Upgrade the HVAC System at Frank Long Elementary School RFP 2026-06 Addendum 1

Location: Georgia
Posted: Dec 11, 2025
Due: Jan 6, 2026
Agency: Liberty County School System
Type of Government: State & Local
Category:
  • Y - Construction of Structures and Facilities
  • Z - Maintenance, Repair or Alteration of Real Property
Publication URL: To access bid details, please log in.
Upgrade the HVAC System at Frank Long Elementary School RFP 2026-06
Title:
Upgrade the HVAC System at Frank Long Elementary School RFP 2026-06
Description:
The Liberty County School System (the “LCSS” or the “District”) wishes to announce that we are requesting Statements of Proposals to Upgrade the HVAC System at Frank Long Elementary School RFP 2026-06, by a firm authorized to do business in the State of Georgia. The advertising dates for this RFP 2026-06 are November 24, 2025 through January 6, 2026. Statements of Proposals will be accepted prior to 11:00 A.M. on January 6, 2026. A mandatory Pre-Proposal
Conference will be held on December 3, 2025 at 11:00 A.M., at Frank Long Elementary School in the Media Center, located at 920 Long Frasier Drive, Hinesville, Georgia 31313.
Start Date:

11/24/2025
Contact Name:
Arnold
Contact Phone:
Jackson
Contact Email:
Contact Address:

200 Bradwell St
Contact City:

Hinesville
Contact State:

Ga
Contact Zip:

