Kirk Hangar Foundation Installation - Addendum #6

Location: Illinois
Posted: Mar 10, 2026
Due: Mar 13, 2026
Agency: Qual Cities International Airport
Type of Government: State & Local
Category:
  • Y - Construction of Structures and Facilities
Publication URL: To access bid details, please log in.

Kirk Hangar Foundation Installation – Addendum #6

Attachment Preview

ADDENDUM NO. 6
Invitation for Bids
Kirk Hangar Foundation Installation
This Addendum No. 6 is hereby issued to modify and supplement the Invitation for Bids (“IFB”) dated
January 28, 2026, for the Kirk Hangar Foundation Installation project. All provisions of the IFB not
expressly modified herein shall remain in full force and effect.
1. Addition of Door Rail Foundation Shop Drawings Exhibit
The IFB is hereby amended to include a Door Rail Foundation Shop Drawings Exhibit,
identified as Schedule E.
Schedule E is provided for informational and coordination purposes and is intended to assist
bidders. Bidders are responsible for verifying all site conditions and dimensions as required by
the IFB.
2. Incorporation by Reference
Schedule E is hereby incorporated into the IFB by reference.
3. Acknowledgment
Bidders must acknowledge receipt of this Addendum No. 6 on the Bid Cover Page / Signature
Affidavit. Failure to acknowledge this Addendum may result in rejection of the bid as non-responsive.
Issued By:
Benjamin Leischner, A.A.E
Executive Director
Metropolitan Airport Authority of Rock Island County, Illinois
Dated: March 10, 2026
SCHEDULE E
DESIGN LOAD CRITERIA:
1. AS REQUIRED BY ROCK ISLAND COUNTY, IL, ENGINEERING DESIGN IS BASED ON AND ACCORDANCE
WITH THE FOLLOWING CODE(S):
A.
INTERNATIONAL BUILDING CODE - 2012
2. DESIGN LOADS:
A.
SUPERIMPOSED ROOF DEAD LOAD ................................... BY METAL BUILDING MNFR.
FLOOR LIVE LOAD .................................................................. 250 PSF
B.
SNOW LOAD:
1) GROUND SNOW LOAD (Pg) .............................................. 20 PSF
2) SNOW EXPOSURE FACTOR (Ce) ..................................... 1.0
3) SNOW IMPORTANCE FACTOR ......................................... 1.00
4) THERMAL FACTOR (Ct) ..................................................... 1.0
C.
WIND LOAD:
1) BASIC WIND SPEED (3 SEC GUST) ................................. 115 MPH
2) WIND IMPORTANCE FACTOR ...........................................1.0
3) BUILDING CATEGORY ....................................................... II
4) WIND EXPOSURE ............................................................... C
5) INTERNAL PRESSURE COEFFICIENT .............................. ±0.18
D.
SEISMIC:
1) SEISMIC DESIGN CATEGORY ........................................... B
2) SEISMIC IMPORTANCE FACTOR ...................................... 1.00
3) SPECTRAL RESPONSE COEFFICIENTS
Ss .......................................................................................... 0.19
S1 .......................................................................................... 0.085
4) SITE CLASS ......................................................................... D
5) BASIC SEISMIC FORCE RESISTING SYSTEMS DESCRIPTION:
STEEL SYSTEMS NOT SPECIFICALLY DETAILED FOR SEISMIC RESISTANCE
RESPONSE MODIFICATION FACTOR (R) USED ................3.0
GENERAL REQUIREMENTS:
1. DEFINITIONS:
A.
ENGINEER: REFERENCES OF THE STRUCTURAL DRAWINGS TO 'ENGINEER' MEAN THE
STRUCTURAL ENGINEER OF RECORD. OTHER ENTITIES ARE SPECIFICALLY NOTED AS
"CONTRACTORS ENGINEER", "MECHANICAL ENGINEER", ETC.
2. UNDERGROUND UTILITIES: LOCATE EXISTING UTILITIES, AND NOTIFY ENGINEER OF EXISTING
UTILITIES OR SUBGRADE CONDITIONS WHICH INTERFERE WITH WORK.
3. EXISTING STRUCTURES:
A.
CONTRACT DOCUMENTS HAVE BEEN PREPARED USING AVAILABLE DRAWINGS
AND SITE OBSERVATION AS PERMITTED BY ACCESS RESTRICTIONS DURING DESIGN.
B.
DURING CONSTRUCTION, THE CONTRACTOR MAY ENCOUNTER EXISTING CONDITIONS
WHICH ARE NOT NOW KNOWN OR ARE AT VARIANCE WITH PROJECT DOCUMENTATION
(DISCOVERY). CONTRACTOR SHALL NOTIFY THE ENGINEER OF ALL CONDITIONS NOT
PER THE CONTRACT DOCUMENTS. EXAMPLES INCLUDE:
- SIZES OR DIMENSIONS OTHER THAN THOSE SHOWN.
- DAMAGE OR DETERIORATION TO MATERIALS OR COMPONENTS.
- ITEMS NOTED AS EXISTING ON THE DRAWINGS BUT NOT FOUND IN THE FIELD.
C.
PREPARE DIMENSIONAL DRAWINGS OF ALL DISCOVERED ITEMS.
D.
CONTRACTOR SHALL FIELD VERIFY ALL EXISTING STRUCTURAL CONDITIONS PRIOR TO
SUBMITTING SHOP DRAWINGS.
E.
CONTRACTOR SHALL MAKE ALLOWANCE FOR THE RESOLUTION OF SUCH DISCOVERIES
IN THE CONSTRUCTION SCHEDULE.
4. USE OF DRAWINGS:
A.
DO NOT SCALE DRAWINGS.
B.
WHERE DISCREPANCIES OCCUR BETWEEN PLANS, DETAILS AND GENERAL NOTES, THE MORE STRINGENT
REQUIREMENTS SHALL GOVERN. DETAILS ON DRAWINGS TAKE PRECEDENCE OVER GENERAL NOTES AND
TYPICAL DETAILS. DETAILS NOTED TYPICAL APPLY TO ALL SIMILAR CONDITIONS. WHERE NO SPECIFIC
DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ELSEWHERE ON THE PROJECT.
5. TEMPORARY CONDITIONS:
A.
THE STRUCTURE IS DESIGNED TO FUNCTION AS A UNIT UPON COMPLETION. THE CONTRACTOR IS
RESPONSIBLE FOR FURNISHING ALL TEMPORARY BRACING AND/OR SUPPORT THAT MAY BE
REQUIRED AS THE RESULT OF THE CONTRACTOR'S CONSTRUCTION METHODS AND/OR SEQUENCES.
