Precast Concrete Manholes

Location: Texas
Posted: Jul 6, 2026
Due: Jul 28, 2026
Agency: City of Austin
Type of Government: State & Local
Category:
  • 54 - Prefabricated Structures and Scaffolding
Solicitation No: IFB 1100 AGM1007
Publication URL: To access bid details, please log in.

Solicitation Details
eResponse Instructions Subscribe Print PDF
Type:
Invitation For Bids (IFB)

Status: Open
Solicitation Number: IFB 1100 AGM1007
Description: Precast Concrete Manholes
Summary: The City of Austin Electric Utility, dba Austin Energy, requires a qualified Contractor to supply precast concrete manholes. They will be used by Austin Energy (AE) for the underground transmission, distribution, and communication systems.
Basic Information
Contact Information
Authorized Contact Names:
Solicitation Specific
Questions:

Ahide Garcia-Martinez

(512) 9742803

ahide.garcia@austintexas.gov
Small Minority Business
Resources Questions:


SMBR Main Office

(512) 974-7600

SMBRComplianceDocuments@austintexas.gov
Dates & Times
Important Solicitation Dates:

Solicitation Published:
07/06/2026 07:20 AM

Response Due:

Prior to 07/28/2026, 02:00 PM

Response Opening:

07/28/2026, 03:00 PM
Special Notes
Special Notes:
None Available

Attachments
Packet Download Files

Click on the Download All Files button below to download a folder which includes all files.
Click on the individual Download buttons below to download an individual file.
Downloading solicitation documents will not automatically subscribe you to this solicitation. If you would like to receive future updates for this solicitation please subscribe to the solicitation by clicking the Subscribe button at the top of this screen.

Download All Files


Commodities
Associated Commodities
Description Code
MANHOLES, PRECAST, TYPE A 8903053
Trade Summary
Description Category Code
Manholes, Precast, Type A Goods 8903053

Attachment Preview

CITY OF AUSTIN

SCOPE OF WORK

PRECAST CONCRETE MANHOLES

SOLICITATION NO. IFB 1100 AGM1007

Purpose

The City of Austin Electric Utility, dba Austin Energy, requires a qualified Contractor to supply precast concrete manholes. The precast concrete manholes shall be engineered and fabricated to provide a structurally safe design.

The precast concrete manholes will be used by Austin Energy (AE) for the underground transmission, distribution, and communication systems.

Term of Contract

This Contract shall remain in effect for an initial term of twenty-four (24) months or the City terminates the Contract. This Contract may be extended beyond the initial term for up to three (3) additional twelve (12) month periods at the City's sole option.

Contractor's Requirements

The Contractor shall:

Supply all vehicles, equipment and accessories required to deliver, safely lift and place the manhole in the excavation for the manhole at the Austin Energy job site.

Present Austin Energy with the engineering data for the manholes, stamped/certified by a registered professional engineer prior to any manufacturing. The certified engineering data shall state the structural integrity for the manhole configurations listed in Attachment A.

Single Point of Contact

Provide a single point of contact (SPOC) who is skilled, knowledgeable, and experienced in providing and handling precast concrete manholes. The SPOC must comply with all SOW requirements.

Provide the SPOC's office number, email address, and after hours phone number to the Contract Manager, within five (5) days after contract award.

During times the SPOC is unavailable (due to vacation, travel, etc., for example), provide a designee for the SPOC to the Contract Manager. The designee shall meet the same requirements as specified for the SPOC and shall have the same authority as the SPOC.

City's Responsibilities

The City will:

Provide a point of contact to the awarded Contractor.

Provide a Delivery Order (DOM) for each order. No work shall be performed without a reference DOM.

Delivery Requirements and Locations

The Contractor shall:

Ensure delivery is made within seven (7) calendar days after the order is placed (either verbally or in writing). All orders must be shipped complete unless arrangements for partial shipments are made in advance.

Confirm the quantity to be shipped on all orders within two (2) hours of notification by phone from the City.

Delivery to locations that will vary and will be issued by Austin Energy with each order.

Provide, with each delivery, a shipping or delivery ticket showing the description of each item, quantity, and unit price.

In accordance with Specification E-0897, deliver and place the requested manhole(s) in the excavation designated for the manhole at the AE job site, and shall coordinate the date and time of placement with the order requestor.

