ELECTRICAL ABBREVIATIONS LIST
1P
1 POLE (2P, 3P, 4P, ETC.)
A, AMP AMPERE
AC
ABOVE COUNTER
ACLG ABOVE CEILING
ADO AUTOMATIC DOOR OPENER
AF
AMP FRAME
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFI ARC FAULT CIRCUIT
INTERRUPTER
AHU AIR HANDLING UNIT
AL
ALUMINUM
ALT ALTERNATE
AMP AMPERE
AMPL AMPLIFIER
ANNUN ANNUNCIATOR
APPROX APPROXIMATELY
AQ-STAT AQUASTAT
ARCH ARCHITECT, ARCHITECTURAL
AS
AMP SWITCH
AT
AMP TRIP
ATS AUTOMATIC TRANSFER SWITCH
AUTO AUTOMATIC
AUX AUXILIARY
AV
AUDIO VISUAL
AWG AMERICAN WIRE GAUGE
BATT BATTERY
BD
BOARD
BLDG BUILDING
BMS BUILDING MANAGEMENT SYSTEM
C
CONDUIT
CAB CABINET
CAT CATALOG
CATV CABLE TELEVISION
CB
CIRCUIT BREAKER
CCTV CLOSED CIRCUIT TELEVISION
CKT CIRCUIT
CLG CEILING
COMB COMBINATION
CMPR COMPRESSOR
CONN CONNECTION
CONST CONSTRUCTION
CONT CONTINUATION OR CONTINUOUS
CONTR CONTRACTOR
CONV CONVECTOR
CP
CIRCULATING PUMP
CRT CATHODE-RAY TUBE
CT
CURRENT TRANSFORMER
CTR CENTER
CU
COPPER
DCP DOMESTIC WATER CIRCULATING PUMP
DEPT DEPARTMENT
DET DETAIL
DIA DIAMETER
DISC DISCONNECT
DIST DISTRIBUTION
DN
DOWN
DPR DAMPER
DS
SAFETY DISCONNECT SWITCH
DT
DOUBLE THROW
DWG DRAWING
EC
ELECTRICAL CONTRACTOR
ELEC ELECTRIC, ELECTRICAL
ELEV ELEVATOR
ELU EMERGENCY LIGHTING UNIT
EM EMERGENCY
EMS ENERGY MANAGEMENT SYSTEM
EMT ELECTRICAL METALLIC TUBING
EP
ELECTRIC PNEUMATIC
EQUIP EQUIPMENT
EWC ELECTRIC WATER COOLER
EXIST EXISTING
EXH EXHAUST
EXP EXPLOSION PROOF
FA
FIRE ALARM
FABP FIRE ALARM BOOSTER POWER
SUPPLY PANEL
FACP FIRE ALARM CONTROL PANEL
FCU FAN COIL UNIT
FIXT FIXTURE
FLR FLOOR
FLUOR FLUORESCENT
FU
FUSE
FUDS FUSED SAFETY DISCONNECT SWITCH
GA GAUGE
GAL GALLON
GALV GALVANIZED
GC GENERAL CONTRACTOR
GEN GENERATOR
GFI GROUND FAULT CIRCUIT INTERRUPTER
GFP GROUND FAULT PROTECTOR
GND GROUND
GRS GALVANIZED RIGID STEEL (CONDUIT)
GYP BD GYPSUM BOARD
HOA HANDS-OFF-AUTOMATIC SWITCH
HORIZ HORIZONTAL
HP
HORSEPOWER
HPF HIGH POWER FACTOR
HT
HEIGHT
HTG HEATING
HTR HEATER
HV
HIGH VOLTAGE
HVAC HEATING, VENTILATING AND AIR
CONDITIONING
IC
INTERRUPTING CAPACITY
IG
ISOLATED GROUND
IMC INTERMEDIATE METAL CONDUIT
INCAND INCANDESCENT
IR
INFRARED
I/W INTERLOCK WITH
J-BOX JUNCTION BOX
KV
KILOVOLT
KVA KILOVOLT-AMPERE
KVAR KILOVOLT-AMPERE REACTIVE
KW KILOWATT