31313
Files:

Attachment Preview

FLE HVAC Upgrades
RFP 2026-06
RFP ADDENDUM #1
Page 1 of 1
RFP ADDENDUM #1
Date of Addendum: December 10, 2025
NOTICE TO ALL POTENTIAL RESPONDENTS
The Request for Proposals (RFP) is modified as set forth in this Addendum. The original RFP Documents
and any previously issued addenda remain in full force and effect, except as modified by this Addendum,
which is hereby made part of the RFP. Respondent shall take this Addendum into consideration when
preparing and submitting its Proposal.
PROPOSAL SUBMITTAL DEADLINE
The Proposal submittal deadline remains the same and is not changed by this
Addendum.
QUESTIONS AND ANSWERS
1. Question: PTAC units will not be replaced at this time. How does this affect the
bipolar ionization device and ventilation rates?
a. Bipolar isolation devices will not be provided for each classroom. This will
be done in the future replacement of PTAC units.
2. Question: Shall the contractor be responsible for providing restrooms for
construction personnel?
a. Temporary restroom facilities (portable toilets) for construction personnel
shall be provided, maintained, and removed by the contractor. Locations
shall be coordinated with owner prior to project start. Owner-furnished of
existing restrooms shall not be used unless specifically approved in writing.
3. Question: Existing roof hatch is installed backwards. Will this be addressed in new
work?
a. Roof hatch shall be rotated to open away from the access ladder.
4. The Pre-bid Sign-in sheet is attached to this addendum.
END OF ADDENDUM
ELECTRICAL ABBREVIATIONS LIST
1P
1 POLE (2P, 3P, 4P, ETC.)
A, AMP AMPERE
AC
ABOVE COUNTER
ACLG ABOVE CEILING
ADO AUTOMATIC DOOR OPENER
AF
AMP FRAME
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFI ARC FAULT CIRCUIT
INTERRUPTER
AHU AIR HANDLING UNIT
AL
ALUMINUM
ALT ALTERNATE
AMP AMPERE
AMPL AMPLIFIER
ANNUN ANNUNCIATOR
APPROX APPROXIMATELY
AQ-STAT AQUASTAT
ARCH ARCHITECT, ARCHITECTURAL
AS
AMP SWITCH
AT
AMP TRIP
ATS AUTOMATIC TRANSFER SWITCH
AUTO AUTOMATIC
AUX AUXILIARY
AV
AUDIO VISUAL
AWG AMERICAN WIRE GAUGE
BATT BATTERY
BD
BOARD
BLDG BUILDING
BMS BUILDING MANAGEMENT SYSTEM
C
CONDUIT
CAB CABINET
CAT CATALOG
CATV CABLE TELEVISION
CB
CIRCUIT BREAKER
CCTV CLOSED CIRCUIT TELEVISION
CKT CIRCUIT
CLG CEILING
COMB COMBINATION
CMPR COMPRESSOR
CONN CONNECTION
CONST CONSTRUCTION
CONT CONTINUATION OR CONTINUOUS
CONTR CONTRACTOR
CONV CONVECTOR
CP
CIRCULATING PUMP
CRT CATHODE-RAY TUBE
CT
CURRENT TRANSFORMER
CTR CENTER
CU
COPPER
DCP DOMESTIC WATER CIRCULATING PUMP
DEPT DEPARTMENT
DET DETAIL
DIA DIAMETER
DISC DISCONNECT
DIST DISTRIBUTION
DN
DOWN
DPR DAMPER
DS
SAFETY DISCONNECT SWITCH
DT
DOUBLE THROW
DWG DRAWING
EC
ELECTRICAL CONTRACTOR
ELEC ELECTRIC, ELECTRICAL
ELEV ELEVATOR
ELU EMERGENCY LIGHTING UNIT
EM EMERGENCY
EMS ENERGY MANAGEMENT SYSTEM
EMT ELECTRICAL METALLIC TUBING
EP
ELECTRIC PNEUMATIC
EQUIP EQUIPMENT
EWC ELECTRIC WATER COOLER
EXIST EXISTING
EXH EXHAUST
EXP EXPLOSION PROOF
FA
FIRE ALARM
FABP FIRE ALARM BOOSTER POWER
SUPPLY PANEL
FACP FIRE ALARM CONTROL PANEL
FCU FAN COIL UNIT
FIXT FIXTURE
FLR FLOOR
FLUOR FLUORESCENT
FU
FUSE
FUDS FUSED SAFETY DISCONNECT SWITCH
GA GAUGE
GAL GALLON
GALV GALVANIZED
GC GENERAL CONTRACTOR
GEN GENERATOR
GFI GROUND FAULT CIRCUIT INTERRUPTER
GFP GROUND FAULT PROTECTOR
GND GROUND
GRS GALVANIZED RIGID STEEL (CONDUIT)
GYP BD GYPSUM BOARD
HOA HANDS-OFF-AUTOMATIC SWITCH
HORIZ HORIZONTAL
HP
HORSEPOWER
HPF HIGH POWER FACTOR
HT
HEIGHT
HTG HEATING
HTR HEATER
HV
HIGH VOLTAGE
HVAC HEATING, VENTILATING AND AIR
CONDITIONING
IC
INTERRUPTING CAPACITY
IG
ISOLATED GROUND
IMC INTERMEDIATE METAL CONDUIT
INCAND INCANDESCENT
IR
INFRARED
I/W INTERLOCK WITH
J-BOX JUNCTION BOX
KV
KILOVOLT
KVA KILOVOLT-AMPERE
KVAR KILOVOLT-AMPERE REACTIVE
KW KILOWATT
KWH KILOWATT HOUR
LOC LOCATE OR LOCATION
LT
LIGHT
LTG LIGHTING
LTNG LIGHTNING
LV
LOW VOLTAGE
MAX MAXIMUM
MAG.S MAGNETIC STARTER
M/C MOMENTARY CONTACT
MC MECHANICAL CONTRACTOR
MCB MAIN CIRCUIT BREAKER
MCC MOTOR CONTROL CENTER
MDC MAIN DISTRIBUTION CENTER
MDP MAIN DISTRIBUTION PANEL
MFR MANUFACTURER
MFS MAIN FUSED DISCONNECT SW
MH MANHOLE
MIC MICROPHONE
MIN MINIMUM
MISC MISCELLANEOUS
MLO MAIN LUGS ONLY
MMS MANUAL MOTOR STARTER
MOA MULTIOUTLET ASSEMBLY
MSP MOTOR STARTER PANELBOARD
MSBD MAIN SWITCHBOARD
MT MOUNT
MT.C EMPTY CONDUIT
MTS MANUAL TRANSFER SWITCH
MTR MOTOR, MOTORIZED
N.C. NORMALLY CLOSED
NEC NATIONAL ELECTRICAL CODE
NEMA NATIONAL ELECTRICAL
MANUFACTURER'S ASSOCIATION
NFDS NON-FUSED SAFETY DISCONNECT