B.
CONTRACTOR'S CONSTRUCTION AND/OR ERECTION SEQUENCES SHALL RECOGNIZE AND CONSIDER
THE EFFECTS OF THERMAL MOVEMENTS OF STRUCTURAL ELEMENTS DURING THE CONSTRUCTION
PERIOD.
6. SUBMITTALS AND SUBSTITUTIONS:
A.
SUBMITTALS:
1) IF THE CONTRACTOR REQUESTS A CHANGE FROM THE STRUCTURAL DRAWINGS, IT SHALL BE
APPROVED AND DESIGNED BY THE ENGINEER OF RECORD PRIOR TO SUBMITTING SHOP DRAWINGS.
VARIATION SHALL BE INDICATED ON THE SHOP DRAWINGS. THE CONTRACTOR SHALL COMPENSATE
CARR ENGINEERING, LLC FOR CHANGES.
2) CONSTRUCTION DOCUMENTS SHALL NOT BE REPRODUCED FOR USE IN SUBMITTALS.
B.
SUBSTITUTIONS: ENGINEER'S APPROVAL SHALL BE SECURED FOR ALL SUBSTITUTIONS.
C.
NON-CONFORMANCE: NOTIFY ENGINEER OF CONDITIONS NOT CONSTRUCTED PER CONTRACT
DOCUMENTS PRIOR TO PROCEEDING WITH CORRECTIVE WORK. SUBMIT PROPOSED REPAIR TO THE
ENGINEER FOR ACCEPTANCE. CONTRACTOR SHALL COMPENSATE CARR ENGINEERING, LLC FOR
DESIGN OF THE REPAIR.
7. OSHA STANDARDS:
A.
THE STRUCTURE IS DESIGNED TO FUNCTION AS A UNIT UPON COMPLETION. NOTHING SHOWN ON THE
STRUCTURAL DRAWINGS SHALL BE CONSTRUED AS ELIMINATING THE NEED FOR THE CONTRACTOR TO
COMPLY WITH ALL OSHA REQUIREMENTS. THE CONTRACTOR SHALL ADD ALL NECESSARY BOLTS, ANCHOR
BOLTS, STIFFENER PLATES, STABILIZER PLATES, BRIDGING, BRACING, BEARING SEATS, COLUMN SPLICES
ETC., AS WELL AS CLOSURES FOR OPENINGS.
B.
WASHERS OR RINGS SHALL BE WELDED TO STEEL COLUMNS TO PROVIDE FOR SAFETY CABLES, DO NOT
PLACE HOLES IN COLUMNS WITHOUT APPROVAL OF THE STRUCTURAL ENGINEER.
C.
WHERE THE STRUCTURAL DRAWINGS APPEAR TO CONFLICT WITH OSHA REQUIREMENTS, THE STRUCTURAL
DRAWINGS REPRESENT FINAL CONDITIONS ONLY; THE CONTRACTOR SHALL ADD ALL ERECTION FRAMING
THAT MAY BE NECESSARY TO COMPLY WITH OSHA.
8. CONSTRUCTION ENGINEERING:
THE STRUCTURE DEFINED IN THE CONTRACT DOCUMENTS HAS BEEN DESIGNED ONLY FOR LOADS ANTICIPATED
ON THE STRUCTURE DURING ITS SERVICE LIFE. PROVIDE ALL REQUIRED ENGINEERING AND OTHER MEASURES TO
ACHIEVE THE MEANS, METHODS AND SEQUENCES OF WORK. SUCH ENGINEERING MAY INCLUDE, BUT IS NOT LIMITED
TO:
- LAYOUT.
- DESIGN OF FORMWORK, SHORING AND RESHORING.
- DESIGN OF CONCRETE MIXES.
- ERECTION PROCEDURES WHICH ADDRESS STABILITY OF THE FRAME DURING CONSTRUCTION OF STEEL.
- WELD PROCEDURES.
- DESIGN OF TEMPORARY BRACING OF WALLS FOR WIND, SEISMIC, OR SOIL LOADS.
- SURVEYING TO VERIFY CONSTRUCTION TOLERANCES.
- EVALUATION OF TEMPORARY LOADS ON STRUCTURE DUE TO EQUIPMENT AND MATERIALS DURING CONSTRUCTION.
- STRUCTURAL ENGINEERING TO RESIST ANY OTHER LOADS NOT IDENTIFIED ON DESIGN DRAWINGS.
9. COORDINATION:
A.
STRUCTURAL DRAWINGS RE NOT STAND-ALONE DOCUMENTS AND ARE INTENDED TO BE USED IN
CONJUNCTION WITH CIVIL, ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND DRAWINGS FROM OTHER
DISCIPLINES. THE CONTRACTOR SHALL COORDINATE ALL REQUIREMENTS OF THE CONTRACT DOCUMENTS
INTO SHOP DRAWINGS AND WORK.
B.
COORDINATE DIMENSIONS OF ALL OPENINGS, BLOCKOUTS, DEPRESSIONS, ETC. WITH DRAWINGS FROM OTHER
DISCIPLINES, PROJECT SHOP DRAWINGS, AND FIELD CONDITIONS PRIOR TO SHOP DRAWINGS SUBMITTAL.
10. SPECIAL INSPECTION:
A.
SPECIAL INSPECTION SHALL BE PROVIDED PER IBC 2012 CHAPTER 17. THE LIST BELOW IS A SUMMARY OF ITEMS
REQUIRING INSPECTION BY THE IBC:
SEE TABLE ON SHEET S101
EARTHWORK NOTES:
1. REFER TO ARCHITECTURAL DRAWINGS FOR BUILDING LOCATION ON THE SITE, FLOOR ELEVATION AND OTHER PERTINENT
SITE AND BUILDING INFORMATION.
2. ELEVATIONS GIVEN THUS ARE TO THE TOP OF FOOTINGS, SLABS, BEAMS, JOISTS, ETC. WITH REFERENCE TO THE
FINISHED FLOOR ELEVATION = (0'-0").
3. A GEOTECHNICAL REPORT IS NOT AVAILABLE FOR THIS SITE. ADDITIONAL TEST BORINGS AND OTHER EXPLORATORY
OPERATIONS MAY BE MADE BY THE CONTRACTOR WITH APPROVAL FROM THE OWNER. DESIGN VALUES FROM THE 2012 IBC
ARE AS FOLLOWS:
A.
ALLOWABLE SOIL BEARING FOR FOOTING .................................................................................................................. 2500 PSF
B.
