FILTER MEDIA REPLACEMENT CHARLES B. BACON W/S TREATMENT PLANT
|
| Category: | Construction Projects |
| Status: | Open |
|
| PROJECT LOCATION W N M I D D L E T O M I D D L E F I E L D M M I D I D D D L E L E T F O I W E N L D |
|---|
CITY OF MIDDLETOWN, CONNECTICUT
CHARLES B. BACON WATER TREATMENT PLANT -
FILTER REHABILITATION PROJECT
MOUNT HIGBY RESERVOIR, 260 MERIDEN ROAD, MIDDLETOWN, CONNECTICUT
BID NO. 2026-013
PREPARED FOR
CITY OF MIDDLETOWN, CONNECTICUT
SHEET TITLE
WATER AND SEWER DEPARTMENT
82 BERLIN STREET
MIDDLETOWN, CT - COVER SHEET
SP-1 SITE PLAN & TRUCK ROUTE
PROJECT LOCATION
SP-1 SITE BUILDING PLAN
EP-1 FILTER ROOM PLAN
EP-2 FILTER SECTIONS AND DETAILS
EP-3 TYPICAL FILTER CELL DETAIL
M I D D L E T O W N D-1 DETAILS 1 - BACKWASH ASSEMBLY
M I D D L E F I E L D D-2 DETAILS 2 - CARRIAGE ASSEMBLY
M
M I
D
I
D D
D L
E
L
E T
F O
I W
E
N
L
D
1500 750 0 1500 3000 FEET
C E I N B C
*
OMPREHENSIVE NVIRONMENTAL NCORPORATED EW RITIAN, ONNECTICUT
AUGUST 2026
CONTRACTOR'S
ACCESS DOORWAY TO
GENERAL NOTES
FILTER MEDIA ROOM
CONTRACTOR'S
TRUCK ROUTE
SITE PLAN
SITE ACCESS ROAD & TRUCK ROUTE
TO / FROM MERIDEN
ROAD (ROUTE 66)
NOTE:
SITE PLAN & TRUCK ROUTE
THE "SITE PLAN AND TRUCK ROUTE" PLAN IS BASED ON PROJECT FILE PLAN SP-1
PROVIDED BY THE CITY OF MIDDLETOWN, CONNECTICUT, PLAN TITLED
"HIGBY RESERVOIR SOLAR PANEL CONDUITS" SCALE: 1"=40', DRAWN BY
BR/JE, DATED 1/2018.
20 10 0 20 40
Scale 1" = 20'
GENERAL NOTES
CONTRACTOR'S
ACCESS DOORWAY TO
FILTER MEDIA ROOM
FILTER
MEDIA
ROOM
NO VEHICLE ACCESS
OVER CLEAR WELL
SITE BUILDING
NOTE:
SP-2
THE "SITE BUILDING" PLAN IS BASED ON AS-BUILTS PROVIDED BY THE CITY
EXISTING SITE BUILDING PLAN
OF MIDDLETOWN, CONNECTICUT WATER & SEWER DEPARTMENT, WATER
FILTRATION PLANT AT MT. HIGBY RESERVOIR, SHEET NO. 4 OF 68, DWG NO.
G-4, PLAN TITLED "GENERAL SITE PLAN", PREPARED BY NATHAN L.
JACOBSON & ASSOCIATES, DENLAR DRIVE, CHESTER, CONNECTICUT, 20 10 0 20 40
CONTRACT NO. 2, DATED DEC, 1979, LAST REVISION: 3/25/80.
Scale 1" = 20'
PREP & REPAINT TRAVELING CARRIAGE
GENERAL NOTES
ASSEMBLY BASE BEAMS WITH TNEMEC
HYDROLINE SERIES 1220 EXPOXY COATING
OR APPROVED EQUAL (TYP. OF 2)
Manually Controlled
Valve Operator
(Typical)
Aluminum
Door to Aluminum Hatch
High Service Hatch
Pump Room
Metaphosphate Chemical Line
Aluminum
Sodium Hydroxide Chemical Line Hatch
Chlorine Chemical Line
Aluminum
Hatch
Valve
Operator
Aluminum
Hatch
Aluminum
Hatch
REMOVE EXISTING ANTHRACITE &
NEW 4" DIA. FLOW SAND FILTER MEDIA AS PER
METER, GLOBE VALVE SPECIFICATIONS
& ASSOCIATED PIPING (TYPICAL ALL CELLS - EACH FILTER)
(SEE SHEET D-2)
Aluminum
Hatch
RE-CAULK AS
NEEDED (POST
REMOVAL - TYP.)