SWITCH
NIC NOT IN CONTRACT
NL
NIGHT LIGHT
N.O. NORMALLY OPEN
NPF NORMAL POWER FACTOR
NTS NOT TO SCALE
OH OVERHEAD
OL
OVERLOADS
PA
PUBLIC ADDRESS
PB
PULL BOX OR PUSHBUTTON
PE
PNEUMATIC ELECTRIC
PED PEDESTAL
PF
POWER FACTOR
PH
PHASE
PIV POST INDICATING VALVE
PNL PANEL
PP
POWER POLE
PR
PAIR
PRI PRIMARY
PROJ PROJECTION
PRV POWER ROOF VENTILATOR
PT
POTENTIAL TRANSFORMER
PVC POLYVINYL CHLORIDE (CONDUIT)
PWR POWER
QUAN QUANTITY
RCPT RECEPTACLE
REQD REQUIRED
RM ROOM
RSC RIGID STEEL CONDUIT
RTU ROOF TOP UNIT
SABC SMALL APPLICANCE BRANCH
CIRCUIT
SC
SURFACE CONDUIT
SEC SECONDARY
SHT SHEET
SIM SIMILAR
S/N SOLID NEUTRAL
SPEC SPECIFICATION
SPKR SPEAKER
SP
SPARE
SPD SURGE PROTECTION DEVICE
SR
SURFACE RACEWAY
SS
STAINLESS STEEL
SSW SELECTOR SWITCH
S/S STOP/START PUSHBUTTONS
STA STATION
STD STANDARD
SURF SURFACE MOUNTED
SW SWITCH
SWBD SWITCHBOARD
SYM SYMMETRICAL
SYS SYSTEM
TEL TELEPHONE
TEL/DATA TELEPHONE/DATA
TERM TERMINAL
TL
TWIST LOCK
TR
TAMPER RESISTANT
T-STAT THERMOSTAT
TTC TELEPHONE TERMINAL CABINET
TV
TELEVISION
TVTC TELEVISION TERMINAL CABINET
TYP TYPICAL
UC UNDER COUNTER
UE
UNDERGROUND ELECTRICAL
UG UNDERGROUND
UH UNIT HEATER
UNO UNLESS NOTED OTHERWISE
UT
UNDERGROUND TELEPHONE
UTIL UTILITY
UV
ULTRAVIOLET
V
VOLT
VA
VOLT-AMPERES
VDT VIDEO DISPLAY TERMINAL
VERT VERTICAL
VFD VARIABLE FREQUENCY DRIVE
VOL VOLUME
W
WATT
W/
WITH
WG WIRE GUARD
WH WATER HEATER
W/O WITHOUT
WP WEATHERPROOF
XFMR TRANSFORMER
XFR TRANSFER
ANGLE
@ AT
▲ DELTA
' FEET
" INCHES
# NUMBER
Ø PHASE
C CENTER LINE
P PLATE
ELECTRICAL SYMBOL LEGEND
LIGHTING SYMBOLS
POWER SYMBOLS
TELECOM SYMBOLS
LIGHTING FIXTURES, TYPICAL, RECTANGULAR
(VARIOUS SYMBOLS)
FILLED CIRCLES INDICATE RECESSED,
OPEN CIRCLES INDICATE SURFACE-MOUNTED
DIAGONAL LINE INDICATES LENSED
OUTER DOTS INDICATE SUSPENDED
SIMPLEX RECEPTACLE
DUPLEX RECEPTACLE
LIGHTING FIXTURES, TYPICAL, ROUND
CENTER DOT INDICATES PENDANT
DIAGONAL LINE INDICATES LENSED
CHEVRON INDICATES WALL WASH
WALL-MOUNTED FIXTURES, TYPICAL
STRIP FIXTURE
DIRECTIONAL LIGHT, TRACK, FLOOD
LINEAR LIGHT, TAPE LIGHT
EMERGENCY LIGHTING UNIT, CEILING-MOUNTED,
INTEGRAL BATTERY
EMERGENCY LIGHTING UNIT, CEILING-
MOUNTED, REMOTE BATTERY
EMERGENCY LIGHTING UNIT, WALL-
MOUNTED, INTEGRAL BATTERY
EMERGENCY LIGHTING UNIT, WALL-
MOUNTED, REMOTE BATTERY
EXIT LIGHT, CEILING-MOUNTED, SHADING
AND ARROWS INDICATE FACES AND
DIRECTION
EXIT LIGHT, WALL-MOUNTED, SHADING
AND ARROWS INDICATE FACES AND
DIRECTION
EXIT/ELU COMBO
POLE/AREA LIGHTS
POST-TOP AREA LIGHT
BOLLARD LIGHT
DIAGONAL HATCH INDICATES
EMERGENCY LIGHT
OS
VS
OS D
VS D
OS
VS
OS
TC
SINGLE POLE SWITCH
3-WAY SWITCH
4-WAY SWITCH
KEYED SWITCH
LOW VOLTAGE MOMENTARY PUSHBUTTON OR
DECORATOR SWITCH
SWITCH W/PILOT
DIMMER SWITCH
FAN SPEED CONTROLLER. COORDINATE TYPE
WITH FAN MANUFACTURER.
OCCUPANCY SENSOR W/ MANUAL SWITCH
VACANCY SENSOR W/ MANUAL SWITCH
OCCUPANCY SENSOR W/ 0-10V DIMMER
VACANCY SENSOR W/ 0-10V DIMMER
OCCUPANCY SENSOR, CEILING MOUNTED
VACANCY SENSOR, CEILING MOUNTED
CORRIDOR OCCUPANCY SENSOR, CEILING
MOUNTED
TIMER SWITCH
TIME DELAY SWITCH
TIME CONTROL SWITCH
LIGHTING TAGS
TOP VALUE: FIXTURE TYPE ID
S3d
BOTTOM VALUE: LOWERCASE LETTER: SWITCH ID
BOTTOM VALUE: NUMBER(S): CIRCUIT NUMBER
ABSENCE OF A SWITCH ID INDICATES FIXTURE IS CONTROLLED BY THE
ONLY SWITCH IN THE SPACE. AN "nl" IN PLACE OF THE SWITCH ID
INDICATES NIGHT LIGHT (UNSWITCHED).
SWITCH ID INDICATED BY A LOWERCASE LETTER. SWITCH
IDS ARE UNIQUE PER SPACE. A SWITCH WITH AN ID "a"
CONTROLS ALL DEVICES WITHIN THE SPACE IN WHICH IT
IS LOCATED TAGGED WITH "a". A SWITCH WITHOUT A
TAGGED ID CONTROLS ALL LIGHTING FIXTURES WITHIN A
SPACE. ID TAGS MAY BE USED ON CONTROL DEVICES
OTHER THAN SWITCHES, SUCH AS OCCUPANCY SENSORS
OR CONTACTORS.
QUADRUPLEX RECEPTACLE
SPECIAL RECEPTACLE, TYPE AS INDICATED
J J J JUNCTION BOX
RECEPTACLE MODIFIERS:
##": HEIGHT AFF OC
AC: ABOVE COUNTER
WP: WEATHERPROOF IN-USE COVER
W/ WR RATED GFI RECEPTACLE
WPD: WEATHERPROOF NOT-IN-USE COVER
W/ WR RATED GFI RECEPTACLE
IG: ISOLATED GROUND
CENTER SHADING INDICATES GFI
HALF SHADING INDICATES SPLIT
(TYPICALLY SWITCHED)
OUTER SHADING INDICATES EMERGENCY
MULTIOUTLET ASSEMBLY,
FILLED SQUARES INDICATED 120V OUTLETS
RANGE RECEPTACLE, NEMA 14-50R
CORD REEL, DEVICE VARIES
DROP CORD, DEVICE VARIES
FLOORBOX, TYPE AS INDICATED
POKE THRU DEVICE, TYPE AS INDICATED
EPO
EMERGENCY POWER OFF SWITCH
METER
SAFETY SWITCH, NON-FUSED
SAFETY SWITCH, FUSED
MOTOR STARTER
COMBINATION STARTER/DISCONNECT
PUSHBUTTON
MOTOR
GROUND BAR
POWER DEVICE AND EQUIPMENT TAGS