MINIMUM SOIL SUBGRADE MODULUS REQUIRED ....................................................................................................... 125 PCI
4. THE TOP 9" (MIN.) OF THE EXISTING GRADE IS TO BE SCARIFIED AND RECOMPACTED TO MEET OR EXCEED THE REQUIREMENT
GIVEN IN THE GEOTECHNICAL REPORT.
5. UNLESS NOTED OTHERWISE, NEW FOOTINGS SHALL CENTER UNDER THE WALLS, PIERS OR COLUMNS.
6. WATER SHALL NOT BE ALLOWED TO ACCUMULATE IN THE EXCAVATION. PROVIDE PUMPS, IF NECESSARY, AND OPERATE
NIGHT AND DAY, WHENEVER REQUIRED.
7. THE BASE OF ALL FOOTING EXCAVATIONS SHALL BE OBSERVED BY THE GEOTECHNICAL ENGINEER PRIOR TO PLACEMENT
OF CONCRETE.
8. BACKFILL PLACED WITHIN THE BUILDING AREA SHALL BE WITH SOIL THAT IS APPROVED BY THE GEOTECHNICAL ENGINEER.
PLACE IN LIFTS AND COMPACT IN STRICT COMPLIANCE WITH RECOMMENDATIONS OF THE GEOTECHNICAL ENGINEER.
PLACE IN LOOSE LIFTS OF 8 INCHES OR LESS AND COMPACT. FILL SHOULD BE FREE OF FAT CLAYS AND ORGANIC SOIL
(UNIFIED SOIL CLASSIFICATIONS CH, OL, OH, MH OR PT), FROZEN MATERIAL, RUBBLE, DEGRADABLE MATERIAL, CHEMICAL
CONTAMINANTS AND STONES THAT INTERFERE WITH COMPACTION OR COMPACTION TESTING. IN GENERAL, AT LEAST 70%
OF THE FILL SHOULD PASS A 3/4-INCH SIEVE, THE OVER-SIZE LIMIT FOR THE ASTM D698 MAXIMUM DENSITY TEST.
9. FILL SHOULD BE PLACES ON STABLE, UNFROZEN SURFACES AND IN NEARLY HORIZONTAL LIFTS THAT HAVE THICKNESSES
THAT ARE COMPATIBLE WITH THE COMPACTION EQUIPMENT USED, BUT GENERALLY NOT OVER EIGHT INCHES. ALL FILL
OTHER THAN COARSE AGGREGATES SHOULD BE COMPACTED TO AT LEAST 95% OF ITS MAXIMUM DRY DENSITY
DETERMINED BY ASTM D698, TEST METHOD FOR LABORATORY COMPACTION CHARACTERISTICS OF SOIL USING STANDARD
EFFORT (12,400 FT-LB/CUBIC FOOT). COMPACTION USUALLY REQUIRES ADJUSTMENTS OF FILL MOISTURE CONTENTS TO
WITHIN THREE PERCENTAGE POINTS OF THE ASTM D698 OPTIMUM MOISTURE. COARSE AGGREGATES SHOULD BE
VIBRATORY-COMPACTED TO INTERLOCK THE PARTICLES TO 98% STANDARD PROCTOR PER ASTM D698.
CONCRETE NOTES:
1. CONCRETE WORK SHALL CONFORM TO ALL REQUIREMENTS OF ACI 301-99, SPECIFICATIONS FOR STRUCTURAL
CONCRETE FOR BUILDINGS, EXCEPT AS MODIFIED BY SUPPLEMENTAL REQUIREMENTS CONTAINED IN THE FOLLOWING
NOTES.
2. UNLESS OTHERWISE DETAILED OR NOTED, REINFORCING SHALL BE IN ACCORDANCE WITH "THE ACI DETAILING MANUAL,
SP-66."
3. SUBMIT SHOP DRAWINGS FOR FABRICATION AND PLACEMENT OF CONCRETE REINFORCING. SHOW PLAN VIEW OF SLAB, INCLUDE
SCHEDULES AND DIAGRAMS OF BENT BARS AND SHOW ARRANGEMENT OF CONCRETE REINFORCING. ENGINEER'S REVIEW OF
SHOP DRAWINGS WILL BE FOR COMPLIANCE WITH DESIGN REQUIREMENTS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR
VERIFYING DIMENSIONS AND QUANTITIES RELATIVE TO REINFORCING STEEL.
4. ALL CONCRETE TESTING SHALL BE PERFORMED UNDER THE DIRECT SUPERVISION OF A QUALIFIED ENGINEER WHO IS
LICENSED TO PRACTICE IN THE STATE OF ILLINOIS. THE TESTING AGENCY SHALL MEET REQUIREMENTS CONTAINED IN ASTM
E329. SEE SPECIFICATIONS FOR TESTING REQUIREMENTS.
5. PREPARE DESIGN MIXES FOR EACH TYPE AND STRENGTH OF CONCRETE BY EITHER LABORATORY TRIAL BATCH OR FIELD
EXPERIENCE METHODS AS SPECIFIED IN ACI 301.
A.
TRIAL BATCH METHOD: IF TRIAL BATCHES ARE USED, AND INDEPENDENT TESTING LABORATORY, APPROVED BY
THE ARCHITECT, SHALL PREPARE MIX DESIGNS. THE MIX DESIGN SHALL BE PROPORTIONED TO ACHIEVE AN
AVERAGE STRENGTH OF 1200 PSI HIGHER THAN THE SPECIFIED STRENGTH (F'C).
B.
FIELD EXPERIENCE METHOD: IF THE FIELD EXPERIENCE METHOD IS SELECTED, THE PROPOSED MIX DESIGN
MUST BE ACCOMPANIED BY THE COMPLETE STANDARD DEVIATION ANALYSIS.
C.
SLUMP SHALL BE 4" MAXIMUM, 2" MINIMUM FOR STRUCTURAL SLABS.
6. READY-MIX CONCRETE SHALL BE IN COMPLIANCE WITH REQUIREMENTS OF ASTM C94, AND AS HEREIN SPECIFIED.
7. COMPRESSIVE STRENGTH: STRENGTH REQUIREMENTS AT 28 DAYS AND THE LOCATION OF EACH TYPE OF CONCRETE
REQUIRED FOR THIS PROJECT SHALL BE AS FALLOWS:
TYPE
1
INTENDED
USE
SLAB-ON
-GRADE
28 DAY MAX
STRENGTH
MAX WATER/CEMENT
RATIO INCLUDING
FLY ASH
MIN CEMENT
MATERIAL
INCLUDING
FLY ASH
MAX AGGREGATE
SIZE
CEMENT TYPE
SLUMP LIMITS
( +1", -2" )
4 KSI
0.50
520 LB/CU. YD
3/4 IN
I OR II
4
FOOTINGS
2 GRADE BEAMS
AND WALLS
4 KSI
0.50
520 LB/CU. YD
1 IN
I OR II
4
METAL BUILDING CRITERIA:
1.