Not make deliveries on City-recognized legal holidays, unless otherwise requested by the City.

Specific Invoice Requirements

The City's preference is to have invoices emailed to Santiago.Reyes@austinenergy.com

For questions regarding your invoice/payment please contact the City Contract Manager.

At a minimum, invoices shall be itemized and contain the following information, or they will not be processed and will be returned to the Contractor for correction:

A unique invoice number

Invoice date

Purchase order or delivery order number

Description of the goods or services provided

The Contractor's name and remit to address

Any discounts or markups, if applicable.

Applicable Standards

The Manholes shall conform to or exceed applicable requirements of the following standards and codes:

ASTM A-615 Grade 60 for Rebar

ASTM A-185 Grade 65 for Mesh

ASTM C-857 Minimum Structural Design Loading for Underground Precast Concrete Utility Structures

AASHTO HS 20 Loading

ACI 318 for Structural Concrete

ASTM C150 for Portland Cement

ASTM C478 for Standard Specification for Precast Reinforced Concrete Manhole Sections

ASTM C858 Standard Specification for Underground Precast Concrete Utility Structures ASTM C478 for standard

Design Loads

The precast concrete manholes (Attachment I) shall be:

Rated for AASHTO HS-20 loading. Traffic (live load = 16,000lbs) shall approach the structure from any direction.

Designed to be installed with the top of the vault to have a burial depth 3 feet or 5 feet below grade, whichever is specified.

Designed for a burial depth of 3 feet; and provided with access openings that are 36 inches in diameter.

Designed for a burial depth of 5 feet; and provided with access openings that are 48 inches in diameter.

Physical Requirements

The Contractor shall fabricate precast concrete manholes in accordance with Attachment I.

The precast concrete manhole windows shall be a non-reinforced concrete membrane. The dimensions of the windows and thickness of the non-reinforced concrete membrane shall be as shown on the attached drawings (Attachment I).

Minimum compressive strength of concrete shall not be less than 4,000 psi in 28 days.

The concrete cover for reinforcement shall be provided as shown in the attached drawings (Attachment I). If not noted on drawings, the concrete cover for reinforcement shall be 1.5 inches minimum for main reinforcing bars and 34 inch for stirrups and ties.

The concrete finish shall be free of rock pockets and honeycombed areas.

The interior walls, ceiling and exterior surfaces exposed shall be smooth.

Knockout and duct openings shall be beveled on the exterior surface.

Inserts shall be provided as shown in the attached drawings (Attachment I).

No protective coating or liner is required on manholes used by Austin Energy.

Designation of Key Personnel

The City and the Contractor resolve to keep the same key personnel assigned to this engagement throughout its term. In the event that it becomes necessary for the Contractor to replace any key personnel, the replacement will be an individual having equivalent experience and competence in executing projects such as the one described herein. Additionally, the Contractor shall promptly notify the City and obtain approval for the replacement. Such approval shall not be unreasonably withheld. The Contractor's and City's key personnel are identified as follows:

Name/ Title Phone Number Email Address
City Contract Manager Patrick Rogers 512-480-3043 Patrick.Rogers@austinenergy.com
City Contract Administrator, Procurement Specialist Lorena McBee 512-978-0873 Lorena.McBee@austintexas.gov
This is the opportunity summary page. It provides an overview of this opportunity and a preview of the attached documentation.
Daily notification on new contract opportunities

With GovernmentContracts, you can:

  • Find more opportunities and win more business
  • Receive daily alerts for all new bid opportunities
  • Get contract opportunities matched to your business
ONE WEEK FREE TRIAL

See also

Bid Information Type Invitation For Bid Status Issued Number IFB 2026-073 (Cold Laid

City of Laredo

Bid Due: 8/07/2026

Title Start Date End Date Time Left Addendums RFB #26-018 - TDEM GRANT

City of North Richland Hills

Bid Due: 8/20/2026

Project: RFP - Esoteric Testing Services Ref. #: 26/0129 Type: RFP Status: Open

Harris County

Bid Due: 8/10/2026

Project: CSP -Radiation Oncology Suite Renovation and LINAC Replacement at Smith Clinic for

Harris County

Bid Due: 8/31/2026

* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.