d ELECTRICAL DEVICE TAGS: THE CIRCUIT DESIGNATION IS
INDICATED BY A NUMBER. THE SWITCH DESIGNATION IS
INDICATED BY A LOWER CASE LETTER (WHERE APPLICABLE).
EXAMPLE: SPLIT DUPLEX RECEPTACLE IS CONNECTED TO
CIRCUIT 1 AND ONE RECEPTACLE OUTLET IS CONTROLLED BY
SWITCH "d".
EQUIPMENT TAGS: EQUIPMENT ID IS INDICATED BY AN
UNDERLINED TAG ADJACENT TO THE EQUIPMENT. SEE THE
EQUIPMENT CONNECTION SCHEDULE FOR DESCRIPTION,
XX-1 ELECTRICAL REQUIREMENTS, AND PANEL AND CIRCUIT NUMBER.
SYMBOLS/GRAPHIC APPEARANCE OF EQUIPMENT VARIES.
POWER DISTRIBUTION EQUIPMENT
MDP HP1A LP1A
SB1
HATCHED FILL INDICATES DISTRIBUTION PANEL OR
SWITCHBOARD.
SOLID FILL INDICATES BRANCH PANEL OR LOAD CENTER.
DASHED BOX INDICATES CODE-REQUIRED CLEARANCE (WIDTH
AND DEPTH). DOOR INDICATES FRONT OF RECESSED PANEL.
T1 TRANSFORMER: TYPICALLY TRANSFORMER NAMES BEGIN WITH
OR CONTAIN THE LETTER "T". SEE SINGLE-LINE DIAGRAM FOR
DESCRIPTION AND REQUIREMENTS.
WIRING
CONDUIT SHOWN WITHOUT SLASH MARKS SHALL
CONTAIN 1 # 12 CONDUCTOR PER PHASE, NEUTRAL, AND
GROUND IN 1/2" CONDUIT UNLESS SPECIFIC EQUIPMENT
REQUIRES A DIFFERENT SIZE.
#10
P4N-102
1, 3, 5
CONDUIT SHOWN SHALL CONTAIN 1 # 10 CONDUCTOR
PER PHASE IN ELECTRICAL CODE SIZED MINIMUM
CONDUIT UNLESS A CONDUCTOR AND CONDUIT SIZE IS
SHOWN ADJACENT.
HOME RUN TO BRANCH CIRCUIT PANELBOARD. THE
PANELBOARD DESIGNATION IS SHOWN ADJACENT TO
THE HOME RUN ARROW AS A NUMERATOR AND THE
CIRCUIT DESIGNATION IS SHOWN AS THE DENOMINATOR.
CIRCUIT BREAKER SIZES (AMPS/NUMBER OF POLES) ARE
SHOWN IN THE PANELBOARD SCHEDULE WITH THE
CORRESPONDING PANELBOARD AND CIRCUIT
DESIGNATION. EXAMPLE: HOME RUN TO PANELBOARD
P4N-102; CIRCUITS 1, 3, 5. LONG TICKMARKS INDICATE
NUMBER OF PHASE CONDUCTORS. SHORT TICK MARKS
INDICATE NUMBER OF GROUNDED CONDUCTORS
(NEUTRALS). AN EQUIPMENT GROUNDING CONDUCTOR
IS NOT INDICATED BUT SHALL BE INSTALLED. NUMBER
OF ARROWHEADS INDICATE NUMBER OF CIRCUITS.
CONDUIT IN CEILING, FLOOR OR WALL AS REQUIRED BY
FIELD CONDITIONS
CONDUIT IN FLOOR
DATA OUTLET
VOICE OUTLET
DATA/VOICE OUTLET
WIRELESS ACCESS POINT
CATV OUTLET
SECURITY SYMBOLS
WALL MOUNTED SECURITY CAMERA
CEILING MOUNTED SECURITY CAMERA
CR
CARD READER
CK
CARD READER W/ KEYPAD
DC
DOOR CONTACT
ES
ELECTRIC STRIKE
ML
MAGNETIC LOCK
COMBINATION LOCK
REQUEST TO EXIT BUTTON
MD
MOTION DETECTOR
SECURITY SYSTEM KEYPAD
SOUND SYSTEM SYMBOLS
WALL MOUNTED SPEAKER
S
CEILING MOUNTED SPEAKER
V
VOLUME CONTROL
CONSTRUCTION PHASING
(TYPICAL ALL SYMBOLS AND EQUIPMENT)
(E)
EXISTING TO REMAIN
EXISTING TO BE REMOVED
NEW
EXISTING TO BE DEMOLISHED
MISCELLANEOUS
AREA NOT IN CONTRACT
1
KEY NOTE (SEE SCHEDULE)
-
NUMBER OF DETAIL ON SHEET
---
NUMBER OF SHEET WHERE DETAIL APPEARS
1
Room
6
REVISION NUMBER - SHOWN ON PLANS
ROOM NAME AND NUMBER
SHEET
E000
E101
E201
E202
E301
E302
E303
E304
E401
ELECTRICAL SHEET INDEX
DESCRIPTION
ELECTRICAL TITLE SHEET
COMPOSITE ELECTRICAL DEMOLITION PLAN
COMPOSITE POWER PLAN
COMPOSITE ROOF POWER PLAN
ENLARGED POWER PLAN - ADMIN, MEDIA, & CAFE
ENLARGED POWER PLAN - GYM & WING A
ENLARGED POWER PLAN - WING B & C
ENLARGED POWER PLAN - WING D & E
ELECTRICAL EQUIPMENT SCHEDULES
ELECTRICAL GENERAL NOTES
A THE SYMBOLS AND ABBREVIATIONS SHOWN ON THIS SHEET MAY OR MAY NOT BE
USED IN THIS SET OF DRAWINGS.
B LOW VOLTAGE CABLES OR CONDUCTORS OPERATING AT LESS THAN 50 VOLTS SHALL
BE IN METAL RACEWAY WHERE INSTALLED WITHIN WALLS OR INACCESSIBLE SPACES
OR INSTALLED WHERE EXPOSED AND SUBJECT TO PHYSICAL DAMAGE. LOW
VOLTAGE CABLES MAY BE RUN IN CABLE TRAY. LOW VOLTAGE CABLES MAY BE RUN IN
CABLE SUPPORT HOOKS ABOVE ACCESSIBLE CEILINGS. LOW VOLTAGE CABLES SHALL
BE PLENUM RATED IN PLENUM SPACES.
C COORDINATE LOCATIONS OF DEVICES WITH ARCHITECTURAL ELEVATIONS AND
DETAILS. ARCHITECTURAL ELEVATIONS AND DETAILS TAKE PRECEDENCE OVER
LOCATIONS SHOWN ON ELECTRICAL DRAWINGS.
D PROVIDE CABLE OR CONDUIT AND WIRE AS REQUIRED TO ACHIEVE CIRCUITING
SHOWN. SIZE CONDUCTORS PER NEC AMPACITY AND WIRE FILL CRITERIA. PROVIDE
DEDICATED NEUTRAL AND GROUND CONDUCTORS FOR CIRCUITING ,UNLESS NOTED
OTHERWISE. INCREASE BRANCH CIRCUIT AND/OR FEEDER CONDUCTORS INCLUDING
EQUIPMENT GROUNDING CONDUCTORS PROPORTIONALLY FOR NO MORE THAN 3%
VOLTAGE DROP ON BRANCH CIRCUITS AND 2% ON FEEDERS PER ENERGY CODE.
E IT IS THE RESPONSIBILITY OF THIS CONTRACTOR TO COORDINATE INSTALLATION OF
ELECTRICAL SYSTEMS AND THOSE REQUIRING ELECTRICAL CONNECTIONS TO
MAINTAIN NEC REQUIRED CLEARANCES, INCLUDED BY NOT LIMITED TO AREAS ABOVE
ACCESSIBLE CEILINGS.
F COORDINATE WITH OTHER TRADES FOR PROPER INSTALLATION OF EQUIPMENT.
