CONDITION OF MASONRY
CONDITION AT ENTRY SILL
PATCH/REPAIR EXISTING SILL
CONDITION AT CORNICE END CAP
REMOVE EXISTING LIGHT
FIXTURES. PROVIDE FIXTURE MAYA
OUTDOOR BY CANARM OR
APPROVED EQUAL
234 ~ CHINO BARBER SHOP 2
PAINT SCHEDULE
TAG LOCATION
PT-1 ROOF CORNICE
PT-2 ROOF BRACKETS
PT-3 WINDOW TRIM
PT-4 SHUTTERS
PT-5 DOOR
PT-6 DOOR TRIM
PT-7 STUCCO WALL
COLOR & MANUFACTURER
TBD
TBD
TBD
TBD
TBD
TBD
TBD
GENERAL MASONRY CLEANING NOTES
1. PROTECT NON-MASONRY SURFACES INCLUDING BUT NOT
LIMITED TO ROOFS, WINDOWS UNIT, GLASS, FRAMES, TRIM,
AND ANY ELEMENTS ADJACENT TO MASONRY WORK.
2. CONTRACTOR SHALL PROVIDE ONE SAMPLE AREA OF EACH
CLEANING METHOD IN A LIMITED VISIBILITY LOCATION
WHERE DIRECTED BY THE OWNER AND ARCHITECT. UPON
APPROVAL OF THE CLEANING METHODS, SAMPLE AREA SHALL
BE MAINTAINED FOR THE DURATION OF THE WORK AND WILL
SERVE AS REFERENCE FOR THE EXECUTION OF THE
REMAINDER OF WORK. UPON COMPLETION OF OVERALL
WORK, SAMPLE AREA MAY BE RE-TOUCHED IF THE COURSE
OF WORK REVEALS METHODS WITH IMPROVED RESULTS.
3. CONTRACTOR SHALL MONITOR CONDITIONS INTERIOR AND
EXTERIOR OF THE BUILDING DURING THE APPLICATION OF
WATER TO ASSURE THAT CLEANING DOES NOT CAUSE
WATER ENTRY TO THE INTERIOR AS WELL AS PROPER
CONTROL OF RUNOFF WATER TO THE EXTERIOR. IF
UNDESIRABLE CONDITIONS OCCUR DURING CLEANING,
WATER APPLICATION SHALL BE STOPPED UNTIL SAID
CONDITION IS RESOLVED.
MASONRY CLEANING
CLEAN EXTERIOR MASONRY IN ITS ENTIRETY USING LOW
PRESSURE POTABLE WATER. AVOID USING HIGH-PRESSURE
EQUIPMENT OR HARSH CHEMICALS DURING THIS LEVEL OF
CLEANING.
REPAIR STONE SILL
REPLACE EXISTING TRIM TO MATCH
ADJACENT ORIGINAL PROFILES
WOOD CORNICE ELEMENTS SHALL BE
STRIPPED TO SOUND WOOD. CRACKED WOOD
SHALL BE FILLED, PATCHED, PRIMED, AND
PAINTED 2 FINISH COATS, COLOR TO BE
SELECTED BY ARCHITECT.
CORNICE: PT-1
BRACKETS: PT-2
WOOD WINDOW ELEMENTS AND SHUTTERS
SHALL BE STRIPPED TO SOUND WOOD.
CRACKED WOOD SHALL BE FILLED, PATCHED,
PRIMED, AND PAINTED 2 FINISH COATS,
COLOR TO BE SELECTED BY ARCHITECT.
TYPICAL AT SECOND AND THIRD FLOOR
WINDOWS.
WINDOW TRIM: PT-3
SHUTTERS: PT-4
WOOD CORNICE ELEMENTS SHALL BE
STRIPPED TO SOUND WOOD. DAMAGED
WOOD SHALL BE FILLED, PATCHED, PRIMED,
AND PAINTED 2 FINISH COATS, COLOR TO BE
SELECTED BY ARCHITECT.
CORNICE: PT-1
BRACKETS: PT-2
REMOVE EXISTING AC UNIT AND ATTACHMENTS.
INFILL TO MATCH EXISTING, INTERIOR AND
EXTERIOR. PAINT TO MATCH ADJACENT WALL
COLOR SELECTED BY ARCHITECT
REMOVE EXISTING WINDOW GRATES
AND MOUNTING ELEMENTS. PATCH
AND REPAINT EXTERIOR FINISH TO
MATCH ADJACENT COLOR
2
A-201
CONDITION AT CORNICE
±14'-0"
GOOSENECK LIGHT FIXTURES, TYP 3: "FIRE CHIEF SIGN
LIGHT" BY BARN LIGHT OR EQUAL
PAINTED WOOD SIGN BAND. REMOVE EXISTING SIGNAGE
HANDPAINTED LETTERING / SIGN CONTENT BY OWNER
REMOVE EXISTING LIGHT FIXTURE. PATCH AND REPAINT
TO MATCH EXISTING EXTERIOR FINISH.
WOOD DOOR, AND JAMB/FRAME ELEMENTS
SHALL BE STRIPPED TO SOUND WOOD.
CRACKED WOOD SHALL BE FILLED,
PATCHED, PRIMED, AND PAINTED 2 FINISH
COATS, COLOR TO BE SELECTED BY
ARCHITECT
DOOR: PT-5
WOOD TRIM: PT-6
ENLARGED GROUND FLOOR ELEVATION 2
NOT TO SCALE A-201
REPLACE PORTION OF WOOD
CORNICE TO MATCH EXISTING
ADJACENT. PRIME & PAINT. SEE
PHOTO
REPAIR/REPLACE WOOD SOFFIT.
PRIME & REPAINT
CLEAN MASONRY IN ITS ENTIRETY
REPAIR WOOD CORNICE END CAP. IF
REPLACEMENT IS REQUIRED, MATCH
EXISTING. PAINT WOOD ELEMENTS TO
MATCH EXISTING
REPLACE DOWNSPOUT
SECTION. TIE INTO EXISTING
DOWNSPOUT. MATCH COLOR,
MATERIAL, AND PROFILE
REMOVE EXISTING WINDOW GRATES
AND MOUNTING ELEMENTS. PATCH
AND REPAINT EXTERIOR FINISH TO
MATCH ADJACENT COLOR
EXISTING STUCCO WALL FINISH,
PAINTED 2 FINISH COATS, COLOR TO
BE SELECTED BY ARCHITECT
BID SET
ISSUE DATE: 06/04/2026
LANDMARKS PROJECT NO.
224020
NOT FOR CONSTRUCTION ARCHITECT OF RECORD: LGA PARTNERS
FACADE
IMPROVEMENTS
234 W MAIN STREET
NORRISTOWN, PA 19401
MUNICIPALITY OF NORRISTOWN
REVISIONS
NO.
DATE
DESCRIPTION
REMOVE EXISTING SECURITY DOOR
AND FRAME. PATCH AND REPAINT
EXTERIOR FINISH
FRONT ELEVATION (W MAIN STREET) 1
NOT TO SCALE A-201
NOTE: DO NOT SCALE FROM DRAWINGS.
VERIFY ALL DIMENSIONS ON SITE.
ELEVATION AND DETAILS
A-201