Aluminum
Hatch
CONTRACTOR'S
ACCESS DOORWAY TO
Aluminum
FILTER MEDIA ROOM
Hatch
Aluminum
Hatch
INSTALL NEW POROUS MODIFICATIONS TO
PLATES AND CAULK (TYP.) EXISTING FILTERS
FILTER ROOM PLAN
NOTE: EXISTING FILTER ROOM PLAN
EP-1
THE "MODIFICATIONS TO EXISTING FILTERS FILTER ROOM PLAN" IS BASED
ON AS-BUILTS PROVIDED BY THE CITY OF MIDDLETOWN, CONNECTICUT,
SHEET EP-1 PLAN TITLED "CHARLES BACON WATER TREATMENT PLAN
MODIFICATIONS TO EXISTING FILTERS PLAN SHOWING FILTER ROOM", 3 0 3 6
PREPARED BY MAGUIRE GROUP INC., ONE COURT STREET, NEW BRITAIN,
CONNECTICUT 06051, MGI NO.: 11836, DATED MAY 1, 1991. Scale 1" = 3'
GENERAL NOTES
PLACE NEW MEDIA:
(SEE SPECIFICATIONS)
22" GAC
10" SILICA SAND
PREP & REPAINT TRAVELING
CARRIAGE ASSEMBLY BASE
BEAMS WITH TNEMEC HYDROLINE
SERIES 1220 EXPOXY COATING
OR APPROVED EQUAL (TYP. OF 2)
INSTALL NEW 4" FLOW METERS ON
EXISTING FILTER BED NO.1 & NO.2
CARRIAGE ASSEMBLIES
(SEE SHEET D-2 FOR DETAIL VIEW)
MODIFICATIONS TO
EXISTING FILTERS
SECTIONS AND DETAILS
RE-CAULK JOINTS & REPLACE
POROUS PLATES (AS REQUIRED)
NOTE: EP-2
EXISTING FILTERS SECTION AND DETAILS PLAN
THE "MODIFICATIONS TO EXISTING FILTERS TYPICAL SECTION AND DETAILS"
PLAN IS BASED ON AS-BUILTS PROVIDED BY THE CITY OF MIDDLETOWN,
CONNECTICUT, SHEET EP-2, PLAN TITLED "CHARLES BACON WATER
TREATMENT PLAN MODIFICATIONS TO EXISTING FILTERS SECTIONS AND
2 0 2 4
DETAILS", PREPARED BY MAGUIRE GROUP INC., ONE COURT STREET, NEW
BRITAIN, CONNECTICUT 06051, MGI NO.: 11836, DATED MAY 1, 1991. Scale 1" = 2'
GENERAL NOTES
MODIFICATIONS TO
EXISTING FILTERS
TYPICAL FILTER CELL DETAIL
NOTE:
EP-3
THE "MODIFICATIONS TO EXISTING FILTERS TYPICAL FILTER CELL DETAIL"
PLAN IS BASED ON AS-BUILTS PROVIDED BY THE CITY OF MIDDLETOWN,
TYPICAL FILTER CELL DETAIL
CONNECTICUT, SHEET EP-3, PLAN TITLED "CHARLES BACON WATER
TREATMENT PLAN MODIFICATIONS TO EXISTING FILTERS TYPICAL FILTER
CELL DETAIL", PREPARED BY MAGUIRE GROUP INC., ONE COURT STREET,
NEW BRITAIN, CONNECTICUT 06051, MGI NO.: 11836, DATED MAY 1, 1991.
CAG
INSTALL NEW ALUMINUM
OXIDE POROUS PLATE
UNDERDRAIN SYSTEM
PROVIDE NEW POLYURETHANE
SEALANT: 5/8" BEAD AS-NEEDED
(TYPICAL TOP)
EMBEDDED FIBERGLASS CELL SHEET
REMOVE, CLEAN AND REPLACE
SHEETS AS REQUIRED.
*
*
* DETAILS PROVIDED TO SHOW CELL CONNECTION OF
POROUS PLATES AND CAULKING.