CONSULT THE DRAWINGS OF OTHER TRADES OR CRAFTS TO AVOID CONFLICTS WITH
EQUIPMENT, ETC. CONFLICTS SHALL BE RESOLVED PRIOR TO ROUGH-IN AND AT NO
ADDITIONAL COST TO THE OWNER.
G LEAVE THE SITE CLEAN AND READY FOR OCCUPANCY. REMOVE DIRT, DEBRIS, EMPTY
CARTONS, TOOLS, CONDUIT AND WIRE SCRAPS AND MISCELLANEOUS SPARE
EQUIPMENT AND MATERIALS USED IN THIS DIVISION OF THE WORK DURING
CONSTRUCTION. COMPONENTS SHALL BE FREE OF DUST, GRIT AND FOREIGN
MATERIALS AND LEFT AS NEW BEFORE FINAL ACCEPTANCE OF WORK.
H CONDUCTORS OPERATING AT 50 VOLTS OR GREATER SHALL BE IN RACEWAY.
RACEWAY WITHIN THE STRUCTURE ABOVE THE FLOOR SLAB SHALL BE METAL.
RACEWAY BELOW THE FLOOR SLAB AND UNDERGROUND RACEWAY OUTSIDE THE
STRUCTURE SHALL BE PVC.
I PERFORM WORK TO COMPLY WITH THE STANDARD PRACTICES FOR GOOD
WORKMANSHIP PUBLISHED BY NATIONAL ELECTRICAL CONTRACTORS ASSOCIATION
(NECA). COMPLY WITH THE LATEST ENFORCED EDITION OF THE NATIONAL
ELECTRICAL CODE (NEC), LOCAL CODES, AMENDMENTS, AND ORDINANCES.
J FIELD COORDINATE FINAL MECHANICAL AND PLUMBING EQUIPMENT LOCATIONS
ALONG WITH CONNECTION REQUIREMENTS AND CONTROL WIRING PRIOR TO
ROUGH-IN. ADJUST CORRESPONDING CIRCUIT BREAKER RATINGS AND BRANCH
CIRCUITING ACCORDINGLY. PROVIDE ADDITIONAL BRANCH CIRCUITS FROM SPARE
CIRCUIT BREAKERS TO ACCOMMODATE ANY CONTROL PANELS AND ACCESSORIES
REQUIRING POWER.
K ELECTRICAL WORK SHALL BE PERFORMED UNDER THE SUPERVISION OF A LICENSED
MASTER ELECTRICIAN. PROCURE PERMITS AND LICENSES AND PAY FEES
ASSOCIATED WITH THIS WORK.
L MATERIALS FURNISHED FOR THIS PROJECT SHALL BE NEW, COMMERCIAL GRADE,
FREE OF DEFECTS, AND LISTED BY A NATIONALLY RECOGNIZED TESTING
LABORATORY UNO.
M PROVIDE COMPLETE OPERATION & MAINTENANCE MANUAL INCLUDING APPROVED
SUBMITTAL DRAWINGS, WARRANTY INFORMATION FOR PRODUCT SUPPLIED,AND
MANUFACTURER'S OPERATION AND MAINTENANCE INSTRUCTIONS.
N THE CONTRACTOR IS RESPONSIBLE FOR MAKING FINAL WIRING TERMINATIONS TO
PRE-INSTALLED RECEPTACLES IN OFFICE FURNITURE. CONTRACTOR IS RESPONSIBLE
FOR WIRING AND INSTALLING VOICE/DATA DEVICES IN OFFICE FURNITURE.
COORDINATE PLACEMENT OF DEVICES WITH FURNITURE LAY-OUT.
O SECURITY SYSTEM TO BE PROVIDED UNDER SEPARATE CONTRACT. IT IS THE
RESPONSIBILITY OF THIS CONTRACTOR TO PROVIDE CONDUIT PROVISIONS, BACK
BOXES, ROUGH-INS, SLEEVES AND POWER TO HEAD END EQUIPMENT FOR EXACT
REQUIREMENTS PRIOR TO START OF WORK.
P CONDUIT AND WIRE SHALL NOT BE INSTALLED BELOW FLOOR SLAB UNLESS
INDICATED ON PLAN BY DASHED CONDUIT.
Q CONTRACTOR SHALL BE RESPONSIBLE FOR WIRING ELECTRICAL ITEMS SHOWN ON
DRAWINGS EXCEPT FOR ITEMS LISTED BELOW. THESE ITEMS SHALL CONSIST OF A
BACK BOX WITH CONDUIT STUBBED ABOVE THE ACCESSIBLE CEILING, SEE STUB UP
DETAIL. VERIFY SIZE OF BACK BOX REQUIRED WITH DEVICE TO BE INSTALLED.
LOCATE BACK BOXES 6" FROM ADJACENT POWER RECEPTACLE INTENDED FOR
COMPUTER USE.
- TV OUTLETS
- VOLUME CONTROLS
- TELEPHONE OUTLETS
- DATA OUTLETS
- FIRE ALARM DEVICES
R FURNISH AND INSTALL CONDUIT FROM BACK BOXES FOR THE FOLLOWING DEVICES
INTO THE ACCESSIBLE CEILING SPACE IN THE CORRIDOR, UNLESS NOTED
OTHERWISE:
- 1"C TV OUTLETS
- 1/2"C VOLUME CONTROLS
- 3/4"C DOOR SECURITY DEVICES (CARD READERS, DOOR STRIKES ETC.)
- 1"C TELEPHONE OUTLETS
- 1"C DATA OUTLETS
- 3/4"C FIRE ALARM DEVICES
ELECTRICAL REMODEL NOTES
A BRANCH CIRCUITING INDICATED ON PLANS AND SCHEDULES IS BASED UPON EXISTING
PLANS AND SITE OBSERVATION, CONTRACTOR TO FIELD VERIFY.
B PROVIDE TYPED CIRCUIT BOARD DIRECTORIES TO REFLECT AS-CONSTRUCTED
CONDITIONS. FIELD VERIFY DURING CONSTRUCTION AND REVISE ACCORDINGLY.
C PROVIDE NECESSARY DEMOLITION TO FACILITATE NEW CONSTRUCTION WORK
ASSOCIATED WITH THIS PROJECT. COORDINATE OUTAGES WITH OWNER MINIMUM 72
HOURS IN ADVANCE. OWNER RETAINS RIGHT TO FIRST SALVAGE. PROVIDE DISPOSAL
OF REMOVED MATERIAL. MAINTAIN CIRCUIT CONTINUITY AS REQUIRED.
D IT IS THE INTENT OF THESE DIAGRAMMATIC DRAWINGS TO PROVIDE THE PROJECT
SCOPE INCLUDING, BUT NOT LIMITED TO PHASED DEMOLITION AND NEW
CONSTRUCTION. EXISTING INFORMATION INDICATED ON THESE PLANS DOES NOT
REPRESENT ALL EXISTING CONDITIONS. THIS CONTRACTOR SHALL BECOME FAMILIAR
WITH EXISTING CONDITIONS, SCOPE OF PHASING, AND PROJECT INTENT PRIOR TO BID
SUBMISSION.
E PROVIDE CUTTING, PATCHING, AND RESTORATION OF FINISHES NECESSARY FOR
WORK SURFACES DAMAGED BY THIS WORK. SPACES AROUND CONDUITS PASSING
THROUGH FLOORS AND WALLS SHALL BE NEATLY PATCHED AND FINISHED TO MATCH
NEW/EXISTING. STRUCTURAL MEMBERS SHALL NOT BE CUT OR PENETRATED IN ANY
