Z1DA--36C26125R0019 | 36C261-24-AP-5056 | NRM 640-25-900 | Palo Alto Boiler Plant Retrofit | CH | 640
Looking for contract opportunity help?
General Information
-
Contract Opportunity Type: Solicitation (Original)
-
Original Published Date: Dec 19, 2024 11:03 am PST
-
Original Date Offers Due: Feb 06, 2025 09:00 am PST
-
Inactive Policy: Manual
-
Original Inactive Date:
May 07, 2025
-
Initiative:
Classification
-
Original Set Aside:
-
Product Service Code: Z1DA - MAINTENANCE OF HOSPITALS AND INFIRMARIES
-
NAICS Code:
-
238220 - Plumbing, Heating, and Air-Conditioning Contractors
-
Place of Performance:
Description
RFP 36C26125R0019
36C26125R0019| VA Palo Alto Boiler Plant Retrofit
This is a Request For Proposal. The Government requests that interested parties review the Description of Services and provide the proposal information to the Contract Specialist, Nicole Renfrew, at Nicole.Renfrew@va.gov, by 9:00 AM PST on January 15, 2025.
The contractor must provide all personnel, expertise, equipment, tools, materials, supervision, due diligence and other items and services necessary, as described in the Statement of Work, to retrofit three (3) boilers at the VA Palo Alto Health Care System (VAPAHCS) facility boiler plant, building # 40, located at 3801 Miranda Ave., Palo Alto, CA, 94304.
The objective of this project is to retrofit three (3) existing VAPAHCS boilers to meet the safety standards required per Directive 1810, Master Specifications and Boiler Safety Manual, 8th Edition found on Technical Information Library (TIL) Technical Information Library (TIL) - Office of Construction & Facilities Management (va.gov), and to remove deficiencies as delineated in the Boiler Efficiency Institute (BEI) Boiler Safety Device Testing report dated July 20, 2023, attached herewith.
The scope of the project is to address the deficiencies listed in section 3.1 of the Statement of Work and identified in the BEI report with corresponding numbers. All contractor personnel must possess all certifications and licenses required by Local, State, and Federal jurisdictions to perform this work.
Please provide two quotes, one for each line item:
The contractor must provide all personnel, expertise, equipment, tools, materials, supervision, due diligence and other items and services necessary, as described in the Statement of Work, to retrofit three (3) boilers at boiler plant building # 40 located at VAPAHCS, 3801 Miranda Ave., Palo Alto, CA, 94304. Contractor must also provide as-built drawings of three boilers, showing as-built conditions of gas and steam valves, location of viewports and burner configuration. Format: 11x17 paper hard copy, and digital copy as pdf document. Performance period 200 calendar days.
The contractor must provide all personnel, expertise, equipment, tools, materials, supervision, due diligence and other items and services necessary, as described in the Statement of Work, to retrofit three (3) boilers at boiler plant building # 40 located at VAPAHCS, 3801 Miranda Ave., Palo Alto, CA, 94304. No As-built drawings provided. Performance period 180 calendar days.
Attachments/Links
Contact Information
Contracting Office Address
-
10535 HOSPITAL WAY
-
MATHER , CA 95655
-
USA
Secondary Point of Contact
History