2023 Water Main Replacement Project 4

Location: Federal
Posted: May 13, 2026
Due: Jun 12, 2026
Agency: San Antonio Water System
Type of Government: State & Local
Category:
  • C - Architect and Engineering Services - Construction
  • Z - Maintenance, Repair or Alteration of Real Property
Solicitation No: CO-00907-RL
Publication URL: To access bid details, please log in.
2023 Water Main Replacement Project 4
Solicitation No. CO-00907-RL

Status: Currently Accepting Submissions

Due Date: 10:00 AM Friday, 6/12/26


Estimated Budget: $10,500,000.00

REQUEST FOR COMPETITIVE SEALED PROPOSALS

(RFCSP)

Solicitation No.CO-00907

Sealed proposals are requested by the San Antonio Water System for the construction of approximately 6,174 LF of 8-inch, 2,285 LF of 12-inch, 1,526 LF of 16-inch, 2,927 LF of 20-inch water main by Open Cut, 158 LF of 24-inch, 40 LF of 42-inch casing by pipe jacking construction method and street pavement repair in accordance with City of San Antonio street repair requirements, and all other associated appurtenances as included in the Contract Documents for the 2023 Water Main Replacement Project 4, SAWS Job No. 23-4005.

To view additional project information, as well as obtain the plans and specifications for this project, visit our website located at www.saws.org and click on the Business Center.  Then select Bidder, Consultant, and Vendor Registration, which is located on the left-hand side of the screen.  Select the Register Now button and proceed with registration.

For difficulties downloading plans and specifications, contact the Contracting Department at 210- 233-3341.

An in-personnon-mandatory pre-proposal meeting will be held at 9:00 A.M (CDT) on May 21, 2026, at the below location.

San Antonio Water System – Headquarters

2800 US Highway 281 North

Tower II, Conference Room 145

San Antonio, Texas 78212

For questions regarding this solicitation, technical questions or additional information, please contact Roxanne Lockhart, in writing via email to: roxanne.lockhart@saws.org or by fax to (210) 233-4438 until 3:00 P.M. (CDT) on May 26, 2026. Answers to the questions will be posted to the web site by 3:00 P.M. (CDT) on June 2, 2026, as a separate document or included as part of an addendum. Be advised that firms responding to this RFCSP (Respondents) are prohibited from communicating with any other SAWS staff, the Consultant, the Developer, or COSA officials regarding this RFCSP up until the contract is awarded as outlined in the Instructions to Respondents.

Proposals will be received electronically only, until 10:00 A.M. (CDT), June 12, 2026.  Electronicproposals will be received via Secure Share site.  See the Electronic Proposal Opening Instructions attachment for additional information regarding an electronic proposal submittal.  Electronic proposals shall be accompanied by a bid bond in an amount not less than five percent of the total proposal price.  (Or, if providing SAWS with a cashier's check or certified check in an amount not less than five percent of the total proposal price, SAWS will request this within 24 hours from the Respondent who did not submit a bid bond).  Proposals will then be publicly opened and read aloud by Contract Administration via WebEx.

Link: http://saws.webex.com

Meeting Number: 2480 401 3086

Meeting Password: CO-00907

Join by Phone: 210-233-2090

Respondents will need to submit a request by June 11, 2026, 10:00 A.M. (CDT) to receive access to the Secure Share File Drop link via email to roxanne.lockhart@saws.org .  Respondent’s email requesting access to the Secure Share FileDrop Link shall provide the legal name of the Respondent’s company and the intended recipient’s email address and phone number.  No requests for the File Drop link will be accepted after June 11, 2026, 10:00 A.M. (CDT).


Non-Mandatory
Pre-Bid

Meeting 9:00 AM, Thursday May. 21, 2026

In-Person at San Antonio Water System – Headquarters 2800 US Highway 281 North Tower II, Conference Room 145 San Antonio, Texas 78212

Notify Me


Receive updates sent straight to your inbox.
Subscribe
Plan Holders List
View plan holders list.
Downloads

Not logged in

Evaluation Criteria Forms (Word)


May. 13, 2026

Specifications


May. 13, 2026

Note: You must be logged in to access this document

Plans


May. 13, 2026

Note: You must be logged in to access this document

Geotechnical Data Report


May 13, 2026

Note: You will be prompted to login to access this document.



Questions? Please contact

Roxanne Lockhart

at 210-233-3095
|

Receive Email Updates
|

Registration Agreement

Attachment Preview

Evaluation Criteria Form

The intent of this document is to provide Respondents a structure for their responses. While there are page limits for this solicitation, there are no character limitations.

Respondents should provide answers to the questions below in the order and spaces provided to ensure continuity between Respondent's submissions.

When responding to the questions below, Respondents should use the space provided in this form, unless otherwise indicated.

If all fields are not completed, the proposal may be deemed non-responsive.

Team Qualifications and Experience (15 Points)

Organizational Structure and Information of the Prime Contractor

Provide current business organizational structure, type of business structure, and stability of organization.

Provide total number of employees and annual company revenues as of December 31, 2025.

Provide Debarment history for the company for the last ten (10) years.

Provide any litigation, arbitration, and claims history for the last three (3) years and any litigation, arbitration, and claims history with SAWS regardless of the year they occurred.

Indicate the number of years performing contracting/construction work under current legal business name and/or previous legal business name(s).

Provide company financial information as follows:

Respondent must clearly indicate the entity being proposed to enter into the Contract. In order to supplement the financial strength of the entity being proposed to enter into the Contract, the Respondent may, but is not required to, propose a guarantor who will guaranty the Contractor's obligations under the Contract through a separately executed guaranty Contract in favor of SAWS. Only the financial information of (1) the entity being proposed to enter into the Contract, and (2) a Guarantor, if proposed, will be considered in the financial evaluation of the RFCSP.

SAWS in its sole discretion may reject any Respondent that does not possess the financial strength and capacity to undertake this project and the obligations and liabilities thereof. Subject to the complete review and finding of acceptability of the submitted financial information, Respondents

demonstrating an ability to provide the required performance and payment bonds and the ability to maintain a minimum aggregate net worth sufficient to undertake this project, as measured by either the Respondent or a proposed Guarantor, shall be deemed to have the financial strength and capacity to undertake the project.