MANNER. THE SPACES AROUND THE CONDUITS SHALL BE SEALED TO PREVENT
ENTRANCE OF MOISTURE. PROVIDE FIRE STOPPING PER UL APPROVED METHODS.
F REMOVE ABANDONED WIRING COMPLETE. AT CONTRACTORS OPTION, UTILIZE
EXISTING ABANDONED RACEWAY TO EXTENT AVAILABLE. EXPOSED ABANDONED
RACEWAY SHALL BE REMOVED.
No.
G COORDINATE WORK IN PHASES WITH GENERAL CONTRACTOR AND OWNER TO
FACILITATE DEMOLITION AND NEW CONSTRUCTION.
H REMOVE ELECTRICAL RELATED EQUIPMENT (I.E JUNCTION BOXES, RECEPTACLES,
SWITCHES, DEVICES, ETC... ) AFFECTED/ABANDONED AS A RESULT OF DEMOLITION
AND NEW CONSTRUCTION.
1020 Drayton St., Suite 101
Savannah, GA 31401
(912) 963-1611
www.MethodEG.com
E
O
REGI
RG
STERED
I
No. PE041545
PROFESSIONAL
11/21/25
T
O
ENGINEER
PHER G.
SH
Revision Schedule
Description
Date
ELECTRICAL
TITLE SHEET
Project number
Date
Drawn by
Checked by
2123
NOVEMBER 2025
ELP
CGS
E000
DEMOLITION SHEET NOTES
A SEE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR PHASES OF
DEMOLITION AND CONSTRUCTION. COORDINATE WITH GENERAL CONSTRUCTION.
B DISCONNECT AND REMOVE ALL ELECTRICAL DEVICES AND LIGHTING FIXTURES IN
DEMOLITION AREAS UNLESS NOTED OTHERWISE.
C DISCONNECT AND REMOVE ALL ELECTRICAL DEVICES IN WALLS TO BE
DEMOLISHED. WALLS TO BE DEMOLISHED ARE SHOWN DASHED. DISCONNECT
AND REMOVE ASSOCIATED CONDUIT AND WIRE BACK TO LAST REMAINING DEVICE.
FURNISH AND INSTALL CONDUIT AND WIRE AS NECESSARY FOR CONTINUITY OF
CIRCUIT(S) TO ANY EXISTING DEVICES TO REMAIN. COORDINATE AND VERIFY
REQUIREMENTS WITH NEW WORK IN AREA.
D FURNISH AND INSTALL CONDUIT AND WIRE AS NECESSARY FOR CONTINUITY OF
ANY FEEDERS OR BRANCH CIRCUITS ORIGINATING OUTSIDE THE DEMOLITION
AREA THAT SERVES ANY ELECTRICAL EQUIPMENT OR DEVICES TO REMAIN AFTER
DEMOLITION. MODIFY OR REPLACE AS REQUIRED.
E FURNISH AND INSTALL CONDUIT AND/OR COMMUNICATIONS/DATA WIRING AS
NECESSARY FOR CONTINUITY OF ANY WIRING ORIGINATING OUTSIDE THE
DEMOLITION AREA THAT SERVES ANY COMMUNICATIONS/DATA EQUIPMENT OR
DEVICES TO REMAIN AFTER DEMOLITION. MODIFY OR REPLACE AS REQUIRED.
F DISCONNECT AND REMOVE LIGHT SWITCHES IN DEMOLITION AREAS AS
NECESSARY TO ACCOMMODATE NEW DOOR CONFIGURATIONS.
G DISCONNECT AND REMOVE ANY EXISTING ELECTRICAL DEVICES AND BACK BOXES
AS NECESSARY WHERE NEW WALL CONSTRUCTION WILL INTERSECT AN EXISTING
WALL. FURNISH AND INSTALL CONDUIT AND WIRE AS REQUIRED FOR CONTINUITY
OF CIRCUIT(S).
H FURNISH AND INSTALL BLANK COVER PLATES OVER ALL EXISTING UNUSED
OPENINGS.
1020 Drayton St., Suite 101
Savannah, GA 31401
(912) 963-1611
www.MethodEG.com
WING A
WING B
WING C
WING D
STORAGE SHED
001
CLASSROOM
512
CLASSROOM
511
GYMNASIUM
EXISTING AIR HANDLING
UNIT BEING DEMOLISHED.
CCLLAASSSSRROOOOMM
551133
CLASSROOM
510
(E)AHU-3
STORAGE
622
BOYS TOILET
621
JANITOR
GYM
620
617
GIRLS TOILET
619
OFFICE
618
ELECT
612
(E)
LPF
(E)
BOOK STORAGE
613
HPF
(E)
GIRLS TOILET
614
JANITOR
615
Space
002
BOYS TOILET
616
CORRIDOR
601
CLASSROOM
611
CLASSROOM
610
CLASSROOM
609
CLASSROOM
514
CORRIDOR
501
CLASSROOM
509
CLASSROOM
515
CLASSROOM
508
CLASSROOM
516
BOOK STORAGE
517
MECHANICAL
502
VESTIBULE
506
JANITOR
507
VESTIBULE
503
BOYS TOILET
505
GIRLS TOILET
504
EXISTING ERU BEING
DEMOLISHED.
(E)ERU-4
BOOK STORAGE
606 CORRIDOR
HPC (E)
(E)
(E)LPC
ART
607
KILN
608
605
CONFERENCE
(E)LPC1
604
(E)HPD
BOOK STORAGE
(E)
603
(E)
AV STORAGE
151
ELECTRICAL
602
MEDIA DISTRIBUTION
150
CLASSROOM
412
CLASSROOM
413
CLASSROOM
411
CLASSROOM
410
CLASSROOM
312
CLASSROOM
313
CLASSROOM
311
CLASSROOM
310
CLASSROOM
212
CLASSROOM
213
CLASSROOM
211
CLASSROOM
210
WING E
CLASSROOM
807
CLASSROOM
806
CLASSROOM
414
CORRIDOR
401
CLASSROOM
409
CLASSROOM
415
CLASSROOM
408
CLASSROOM
314
CORRIDOR
301
CLASSROOM
309
CLASSROOM
315
CLASSROOM
308
CLASSROOM
214
CORRIDOR
201
CLASSROOM
209
CLASSROOM
215
CLASSROOM
208
CLASSROOM
808
CLASSROOM
805
CLASSROOM
809
CORRIDOR
801
CLASSROOM
804
CLASSROOM
416
VESTIBULE
406
JANITOR
407
BOYS TOILET
405
VESTIBULE
403
GIRLS TOILET
404
CLASSROOM
316
(E)ERU-3
MECHANICAL
402
EXISTING ERU BEING
DEMOLISHED.
FACULTY DINING
124
CORRIDOR
125
(E)AHU-2
OFFICE
144
RESOURCE
142
MENS TOILET
127
MB
(E)
MECHANICAL
126
WORK ROOM
145
MEDIA
CENTER
WOMENS TOILET
141
PASSAGE
128
SUPPLY
140
TOILET
131
VESTIBULE
152
EXISTING AIR HANDLING
UNITS BEING DEMOLISHED.
CAFETERIA
TOILET
139
MEDIA PRODUCTION
146
(E)GF-1
CLINIC
137
VICE PRINCIPAL
136
VAULT
135
PRINCIPAL
129
OFFICE
132
CONFERENCE
133
RECEPTION
134
OFFICE
102
LOBBY
101
VESTIBULE
306
VESTIBULE
206
BOYS TOILET
205
JANITOR
307
VESTIBULE
303
MECHANICAL
302
