quality Control, Project Closeout, Etc.;
90921-Building Construction, Industrial (Warehouse, Etc.);
90924-Building Construction, Commercial And Institutional;
91216-Boring, Drilling, Testing, and Soundings Services, Including Concrete Coring;
91219-Clearing And Grubbing Services;
91220-Construction, Fire Protection (Includes Fire Escapes, Fire And Smoke Barriers, Firestops);
91221-Construction, Energy Related (All Types);
91223-Construction, General (Backfill Services, Digging, Ditching, Road Grading, Rock Stabilization, Etc.);
91227-Construction, Irrigation System;
91232-Construction, Street Lighting;
91345-Construction, Sewer And Storm Drain;
91347-Construction, Sidewalk And Driveway (Includes Pedestrian And Handicap Ramps);
91356-Construction, Utility/Underground Projects;
91361-Construction, Vertical, Concrete, Pour;
District 1,
District 2,
District 3,
District 4,
District 5,
District 6,
District 7,
District 8,
District 9,
District 10,
District 11,
District 12,
District 13,
District 14,
District 15,
District 16,
District 17,
District 18,
District 19,
District 20,
District 21,
District 22,
District 23,
District 24,
District 25
The Texas A&M University System Office of Facilities Planning & Construction is soliciting proposals through the Competitive Sealed Proposal (CSP) process for the Texas A&M University Satellite Utility Plant 1 (SUP1) Expansion in College Station, Texas. This project will add a 2,500-ton centrifugal water-cooled chiller and associated equipment to support the near future utility needs of West Campus, along with 15,100 gross square feet (10,570 assignable square feet at 70% efficiency) to the plant. It should also support future expansion, including one additional 2,500-ton chiller, cooling tower, chilled water pump, and condenser water pump.

With GovernmentContracts, you can:
...Bid Number: P26-058 Bid Title: SCADA SYSTEM DEVELOPMENT FOR STORMWATER PUMP STATIONS Category..., ...
City of Port Arthur
Bid Due: 10/07/2026
...Project ID: Title: Engineering Services for Richland Chambers Lake Pump Station Chemical... Chambers ...
Tarrant Regional Water District
Bid Due: 10/20/2026
...Project ID: Title: Cedar Creek Section 4 Pipeline Replacement and Cedar Creek Lake ...
Tarrant Regional Water District
Bid Due: 9/25/2026
..., and the repair of the existing 5.0 MG ground storage tank at ...
City of Waco
Bid Due: 10/29/2026