FOUNDATION DESIGN IS BASED ON PRELIMINARY DESIGN DRAWINGS RECEIVED FROM BUTLER MANUFACTURING. FINAL
DESIGN REACTIONS SUPPLIED BY THE SELECTED METAL BUILDING MANUFACTURER MAY DIFFER FROM PRELIMINARY
ESTIMATED REACTIONS. BASED ON FINAL REACTIONS SUPPLIED, MODIFICATIONS TO THE FOUNDATION PLAN MAY BE
REQUIRED. GENERAL CONTRACTOR SHALL INCLUDE IN THEIR BID AN ADD AND DEDUCT PRICE PER CUBIC YARD OF
CONCRETE WORK INSTALLED IN CASE SUCH CHANGES ARE REQUIRED.
2.
METAL BUILDING MANUFACTURER SHALL ENGAGE A PROFESSIONAL ENGINEER LICENSED TO PRACTICE STRUCTURAL
ENGINEERING IN THE STATE OF ILLINOIS TO DESIGN THE METAL BUILDING AND TO SUBMIT STAMPED AND SEALED
DRAWINGS AND STRUCTURAL CALCULATIONS FOR THE METAL BUILDING.
3.
FOUNDATION DESIGN IS BASED ON THE METAL BUILDING COLUMNS HAVING PINNED BASES AND TRANSFERRING NO
MOMENTS TO THE FOUNDATIONS.
4.
ALL EXTERNAL LATERAL LOAD RESISTANCE AND STABILITY OF THE METAL BUILDING IN THE COMPLETED STRUCTURE IS
PROVIDED BY MOMENT FRAMES AND TENSION ONLY ROD BRACING. THE VERTICAL LATERAL MEMBERS CARRY THE
APPLIED LATERAL LOADS TO THE BUILDING FOUNDATION. THE TENSION ONLY ROD BRACING AT THE ROOF SERVES AS THE
HORIZONTAL DIAPHRAGM THAT DISTRIBUTES THE LATERAL WIND AND SEISMIC FORCES HORIZONTALLY TO THE VERTICAL
LATERAL MEMBERS. ALL LATERAL RESISTING MEMBERS ARE BY THE METAL BUILDING MANUFACTURER.
5.
METAL BUILDING MANUFACTURER IS SOLELY RESPONSIBLE FOR THE DESIGN AND MANUFACTURER OF THE METAL
BUILDING. THE BUILDING MUST BE DESIGNED TO MEET THE LOADING INDICATED IN THE DRAWINGS AND THE DESIGN
CRITERIA INDICATED ABOVE.
6.
METAL BUILDING MANUFACTURER IS TO COORDINATE WITH ARCHITECTURAL DRAWINGS FOR WINDOW AND DOOR
OPENINGS WHEN DESIGNING THE LATERAL SYSTEM.
7.
SEE METAL BUILDING DRAWINGS FOR ANCHOR ROD MATERIAL GRADE, ANCHOR ROD DIAMETERS, QUANTITIES AND
LAYOUT.
REINFORCEMENT STEEL:
1.
FOR CAST-IN-PLACE CONCRETE THE FOLLOWING MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR
REINFORCEMENT UNLESS NOTED OTHERWISE:
CONCRETE CAST AGAINST AND
PERMANENTLY EXPOSED TO EARTH
3 INCHES
CONCRETE EXPOSED TO EARTH OR WEATHER
NO. 6 BARS OR LARGER
NO. 5 BARS OR SMALLER
2 INCHES
1 1/2 INCHES
SLABS, WALLS, JOISTS NOT EXPOSED
TO WEATHER OR IN CONTACT WITH EARTH
NO. 14 AND NO. 18 BARS
NO. 11 BARS OR SMALLER
1 1/2 INCHES
3/4 INCHES
BEAMS AND COLUMNS NOT EXPOSED TO
WEATHER OR IN CONTACT WITH EARTH
1 1/2 INCHES
2.
DIMENSIONS OF CONCRETE COVER FOR REINFORCEMENT INDICATED ON DRAWINGS ARE TO OUTERMOST
REINFORCING BARS. FOR BEAMS OR COLUMNS WITH STIRRUPS OR TIES, CLEAR COVER INDICATED IS TO STIRRUPS OR
TIES.
3.
BAR SPLICES: SPLICE REINFORCING WHERE INDICATED ON THE DRAWINGS. ALL SPLICES SHALL BE CLASS 'B' AS
DEFINED IN ACI 318. IF SPLICE LENGTH IS NOT GIVEN ON THE DRAWINGS, PROVIDE LAP LENGTHS (IN INCHES) AS
FOLLOWS:
3000 PSI CONC
BAR SIZE
#3
#4
#5
#6
#7
#8
#9
#10
#11
OTHER
22
29
36
43
63
72
81
91
101
TOP
28
38
47
56
81
93
105
118
131
4000 PSI CONC
OTHER
19
25
31
37
54
62
70
79
87
TOP
25
33
41
49
71
81
91
102
114
LAP LENGTHS ASSUME CLEAR SPACING BETWEEN BARS OF 2 BAR DIAMETERS, AND A MINIMUM
COVER OF 1 BAR DIAMETER. FOR DEVELOPMENT LENGTHS, DIVIDE BY 1.3. TOP BARS ARE DEFINED AS
HORIZONTAL BARS WITH MORE THAN 1'-0" OF FRESH CONCRETE BELOW.
4.
SUBMIT SHOP DRAWINGS SHOWING REINFORCING STEEL QUANTITIES AND PLACEMENT. REINFORCING STEEL
DESIGNATIONS ON SHOP DRAWINGS SHALL BE INCH-POUND SIZES.
5.
ALL REINFORCING STEEL SHALL BE DETAILED AND PLACED IN CONFORMANCE WITH THE AMERICAN CONCRETE
INSTITUTE "DETAILS AND DETAILING OF REINFORCED CONCRETE" (ACI 315) EXCEPT AS OTHERWISE SHOWN, NOTED OR
SPECIFIED.
6.
PROVIDE ADEQUATE TIES FOR ALL REINFORCING BARS AND STIRRUPS IN CONCRETE SLABS AND BEAMS. REINFORCING
BARS TO BE HELD AT CORRECT DISTANCE FROM FORMS BY ADEQUATE CONCRETE BLOCKS, STEEL CHAIRS OR TIES. ALL
REINFORCING BARS, ANCHOR BOLTS AND OTHER CONCRETE INSERTS SHALL BE SECURED IN POSITION WITH TIES OR
WELDS PRIOR TO PLACING CONCRETE.