CORRIDOR
317
(E)ERU-2
CLASSROOM
216
JANITOR
207
VESTIBULE
203
GIRLS TOILET
204
EXISTING ERU BEING
DEMOLISHED.
(E)ERU-1
MECHANICAL
202
EXISTING ERU BEING
DEMOLISHED.
CLASSROOM
810
CLASSROOM
803
EXISTING ERU BEING
DEMOLISHED.
SPED CONFERENCE (E)ERU-5
811
MECHANICAL
802
CORRIDOR (E)AHU-1
125
ELECTRICAL
118
CORRIDOR
123
JANITOR
116
BOOK STORAGE
115
TOILET
114
(E) LPB
(E)
HPB
(E)LPA
(E)
(E)HPA
MECHANICAL
117
MSB
(E)
HPK(E)
HPK1(E)
(E)
LPK (E)
LPK1(E)
CONFERENCE
120
BOOK STORAGE
119
CONFERENCE
121
DISH RETURN
105
FREEZER
00
EMPLOYEE LOCKER
113
COOLER
00
SERVING
107
JANITOR
111
MA
DRY STORAGE (E)
112
KITCHEN
CAN WASH
110
SERVING
104
DISH WASH
106
(E)
(E)
OFFICE
109
(E)
(E)
EXISTING CEILING
RECESSED UNIT
VENTILATORS
BEING DEMOLISHED.
EXISTING AIR
HANDLING UNIT,
PUMPS AND BOILER
BEING DEMOLISHED.
EXISTING CHILLER
BEING DEMOLISHED.
CONFERENCE
122
BOOK ROOM
703
SPED CONFERENCE
702
ELECT
704
CLASSROOM
705
(E) HN1
(E) HN
LN1(E)
LN(E)
(E)
CORRIDOR
701
VEST. JANITOR VEST.
G02 707 G05
BOYS TOILET
706
GIRLS TOILET
708
CLASSROOM
709
(E)CU-5
EXISTING SPLIT
ERU CONDENSING
UNIT BEING
DEMOLISHED.
CONFERENCE
148
EXISTING CEILING
RECESSED UNIT
VENTILATORS
BEING DEMOLISHED.
1 COMPOSITE ELECTRICAL DEMOLITION PLAN
E101 1" = 20'-0"
A
B
C
D
E
GYM
ADMIN/MEDIA/
CAF/KITCHEN
KEY PLAN
E
O
REGI
R
STE
G
RED
I
No. PE041545
PROFESSIONAL
11/21/25
T
O
ENGINEER
PHER G.
SH
Revision Schedule
No.
Description
Date
COMPOSITE
ELECTRICAL
DEMOLITION
PLAN
Project number
Date
Drawn by
Checked by
2123
NOVEMBER 2025
ELP
CGS
E101
POWER SHEET NOTES
A WHERE CONNECTED TO A 20A. BRANCH CIRCUIT SUPPLYING AN INDIVIDUAL
RECEPTACLE (SIMPLEX OR DUPLEX), THE RECEPTACLE SHALL BE RATED AT 20A.
B CIRCUIT WIRING IS NOT SHOWN, PROVIDE PROPER NUMBER OF CONDUCTORS TO
ACHIEVE CIRCUITING AND SWITCHING SHOWN.
C CIRCUIT NUMBERS AT DEVICES CORRESPOND TO PANELBOARD BREAKERS (SEE
PANELBOARD SCHEDULE). BRANCH CIRCUITS SHALL BE SIZED ACCORDING TO
THE CIRCUIT BREAKER RATING, UNLESS INDICATED OTHERWISE ON THE
ELECTRICAL EQUIPMENT SCHEDULE.
D PROVIDE HOUSEKEEPING PADS FOR ALL FLOOR MOUNTED AND GRADE MOUNTED
ELECTRICAL EQUIPMENT. MINIMUM REQUIREMENTS: 4" HIGH, 4% AIR ENTRAINED,
POLYFIBER REINFORCED CONCRETE, 4" WIDER AND 4" LONGER THAN EQUIPMENT
TO BE PLACED ON IT. REFER TO ELECTRICAL DETAIL DRAWINGS FOR
TRANSFORMER, GENERATOR, OR SWITCHGEAR PADS THAT MAY EXCEED THESE
REQUIREMENTS.
1020 Drayton St., Suite 101
Savannah, GA 31401
(912) 963-1611
www.MethodEG.com
WING A
CLASSROOM
512
CLASSROOM
511
GYMNASIUM
GYM
617
HP-3-1
WP
HP-3-2
AH-3-1
HT
AH-3-2
DH-3
MC1
STORAGE
622
BOYS TOILET
621
JANITOR
620
GIRLS TOILET
619
OFFICE
618
(E)
LPF BOOK STORAGE
(E)
613
HPF
(E)
GIRLS TOILET
614
JANITOR
615
Space
002
BOYS TOILET
616
CORRIDOR
601
ART
CLASSROOM
CLASSROOM
CLASSROOM
607
611
610
609
CLASSROOM
513
CLASSROOM
510
CLASSROOM
514
CORRIDOR
501
CLASSROOM
509
CLASSROOM
515
CLASSROOM
508
CLASSROOM
516
BOOK STORAGE
517
VESTIBULE
506
JANITOR
507
BOYS TOILET
505
VESTIBULE
503
GIRLS TOILET
504
MECHANICAL
502
DOAS-1
CORRIDOR
501
TH
BOOK STORAGE
606
CORRIDOR
605
KILN
608
(E)HPC (E)
(E)
(E) LPC
CONFERENCE
604
(E)LPC1
(E)HPD
BOOK STORAGE
(E)
AV STORAGE
151
603 LPD (E)
ELECTRICAL
602
WING B
CLASSROOM
412
CLASSROOM
413
CLASSROOM
411
CLASSROOM
410
WING C
CLASSROOM
312
CLASSROOM
313
CLASSROOM
311
CLASSROOM
310
WING D
CLASSROOM
212
CLASSROOM
213
CLASSROOM
211
CLASSROOM
210
STORAGE SHED
001
WING E
CLASSROOM
807
CLASSROOM
806
CLASSROOM
414
CORRIDOR
401
CLASSROOM
409
CLASSROOM
415
CLASSROOM
408
CLASSROOM
314
CORRIDOR
301
CLASSROOM
309
CLASSROOM
315
CLASSROOM
308
CLASSROOM
214
CLASSROOM
209
CLASSROOM
215
CORRIDOR
201
CLASSROOM
208
CLASSROOM
808
CLASSROOM
805
CLASSROOM
809
CORRIDOR
801
CLASSROOM
804
CORRIDOR
125
CLASSROOM
416
VESTIBULE
406
BOYS TOILET
405
JANITOR
407
VESTIBULE
403
GIRLS TOILET
404
DOAS-2
TH
CORRIDOR
401
MECHANICAL
402
CLASSROOM
316
FACULTY DINING
124
OFFICE
TH
144
RESOURCE
142
MENS TOILET
127
MECHANICAL
126
(E)
MB
AH-2
MEDIA
CENTER
WORK ROOM
145
WOMENS TOILET
141
AH-4
MEDIA PRODUCTION
146
SUPPLY
140
TOILET
139
CLINIC
137
TOILET
131
VESTIBULE
152
PRINCIPAL
129
VICE PRINCIPAL
136
OFFICE
132
VAULT
135
CONFERENCE
133
CAFETERIA
RECEPTION
134
OFFICE
102
LOBBY
101
BOYS TOILET
305
VESTIBULE
303
GIRLS TOILET
304
TH
CORRIDOR
317
DOAS-3
MECHANICAL
302
CLASSROOM
216
VESTIBULE
206
BOYS TOILET
205
JANITOR
207
VESTIBULE
203
GIRLS TOILET
204
TH
DOAS-4
MECHANICAL
202
CLASSROOM
810
CLASSROOM
803
SPED CONFERENCE
811
TH
MECHANICAL
802
DOAS-5
DISH RETURN
105
SERVING
104
DISH WASH
106
COR1R2I5DTOR
