FCC Lompoc B&F Project 25Z6AXX Emergency Fire Escape Doors

Location: California
Posted: Nov 10, 2026
Due: Nov 16, 2026
Agency: JUSTICE, DEPARTMENT OF
Type of Government: Federal
Category:
  • 12 - Fire Control Equipment
Solicitation No: 15B61727Q00000002
Publication URL: To access bid details, please log in.
Follow
FCC Lompoc B&F Project 25Z6AXX Emergency Fire Escape Doors
Active
Contract Opportunity
Notice ID
15B61727Q00000002
Related Notice
Department/Ind. Agency
JUSTICE, DEPARTMENT OF
Sub-tier
FEDERAL PRISON SYSTEM / BUREAU OF PRISONS
Office
FCC LOMPOC
Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information View Changes
  • Contract Opportunity Type: Combined Synopsis/Solicitation (Updated)
  • Updated Published Date: Nov 10, 2026 09:34 am PST
  • Original Published Date: Nov 05, 2026 11:51 am PST
  • Updated Date Offers Due: Nov 16, 2026 01:00 pm PST
  • Original Date Offers Due: Nov 16, 2026 01:00 pm PST
  • Inactive Policy: 15 days after date offers due
  • Updated Inactive Date: Dec 01, 2026
  • Original Inactive Date: Dec 01, 2026
  • Initiative:
    • None
Classification
  • Original Set Aside: Total Small Business Set-Aside (FAR 19.5)
  • Product Service Code: 1290 - MISCELLANEOUS FIRE CONTROL EQUIPMENT
  • NAICS Code:
    • 332321 - Metal Window and Door Manufacturing
  • Place of Performance:
    CA 93436
    USA
Description

STATEMENT OF WORK / REQUEST FOR QUOTE

A. INTRODUCTION:





1. The Federal Bureau of Prisons (FBOP), FCC Lompoc, 3901 Klein Blvd., Lompoc, CA 93436, is

seeking quotes from qualified vendors for the supply and delivery of nine (9) complete fire

escape door assemblies, including doors, frames, and all required hardware. The doors are for a

prison facility application and must meet all relevant local, state, and federal fire and life safety

codes.





2. "Equal or Better" Product Substitution: Proposals must meet or exceed the specified product

quality. If an alternative product or component is offered, the vendor must submit all technical

documentation, certifications, and test results for consideration.





3. Government's Right of Final Technical Acceptance: The government retains the sole and final

authority to determine technical acceptance for all submitted products, based on the provided

documentation and compliance with stated standards.





B. SCOPE OF WORK:





1. The vendor shall provide all materials as specified below. All components must be new, U.L.

Listed or labeled by a recognized testing agency acceptable to the Authority Having Jurisdiction

(AHJ) and conform to the standards referenced herein.





C. TECHNICAL SPECIFICATIONS:





TABLE 1: COMPONENTS: All units shall be identical unless otherwise noted.




  • Component

    • Requirement



  • Quantity

    • 9 Complete Door Assemblies



  • Door Size

    • 36" wide x 80" high x 2" thick



  • Door Material

    • Hollow Metal Door, minimum 12 Gauge galvanneal steel



  • Core

    • Ribbed and Insulated (mineral core for fire rating is acceptable/preferred)



  • Fire Rating

    • Rating must be compatible with the wall's fire resistance rating, typically 75% of the wall's rating. See required fire rating for correctional facilities on Table 2



  • Handing

    • 4 Left Hand Outswing, 5 Right Hand Outswing.



  • Frame Material

    • Minimum 12 Gauge galvanneal steel, fire-rated and labeled



  • Frame Type

    • Knock-down (KD) for drywall/unit masonry or welded for masonry. Frames are





to be prepared for 80 series lock, keyed 2 sides strike, surface pull on both

sides and prepped for PA closer.




  • Finish

    • Factory primed for field painting







TABLE 2: FIRE RATING:





The complete door assembly (door, frame, and all hardware) shall be 90 minutes fire rated. This rating

must be compatible with the fire-resistance rating of the specific wall assembly in which the door will be

installed, as dictated by the building's fire safety plan and local code requirements.

Category Requirement Description Applicable Standards &

Agencies




  • Listing & Labeling

    • All components must be listed and labeled by a recognized third-party testing agency acceptable to the Authority Having Jurisdiction (AHJ).

    • Underwriters Laboratories (UL), Intertek (WH), Factory Mutual (FM)



  • Testing Standard

    • Assemblies shall be tested under positive pressure conditions.