The Respondent shall submit the financial information set forth below for the entity being proposed to enter into the Contract and any proposed guarantor. If Respondent is not a public company and believes any of its financial information is exempt from disclosure to third parties under the Texas Public Information Act in Chapter 552 of the Texas Government Code, the Respondent must clearly label the specific portions sought to be kept confidential and specify the exemption that the Respondent is relying upon. However, SAWS does not represent or guarantee in any way that Respondent's financial statements will be protected from disclosure, even if identified by Respondent as confidential or proprietary, in the event of a Public Information Request under Texas Government Code Chapter 552. SAWS will notify the Respondent of any public information requests relating to financial information marked as confidential by the Respondent, and the Respondent shall be responsible for defending its basis for exemption from disclosure in accordance with the Act.

If Respondent is organized as a corporation, partnership, LLP, LLC or joint venture, submit a complete financial statement, prepared in accordance with generally accepted accounting principles, for the most recent complete fiscal year. Footnote disclosures must accompany the submitted year to date financial statement. If available, financial statements audited or certified by an independent certified public accountant should be submitted; otherwise, a notarized statement certifying the accuracy of the financial information and signed by an officer of the proposing entity must accompany the financial information. If any entity has been in existence less than year, the information shall be provided for the period of existence.

If Respondent intends to organize as a partnership, LLP, LLC, or joint venture, then the above- referenced financial information of each partner, LLC/LLP member or joint-venture member must be submitted.

SAWS reserves the right to obtain a Dun and Bradstreet financial report, or other credit report, at its own cost, and all members of your Team, responding to this RFCSP agrees to allow SAWS to obtain such report(s) on your Team members and all partners, affiliates and sub-consultants, if any, to facilitate SAWS financial evaluation of the Respondent.

Proposed Team Structure and Key Personnel Roles and Responsibilities

(Prior to responding to this section, refer to the Supplementary Instructions to Respondents for definitions and other requirements.)

Provide a 1-page organizational chart that describes the composition of the team for this project. The chart shall include proposed Key Personnel for the Prime Contractor and Key Subcontractor(s). The chart shall also include percent availability (as percentage of total individual's workload) for Key Personnel (Prime and Key Subcontractor(s)) and their proposed role for the duration of the Project.

Note: Insert Organizational Chart here or in the next page.

Note: Insert Organizational Chart here or in the previous page.

Provide a clear description of the proposed team identifying Key Subcontractor(s), their role on the project, and teaming history. If the Prime Contractor has not worked previously with proposed Key Subcontractor(s), describe the proposed approach for ensuring successful completion of the project in accordance with Contract Documents.

(Use the table provided below. Add rows as needed based on the proposed team for this project.)

Describe teaming history between Prime Contractor and proposed Key Subcontractor(s):

Describe Proposed approach for managing Subcontractor(s), including Key Subcontractor(s):

Provide a clear description of the proposed team's Key Personnel roles and responsibilities, including Key Personnel from Key Subcontractor(s).

(Use the table provided below. Add rows as needed based on the proposed team composition for this project.)

Qualifications and Experience of Key Personnel Proposed for this Project

Using separate 8 12" x 11" sheet(s), titled "Team Qualifications and Experience - Resume" inserted immediately following this section:

Provide resumes for Key Personnel for the Prime Contractor and Key Subcontractor(s) identified on the organizational chart, one per person, not to exceed one (1) page each with the Project Manager's resume being first.

(As part of this criteria, use the check boxes below as a checklist to help ensure the information above is understood and information provided follows the guidelines listed above.)

Project Manager's resume is first

Resumes for all Key Personnel for the Prime Contractor have been included Resumes for all Key Personnel for the Prime Contractor have been identified

on the organizational chart

Resumes for all Key Personnel for the Prime Contractor do not exceed one

(1) page each

Resumes for all Key Personnel for the Key Subcontractor(s) have been included

Resumes for all Key Personnel for the Key Subcontractor(s) have been identified on the organizational chart

Resumes for all Key Personnel for the Key Subcontractor(s) do no exceed one (1) page each

All resumes provided include the following information:

Name, job title, education

Number of years of total professional experience

Number of years/months with current firm

Number of years/months of experience in proposed role for this project

Description of professional qualifications to include degrees, licenses, certifications, and associations

Brief overview of professional experience

Detailed description of capabilities and experience relevant to this project

List of all other active projects the team member is assigned to for the duration of the Project, to include the phase and percentage of time allocated to each of the other projects. For each project included in each resume, please clearly identify whether the project is with current firm or part of the person's past professional experience.

Note: Insert 1-page resumes here for Key Personnel for the Prime Contractor and Key Subcontractor(s) identified on the organizational chart

One (1) resume per page.

END OF TEAM QUALIFICATIONS AND EXPERIENCE CRITERIA

Quality, Reputation, and Ability to Deliver Projects on Schedule and within Budget (20 Points)

Prime Contractor On-Time Completion on Similar Projects in the Past Ten (10) Years

Use the tables provided below to respond to the following:

List and describe five (5) completed projects within the last ten (10) years of similar size, scope, and complexity to the work described in the Contract Documents for this Project. At least two of the reference projects must involve installation of HDPE potable water main 8-inch diameter or larger. At least two of the reference projects must involve installation of potable water main 16-inch diameter or larger, regardless of pipe material. At least one of the projects must involve pipe jacking. Respondents should provide references with contact information to include a valid, recently verified email and telephone number for each project listed.

Key Personnel must have participated in a minimum of one (1) of the three (3) projects listed. Project Superintendent must have participated in a minimum of one (1) of the three

(3) projects listed. QC Manager must have participated in a minimum of one (1) of three

(3) projects listed. Other Key Personnel must have participated in a minimum one (1) of the three (3) projects listed. Key Personnel's role on project reference must have been the same as the role proposed for this Project.