NOT TO SCALE
"3
"22
"01
"2
"42
"42
"9
"1
NOT TO SCALE
NOT TO SCALE
GENERAL NOTES
FILTER RETROFIT BACKWASH ASS'Y
ELEVATION VIEW
NOT TO SCALE
BACKWASH SHOE PLAN
NOT TO SCALE
FILTER RETROFIT BACKWASH ASS'Y
PLAN VIEW
NOT TO SCALE
MODIFICATIONS TO
EXISTING FILTERS
DETAILS 1 -
BACKWASH ASSEMBLY
D-1
NOTE:
THE "MODIFICATIONS TO EXISTING FILTERS DETAIL 1" PLAN IS BASED ON
AS-BUILTS PROVIDED BY THE CITY OF MIDDLETOWN, CONNECTICUT, SHEET
1 of 1, PLAN TITLED "FILTER RETROFIT BACKWASH ASS'Y." PREPARED BY
AQUA-AEROBIC SYSTEMS, INC. PART NO. 93389005, DATED 6-12-89.
WOLF
FLOW
FLOW
BACKWASH
DISCHARGE
PIPING
(SEE SHEETS
EP-2 & EP-3)
F
BACKWASH
L
O
DISCHARGE
W
PIPING
(SEE SHEETS
EP-2 & EP-3)
| FLOW | ||||||||||
| FL | OW | |||||||||
PREP & REPAINT TRAVELING NEW 4" DIA. ASTM PROVIDE FITTINGS & CONNECTIONS AS
CARRIAGE ASSEMBLY BASE D1785 SCH. 40 PVC NECESSARY TO MAKE CONNECTIONS. GENERAL NOTES
BEAMS WITH TNEMEC HYDROLINE PIPING & ASSOCATIED
SERIES 1220 EXPOXY COATING BENDS / FITTINGS
OR APPROVED EQUAL (TYP. OF 2)
FLOW
NEW 4" DIA.
GLOBE VALVE
FLOW
NEW 4" DIA.
MAGNETIC
INSTALL SUPPORT
FLOW METER
BRACKETS (TYP OF 3)
& BOLT TO CARRIAGE
ASSEMBLY BEAM
(SEE DETAIL "A" )
CARRIAGE ASSEMBLY DETAILS
1 0 1 2
Scale 1" = 1'
INSTALL PIPE CLAMPS
AS NECESSARY (TYP.)
EXISTING RAILING
BOLT TO NEW
BRACKET ASSEMBLY
EXISTING CARRIAGE
NEW 4" DIA. ASTM
ASSEMBLY
D1785 SCH. 40 PVC
PIPING (TYP.)
INSTALL NEW "L" BRACKETS (2" W X 2' L)
EXISTING CARRIAGE STAINLESS STEEL OR PAINTED STEEL - MODIFICATIONS TO
EXISTING FILTERS
ASSEMBLY I-BEAM SAME AS CARRIAGE ASSEMBLY I-BEAM.
DETAILS 2 -
CARRIAGE ASSEMBLY
INSTALL NEW
INSTALL STAINLESS
CHANNEL BRACKETS
STEEL BOLTS (TYP.)
(2" W X 4" H)
WELD TO FLANGE
NOTE: BRACKETS & SUPPORTS SHOWN FOR
NOTE: ILLUSTRATIVE PURPOSES. DESIGN OF BRACKETS,
DETAIL "A"
D-2
THE "MODIFICATIONS TO EXISTING FILTERS TYPICAL SECTION AND DETAILS"
SUPPORTS, CLAMPS & HARDWARE SHALL BE THE
PLAN IS BASED ON AS-BUILTS PROVIDED BY THE CITY OF MIDDLETOWN, NTS
CONNECTICUT, SHEET EP-2, PLAN TITLED "CHARLES BACON WATER
RESPONSIBILITY OF THE CONTRACTOR.
TREATMENT PLAN MODIFICATIONS TO EXISTING FILTERS SECTIONS AND
DETAILS", PREPARED BY MAGUIRE GROUP INC., ONE COURT STREET, NEW
BRITAIN, CONNECTICUT 06051, MGI NO.: 11836, DATED MAY 1, 1991.

With GovernmentContracts, you can:
...IPSWICH WATER TREATMENT PLANT, DWSRF 19229 Location: 274 High St. - Ipswich, Massachusetts ...
O'Connell Companies
Bid Due: 10/26/2026
...Project: Boiler Replacement at Waste Water Treatment Plant (WWTP) Ref. #: 26-3 Type: ...
Town of Beacon Falls
Bid Due: 10/19/2026
...Project: Boiler Replacement at Waste Water Treatment Plant (WWTP) Ref. #: 26-3 Type: ...
Town of Beacon Falls
Bid Due: 10/19/2026
...Boiler Replacement at Waste Water Treatment Plant (WWTP) (Notice Only) Beacon Falls is ...
State Government of Connecticut
Bid Due: 10/19/2026