KWH KILOWATT HOUR
LOC LOCATE OR LOCATION
LT
LIGHT
LTG LIGHTING
LTNG LIGHTNING
LV
LOW VOLTAGE
MAX MAXIMUM
MAG.S MAGNETIC STARTER
M/C MOMENTARY CONTACT
MC MECHANICAL CONTRACTOR
MCB MAIN CIRCUIT BREAKER
MCC MOTOR CONTROL CENTER
MDC MAIN DISTRIBUTION CENTER
MDP MAIN DISTRIBUTION PANEL
MFR MANUFACTURER
MFS MAIN FUSED DISCONNECT SW
MH MANHOLE
MIC MICROPHONE
MIN MINIMUM
MISC MISCELLANEOUS
MLO MAIN LUGS ONLY
MMS MANUAL MOTOR STARTER
MOA MULTIOUTLET ASSEMBLY
MSP MOTOR STARTER PANELBOARD
MSBD MAIN SWITCHBOARD
MT MOUNT
MT.C EMPTY CONDUIT
MTS MANUAL TRANSFER SWITCH
MTR MOTOR, MOTORIZED
N.C. NORMALLY CLOSED
NEC NATIONAL ELECTRICAL CODE
NEMA NATIONAL ELECTRICAL
MANUFACTURER'S ASSOCIATION
NFDS NON-FUSED SAFETY DISCONNECT
SWITCH
NIC NOT IN CONTRACT
NL
NIGHT LIGHT
N.O. NORMALLY OPEN
NPF NORMAL POWER FACTOR
NTS NOT TO SCALE
OH OVERHEAD
OL
OVERLOADS
PA
PUBLIC ADDRESS
PB
PULL BOX OR PUSHBUTTON
PE
PNEUMATIC ELECTRIC
PED PEDESTAL
PF
POWER FACTOR
PH
PHASE
PIV POST INDICATING VALVE
PNL PANEL
PP
POWER POLE
PR
PAIR
PRI PRIMARY
PROJ PROJECTION
PRV POWER ROOF VENTILATOR
PT
POTENTIAL TRANSFORMER
PVC POLYVINYL CHLORIDE (CONDUIT)
PWR POWER
QUAN QUANTITY
RCPT RECEPTACLE
REQD REQUIRED
RM ROOM
RSC RIGID STEEL CONDUIT
RTU ROOF TOP UNIT
SABC SMALL APPLICANCE BRANCH
CIRCUIT
SC
SURFACE CONDUIT
SEC SECONDARY
SHT SHEET
SIM SIMILAR
S/N SOLID NEUTRAL
SPEC SPECIFICATION
SPKR SPEAKER
SP
SPARE
SPD SURGE PROTECTION DEVICE
SR
SURFACE RACEWAY
SS
STAINLESS STEEL
SSW SELECTOR SWITCH
S/S STOP/START PUSHBUTTONS
STA STATION
STD STANDARD
SURF SURFACE MOUNTED
SW SWITCH
SWBD SWITCHBOARD
SYM SYMMETRICAL
SYS SYSTEM
TEL TELEPHONE
TEL/DATA TELEPHONE/DATA
TERM TERMINAL
TL
TWIST LOCK
TR
TAMPER RESISTANT
T-STAT THERMOSTAT
TTC TELEPHONE TERMINAL CABINET
TV
TELEVISION
TVTC TELEVISION TERMINAL CABINET
TYP TYPICAL
UC UNDER COUNTER
UE
UNDERGROUND ELECTRICAL
UG UNDERGROUND
UH UNIT HEATER
UNO UNLESS NOTED OTHERWISE
UT
UNDERGROUND TELEPHONE
UTIL UTILITY
UV
ULTRAVIOLET
V
VOLT
VA
VOLT-AMPERES
VDT VIDEO DISPLAY TERMINAL
VERT VERTICAL
VFD VARIABLE FREQUENCY DRIVE
VOL VOLUME
W
WATT
W/
WITH
WG WIRE GUARD
WH WATER HEATER
W/O WITHOUT
WP WEATHERPROOF
XFMR TRANSFORMER
XFR TRANSFER
∠ ANGLE
@ AT
▲ DELTA
' FEET
" INCHES
# NUMBER
Ø PHASE