If Respondent has similar (size, scope, and complexity) SAWS experience, at a minimum, one (1) SAWS project must be included in the list of three (3) projects provided.

If valid contact information is not provided, the project will not be considered and the Respondent's score for this criterion may be reduced and/or Respondent's proposal may be deemed non-responsive.

Project #1

Project #2

Project #3

Project #4

Project #5

iii. Respondent shall provide a list of all current and recently completed improvement, upgrades, rehabilitation and new construction of potable water high service pump station and production facility projects performed in the last five (5) years for all Utility Owners in the State of Texas. Respondent shall provide the following information for each project.

(Use the table provided below to respond. Repeat the table as many times as needed to provide the information requested for all relevant projects.)

Project #1

The Respondent shall provide a list of all projects currently under construction in which Key Personnel are involved, as identified in the organizational chart provided in the response for this RFCSP, and the expected completion date that demonstrates Respondent's ability to start and complete the work required by the project.

(Use the table provided below to respond. Insert additional rows to the table above, as needed.)

Key Subcontractors Performance on Similar Projects in the Past Ten (10) Years

(Use the tables provided below to respond)

If a Key Subcontractor is proposed for the type of work indicated, provide a list of two

(2) projects that the identified HDPE Fusing Subcontractor has completed within the last ten (10) years. The projects must be of similar size, scope, and complexity to the work described in the Contract Documents. Subcontractor's Project Manager and/or Project Superintendent shall have participated in a minimum of one of the two (2) projects. Key Personnel's role on project reference must have been the same as the role proposed for this Project.

If a Key Subcontractor is proposed for the type of work indicated, provide a list of two

(2) projects that the identified Pipe Jacking Subcontractor has completed within the last ten (10) years. The projects must be of similar size, scope, and complexity to the work described in the Contract Documents. Subcontractor's Project Manager and/or Project Superintendent shall have participated in a minimum of one of the two (2) projects. Key Personnel's role on project reference must have been the same as the role proposed for this Project.

If a Key Subcontractor is proposed for another type of work, indicate the type in the following blank space and provide a list of two (2) projects that the identified Subcontractor has completed within the last ten (10) years. The projects must be of

similar size, scope, and complexity to the work described in the Contract Documents. Subcontractor's Project Manager and Project Superintendent shall have participated in a minimum of one of the two (2) projects. Key Personnel's role on project reference must have been the same as the role proposed for this Project.

If Prime Contractor is planning to self-perform the Work in accordance with the Contract Documents and no Key Subcontractor(s) have been identified in the Response, Respondent shall provide a list of two (2) additional projects, for each Key Subcontractor role being replaced, that were of similar scope to the Work that would have been performed by the Key Subcontractor being replaced and that have been completed in the State of Texas within the last ten (10) years. Prime Contractor's Key Personnel shall have participated in a minimum of one (1) of the two (2) projects listed, for each Key Subcontractor role being replaced. Describe the role served by the proposed staff on those projects.

If valid contact information is not provided, the project will not be considered and the Respondent's score for this criterion may be reduced and/or Respondent's proposal may be deemed non-responsive.

Key HDPE Fusing Subcontractor Performance Project #1

Key HDPE Fusing Subcontractor Performance Project #2

Key Pipe Jacking Subcontractor Performance Project #1

Key Pipe Jacking Subcontractor Performance Project #2

Key Subcontractor Performance Project #1

Key Subcontractor Performance Project #2

Prime Contractor Safety Performance on Similar Projects

Provide records showing Total Recordable Incident Rate (TRIR) for the past three (3) years for the Prime Contractor. If Respondent's TRIR for any year provided is greater than four (4), Respondent shall provide documentation detailing measures, additional training, and steps taken to improve Respondent's safety record.

Provide records detailing all formal Complaints, Inquiries, Investigations, and/or Violations by OSHA or any state or local level OSHA program for the past three (3) years for the Prime Contractor.

List all fatalities in the company's safety history for the Prime Contractor. If Respondent has fatalities in their record, they shall provide a detailed description of corrective measures taken, new or additional safety training provided, and process improvements made to prevent near-miss incidents and fatalities since the occurrence of each fatality.

Safety Information for Key Subcontractor(s) Similar Projects

Provide records showing Total Recordable Incident Rate (TRIR) for the past three (3) years for Key Subcontractor(s). If the TRIR is greater than four (4) for any year provided, the Key Subcontractor (s) shall provide documentation detailing measures, additional training, and steps taken to improve the company's safety record.

Provide records detailing all formal Complaints, Inquiries, Investigations, and/or Violations by OSHA or any state or local level OSHA program for the past three (3) years for Key Subcontractor(s).

List all fatalities in the company's safety history for Key Subcontractor(s). If Key

Subcontractor(s) had fatalities in their record, provide a detailed description of corrective measures taken, new or additional safety training provided, and process improvements made to prevent near-miss incidents and fatalities since the occurrence of each fatality.

END OF QUALITY, REPUTATION, AND ABILITY TO DELIVER PROJECTS ON SCHEDULE AND WITHIN BUDGET CRITERIA

Project Approach, Schedule, and Availability (15 Points)

Project Approach

Provide a narrative of the project approach describing how the Respondent will complete this project. Include key milestones, specific critical processes and critical path items, submittals and shop drawings, phases and/or sequencing, coordination of trades and disciplines, permits, approvals, coordination with SAWS staff, coordination with other contractors and projects, coordination with permitting agencies and project stakeholders, and procurement of critical equipment and materials anticipated to complete the project work. Identify potential risks and describe proposed mitigation measures to ensure on-time completion of the Project.

Explain how Respondent will coordinate with other utility providers (e.g., CPS Energy) involved in the project to ensure timely completion of their activities as they relate to this project. Explain how Respondent will coordinate with Owner's Operations staff throughout the Project. Describe how the Respondent will coordinate with business owners being impacted by the Project. Describe the Respondent's approach for securing permits (e.g., ROW, SWPPP, etc.) and/or complying with permit requirements for which the System is the permit holder (City of San Antonio Transportation and Capital Improvements Department, City of San Antonio Fiesta Parade, San Antonio Water System Hildebrand Tank operators, CoSA Arborist, etc.)