7.
UNLESS NOTED OTHERWISE, SUPPORTS FOR REINFORCEMENT SHALL HAVE CLASS 2 PROTECTION AS DEFINED IN THE
CRSI MANUAL OF STANDARD PRACTICE.
8.
SUPPORTS FOR COATED REINFORCEMENT SHALL HAVE CLASS 1 PROTECTION AS DEFINED IN THE CRSI MANUAL OF
STANDARD PRACTICE.
9.
CONTINUOUS REINFORCING SHALL BE LAPPED AS FOLLOWS UNLESS NOTED OTHERWISE:
TOP BARS
MIDSPAN
BOTTOM BARS
DIRECTLY OVER SUPPORT
10. DOWELS BETWEEN FOOTINGS AND WALLS OR COLUMNS SHALL BE THE SAME GRADE, SIZE AND SPACING OR NUMBER AS
THE VERTICAL REINFORCING, RESPECTIVELY, UNLESS NOTED OTHERWISE.
11. REINFORCING BARS SHALL BE BENT COLD, AND NO METHOD OF FABRICATION SHALL BE USED WHICH WOULD BE
INJURIOUS TO THE MATERIAL. HEATING OF BARS FOR BENDING IS NOT PERMITTED.
2/3 D
W
STRUCTURAL
FILL
2/3 D
DESIGN FTG LEVEL
RECOMMENDED
EXCAVATION LEVEL
1
TYP FOOTING OVER EXCAVATION
3/4" = 1'-0"
TATE OF I LL INOI
CHAD M.
CARR
081-006490
ST RUCT URA L E
I hereby certify that this engineering document was prepared by
me or under my direct personal supervision and that I am a duly
licensed Structural Engineer under the laws of the State of
Illinois.
11-04-2025
Signature
Date
Chad M. Carr
License No. 081-006490
My license renewal date is November 30, 2026
Pages or sheets covered by this seal: S100 - S301
Carr Engineering LLC
Illinois Design Firm License: #184.007877-0003
CARR ENGINEERING, LLC
ILLINOIS DESIGN FIRM LIC No.
184.007877-0003
3294 Fields Dr.
Bettendorf, IA 52722
(563) 503-6100
NO.
DESCRIPTION
DATE
1
PERMIT SET
11.04.25
Project number
Date
Drawn by
Checked by
25-134
11/04/2025
WDH
CMC
GENERAL NOTES
S100
STRUCTURAL COMPONENT TESTING AND INSPECTION
1. THE FOLLOWING TESTING AND INSPECTION OF STRUCTURAL COMPONENTS IS REQUIRED AS DETAILED IN CHAPTER 17 OF THE 2012 INTERNATIONAL BUILDING CODE (IBC).
2. SEE MECHANICAL, PLUMBING AND ELECTRICAL SPECIFICATIONS FOR TESTING AND INSPECTION REQUIREMENTS OF NON-STRUCTURAL COMPONENTS.
3. WORK PERFORMED ON THE PREMISES OF A FABRICATOR APPROVED BY THE BUILDING OFFICIAL PER SECTION 1704.2.5.1 OF CHAPTER 17 OF THE 2012 INTERNATIONAL BUILDING
CODE NEED NOT BE TESTED AND INSPECTED PER THE TABLE BELOW. THE FABRICATOR SHALL SUBMIT A CERTIFICATE OF COMPLIANCE THAT THE WORK HAS BEEN PERFORMED IN
ACCORDANCE WITH THE APPROVED PLANS AND SPECIFICATIONS TO THE BUILDING OFFICIAL AND THE ARCHITECT AND ENGINEER OF RECORD.
4. DUTIES OF THE SPECIAL INSPECTION AGENCY (IBC CHAPTER 17):
A. PERFORM ALL TESTING AND INSPECTION REQUIRED PER APPROVED TESTING AND INSPECTION PROGRAM.
B. FURNISH INSPECTION REPORTS TO THE BUILDING OFFICIAL AND THE OWNER.
C. SUBMIT A FINAL SIGNED REPORT STATING WHETHER THE WORK REQUIRING SPECIAL INSPECTION WAS, TO THE BEST OF THE SPECIAL INSPECTION AGENCY'S KNOWLEDGE,
IN CONFORMANCE WITH THE APPROVED PLANS AND SPECIFICATIONS.
FOUNDATION PREPARATION
VERIFY MATERIALS BELOW SHALLOW FOOTINGS ARE ADEQUATE TO ACHIEVE THE DESIGN BEARING CAPACITY.
VERIFY EXCAVATIONS ARE EXTENDED TO PROPER DEPTH AND HAVE REACHED PROPER MATERIAL.
PERFORM CLASSIFICATION AND TESTING OF COMPACTED FILL MATERIALS.
VERIFY USE OF PROPER MATERIALS, DENSITIES, AND LIFT THICKNESSES DURING PLACEMENT AND COMPACTION OF COMPACTED FILL.
PRIOR TO PLACEMENT OF COMPACTED FILL, OBSERVE SUBGRADE AND VERIFY THAT THE SITE HAVE BEEN PROPERLY PREPARED.
X
X
X
X
X
REFERENCE
D STANDARD
IBC
REFERENCE
1705.6
1705.6
1705.6
1705.6
1705.6
CONCRETE AND CONCRETE PLACEMENT
INSPECT FORMWORK FOR SHAPE, LOCATION AND DIMENSIONS OF THE CONCRETE MEMBER BEING FORMED.
INSPECTION OF REINFORCING STEEL, INCLUDING PRESTRESSING TENDONS, AND PLACEMENT.
INSPECTION OF ANCHORS POST-INSTALLED INSTALLED IN HARDENED CONCRETE MEMBERS.
A. ADHESIVE ANCHORS INSTALLED IN HORIZONTALLY OR UPWARD INCLINED ORIENTATIONS TO RESIST SUSTAINED LOADS.
VERIFYING USE OF REQUIRED DESIGN MIX.
PRIOR TO CONCRETE PLACEMENT, FABRICATE SPECIMENS FOR STRENGTH TESTS, PERFORM SLUMP AND AIR CONTENT TESTS, AND
DETERMINE THE TEMPERATURE OF THE CONCRETE.
INSPECTION OF CONCRETE PLACEMENT FOR PROPER APPLICATION TECHNIQUES.