ELECTRICAL
118
BOOK STORAGE
JANITOR
(E)LPB
116
MECHANICAL
117 (E)HPB
(E)
BOOK STORAGE
LPA (E)
115 AH-1-1
(E)
HPA (E)
119
HPK(E)
HPK1(E)
LPK(E)
LPK1(E)
CONFERENCE
120
TOILET
114
MSB
(E)
FREEZER EMPLOYEE LOCKER
00
113
COOLER
00
AH-1-2
MA
(E)
MC
T-LC
LC
WP
SERVING
107
DAH-2
DRY STORAGE
112
JANITOR
111
CAN WASH
WP
110
DHP-2
(E)
OFFICE
109
(E)
(E)
(E)
HP-1-2
HP-1-1
KITCHEN
DAH-1
WP
DHP-1
CORRIDOR
123
CONFERENCE
121
CORRIDOR
701
CONFERENCE
122
BOOK ROOM
SPED CONFERENCE 703
702
ELECT
704
CLASSROOM
705
(E)HN1
(E) HN
LN1 (E)
LN (E)
(E)
VEST. JANITOR VEST.
G02
707
G05
BOYS TOILET GIRLS TOILET
706
708
CLASSROOM
709
E
O
REGI
R
STE
G
RED
I
No. PE041545
PROFESSIONAL
11/21/25
T
O
ENGINEER
PHER G.
SH
Revision Schedule
No.
Description
Date
COMPOSITE
POWER PLAN
1 COMPOSITE POWER PLAN
E201 1" = 20'-0"
A
B
C
D
E
GYM
ADMIN/MEDIA/
CAF/KITCHEN
KEY PLAN
Project number
Date
Drawn by
Checked by
2123
NOVEMBER 2025
ELP
CGS
E201
POWER SHEET NOTES
A WHERE CONNECTED TO A 20A. BRANCH CIRCUIT SUPPLYING AN INDIVIDUAL
RECEPTACLE (SIMPLEX OR DUPLEX), THE RECEPTACLE SHALL BE RATED AT 20A.
B CIRCUIT WIRING IS NOT SHOWN, PROVIDE PROPER NUMBER OF CONDUCTORS TO
ACHIEVE CIRCUITING AND SWITCHING SHOWN.
C CIRCUIT NUMBERS AT DEVICES CORRESPOND TO PANELBOARD BREAKERS (SEE
PANELBOARD SCHEDULE). BRANCH CIRCUITS SHALL BE SIZED ACCORDING TO
THE CIRCUIT BREAKER RATING, UNLESS INDICATED OTHERWISE ON THE
ELECTRICAL EQUIPMENT SCHEDULE.
D PROVIDE HOUSEKEEPING PADS FOR ALL FLOOR MOUNTED AND GRADE MOUNTED
ELECTRICAL EQUIPMENT. MINIMUM REQUIREMENTS: 4" HIGH, 4% AIR ENTRAINED,
POLYFIBER REINFORCED CONCRETE, 4" WIDER AND 4" LONGER THAN EQUIPMENT
TO BE PLACED ON IT. REFER TO ELECTRICAL DETAIL DRAWINGS FOR
TRANSFORMER, GENERATOR, OR SWITCHGEAR PADS THAT MAY EXCEED THESE
REQUIREMENTS.
ADDITIONAL ROOF POWER SHEET NOTES
A WHERE BRANCH CIRCUITS TO EQUIPMENT ARE INSTALLED HORIZONTALLY
ABOVE THE ROOF, PROVIDE ROOF SUPPORTS SUCH THAT CONDUITS ARE
INSTALLED APPROXIMATELY 6" ABOVE ROOF. BASIS OF DESIGN ROOF
SUPPORT SHALL BE EATON DURA-BLOK. CONDUCTORS AMPACITIES,
INCLUDING EQUIPMENT GROUNDING CONDUCTOR, SHALL BE INCREASED BY
10% AND A MINIMUM ONE SIZE ABOVE WHAT IS INDICATED ON EQUIPMENT
CONNECTIONS SCHEDULE. CONDUIT SHALL BE INCREASED AS NECESSARY
FOR NEW SIZE CONDUCTORS PER NEC FILL CAPACITIES.
B COORDINATE WITH DIV. 23 FOR LOCATIONS OF EQUIPMENT AND MOUNTING OF
RECEPTACLES TO EQUIPMENT OR SUPPORT STRUCTURES. PROVIDE
ADDITIONAL RECEPTACLES ON SAME RECEPTACLE CIRCUIT AS REQUIRED TO
HAVE A RECEPTACLE WITHIN 25' OF ALL EQUIPMENT.
KEYNOTES
1 PROVIDE NEW 25A/3P BREAKER IN EXISTING PANEL MB (MECHANICAL 126) FOR
CONNECTION TO NEW MECHANICAL EQUIPMENT. BREAKER AND WIRE SIZE SHALL
MATCH WHAT IS SHOWN ON ELECTRICAL EQUIPMENT SCHEDULE.
2 PROVIDE NEW 20A/1P BREAKER IN EXISTING PANEL LPF (ELECTRICAL 612) FOR
CONNECTION TO NEW WP,GFCI DUPLEX RECEPTACLE. UTILIZE ONE 1P SPACE IN
PANEL.
1020 Drayton St., Suite 101
Savannah, GA 31401
(912) 963-1611
www.MethodEG.com
GYMNASIUM
WING A
WING B
WING C
WING D
WING E
1 COMPOSITE ROOF POWER PLAN
E202 1" = 20'-0"
1
HP-2
HP-4
(E)
(E)
MEDIA
(E)
2
LC
6,8
(E)
CAFETERIA
CENTER
(E)
(E)
(E)
(E)
(E)
KITCHEN
(E)
(E)
E
O
REGI
R
STE
G
RED
I
No. PE041545
PROFESSIONAL
11/21/25
T
O
ENGINEER
PHER G.
SH
Revision Schedule
No.
Description
Date
COMPOSITE
ROOF POWER
PLAN
A
B
C
D
E
GYM
ADMIN/MEDIA/
CAF/KITCHEN
KEY PLAN
Project number
Date
Drawn by
Checked by
2123
NOVEMBER 2025
ELP
CGS
E202
This is the opportunity summary page. It provides an overview of this opportunity and a preview of the attached documentation.
Daily notification on new contract opportunities

With GovernmentContracts, you can:

  • Find more opportunities and win more business
  • Receive daily alerts for all new bid opportunities
  • Get contract opportunities matched to your business
ONE WEEK FREE TRIAL

See also

...) at, 200 Bradwell Street, Hinesville, Georgia 31313. The advertising dates for this ...

Liberty County School System

Bid Due: 2/27/2060

...Photography Services, Not Including Aerial Photography 91582 Video Production Services 91510 Advertising...

State Government of Georgia

Bid Due: 7/07/2026

...and Advertising, Resources Management Branch and Headquarters Section. The contractor shall provide...

DEPT OF DEFENSE

Bid Due: 6/15/2026

..., and Promotional Materials 03778 Souvenirs and Prizes: Promotional, Advertising, etc. 03752 Novelties...

State Government of Georgia

Bid Due: 6/09/2026

* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.