Provide a description of proposed water tie-in and shutdown plan, sequence of critical path construction activities, coordination with subcontractors for various trades and disciplines, advanced coordination with Owner, and opportunities for reduced downtime, etc.

Provide a description of the approach specifically addressing the procurement of the following items: valves, pipe, HDPE fusing equipment (including those needed for 16 and 20-inch pipe sizes), and other long-lead time equipment and devices.

Provide any innovative ideas for cost savings (construction sequencing, method or construction duration, supply chain management and logistics, procurement of critical items, and availability of materials and equipment) for this project.

Provide a Quality Management Plan (QMP) describing how the Prime Contractor will ensure that the necessary steps, safeguards, subcontractor oversight, QC processes, and document controls will be implemented in a rigorous manner as to ensure the completeness, workmanship, accuracy, and timely completion of the Project.

Project Schedule and Unforeseen Conditions

Provide a critical path method (CPM) schedule in Primavera or Microsoft Project. The schedule shall include milestones, specific critical processes and critical path items, construction phases, permits and approvals, coordination with stakeholders, security clearances, and procurements anticipated to complete the project work. The anticipated

notice to proceed (NTP) for this Project is September 14, 2026. Respondent shall use this date for developing the proposed project schedule.

Use separate sheet(s), titled "Project Approach including Delivery Schedule - CPM Milestone Schedule" inserted immediately following this Section. 11" x 17" paper is permitted.

Explain how Respondent will complete the project within the schedule taking into account the existing commitments identified in 2.a.iv.

Identify long-lead items and critical path shop drawing submittals.

Provide details for the procurement and delivery of valves, pipe, HDPE fusing equipment (including those needed for 16 and 20-inch pipe sizes), and other long-lead time equipment and devices.

From past project experience, list and describe any previous instances in which the Contractor has encountered unforeseen conditions.

Identify whether a recovery plan was required.

Describe the nature of the issue and whether it was promptly resolved or resulted in the Respondent being asked to demobilize.

As part of the criteria, use the check boxes below as a checklist to help ensure guidelines are met. Repeat the table below as many times as needed to provide the information requested.

Describe the Respondent's approach towards mitigating and managing unforeseen conditions should they be encountered during the construction of this Project.

SAWS, in reviewing Respondents' proposals, is looking for Respondents that can meet all necessary milestones and complete the work within the Contract time given for

completion. A Respondent's inability to meet milestones and complete the Work in the time provided may result in the Respondent's score for these criteria being reduced and/or Respondent's proposal deemed non-responsive.

Availability of Key Personnel and Equipment

Describe availability of Key Personnel (Respondent and Key Subcontractor(s)) that will be specifically assigned to this Project.

Describe availability of equipment and facilities that will be specifically utilized for this Project.

Corresponding with the organizational chart provided, list the available workforce for the various disciplines required for this project including the number of work crews, and number of personnel for each skill classification proposed to complete the work.