FF AND FL SLAB ON GRADE FLATNESS TESTING
X ACI 318: 26.11.1.2(b)
X ACI 318: CHG. 20, 25.2, 25.3,
26.6.1-26.6.3
1908.4
X
ACI 318: 17.8.2.4(b)
X
ACI 318: CH. 19, 26.4.3, 26.4.4
1904.1, 1904.2
1908.2, 1908.3
X
ACI 318: 26.4, 26.12
X
ACI 318: 26.5
ASTM E1155
1908.10
1908.6, 1908.7,
1908.8
STRUCTURAL STEEL
1. MATERIAL VERIFICATION OF HIGH-STRENGTH BOLTS, NUTS, AND WASHERS:
A. IDENTIFICATION MARKINGS TO CONFORM TO ASTM STANDARDS SPECIFIED IN THE APPROVED CONSTRUCTION DOCUMENTS.
B. MANUFACTURER’S CERTIFICATE OF COMPLIANCE REQUIRED.
2. INSPECTION OF HIGH-STRENGTH BOLTING:
A. SNUG TIGHT JOINTS.
STEEL DECK
1. MATERIAL VERIFICATION OF STRUCTURAL STEEL
A. IDENTIFICATION MARKINGS TO CONFORM TO ASTM STANDARDS SPECIFIED IN THE APPROVED CONSTRUCTION DOCUMENTS.
B. MANUFACTURER’S CERTIFIED TEST REPORTS.
2. INSPECTION OF WELDING:
A. FLOOR AND ROOF DECK WELDS.
REFERENCE
D STANDARD
IBC
REFERENCE
X APPLICABLE ASTM MATERIAL
STANDARDS: AISC 360,
X SECTION A3.3
AISC 360, SECTION M2.5
X
REFERENCE
D STANDARD
X APPLICABLE ASTM
X MATERIAL STANDARDS
X AW D1.3
IBC
REFERENCE
1 ISOMETRIC VIEW
ALL STEEL FRAMING IS TO BE DESIGNED BY THE METAL BUILDING MANUFACTURER
APPROX
ARCH
BP
BLDG
B.D.
BRG
C/C
CFMS
CLR
CMU
CONC
CONT
D
DAS
DEG
DEMO
DIM
DL
DWG
EA
EF
EMBED
EOD
EOS
EQ
EXIST
(E)
EXP
EXT
f'c
FND
FIN
FLR
FR
FT
FTG
GA
GALV
GC
GYP
HORIZ
HDAB
HDAS
I.F.
IN.
JST
LL
LLH
LLV
MAX
MIN
MISC
(N)
NIC
NTS
OC
O.F.
OPNG
OPP
PC
PL
PSF
PSI
R
REINF
REQ'D
SIM
SP
SPEC
SPEC'D
STD
STIFF
T.O.
TYP
U.N.O.
VERT
WWF
@
Ø OR DIA
# OR NO.
ABBREVIATIONS
APPROXIMATE, APPROXIMATLY
ARCHITECT, -URAL, -URE
BASE PLATE
BUILDING
BOTTOM OF
BEARING
CENTER TO CENTER
COLD FORMED METAL STEEL
CLEAR, -(ANCE)
CONCRETE MASONRY UNIT
CONCRETE
CONTINUOUS
DEPTH
DEFORMED ANCHOR STUD
DEGREE
DEMOLITION
DIMENSION
DEAD LOAD
DRAWING
EACH
EACH FACE
EMBEDDED
EDGE OF DECK
EDGE OF SLAB
EQUAL
EXISTING
EXISTING STRUCTURAL MEMBER
EXPANSION
EXTERIOR
CONCRETE COMPRESSIVE MEMBER
FOUNDATION
FINISH
FLOOR
FRAMING
FOOT
FOOTING
GAUGE
GALVANIZED
GENERAL CONTRACTOR
GYPSUM BOARD
HORIZONTAL
HEAD ANCHOR BOLT
HEAD ANCHOR STUD
INSIDE FACE
INCH
JOIST
LIVE LOAD
LONG LEG HORIZONTAL
LONG LEG VERTICAL
MAXIMUM
MINIMUM
MISCELLANEOUS
NEW STRUCTURAL MEMBER
NOT IN CONTRACT
NOT TO SCALE
ON CENTER
OUTSIDE FACE
OPENING
OPPOSITE
PRECAST
PLATE
POUNDS PER SQUARE FOOT
POUNDS PER SQUARE INCH
RADIUS
REINFORCING, -ED, -MENT
REQUIRED
SIMILAR
SPACE(S)
SPECIFICATION(S)
SPECIFIED
STANDARD
STIFFENER
TOP OF
TYPICAL
UNLESS NOTED OTHERWISE
VERTICAL
WELDED WIRE FABRIC
AT
DIAMETER
NUMBER
DESCRIPTION
STEP UP =
SLOPE UP =
SYMBOLS LEGEND
SYMBOL
DESCRIPTION
ELEVATION =
REVISION CLOUD =
SYMBOL
T/X
EL (XXX'-X")
MOMENT
CONNECTION =
DETAIL
SECTION CUT =
DTL#
SHT#
BUILDING
SECTION CUT =
CONCRETE
IN SECTION =
MASONRY =
FOOTING SIZE =
F-X
COLUMN =
C-X
NORTH ARROW =
GRADE =
STRUCTURAL FILL =
NORT H
SUBGRADE =
BRACE =
WELDED WIRE FABRIC =
FOOTING STEP =
(-X'-X")
(-X'-X")
CARR ENGINEERING, LLC
ILLINOIS DESIGN FIRM LIC No.
184.007877-0003
3294 Fields Dr.
Bettendorf, IA 52722
(563) 503-6100
NO.
DESCRIPTION
DATE
1
PERMIT SET
11.04.25
Project number
Date
Drawn by
Checked by
NOTES &
SYMBOLS
25-134
11/04/2025
WDH
CMC
S101
12
4
1' - 6"
10' - 9 3/4"
23' - 6"
3' - 4 1/2"
10' - 9 3/4"
5'-0"X5'-0"
STOOP
4
S300
25' - 0"
5
100' - 0"
25' - 0"
TYP. 2
S300
1
S300
6
7
10' - 9 3/4"
25' - 0"
3' - 4 1/2"
10' - 9 3/4"
5'-0"X5'-0"
STOOP
4
S300
1' - 0"
8"
P-2
F-1
B
P-4
8' - 4"
3"
HP
4 1/2" 8" 6' - 3" 8" 4 1/2"
FIRST
RAIL
LINE
1' - 8"
1' - 3"
1' - 3"
1' - 3"
1' - 3"
SLOPE DN
X-BRACE BY PEMB MNFR.
