CPO CLUB / MWR FITNESS / STORAGE BUILDING A-350

Location: Florida
Posted: Aug 25, 2025
Agency: DEPT OF DEFENSE
Type of Contract: Awards
Type of Government: Federal
Category:
  • Z - Maintenance, Repair or Alteration of Real Property
Solicitation No: N694502C1037
Publication URL: To access bid details, please log in.
Follow
CPO CLUB / MWR FITNESS / STORAGE BUILDING A-350
Active
Contract Opportunity
Notice ID
N694502C1037
Related Notice
Contract Line Item Number
0001
Department/Ind. Agency
DEPT OF DEFENSE
Sub-tier
DEPT OF THE NAVY
Major Command
NAVFAC
Sub Command
NAVFAC ATLANTIC CMD
Sub Command 2
NAVFAC SOUTHEAST
Office
NAVFACSYSCOM SOUTHEAST
Award Details
  • Contract Award Date: Aug 25, 2025
  • Contract Award Number: N6945025C1037
  • Task/Delivery Order Number:
  • Contractor Awarded Unique Entity ID: PFB9NQGRHMT8
  • Contractor Awarded Name: PARCON APC DESIGN BUILD, L.L.C
  • Contractor Awarded Address: Key West , FL 33040 USA
  • Base and All Options Value (Total Contract Value): $2,582,218.00
General Information
  • Contract Opportunity Type: Award Notice (Original)
  • Original Published Date: Aug 25, 2025 04:04 pm EDT
  • Inactive Policy: 15 days after contract award date
  • Original Inactive Date: Sep 09, 2025
  • Initiative:
    • None
Classification
  • Original Set Aside: 8(a) Sole Source (FAR 19.8)
  • Product Service Code: Z2JZ - REPAIR OR ALTERATION OF MISCELLANEOUS BUILDINGS
  • NAICS Code:
    • 236220 - Commercial and Institutional Building Construction
  • Place of Performance:
    Key West , FL 33040
    USA
Description

This project involves updates and renovations to Building A350 on NAS Key West, Boca Chica, Florida. This is a design-build project, requiring the contractor to procure the services of a Florida Licensed Professional Engineer, Designer of Record (DOR). The DOR will be responsible for all design-related activities, ensuring compliance with applicable Unified Facilities Criteria (UFC), Florida Building Code, ASCE 7-22, and U.S. Navy requirements.



Below is a high-level summary of the project. The project consists of multiple tasks:




  1. Replacement of the existing modified bitumen roof using a cold tar process. This task including replacement of all roof vents, Flashing/trim and other roof components.

  2. Replacement of three existing HVAC package units-Includes other work associated with the HVAC replacement such as the installation of new stainless steel disconnect switches, thermostats, control wire ect.. Replacement of the ground mounted DX unit (condenser and AHU)

  3. Exterior improvements- Include pressure washing, priming, painting the building white, and replacing all existing windows and doors with hurricane-rated products meeting UFC and Florida Building Code, ASCE 7-22 wind loads.

  4. Interior improvements (lights/ceiling)-Replace all of the interior light fixtures throughout the entire building in drop ceiling and bathroom. They shall also include replacement of all ceiling grid and drop in ceiling tiles.

  5. Interior improvements (plumbing) - Replace various plumbing fixtures that need throughout the buildings bathrooms and closets as stated within the technical section below.


Attachments/Links
Contact Information
Contracting Office Address
  • COMMANDING OFFICER B-903 YORKTOWN
  • NAS JACKSONVILLE , FL 32212-0030
  • USA
Primary Point of Contact


Secondary Point of Contact


History
  • Aug 25, 2025 04:04 pm EDTAward Notice (Original)
Daily notification on new contract opportunities

With GovernmentContracts, you can:

  • Find more opportunities and win more business
  • Receive daily alerts for all new bid opportunities
  • Get contract opportunities matched to your business
ONE WEEK FREE TRIAL
* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.