END OF PROJECT APPROACH, SCHEDULE, AND AVAILABILITY CRITERIA

Team Member Company Name Proposed Role Worked with in the Past Worked with in the Past
Prime Contractor
Key Subcontractor #1 Yes No
Key Subcontractor #2 Yes No
Key Subcontractor #3 Yes No
Key Subcontractor #4 Yes No
Key Subcontractor #5 Yes No
Team Member Proposed Key Personnel Role Name of Key Personnel Included in Org Chart? Included in Org Chart?
Prime Contractor Project Manager Yes No
Prime Contractor Superintendent Yes No
Prime Contractor QC Manager Yes No
Prime Contractor Other: Yes No
Key Subcontractor #1 Project Manager Yes No
Superintendent Yes No
Other: Yes No
Key Subcontractor #2 Project Manager Yes No
Superintendent Yes No
Other: Yes No
Key Subcontractor #3 Project Manager Yes No
Team Member Proposed Key Personnel Role Name of Key Personnel Included in Org Chart? Included in Org Chart?
Superintendent Yes No
Other: Yes No
Key Subcontractor #4 Project Manager Yes No
Superintendent Yes No
Other: Yes No
Key Subcontractor #5 Project Manager Yes No
Superintendent Yes No
Other: Yes No
Project Name:
Provide City & State of the Project location: (Note: Representative projects or contracts completed outside of the United States will NOT be accepted due to differing laws, regulations, and practices.)
Utility/Owner name:
Utility/Owner Project Manager's name and contact information to include a valid, recently verified email and telephone number:
Proposed Contractor's Key Personnel who participated on this project:
Key Personnel's role on this project:
Project completed within the last ten (10) years: Yes No
Project has similar size, scope, and complexity to the work described in the Contract Documents: Yes No
-Similar Linear Footage Installed (Provide Linear Footage) Yes No
-Provide Pipe Size and footage per size (Indicate water or sewer) (Note: add more lines if necessary) LF of LF of inch inch Water Water Sewer Sewer
LF of inch Water Sewer
LF of inch Water Sewer
LF of inch Water Sewer
LF of inch Water Sewer
-Did this project have bore or tunneling (Self Performed or Sub) Yes No Other Trenchless? Self Perform Sub (Sub Name) Yes No Other Trenchless? Self Perform Sub (Sub Name) Yes No Other Trenchless? Self Perform Sub (Sub Name) Yes No Other Trenchless? Self Perform Sub (Sub Name) Yes No Other Trenchless? Self Perform Sub (Sub Name)
-Provide Pipe Size and footage per size for BORE work (Indicate water or sewer) (Note: add more lines if necessary) LF of LF of inch inch Water Water Sewer Sewer
LF of inch Water Sewer
LF of inch Water Sewer
LF of inch Water Sewer
LF of inch Water Sewer
Detailed project description and explanation for why it is comparable to the size, scope and complexity for this item: (Note: please include sufficient project details so similarity and applicability of project reference can be determined. Include details like materials of construction, construction methods, soil conditions, construction conditions (within roadways, in drainage channels, within parks, etc.), affected agencies (CPS Energy, TxDOT, etc.), and other specific project details.)
Original bid/price and final construction in place costs: $ Original Bid; $ Final Construction Cost
Total number AND cost for all change orders, as well as an explanation regarding the reason for specific change orders: Total # of Change Orders $ Total Amount of COs Explain COs:
Construction Contract Notice to Proceed (NTP) Date:
Identify whether the project was completed on-time and within budget: On-time: Yes No Within budget: Yes No
Original Contract Completion Date and Actual Completion Date: Original Date; Actual Date
Actual number of days beyond the original contract:
Actual number of days added through change orders.
The recovery schedule/plan and implementation of such, if it was required. If a recovery/plan schedule was implemented, describe whether the project was successfully brought back on schedule. Please discuss, as necessary and deemed appropriate.
Highlight prime contractor's public and other agency coordination efforts on this project.
Project Name:
Provide City & State of the Project location: (Note: Representative projects or contracts completed outside of the United States will NOT be accepted due to differing laws, regulations, and practices.)
Utility/Owner name:
Utility/Owner Project Manager's name and contact information to include a valid, recently verified email and telephone number:
Proposed Contractor's Key Personnel who participated on this project:
Key Personnel's role on this project:
Project completed within the last ten (10) years: Yes No
Project has similar size, scope, and complexity to the work described in the Contract Documents: Yes No
-Similar Linear Footage Installed (Provide Linear Footage) Yes No
-Provide Pipe Size and footage per size (Indicate water or sewer) (Note: add more lines if necessary) LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer
-Did this project have bore or tunneling (Self Performed or Sub) Yes No Other Trenchless? Self Perform Sub (Sub Name)
-Provide Pipe Size and footage per size for BORE work (Indicate water or sewer) (Note: add more lines if necessary) LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer
Detailed project description and explanation for why it is comparable to the size, scope and complexity for this item: (Note: please include sufficient project details so similarity and applicability of project reference can be determined. Include details like materials of construction, construction methods, soil conditions, construction conditions (within roadways, in drainage channels, within parks, etc.), affected agencies (CPS Energy, TxDOT, etc.), and other specific project details.)
Original bid/price and final construction in place costs: $ Original Bid; $ Final Construction Cost
Total number AND cost for all change orders, as well as an explanation regarding the reason for specific change orders: Total # of Change Orders $ Total Amount of COs Explain COs:
Construction Contract Notice to Proceed (NTP) Date:
Identify whether the project was completed on-time and within budget: On-time: Yes No Within budget: Yes No
Original Contract Completion Date and Actual Completion Date: Original Date; Actual Date
Actual number of days beyond the original contract:
Actual number of days added through change orders.
The recovery schedule/plan and implementation of such, if it was required. If a recovery/plan schedule was implemented, describe whether the project was successfully brought back on schedule. Please discuss, as necessary and deemed appropriate.
Highlight prime contractor's public and other agency coordination efforts on this project.
Project Name:
Provide City & State of the Project location: (Note: Representative projects or contracts completed outside of the United States will NOT be accepted due to differing laws, regulations, and practices.)
Utility/Owner name:
Utility/Owner Project Manager's name and contact information to include a valid, recently verified email and telephone number:
Proposed Contractor's Key Personnel who participated on this project:
Key Personnel's role on this project:
Project completed within the last ten (10) years: Yes No
Project has similar size, scope, and complexity to the work described in the Contract Documents: Yes No
-Similar Linear Footage Installed (Provide Linear Footage) Yes No
-Provide Pipe Size and footage per size (Indicate water or sewer) (Note: add more lines if necessary) LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer
-Did this project have bore or tunneling (Self Performed or Sub) Yes No Other Trenchless? Self Perform Sub (Sub Name)
-Provide Pipe Size and footage per size for BORE work (Indicate water or sewer) (Note: add more lines if necessary) LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer
Detailed project description and explanation for why it is comparable to the size, scope and complexity for this item: (Note: please include sufficient project details so similarity and applicability of project reference can be determined. Include details like materials of construction, construction methods, soil conditions, construction conditions (within roadways, in drainage channels, within parks, etc.), affected agencies (CPS Energy, TxDOT, etc.), and other specific project details.)
Original bid/price and final construction in place costs: $ Original Bid; $ Final Construction Cost
Total number AND cost for all change orders, as well as an explanation regarding the reason for specific change orders: Total # of Change Orders $ Total Amount of COs Explain COs:
Construction Contract Notice to Proceed (NTP) Date:
Identify whether the project was completed on-time and within budget: On-time: Yes No Within budget: Yes No
Original Contract Completion Date and Actual Completion Date: Original Date; Actual Date
Actual number of days beyond the original contract:
Actual number of days added through change orders.
The recovery schedule/plan and implementation of such, if it was required. If a recovery/plan schedule was implemented, describe whether the project was successfully brought back on schedule. Please discuss, as necessary and deemed appropriate.
Highlight prime contractor's public and other agency coordination efforts on this project.
Project Name:
Provide City & State of the Project location: (Note: Representative projects or contracts completed outside of the United States will NOT be accepted due to differing laws, regulations, and practices.)
Utility/Owner name:
Utility/Owner Project Manager's name and contact information to include a valid, recently verified email and telephone number:
Proposed Contractor's Key Personnel who participated on this project:
Key Personnel's role on this project:
Project completed within the last ten (10) years: Yes No
Project has similar size, scope, and complexity to the work described in the Contract Documents: Yes No
-Similar Linear Footage Installed (Provide Linear Footage) Yes No
-Provide Pipe Size and footage per size (Indicate water or sewer) (Note: add more lines if necessary) LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer
-Did this project have bore or tunneling (Self Performed or Sub) Yes No Other Trenchless? Self Perform Sub (Sub Name)
-Provide Pipe Size and footage per size for BORE work (Indicate water or sewer) (Note: add more lines if necessary) LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer
Detailed project description and explanation for why it is comparable to the size, scope and complexity for this item: (Note: please include sufficient project details so similarity and applicability of project reference can be determined. Include details like materials of construction, construction methods, soil conditions, construction conditions (within roadways, in drainage channels, within parks, etc.), affected agencies (CPS Energy, TxDOT, etc.), and other specific project details.)
Original bid/price and final construction in place costs: $ Original Bid; $ Final Construction Cost
Total number AND cost for all change orders, as well as an explanation regarding the reason for specific change orders: Total # of Change Orders $ Total Amount of COs Explain COs:
Construction Contract Notice to Proceed (NTP) Date:
Identify whether the project was completed on-time and within budget: On-time: Yes No Within budget: Yes No
Original Contract Completion Date and Actual Completion Date: Original Date; Actual Date
Actual number of days beyond the original contract:
Actual number of days added through change orders.
The recovery schedule/plan and implementation of such, if it was required. If a recovery/plan schedule was implemented, describe whether the project was successfully brought back on schedule. Please discuss, as necessary and deemed appropriate.
Highlight prime contractor's public and other agency coordination efforts on this project.
Project Name:
Provide City & State of the Project location: (Note: Representative projects or contracts completed outside of the United States will NOT be accepted due to differing laws, regulations, and practices.)
Utility/Owner name:
Utility/Owner Project Manager's name and contact information to include a valid, recently verified email and telephone number:
Proposed Contractor's Key Personnel who participated on this project:
Key Personnel's role on this project:
Project completed within the last ten (10) years: Yes No
Project has similar size, scope, and complexity to the work described in the Contract Documents: Yes No
-Similar Linear Footage Installed (Provide Linear Footage) Yes No
-Provide Pipe Size and footage per size (Indicate water or sewer) (Note: add more lines if necessary) LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer
-Did this project have bore or tunneling (Self Performed or Sub) Yes No Other Trenchless? Self Perform Sub (Sub Name)
-Provide Pipe Size and footage per size for BORE work (Indicate water or sewer) (Note: add more lines if necessary) LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer
Detailed project description and explanation for why it is comparable to the size, scope and complexity for this item: (Note: please include sufficient project details so similarity and applicability of project reference can be determined. Include details like materials of construction, construction methods, soil conditions, construction conditions (within roadways, in drainage channels, within parks, etc.), affected agencies (CPS Energy, TxDOT, etc.), and other specific project details.)
Original bid/price and final construction in place costs: $ Original Bid; $ Final Construction Cost
Total number AND cost for all change orders, as well as an explanation regarding the reason for specific change orders: Total # of Change Orders $ Total Amount of COs Explain COs:
Construction Contract Notice to Proceed (NTP) Date:
Identify whether the project was completed on-time and within budget: On-time: Yes No Within budget: Yes No
Original Contract Completion Date and Actual Completion Date: Original Date; Actual Date
Actual number of days beyond the original contract:
Actual number of days added through change orders.
The recovery schedule/plan and implementation of such, if it was required. If a recovery/plan schedule was implemented, describe whether the project was successfully brought back on schedule. Please discuss, as necessary and deemed appropriate.
Highlight prime contractor's public and other agency coordination efforts on this project.
Project Name:
Utility / Owner Name:
Date of Notice to Proceed:
Original Contract Time (calendar days or working days):
Original Contract Completion Date:
Actual Contract Completion Date (if not complete, provide % complete based on Contract Time):
Original Bid Price / Price Proposal:
Final Construction In-place Cost (if not complete, provide percent (%) complete based on Contract Value and most recent application for payment):
Was the project completed on-time? Yes No
Was the project completed within budget? Yes No
Key Personnel Name Company Affiliation Project Name % Time Allocated Project Completion Date
Name of Sub-Contractor:
Project Name:
Provide City & State of the Project location: (Note: Representative projects or contracts completed outside of the United States will NOT be accepted due to differing laws, regulations, and practices.)
Identify if the Project was performed by Sub-Contractor or if Prime Contractor Self-Performed
Utility/Owner name:
Utility/Owner Project Manager's name: and contact information to include a valid, recently verified email and telephone number:
Proposed Key Subcontractor's Key Personnel who participated on this project:
Key Personnel's role on this project:
Project completed within the last ten (10) years: Yes No Yes No Yes No
Key Sub-Contractor's Key Personnel involved in this Project were identified on the organizational chart: Yes No Yes No Yes No
Project has similar size, scope, and complexity to the work described in the Contract Documents: Yes No Yes No Yes No