C CENTER LINE
P PLATE
ELECTRICAL SYMBOL LEGEND
LIGHTING SYMBOLS
POWER SYMBOLS
TELECOM SYMBOLS
LIGHTING FIXTURES, TYPICAL, RECTANGULAR
(VARIOUS SYMBOLS)
FILLED CIRCLES INDICATE RECESSED,
OPEN CIRCLES INDICATE SURFACE-MOUNTED
DIAGONAL LINE INDICATES LENSED
OUTER DOTS INDICATE SUSPENDED
SIMPLEX RECEPTACLE
DUPLEX RECEPTACLE
LIGHTING FIXTURES, TYPICAL, ROUND
CENTER DOT INDICATES PENDANT
DIAGONAL LINE INDICATES LENSED
CHEVRON INDICATES WALL WASH
WALL-MOUNTED FIXTURES, TYPICAL
STRIP FIXTURE
DIRECTIONAL LIGHT, TRACK, FLOOD
LINEAR LIGHT, TAPE LIGHT
EMERGENCY LIGHTING UNIT, CEILING-MOUNTED,
INTEGRAL BATTERY
EMERGENCY LIGHTING UNIT, CEILING-
MOUNTED, REMOTE BATTERY
EMERGENCY LIGHTING UNIT, WALL-
MOUNTED, INTEGRAL BATTERY
EMERGENCY LIGHTING UNIT, WALL-
MOUNTED, REMOTE BATTERY
EXIT LIGHT, CEILING-MOUNTED, SHADING
AND ARROWS INDICATE FACES AND
DIRECTION
EXIT LIGHT, WALL-MOUNTED, SHADING
AND ARROWS INDICATE FACES AND
DIRECTION
EXIT/ELU COMBO
POLE/AREA LIGHTS
POST-TOP AREA LIGHT
BOLLARD LIGHT
DIAGONAL HATCH INDICATES
EMERGENCY LIGHT
OS
VS
OS D
VS D
OS
VS
OS
TC
SINGLE POLE SWITCH
3-WAY SWITCH
4-WAY SWITCH
KEYED SWITCH
LOW VOLTAGE MOMENTARY PUSHBUTTON OR
DECORATOR SWITCH
SWITCH W/PILOT
DIMMER SWITCH
FAN SPEED CONTROLLER. COORDINATE TYPE
WITH FAN MANUFACTURER.
OCCUPANCY SENSOR W/ MANUAL SWITCH
VACANCY SENSOR W/ MANUAL SWITCH
OCCUPANCY SENSOR W/ 0-10V DIMMER
VACANCY SENSOR W/ 0-10V DIMMER
OCCUPANCY SENSOR, CEILING MOUNTED
VACANCY SENSOR, CEILING MOUNTED
CORRIDOR OCCUPANCY SENSOR, CEILING
MOUNTED
TIMER SWITCH
TIME DELAY SWITCH
TIME CONTROL SWITCH
LIGHTING TAGS
TOP VALUE: FIXTURE TYPE ID
S3d
BOTTOM VALUE: LOWERCASE LETTER: SWITCH ID
BOTTOM VALUE: NUMBER(S): CIRCUIT NUMBER
ABSENCE OF A SWITCH ID INDICATES FIXTURE IS CONTROLLED BY THE
ONLY SWITCH IN THE SPACE. AN "nl" IN PLACE OF THE SWITCH ID
INDICATES NIGHT LIGHT (UNSWITCHED).
SWITCH ID INDICATED BY A LOWERCASE LETTER. SWITCH
IDS ARE UNIQUE PER SPACE. A SWITCH WITH AN ID "a"
CONTROLS ALL DEVICES WITHIN THE SPACE IN WHICH IT
IS LOCATED TAGGED WITH "a". A SWITCH WITHOUT A
TAGGED ID CONTROLS ALL LIGHTING FIXTURES WITHIN A
SPACE. ID TAGS MAY BE USED ON CONTROL DEVICES
OTHER THAN SWITCHES, SUCH AS OCCUPANCY SENSORS
OR CONTACTORS.
