| Location: | Ohio |
|---|---|
| Posted: | Sep 24, 2026 |
| Due: | Oct 1, 2026 |
| Agency: | City of Columbus |
| Type of Government: | State & Local |
| Category: |
|
| Solicitation No: | RFQ033746 |
| Publication URL: | To access bid details, please log in. |
| Basic Information | |
| Solicitation # | RFQ033746 |
| Solicitation Type | INF |
| Document Title | 6005-SMOC- STREET PLATES |
| Requesting Department | Sewers and Drains |
| Expiry Date Time (ET) | 10/1/2026, 1:00:00 PM |
| Delivery Date | 10/31/2026 |
| Delivery Name | Rick Bobbitt |
| Delivery Address |
1250 Fairwood Ave.
Columbus, OH 43206 USA |
| Attachment | Yes |
1-STREET PLATE 1 X 48 X 96. MADE FROM DOMESTIC STEEL, LIFTING BUNG INSTALLED, CENTERED TO BALANCE PLATE. LIFTING BUNGS SHALL BE 1 1/4-3.5 COIL TYPE THREAD (LIKE ACTEK #48803), REQUEST THE OWNERS NAME AND PHONE NUMBER BE LASER ETCHED INTO PLATE AS SHOWN IN DRAWING. ETCHING SHALL CONSIST OF LETTERS/NUMBERS AT LEAST 3” IN HEIGHT. 2-EXCAVATION COVER PLATE, ½” THICK X 60” X 24” ( ± 0.5” ). MADE FROM DOMESTIC STEEL. NO LIFTING BUNG WILL BE REQUIRED. REQUEST THE OWNERS NAME AND PHONE NUMBER BE LASER ETCHED INTO PLATE AS SHOWN IN DRAWING. ETCHING SHALL CONSIST OF LETTERS/NUMBERS AT LEAST 3” IN HEIGHT. Plate drawing can be found in attachments.
| RFQ Lines | |||||||
| Line Number | Line Type | Procurement Category | Item Number | Product Name | Quantity | Purch Unit | Currency |
| 1 | Category | Steel plate | STREET PLATE 1" THICK X 48" X 96" | 3 | EA | USD | |
| 2 | Category | Steel plate | EXCAVATION COVER PLATE | 4 | EA | USD | |
DWR-smoc
1. OWNER'S NAME. =
A 24 HOUR EMERGENCY CONTACT PHONE NUMBER= 2
STEELPL4TE
STREET
12" MIN. -
12" MIN.
12" MIN. OVERLAP REQUIRED (ALL
SYREET REACE SIDES) FROM EDGE OF EXCAVATION
CUT TO EDGE OF PLATE.
ALL STEEL PLATES MUST HAVE THE FOLLOWING INFORMATION
CLEARLY AND LEGIBLY ''EETTCCHHEEDD' INTO THEIR TOP SURFACE:
1. OWNER'S NAME.
2. A 24 HOUR EMERGENCY CONTACT PHONE NUMBER.
MINIMUM THICKNESS OF STEEL PLATES
SIZE OF PLATE THICKNESS
4'x 4 1/2"
4x6 3/4"
LARGER 1"
NO STEEL PINS ARE PERMITTED.
SEE SHEET 7 FOR SIGNING REQUIREMENTS.
STEEL PLATE REQUIREMENTS
PAVEMENT & UTILITY
CUT REPAIR
12" 12"
STANDARDS
STEEL PLATE
EXCAVATION E E EXISTING ITEM 448 (COLD MIX ONLY STD DWG
CUT PAVEMENT WITH APPROVAL BY THE CITY OF COLUMBUS, OHIO 1441
DIVISION OF PLANNING AND DEPARTMENT OF PUBLIC SERVICE
OPERATIONS) DIVISION OF DESIGN AND CONSTRUCTION
12/1/14
SHT 6 OF 7

With GovernmentContracts, you can:
...Button Color - Standard (ANSI) UL - None Ground pad stainless steel...
City of Columbus
Bid Due: 11/03/2026
...Description: Whirlpool 3.1 cu ft Mini Refrigerator Stainless Steel WH31S1E: Energy Star Certified ...
City of Columbus
Bid Due: 11/06/2026
...site inspections includes hard hat, safety glasses with side shields, and steel-toed boots. ...
Northeast Ohio Regional Sewer District
Bid Due: 11/02/2026
...at the NEORSD during site inspections are a hard hat, steel toed boots, ...
Northeast Ohio Regional Sewer District
Bid Due: 11/12/2026