-Similar Linear Footage Installed (Provide Linear Footage) Yes No Yes No Yes No
LF of inch Water Sewer
LF of inch Water Sewer
-Provide Pipe Size and footage per size (Indicate water or sewer) (Note: add more lines if necessary) LF of inch LF of inch Water Water Sewer Sewer
LF of inch Water Sewer
LF of inch Water Sewer
LF of inch Water Sewer
-Provide Pipe Size and footage per size for BORE work (Indicate water or sewer) (Note: add more lines if necessary) LF of inch LF of inch Water Water Sewer Sewer
LF of inch Water Sewer
LF of inch Water Sewer LF of inch Water Sewer
Detailed project description and explanation for why it is comparable to proposed Key Subcontractor's role on the Project:
Original bid/price and final construction in place costs: $ Original Bid; $ Final Construction Cost
Total number AND cost for all change orders, as well as an explanation regarding the reason for specific change orders: Total # of Change Orders $ Total Amount of COs Explain COs:
Construction Contract Notice to Proceed (NTP) Date:
Identify whether the Project was completed on-time and within budget: On time: Yes No Within budget: Yes No
Original Contract Time (specify Calendar Days or Working Days): Days (Calendar / Working)
Original Contract Completion Date and Actual Completion Date: Original Date; Actual Date
Original Contract Completion Date and Actual Completion Date:
Actual number of days beyond the original contract:
Actual number of days added through change orders.
The recovery schedule/plan and implementation of such, if it was required. If a recovery/plan schedule was implemented, describe whether the project was successfully brought back on schedule. Please discuss, as necessary and deemed appropriate.
Name of Sub-Contractor:
Project Name:
Provide City & State of the Project location: (Note: Representative projects or contracts completed outside of the United States will NOT be accepted due to differing laws, regulations, and practices.)
Identify if the Project was performed by Sub-Contractor or if Prime Contractor Self-Performed
Utility/Owner name:
Utility/Owner Project Manager's name: and contact information to include a valid, recently verified email and telephone number:
Proposed Key Subcontractor's Key Personnel who participated on this project:
Key Personnel's role on this project:
Project completed within the last ten (10) years: Yes No
Key Sub-Contractor's Key Personnel involved in this Project were identified on the organizational chart: Yes No
Project has similar size, scope, and complexity to the work described in the Contract Documents: Yes No
-Similar Linear Footage Installed (Provide Linear Footage) Yes No
-Provide Pipe Size and footage per size (Indicate water or sewer) (Note: add more lines if necessary) LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer
-Provide Pipe Size and footage per size for BORE work (Indicate water or sewer) (Note: add more lines if necessary) LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer
LF of inch Water Sewer LF of inch Water Sewer
Detailed project description and explanation for why it is comparable to proposed Key Subcontractor's role on the Project:
Original bid/price and final construction in place costs: $ Original Bid; $ Final Construction Cost
Total number AND cost for all change orders, as well as an explanation regarding the reason for specific change orders: Total # of Change Orders $ Total Amount of COs Explain COs:
Construction Contract Notice to Proceed (NTP) Date:
Identify whether the Project was completed on-time and within budget: On time: Yes No Within budget: Yes No
Original Contract Time (specify Calendar Days or Working Days): Days (Calendar / Working)
Original Contract Completion Date and Actual Completion Date: Original Date; Actual Date
Original Contract Completion Date and Actual Completion Date:
Actual number of days beyond the original contract:
Actual number of days added through change orders.
The recovery schedule/plan and implementation of such, if it was required. If a recovery/plan schedule was implemented, describe whether the project was successfully brought back on schedule. Please discuss, as necessary and deemed appropriate.
Name of Sub-Contractor:
Project Name:
Provide City & State of the Project location: (Note: Representative projects or contracts completed outside of the United States will NOT be accepted due to differing laws, regulations, and practices.)
Identify if the Project was performed by Sub-Contractor or if Prime Contractor Self-Performed
Utility/Owner name:
Utility/Owner Project Manager's name: and contact information to include a valid, recently verified email and telephone number:
Proposed Key Subcontractor's Key Personnel who participated on this project:
Key Personnel's role on this project:
Project completed within the last ten (10) years: Yes No
Key Sub-Contractor's Key Personnel involved in this Project were identified on the organizational chart: Yes No
Project has similar size, scope, and complexity to the work described in the Contract Documents: Yes No
-Similar Linear Footage Installed (Provide Linear Footage) Yes No
-Provide Pipe Size and footage per size (Indicate water or sewer) (Note: add more lines if necessary) LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer
-Provide Pipe Size and footage per size for BORE work (Indicate water or sewer) (Note: add more lines if necessary) LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer
LF of inch Water Sewer LF of inch Water Sewer
Detailed project description and explanation for why it is comparable to proposed Key Subcontractor's role on the Project:
Original bid/price and final construction in place costs: $ Original Bid; $ Final Construction Cost
Total number AND cost for all change orders, as well as an explanation regarding the reason for specific change orders: Total # of Change Orders $ Total Amount of COs Explain COs:
Construction Contract Notice to Proceed (NTP) Date:
Identify whether the Project was completed on-time and within budget: On time: Yes No Within budget: Yes No
Original Contract Time (specify Calendar Days or Working Days): Days (Calendar / Working)
Original Contract Completion Date and Actual Completion Date: Original Date; Actual Date
Original Contract Completion Date and Actual Completion Date:
Actual number of days beyond the original contract:
Actual number of days added through change orders.
The recovery schedule/plan and implementation of such, if it was required. If a recovery/plan schedule was implemented, describe whether the project was successfully brought back on schedule. Please discuss, as necessary and deemed appropriate.
Name of Sub-Contractor:
Project Name:
Provide City & State of the Project location: (Note: Representative projects or contracts completed outside of the United States will NOT be accepted due to differing laws, regulations, and practices.)
Identify if the Project was performed by Sub-Contractor or if Prime Contractor Self-Performed
Utility/Owner name:
Utility/Owner Project Manager's name: and contact information to include a valid, recently verified email and telephone number:
Proposed Key Subcontractor's Key Personnel who participated on this project:
Key Personnel's role on this project:
Project completed within the last ten (10) years: Yes No
Key Sub-Contractor's Key Personnel involved in this Project were identified on the organizational chart: Yes No
Project has similar size, scope, and complexity to the work described in the Contract Documents: Yes No
-Similar Linear Footage Installed (Provide Linear Footage) Yes No
-Provide Pipe Size and footage per size (Indicate water or sewer) (Note: add more lines if necessary) LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer
-Provide Pipe Size and footage per size for BORE work (Indicate water or sewer) (Note: add more lines if necessary) LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer
LF of inch Water Sewer LF of inch Water Sewer