QUADRUPLEX RECEPTACLE
SPECIAL RECEPTACLE, TYPE AS INDICATED
J J J JUNCTION BOX
RECEPTACLE MODIFIERS:
##": HEIGHT AFF OC
AC: ABOVE COUNTER
WP: WEATHERPROOF IN-USE COVER
W/ WR RATED GFI RECEPTACLE
WPD: WEATHERPROOF NOT-IN-USE COVER
W/ WR RATED GFI RECEPTACLE
IG: ISOLATED GROUND
CENTER SHADING INDICATES GFI
HALF SHADING INDICATES SPLIT
(TYPICALLY SWITCHED)
OUTER SHADING INDICATES EMERGENCY
MULTIOUTLET ASSEMBLY,
FILLED SQUARES INDICATED 120V OUTLETS
RANGE RECEPTACLE, NEMA 14-50R
CORD REEL, DEVICE VARIES
DROP CORD, DEVICE VARIES
FLOORBOX, TYPE AS INDICATED
POKE THRU DEVICE, TYPE AS INDICATED
EPO
EMERGENCY POWER OFF SWITCH
METER
SAFETY SWITCH, NON-FUSED
SAFETY SWITCH, FUSED
MOTOR STARTER
COMBINATION STARTER/DISCONNECT
PUSHBUTTON
MOTOR
GROUND BAR
POWER DEVICE AND EQUIPMENT TAGS
d ELECTRICAL DEVICE TAGS: THE CIRCUIT DESIGNATION IS
INDICATED BY A NUMBER. THE SWITCH DESIGNATION IS
INDICATED BY A LOWER CASE LETTER (WHERE APPLICABLE).
EXAMPLE: SPLIT DUPLEX RECEPTACLE IS CONNECTED TO
CIRCUIT 1 AND ONE RECEPTACLE OUTLET IS CONTROLLED BY
SWITCH "d".
EQUIPMENT TAGS: EQUIPMENT ID IS INDICATED BY AN
UNDERLINED TAG ADJACENT TO THE EQUIPMENT. SEE THE
EQUIPMENT CONNECTION SCHEDULE FOR DESCRIPTION,
XX-1 ELECTRICAL REQUIREMENTS, AND PANEL AND CIRCUIT NUMBER.
SYMBOLS/GRAPHIC APPEARANCE OF EQUIPMENT VARIES.
POWER DISTRIBUTION EQUIPMENT
MDP HP1A LP1A
SB1
HATCHED FILL INDICATES DISTRIBUTION PANEL OR
SWITCHBOARD.
SOLID FILL INDICATES BRANCH PANEL OR LOAD CENTER.
DASHED BOX INDICATES CODE-REQUIRED CLEARANCE (WIDTH
AND DEPTH). DOOR INDICATES FRONT OF RECESSED PANEL.
T1 TRANSFORMER: TYPICALLY TRANSFORMER NAMES BEGIN WITH
OR CONTAIN THE LETTER "T". SEE SINGLE-LINE DIAGRAM FOR
DESCRIPTION AND REQUIREMENTS.
WIRING
CONDUIT SHOWN WITHOUT SLASH MARKS SHALL
CONTAIN 1 # 12 CONDUCTOR PER PHASE, NEUTRAL, AND
GROUND IN 1/2" CONDUIT UNLESS SPECIFIC EQUIPMENT
REQUIRES A DIFFERENT SIZE.
#10
P4N-102
1, 3, 5
CONDUIT SHOWN SHALL CONTAIN 1 # 10 CONDUCTOR
PER PHASE IN ELECTRICAL CODE SIZED MINIMUM
CONDUIT UNLESS A CONDUCTOR AND CONDUIT SIZE IS
SHOWN ADJACENT.
HOME RUN TO BRANCH CIRCUIT PANELBOARD. THE
PANELBOARD DESIGNATION IS SHOWN ADJACENT TO
THE HOME RUN ARROW AS A NUMERATOR AND THE
CIRCUIT DESIGNATION IS SHOWN AS THE DENOMINATOR.
CIRCUIT BREAKER SIZES (AMPS/NUMBER OF POLES) ARE
SHOWN IN THE PANELBOARD SCHEDULE WITH THE
CORRESPONDING PANELBOARD AND CIRCUIT
DESIGNATION. EXAMPLE: HOME RUN TO PANELBOARD
P4N-102; CIRCUITS 1, 3, 5. LONG TICKMARKS INDICATE
NUMBER OF PHASE CONDUCTORS. SHORT TICK MARKS
INDICATE NUMBER OF GROUNDED CONDUCTORS
(NEUTRALS). AN EQUIPMENT GROUNDING CONDUCTOR
IS NOT INDICATED BUT SHALL BE INSTALLED. NUMBER
OF ARROWHEADS INDICATE NUMBER OF CIRCUITS.