P-1
F-1
HP
~
~
~
SLOPE DN
P-1
P-1
F-1
F-1
PROVIDE CONTROL JOINTS
AT 12'-6" MAX
SPACING EACH WAY -
TYPICAL
~
(TOP OF TRENCH DRAIN EL = -0'-3")
7
S301
P-2
F-2
HP
P-3
F-2
3
S300
SLOPE DN
P-3
F-2
SLOPE DN
DARK HATCH
INDICATES 8 IN
DEEP X 6'-3" WIDE
RECESS FOR
TRACKS AND GROUT
BY OTHERS
SLOPE DN
(TOP OF CONCR EL = -0'-0")
SLOPE DN
(TOP OF TRENCH DRAIN EL = -0'-3")
7
S301
8
S301
P-4
F-2
Q
5
S300
TYP.
8"
2' - 0"
1
S300
~
HP
P-2
P-1
F-1
F-1
~
~
~
SLOPE DN
HP
P-1
F-1
45.00°
TYP.
X-BRACE BY PEMB MNFR.
2
S300
TYP.
1
S300
NORT H
MAIN FLOOR FOUNDATION PLAN
1/8" = 1'-0"
P-3
F-2
1
S300
SLOPE DN
P-3
F-2
TYP.
5
S300
8"
2' - 0"
P-3
F-2
HP
P-1
P-2
F-1
F-2
1' - 0"
NOTES:
3.
1.
SLAB-ON-GRADE:
A.
GRIDLINES ARE LOCATED AT OUTSIDE FACE OF FOUNDATION WALL
OR COLUMN CENTERS UNLESS NOTED OTHERWISE.
4.
B.
SLAB-ON-GRADE TO BE 8 INCH THICK NORMAL WEIGHT
CONCRETE ON 14 INCH (MIN.) OF EXISTING ENGINEERED GRANULAR
BASE. (CRUSHED AGGREGATE) RE: 5/S301.
C.
REINFORCE 8 INCH SLAB-ON-GRADE WITH FORTA FERRO FIBER
ADMIXTURE (DOSAGE RATE 5.0 LB/CY). (ALTERNATE SLAB
REINFORCING #4 @ 18" O.C. CENTERED.
5.
D.
TOP OF SLAB-ON-GRADE IS AT ELEVATION = (0'-0") UNLESS
NOTED OTHERWISE.
E.
PLACE CONTROL OR CONSTRUCTION JOINTS AT 12'-6" ON CENTER
A
MAXIMUM. USE DOWEL BASKETS AT ALL CONTROL JOINTS.
SEE 6/S301.
F.
REFERENCE ARCHITECTURAL DRAWINGS FOR SLAB SLOPES AND
DEPRESSIONS NOT SHOWN ON STRUCTURAL DRAWINGS.
2.
E
FOOTINGS:
A.
FOOTINGS ARE SHOWN ON PLAN THUS: F-X. REFERENCE DETAILS
AND FOOTING SCHEDULE FOR SIZES AND REINFORCING.
B.
ALL COLUMN FOOTINGS SHALL BE CENTERED ON PIERS UNLESS
OTHERWISE DIMENSIONED.
C.
TOP OF EXTERIOR FOOTING IS AT ELEVATION (-3'-0") UNLESS
NOTED OTHERWISE.
D.
SEE FOOTING OVER-EXCAVATION DETAIL THIS SHEET WHERE
REQUIRED.
PIERS:
A.
PIER TYPE NOTED ON PLAN THUS: P-X. SEE SHEET S300 FOR DETAILS.
B.
TOP OF PIER ELEVATION TO BE (0'-0") UNLESS NOTED OTHERWISE.
FOUNDATIONS:
A.
CONSULT WITH OWNER'S GEOTECHNICAL ENGINEER AND SEE PROJECT'S
REPORT OF SUBSURFACE EXPLORATION AND GEOTECHNICAL
ENGINEERING REQUIREMENTS, SPECIFIC FOUNDATION SUBGRADE
PREPARTION REQUIREMENTS, UNDER-SLAB DRAINAGE, SITE DEWATERING
AND OTHER EARTH WORK REQUIREMENTS.
COLUMNS:
A.
ALL COLUMNS, BASEPLATES AND ANCHOR BOLT SIZES AND LOCATIONS BY
METAL BUILDING SUPPLIER.
B.
SEE 'METAL BUILDING CRITERIA' ON SHEET S100.
MARK
F-1
F-2
FOOTING SCHEDULE
SIZE
(WxLxD)
TOP
REINFORCING
9'-0"x9'-0"x1'-6" (9) #7 BARS EA WAY
5'-0"x5'-0"x1'-0" (6) #5 BARS EA WAY
BOT
REINFORCING
(9) #7 BARS EA WAY
(6) #5 BARS EA WAY
FOUNDATION WALL SCHEDULE
WALL
THICKNESS
REINFORCING
COMMENTS
8 IN.
#4 @ 12" O.C. EA WAY
CENTERED
12 IN.
#4 @ 12" O.C. EA WAY
EA FACE
KEYNOTES:
WALL RECESSED 8" FOR SLAB POUR OVER.
HP HAIRPIN - SEE DETAILS 2/S300 & 1/S301.
G
THESE PLANS REQUIRE FINISHED GRADE AT THE BUILDING PERIMETER
TO BE WITHIN 6 INCHES OF TOP OF INTERIOR BUILDING SLAB ELEVATION.
NOTIFIY THE EOR IF FINAL GRADES DO NOT MEET THIS REQUIREMENT.
SEE SITE EXHIBIT DRAWING BY CMT ENGINEERS AND CONSULTANTS
DATED AUGUST 13, 2025 FOR EXACT BUILDING LOCATION.
CARR ENGINEERING, LLC
ILLINOIS DESIGN FIRM LIC No.
184.007877-0003
3294 Fields Dr.
Bettendorf, IA 52722
(563) 503-6100
NO.
DESCRIPTION
DATE
1
PERMIT SET
11.04.25
2
REV FOR DOOR
03.09.26
K
M
NEW BUILDING LOCATION
P
T
Project number
Date
Drawn by
Checked by
25-134
11/04/2025
WDH
CMC
FOUNDATION
PLAN
NORT H
BUILDING LOCATION AERIAL
NO SCALE
S200
-
8"
(RE: PEMB)
PER FDN WALL
SCHED
GRADE WALL
RE: SCHED
FOR REINF.
(3)#5
HORZ
BOTTOM
1/2" EXP. JOINT
SLAB-ON-GRADE
RE: PLAN
FIN FLOOR
EL (0'-0")
2" RIGID INSUL.