Detailed project description and explanation for why it is comparable to proposed Key Subcontractor's role on the Project:
Original bid/price and final construction in place costs: $ Original Bid; $ Final Construction Cost
Total number AND cost for all change orders, as well as an explanation regarding the reason for specific change orders: Total # of Change Orders $ Total Amount of COs Explain COs:
Construction Contract Notice to Proceed (NTP) Date:
Identify whether the Project was completed on-time and within budget: On time: Yes No Within budget: Yes No
Original Contract Time (specify Calendar Days or Working Days): Days (Calendar / Working)
Original Contract Completion Date and Actual Completion Date: Original Date; Actual Date
Original Contract Completion Date and Actual Completion Date:
Actual number of days beyond the original contract:
Actual number of days added through change orders.
The recovery schedule/plan and implementation of such, if it was required. If a recovery/plan schedule was implemented, describe whether the project was successfully brought back on schedule. Please discuss, as necessary and deemed appropriate.
Name of Sub-Contractor:
Project Name:
Provide City & State of the Project location: (Note: Representative projects or contracts completed outside of the United States will NOT be accepted due to differing laws, regulations, and practices.)
Identify if the Project was performed by Sub- Contractor or if Prime Contractor Self-Performed
Utility/Owner name:
Utility/Owner Project Manager's name: and contact information to include a valid, recently verified email and telephone number:
Proposed Key Subcontractor's Key Personnel who participated on this project:
Key Personnel's role on this project:
Project completed within the last ten (10) years: Yes No
Key Sub-Contractor's Key Personnel involved in this Project were identified on the organizational chart: Yes No
Project has similar size, scope, and complexity to the work described in the Contract Documents: Yes No
-Similar Linear Footage Installed (Provide Linear Footage) Yes No
-Provide Pipe Size and footage per size (Indicate water or sewer) (Note: add more lines if necessary) LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer
-Provide Pipe Size and footage per size for BORE work (Indicate water or sewer) (Note: add more lines if necessary) LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer
LF of inch Water Sewer LF of inch Water Sewer
Detailed project description and explanation for why it is comparable to proposed Key Subcontractor's role on the Project:
Original bid/price and final construction in place costs: $ Original Bid; $ Final Construction Cost
Total number AND cost for all change orders, as well as an explanation regarding the reason for specific change orders: Total # of Change Orders $ Total Amount of COs Explain COs:
Construction Contract Notice to Proceed (NTP) Date:
Identify whether the Project was completed on-time and within budget: On time: Yes No Within budget: Yes No
Original Contract Time (specify Calendar Days or Working Days): Days (Calendar / Working)
Original Contract Completion Date and Actual Completion Date: Original Date; Actual Date
Original Contract Completion Date and Actual Completion Date:
Actual number of days beyond the original contract:
Actual number of days added through change orders.
The recovery schedule/plan and implementation of such, if it was required. If a recovery/plan schedule was implemented, describe whether the project was successfully brought back on schedule. Please discuss, as necessary and deemed appropriate.
Name of Sub-Contractor:
Project Name:
Provide City & State of the Project location: (Note: Representative projects or contracts completed outside of the United States will NOT be accepted due to differing laws, regulations, and practices.)
Identify if the Project was performed by Sub- Contractor or if Prime Contractor Self-Performed
Utility/Owner name:
Utility/Owner Project Manager's name: and contact information to include a valid, recently verified email and telephone number:
Proposed Key Subcontractor's Key Personnel who participated on this project:
Key Personnel's role on this project:
Project completed within the last ten (10) years: Yes No
Key Sub-Contractor's Key Personnel involved in this Project were identified on the organizational chart: Yes No
Project has similar size, scope, and complexity to the work described in the Contract Documents: Yes No
-Similar Linear Footage Installed (Provide Linear Footage) Yes No
-Provide Pipe Size and footage per size (Indicate water or sewer) (Note: add more lines if necessary) LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer
-Provide Pipe Size and footage per size for BORE work (Indicate water or sewer) (Note: add more lines if necessary) LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer LF of inch Water Sewer
LF of inch Water Sewer LF of inch Water Sewer
Detailed project description and explanation for why it is comparable to proposed Key Subcontractor's role on the Project:
Original bid/price and final construction in place costs: $ Original Bid; $ Final Construction Cost
Total number AND cost for all change orders, as well as an explanation regarding the reason for specific change orders: Total # of Change Orders $ Total Amount of COs Explain COs:
Construction Contract Notice to Proceed (NTP) Date:
Identify whether the Project was completed on-time and within budget: On time: Yes No Within budget: Yes No
Original Contract Time (specify Calendar Days or Working Days): Days (Calendar / Working)
Original Contract Completion Date and Actual Completion Date: Original Date; Actual Date
Original Contract Completion Date and Actual Completion Date:
Actual number of days beyond the original contract:
Actual number of days added through change orders.
The recovery schedule/plan and implementation of such, if it was required. If a recovery/plan schedule was implemented, describe whether the project was successfully brought back on schedule. Please discuss, as necessary and deemed appropriate.
Company Name(s) Total Recordable Incident Rate (TRIR) Total Recordable Incident Rate (TRIR) Total Recordable Incident Rate (TRIR)
Company Name(s) 2023 2024 2025
Prime Contractor
Company Name(s) Total Recordable Incident Rate (TRIR) Total Recordable Incident Rate (TRIR) Total Recordable Incident Rate (TRIR)
Company Name(s) 2023 2024 2025
Key Subcontractor #1
Key Subcontractor #2
Key Subcontractor #3
Key Subcontractor #4
Key Subcontractor #5
Project Name:
Utility / Owner Name:
Date of Notice to Proceed:
Original Contract Time (calendar days or working days):
Original Contract Completion Date:
Did Project encounter Unforeseen Conditions? Yes No
Describe the nature of the Unforeseen Conditions Issue
Was a Recovery Plan Required? Yes No
Was the Issue Promptly Resolved? Yes No
Was Respondent asked to Demobilize? Yes No
Was Recovery Plan Implemented? Yes No
Was the Project completed On-Time? Yes No
Actual Contract Completion Date:
This is the opportunity summary page. It provides an overview of this opportunity and a preview of the attached documentation.
Daily notification on new contract opportunities

With GovernmentContracts, you can:

  • Find more opportunities and win more business
  • Receive daily alerts for all new bid opportunities
  • Get contract opportunities matched to your business
ONE WEEK FREE TRIAL

See also

...CDBG Water Main Replacement Rebid for the Town of Littleville Littleville, Alabama August ...

Goodwyn Mills Cawood(GMC)

Bid Due: 8/13/2026

...Toutant Beauregard Rd. Water Main and Wurzbach Rd. Swing Tie Project Solicitation No. ...

San Antonio Water System

Bid Due: 8/26/2026

...DIRECTORS 41ST STREET WATER MAIN REPLACEMENT PROJECT - KENNEDY AVENUE TO 5TH STREET ...

MPN

Bid Due: 7/14/2075

...Perry County Water Authority - 2026 Heiberger Area Water Main Improvements (CR-47 & ...

Goodwyn Mills Cawood(GMC)

Bid Due: 8/20/2026

* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.