Kentucky Lock Lift Pump Station Repair/Replacement

Location: Kentucky
Posted: Dec 15, 2025
Due: Dec 29, 2025
Agency: DEPT OF DEFENSE
Type of Government: Federal
Category:
  • Y - Construction of Structures and Facilities
Solicitation No: W912P5-26-Q-KLSR
Publication URL: To access bid details, please log in.
Follow
Kentucky Lock Lift Pump Station Repair/Replacement
Active
Contract Opportunity
Notice ID
W912P5-26-Q-KLSR
Related Notice
Department/Ind. Agency
DEPT OF DEFENSE
Sub-tier
DEPT OF THE ARMY
Major Command
US ARMY CORPS OF ENGINEERS
Sub Command
ENGINEER DIVISION GREAT LAKES AND OHIO
Sub Command 2
ENDIST NASHVILLE
Office
W072 ENDIST NASHVILLE
Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information
  • Contract Opportunity Type: Sources Sought (Original)
  • Original Published Date: Dec 15, 2025 02:47 pm CST
  • Original Response Date: Dec 29, 2025 12:00 pm CST
  • Inactive Policy: 15 days after response date
  • Original Inactive Date: Jan 13, 2026
  • Initiative:
    • None
Classification
  • Original Set Aside: Total Small Business Set-Aside (FAR 19.5)
  • Product Service Code: Y1KA - CONSTRUCTION OF DAMS
  • NAICS Code:
    • 238210 - Electrical Contractors and Other Wiring Installation Contractors
  • Place of Performance:
    Grand Rivers , KY
    USA
Description

Request for Information: The Government is issuing this Request for Information to determine a competitive basis for the procurement described. This is not a solicitation. No reimbursement will be made for any costs associated with providing information in response to this survey.



This survey is for market research purposes only. Only contractors capable of performing this type of work should respond to this Request for Information.



Requirement: Contractor shall furnish all materials, supplies, tools, equipment, transportation, supervision, quality control, and labor necessary to complete this Scope of Work. All materials and workmanship will be manufactured and accomplished according to industry standards and specifications. For additional information, reference the attached document, “Lock Wall Lift Station Pump Repairs Reference Document”.




  1. Two (2) new pumps, 40 GPM and 108 feet TDH, 5.0 HP, 3450 RPM, 460/3/60 Hz will be procured and installed within the Lock Wall lift station. The existing pump supports within the lift station are damaged and new pump supports will need to be installed. The contractor shall also verify if the Conery base can be reused without modification. If not, the contractor will be responsible for replacing the base. Costs estimated for this work shall include any pumping/removal of existing waste in the lift station that is required to complete this task safely. Reference the provided reference document for additional details related to existing utilities associated with the lift station.

  2. The existing lift station contains two (2) grinder pumps. One of the existing pumps has been removed and replaced. The removed pump shall be repaired to full functionality. The removed pump is a Zoeller Model G7112, 7.5 HP, 3450 RPM, 460/3/60 Hz, submersible high head grinder pump complete with 2 ½ inch horizontal discharge flange that is adaptable to 3-inch, SC/SC lower seal, 7.125-inch diameter impeller complete with 25-feet power & control cable.

  3. The contractor shall repair or replace the transducer associated with the lift station pump. The currently installed transducer is precision digital PDA6420 Split Core AC Current Transducer.

  4. The contractor shall replace “in-kind” the 2” check valve inside the wet well. The existing check valve is Flomatic Check Valves Model 508 Part Number 3235.

  5. The contractor shall replace “in-kind” the 2” ball valve inside the wet well. The existing ball valve is Flomatic Ball Valves Part Number SSBV1000-20. Verify operation of the new ball valve with the extension handle.

  6. The Contractor shall perform a functionality test to ensure the system works as intended. Test procedures describing the functionality test shall be submitted to the Government for review and approval. The following functions shall be tested to verify that they are functioning as intended by design:

    • Both pumps automatically run via the transducer system.

    • Both pumps automatically run via the float system.

    • The pumps automatically switch from the transducer system to the float system if the transducer system fails.





Period of Performance: The Period of Performance shall be performed within 30 calendar days of the award date.



Place of Performance:



Kentucky Lock Resident Office



193 Taylor Park Rd.



Grand Rivers, KY 42045



NAICS: The anticipated NAICS code for this requirement is 238210 (Electrical Contractors and Other Wiring Installation Contractors) with a size standard of $19,000,000.



Survey: Please send responses to the Market Survey to Samantha Clay at Samantha.J.Clay@usace.army.mil and Cierra Vega at Cierra.R.Vega@usace.army.mil by 12:00PM CT on December 29, 2025.




  1. Name of Firm:

  2. CAGE:

  3. Point of Contact (include email address)

  4. Are you classified as a small business under any of the following NAICS code:




  • 238210 (Electrical Contractors and Other Wiring Installation Contractors)



5. If this requirement is advertised, do you anticipate submitting a quote?



6. List three (3) projects completed within ten (10) years of the date of this notice that demonstrates experience with electrical and wiring installation:




  • Project Name / General Description:



Contract Number (if applicable):



Dollar Amount:




  • Project Name / General Description:



Contract Number (if applicable):



Dollar Amount:




  • Project Name / General Description:



Contract Number (if applicable):



Dollar Amount:


Attachments/Links
Contact Information
Contracting Office Address
  • KO CONTRACTING DIVISION 801 BROADWAY RM A604
  • NASHVILLE , TN 37203-1070
  • USA
Primary Point of Contact
Secondary Point of Contact
History
  • Dec 15, 2025 02:47 pm CSTSources Sought (Original)
Daily notification on new contract opportunities

With GovernmentContracts, you can:

  • Find more opportunities and win more business
  • Receive daily alerts for all new bid opportunities
  • Get contract opportunities matched to your business
ONE WEEK FREE TRIAL
* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.