| Solicitation Name: | Lift Station Pump - Mohican State Park |
| Original Begin Date: | 5/8/2025 12:00:00 AM |
| Begin Date: | 5/8/2025 12:00:00 AM |
| End Date: | 5/22/2025 10:00:00 AM |
| Inquiry End Date: | 5/20/2025 12:00:00 AM |
| Commodity: | Sewage pumps |
| MBE Set Aside: | MBE Set Aside |
| Agency: | DNR353116 Mohican State Park DNRASH |
| Solicitation Status: | Open for Bidding |
| Solicitation Type: | Quick Quote |
|
In an MBE set-aside solicitation, only those bidders/suppliers with an active MBE certification at the time the solicitation closes can submit a response
|
|||
|
Solicitation ID
SRC0000030703
|
|||
|
Solicitation Name
Lift Station Pump - Mohican State Park
|
RFx Type
Quick Quote
|
||
|
Lot #
1
|
Solicitation Status
Open for Bidding
|
||
|
Round #
1
|
MBE Set Aside
|
||
|
Begin Date
5/8/2025 12:00:00 AM (ET)
|
Amendment?
|
||
|
End Date
5/22/2025 10:00:00 AM (ET)
|
Inquiry End Date
5/20/2025 12:00:00 AM
|
||
|
Summary
Needed Supply: Lift Station Pump
Electrical Power Cord: The power cord will be SOOW or W, oil and water resistant 600v, 90C, UL® and CSA® approved and applied per NEC ampacities ratings at the cables rated temperature for intermittent / continuous duty. The pump shall be double protected with a compression fitting and an epoxy potted area that seals each conductor at the power cord entry to the pump. The power cable entry into the cord cap assembly shall first be made with a compression fitting. The leads shall be terminated within the epoxy and mechanically crimped to Teflon leads. This area of the cord cap shall then be filled with an epoxy compound potting. This assembly will prevent water contamination from gaining entry even in the event of wicking or capillary action. The power cord leads shall be connected to the motor leads with a terminal block or extra heavy connectors. The cord cap assembly where bolted to the motor housing shall be sealed with a Nitrile O-ring on a beveled edge to assure proper sealing. Wiring connection shall be done through a terminal block eliminating wire nuts or use of heavy duty crimp connectors. MOTOR: With exception of 208V models, motors shall meet premium efficiency in accordance with IEC 60034-30, level IE3, and NEMA MG1 [NEMA 12.60 Enclosed motor]. The motors are submerged in non-toxic, oil filled, cool running design providing significantly reduced operating temperatures. Pump designs requiring a secondary cooling apparatus shall be deemed unapproved and not equal. Air filled pump designs shall not be considered equal or approved.
|
|||
|
Process
Evaluation. The contract will be awarded to the lowest responsive and responsible bidder as determined by the State. |
|||
|