AIR COMPRESSOR CHILLER

Location: Oklahoma
Posted: Sep 9, 2025
Due: Sep 16, 2025
Agency: DEPT OF DEFENSE
Type of Government: Federal
Category:
  • 36 - Special Industry Machinery
Solicitation No: W911S225U1837
Publication URL: To access bid details, please log in.
Follow
AIR COMPRESSOR CHILLER
Active
Contract Opportunity
Notice ID
W911S225U1837
Related Notice
Department/Ind. Agency
DEPT OF DEFENSE
Sub-tier
DEPT OF THE ARMY
Major Command
AMC
Sub Command
ACC
Sub Command 2
MISSION INSTALLATION CONTRACTING COMMAND
Sub Command 3
419TH CSB
Office
W6QM MICC-FT DRUM
Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information
  • Contract Opportunity Type: Combined Synopsis/Solicitation (Original)
  • Original Published Date: Sep 09, 2025 06:23 am CDT
  • Original Date Offers Due: Sep 16, 2025 11:00 am CDT
  • Inactive Policy: Manual
  • Original Inactive Date: Sep 09, 2026
  • Initiative:
    • None
Classification
  • Original Set Aside: Total Small Business Set-Aside (FAR 19.5)
  • Product Service Code: 3695 - MISCELLANEOUS SPECIAL INDUSTRY MACHINERY
  • NAICS Code:
    • 333912 - Air and Gas Compressor Manufacturing
  • Place of Performance:
    McAlester Army Ammunition Plant 1 C-Tree Road, Building 6 McAlester, OK 74501 74501
Description
CHILLER UNIT COMPONENTS FOR 760 CFM SULLAIRE AIR COMPRESSOR1 Model AFC44CB-0C41 General Air Products, Inc. Fluid Cooler at 427,538 Btu/Hr total at a flow of 46.4 gpm total with a 5� F approach, 40% propylene glycol solution and a design ambient of 85� F. Coolers will have A350 Johnson controls for fan cycling and 460v/3/60Hz electrical equipment and offer the following features as standard 4 direct drive 1.5 HP propeller fans with vinyl coated fan guards, weather resistant motors with sealed bearings, internal overload protection, and hardware designed for outdoor duty. Access door panels at each fan motor, vent and drain connection and corrosion resistant construction.1 Model FPSBD44A, 3 HP Fluid Pumping Station for 40 PSI and to be wired 460v/3/60Hz with a 120v control circuit. Pumping station to be completely pre-plumbed and pre-wired with TEFC type motors and a NEMA 4 steel control panel. The unit will have a close-coupled centrifugal pump with expansion tank, temperature and pressure gauges, check valves and shut off safety valves plus a steel base as standard. This unit will be a Duplex design.1 Model MVD75, 1.5? 75 degree thermostatic mixing valve.1 TC3060, Trim Cooler, to trim system on days over 85� F ambient.1 Model WV125, 1.25? Trim water modulating valve. The following document provides the requirements and specifications for the chiller unit for 2 Sullaire air compressors. Applicable Documents 1. Standards and Regulations: 2. Additional Documents Requirements 3. General Requirements This section provides the design specification requirements for the B190 compressor chiller unit. a. The chiller unit will need to be sized to provide water cooling to the heat exchangers on a 150 HP, 100 PSI Gardner Denver screw compressor that can produce 760 CFM. i. The compressors are plumbed into an oil cooler for the outgoing compressed air This section provides specific requirements for the B190 compressor chiller unit equipment requested. a. Fluid Fan Bank Cooler i. General Air Products Model AFC44CB-0C41, or equivalent ii. 427,538 Btu/ Hr total at flow rate of 46.4 GPM iii. To be operated with a 40% propylene glycol solution iv. A350 Johnson controls for fan cooling v. 460V/ 3 Ph/ 60 Hz vi. 4 direct drive 1.5 hp propeller fans with fan guards vii. Sealed bearings viii. Internal overload protection ix. Access panels for each motor x. Vent and drain connections b. Duplex Pumping station i. General Air Products Model FPSBD44A, or equivalent ii. 3 HP for 40 PSI iii. 460V/3Ph/60 Hz iv. 120V control circuit v. Pre-plumbed and wired with TEFC motors vi. NEMA 4 control panel vii. Close-coupled centrifugal pump with expansion tank\ viii. Temperature and pressure gauges ix. Check valves and shut-off valves c. 1.5? 75 degree Thermostatic Mixing valve i. General Air Products Model MVD75, or equivalent d. Trim Cooler for days over 85 degF ambient i. General Air Products Model TC3060, or equivalent e. Trim Water Modulating Valve i. General Air Products Model WV125, or equivalent Proposal, Reviews, Drawings, Documentation, and Data
Attachments/Links
Contact Information
Contracting Office Address
  • MICC FORT DRUM 4205 PO VALLEY RD
  • FORT DRUM , NY 13602-5220
  • USA
Primary Point of Contact
Secondary Point of Contact


History
  • Sep 09, 2025 06:23 am CDTCombined Synopsis/Solicitation (Original)
Daily notification on new contract opportunities

With GovernmentContracts, you can:

  • Find more opportunities and win more business
  • Receive daily alerts for all new bid opportunities
  • Get contract opportunities matched to your business
ONE WEEK FREE TRIAL
* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.