NFPA 252, ANSI/UL 10C




  • Labeling Visibility

    • A permanent, legible fire rating label must be affixed to both the door and the frame and remain visible after installation for inspection purposes.

    • N/A



  • Code Compliance

    • Vendor must confirm that all components, when installed as an assembly, comply with relevant building and safety codes for correctional facilities (Group I-3 Occupancies, IBC).

    • NFPA 80 (Standard for Fire Doors and Other Opening Protectives)

    • International Building Code (IBC)







TABLE 3: HARDWARE SPECIFICATIONS:





All hardware must be "listed" or "labeled" for use on a fire-rated assembly, compatible with the specified fire rating, and factory-prepped for ANSI/BHMA Grade 1 standards.





Item Requirement Quantity

per Door

Notes




  • Hinges

    • Heavy-duty steel ball bearing hinges, UL Listed

    • 3



  • Exit Device

    • Panic Hardware/Fire Exit Hardware (rim or mortise type) self-latching

    • 1 set

    • Must be a crossbar or touch bar device, operable with an applied force of 15 lbs or less.



  • Locking

    • Must be openable from the egress side at all times without special knowledge or tools. Keyed access from the exterior is permitted.

    • 1 set

    • 80 series lock, keyed 2 sides strike, surface pull on both sides and prepped for PA closer.



  • Door Closer

    • Heavy-duty, adjustable, surface-mounted, UL Listed

    • 1 unit

    • Must be self-closing and ensure positive latching.



  • Seals

    • Smoke and draft control gasketing/seals

    • 1 set

    • Required for a complete smoke-rated assembly.



  • Threshold

    • [Specify if required, e.g., 1/2" beveled aluminum, non-combustible]

    • 1 unit (if required)







D. CODE AND STANDARD REQUIREMENTS:





1. All supplied materials and the complete assembly must comply with the latest editions of the

following codes and standards (or local equivalents as adopted by the AHJ):




  • NFPA 80: Standard for Fire Doors and Other Opening Protectives

  • NFPA 101: Life Safety Code

  • International Building Code (IBC)

  • International Fire Code (IFC)

  • OSHA requirements for exit routes

  • UL 10C or NFPA 252: Standard for positive pressure fire testing of door assemblies

  • UL 1784: Standard for Air Leakage Tests of Door Assemblies (if smoke rating is required)





2. Vendors must confirm that all components, when installed as an assembly, will bear a permanent,

legible label from a recognized third-party testing agency (e.g., UL, Intertek/WH, FM).





E. SUBMISSION REQUIREMENTS:





1. Itemized pricing for doors, frames, hardware, and any included accessories.

2. Proposed lead time for manufacturing and delivery to FCC Lompoc

3. Confirmation of compliance with all referenced codes and standards.

4. Cut sheets/product data for all proposed items.





F. DELIVERY OF MATERIALS:





1. Deliveries shipped directly to FCC LOMPOC can only be received between 7:30 a.m. and 2:00

p.m., Monday through Friday, excluding Federal Holidays.





2. POC: Mr. Fernando Pena, BOP Engineering Technician, FXPena@bop.gov, or 805-735-2771





3. FBOP will be responsible for receiving or signing deliveries.





4. FCC LOMPOC will provide resources for loading and unloading materials or equipment upon

arrival.


Attachments/Links
Contact Information
Contracting Office Address
  • 3901 KLEIN BOULEVARD
  • LOMPOC , CA 93436
  • USA
Primary Point of Contact
Secondary Point of Contact


History

Related Document

Nov 5, 2026[Combined Synopsis/Solicitation (Original)] FCC Lompoc B&F Project 25Z6AXX Emergency Fire Escape Doors
Daily notification on new contract opportunities

With GovernmentContracts, you can:

  • Find more opportunities and win more business
  • Receive daily alerts for all new bid opportunities
  • Get contract opportunities matched to your business
ONE WEEK FREE TRIAL

See also

Follow UPDATE Request for Bids for Food Trucks at Rodeo Beach within Golden

INTERIOR, DEPARTMENT OF THE

Bid Due: 12/31/2026

GFO-26-302 - Food Production Investment Program 2026 Solicitation Type Grant Funding Opportunity Solicitation

California Energy Commission

Bid Due: 12/17/2026

Opportunity ID 224081 Organization City of Los Angeles Department Transportation Stage Open Contact

City of Los Angeles

Bid Due: 12/10/2026

Project ID: Title: 2026 Sewer Rehabilitation Project Addenda: 0 Release Date: 9/17/2026 Due

City of American Canyon

Bid Due: 1/12/2027

* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.