EXT. 2 FT UNDER SLAB
T.O. FTG.
EL (-3'-0")
RE: PLAN
1
TYPICAL FOUNDATION WALL
3/4" = 1'-0"
RE: PEMB
SUPPLIER
FOR ANCHOR
RODS - 1'-6"
MIN EMBED
-
8"
PER FDN WALL
SCHED
GRADE WALL
RE: SCHED
FOR REINF.
RE: PLAN
RE: FTG SCHED
COL & BASE
PL BY MTL
BLDG MANUF
1/2" EXP. JOINT
CONC. SLAB
RE: PLAN
FIN FLOOR
EL (0'-0")
#5 HAIRPEN AROUND
COLUMN W/ 5'-0" LEGS -
RE: 1/S301
CONC. PIER
RE: SHEET S300
AND PLAN MARK
SEE COL FTG SCHED
FOR REINF
T.O. FTG.
EL (RE: PLAN)
1/2" EXP. JOINT
7
8"
#5 x CONT.
(TYP.)
PER FDN WALL
SCHED
RE: SCHED FOR
WALL REINF.
(3)#5
HORZ
BOTTOM
RE: PLAN
2'-0"
#5 x
@ 12" O.C. (TYP.)
SLAB-ON-GRADE
(TYP.) - RE: PLAN
FIN FLOOR
EL (0'-0")
T.O. FTG.
EL (RE: PLAN)
2
TYPICAL EXTERIOR COL FOOTING
3/4" = 1'-0"
3
TYPICAL THRESHOLD FOUNDATION WALL
3/4" = 1'-0"
SLOPE AT 1/8" PER
FOOT OR AS
INDICATED ON SITE
PLAN
#4 DOWELS x 1'-6"
@ 12" O.C.,
(TYPICAL)
6" CONCRETE SLAB WITH
#4'S @ 12" O.C., EACH
WAY, CENTERED IN THE
SLAB THICKNESS
A
8"
1/2" EXPANSION JOINT
MATERIAL
SMOOTH TROWEL FINISH
CONCRETE SLAB -
SEE PLAN FOR THICKNESS
AND REINFORCING
FIN FLOOR
EL (0'-0")
4" EXTRUDED POLY-
STYRENE INSULATION
(ASTM C578)
ALL SIDES AND ABOVE
6" FREE DRAINING
MATERIAL
FOUNDATION WALL -
SEE PLAN FOR
DIMENSIONS AND
REINFORCING
#4'S @ 12" O.C.,
EACH WAY
8"
VARIES - SEE PLAN
GOOD FOR 3'-0" TO 8'-0"
NOTES:
1.
SEE ARCHITECTURAL DRAWINGS FOR
EXACT STOOP LAYOUT AND LOCATIONS.
4
TYPICAL STOOP SECTION
3/4" = 1'-0"
1
8 1/2"
RE: PEMB
SUPPLIER FOR
ANCHOR RODS
1-6" MIN EMBED
PER FDN WALL
SCHED
GRADE WALL
RE: SCHED
FOR REINF.
RE: PLAN
RE: PLAN
COL & BASE
PL BY MTL
BLDG MANUF
1/2" EXP. JOINT
CONC. SLAB
RE: PLAN
FIN FLOOR
EL (0'-0")
CONC. PIER
RE: SHEET S300
AND PLAN MARK
SEE COL FTG SCHED
FOR REINF
T.O. FTG.
EL (RE: PLAN)
-
T.O. WALL = 0'-0"
-
T.O. PIER = 0'-0"
SEE METAL BLDG DWG FOR
BASE PL AND A.B. SIZE AND
LOC.
9"
9"
1' - 6"
-
(10) #6 VERT. W/ STD.
HOOK OR LAP WITH
DOWELS
-
-
RE: PLAN
#4 TIES @
12" O.C.
1 1/2" CLR.
(TYP.)
9"
9"
1' - 6"
T.O. WALL = 0'-0"
8"
1' - 8"
2' - 4"
-
RE: PLAN
T.O. PIER = 0'-0"
8"
1' - 8"
2' - 4"
#4 TIES @ 12" O.C.
(12) #6'S,
VERT.
5
TYPICAL EXTERIOR ENDWALL COL FOOTING
3/4" = 1'-0"
6
'P1' PIER DETAIL
3/4" = 1'-0"
7
'P2' PIER DETAIL
3/4" = 1'-0"
CARR ENGINEERING, LLC
ILLINOIS DESIGN FIRM LIC No.
184.007877-0003
3294 Fields Dr.
Bettendorf, IA 52722
(563) 503-6100
NO.
DESCRIPTION
DATE
1
PERMIT SET
11.04.25
2
REV FOR DOOR
03.09.26
T.O. PIER = 0'-0"
-
SEE METAL BLDG DWG FOR
BASE PL AND A.B. SIZE AND
LOC.
7
2' - 4"
1' - 8"
8"
7 1/2"
#4 TIES @
12" O.C.
7
2' - 4"
1' - 8"
8"
(10) #6 VERT. W/ STD.
HOOK OR LAP WITH
DOWELS
T.O. WALL = 0'-0"
9
'P3' PIER DETAIL
3/4" = 1'-0"
1
2' - 4"
8"
1' - 8"
(10) #6 VERT. W/ STD.
HOOK OR LAP WITH
DOWELS
T.O. WALL = 0'-0"
#4 TIES @
12" O.C.
1
2' - 4"
8"
1' - 8"
9 1/2"
1' - 0"
1' - 4"
T.O. WALL = -0'-8"
1' - 0"
1' - 4"
T.O. PIER = 0'-0"
-
SEE METAL BLDG DWG FOR
BASE PL AND A.B. SIZE AND
LOC.
10 'P4' PIER DETAIL
3/4" = 1'-0"
Project number
Date
Drawn by
Checked by
25-134
11/04/2025
WDH
CMC
FOUNDATION
DETAILS
S300
This is the opportunity summary page. It provides an overview of this opportunity and a preview of the attached documentation.
Daily notification on new contract opportunities

With GovernmentContracts, you can:

  • Find more opportunities and win more business
  • Receive daily alerts for all new bid opportunities
  • Get contract opportunities matched to your business
ONE WEEK FREE TRIAL

See also

...cabinet face and push-thru acrylic graphics. Sign shall include a minimum 12-inch high ...

City of Champaign

Bid Due: 6/12/2026

...building foundation and pavement, and construction of a new 1.0 MG elevated storage ...

Plainfield village

Bid Due: 6/16/2026

* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.