CONDUIT IN CEILING, FLOOR OR WALL AS REQUIRED BY
FIELD CONDITIONS
CONDUIT IN FLOOR
DATA OUTLET
VOICE OUTLET
DATA/VOICE OUTLET
WIRELESS ACCESS POINT
CATV OUTLET
SECURITY SYMBOLS
WALL MOUNTED SECURITY CAMERA
CEILING MOUNTED SECURITY CAMERA
CR
CARD READER
CK
CARD READER W/ KEYPAD
DC
DOOR CONTACT
ES
ELECTRIC STRIKE
ML
MAGNETIC LOCK
COMBINATION LOCK
REQUEST TO EXIT BUTTON
MD
MOTION DETECTOR
SECURITY SYSTEM KEYPAD
SOUND SYSTEM SYMBOLS
WALL MOUNTED SPEAKER
S
CEILING MOUNTED SPEAKER
V
VOLUME CONTROL
CONSTRUCTION PHASING
(TYPICAL ALL SYMBOLS AND EQUIPMENT)
(E)
EXISTING TO REMAIN
EXISTING TO BE REMOVED
NEW
EXISTING TO BE DEMOLISHED
MISCELLANEOUS
AREA NOT IN CONTRACT
1
KEY NOTE (SEE SCHEDULE)
-
NUMBER OF DETAIL ON SHEET
---
NUMBER OF SHEET WHERE DETAIL APPEARS
1
Room
6
REVISION NUMBER - SHOWN ON PLANS
ROOM NAME AND NUMBER
SHEET
E000
E101
E201
E202
E301
E302
E303
E304
E401
ELECTRICAL SHEET INDEX
DESCRIPTION
ELECTRICAL TITLE SHEET
COMPOSITE ELECTRICAL DEMOLITION PLAN
COMPOSITE POWER PLAN
COMPOSITE ROOF POWER PLAN
ENLARGED POWER PLAN - ADMIN, MEDIA, & CAFE
ENLARGED POWER PLAN - GYM & WING A
ENLARGED POWER PLAN - WING B & C
ENLARGED POWER PLAN - WING D & E
ELECTRICAL EQUIPMENT SCHEDULES
ELECTRICAL GENERAL NOTES
A THE SYMBOLS AND ABBREVIATIONS SHOWN ON THIS SHEET MAY OR MAY NOT BE
USED IN THIS SET OF DRAWINGS.
B LOW VOLTAGE CABLES OR CONDUCTORS OPERATING AT LESS THAN 50 VOLTS SHALL
BE IN METAL RACEWAY WHERE INSTALLED WITHIN WALLS OR INACCESSIBLE SPACES
OR INSTALLED WHERE EXPOSED AND SUBJECT TO PHYSICAL DAMAGE. LOW
VOLTAGE CABLES MAY BE RUN IN CABLE TRAY. LOW VOLTAGE CABLES MAY BE RUN IN
CABLE SUPPORT HOOKS ABOVE ACCESSIBLE CEILINGS. LOW VOLTAGE CABLES SHALL
BE PLENUM RATED IN PLENUM SPACES.
C COORDINATE LOCATIONS OF DEVICES WITH ARCHITECTURAL ELEVATIONS AND
DETAILS. ARCHITECTURAL ELEVATIONS AND DETAILS TAKE PRECEDENCE OVER
LOCATIONS SHOWN ON ELECTRICAL DRAWINGS.
D PROVIDE CABLE OR CONDUIT AND WIRE AS REQUIRED TO ACHIEVE CIRCUITING
SHOWN. SIZE CONDUCTORS PER NEC AMPACITY AND WIRE FILL CRITERIA. PROVIDE
DEDICATED NEUTRAL AND GROUND CONDUCTORS FOR CIRCUITING ,UNLESS NOTED
OTHERWISE. INCREASE BRANCH CIRCUIT AND/OR FEEDER CONDUCTORS INCLUDING
EQUIPMENT GROUNDING CONDUCTORS PROPORTIONALLY FOR NO MORE THAN 3%
VOLTAGE DROP ON BRANCH CIRCUITS AND 2% ON FEEDERS PER ENERGY CODE.
E IT IS THE RESPONSIBILITY OF THIS CONTRACTOR TO COORDINATE INSTALLATION OF
ELECTRICAL SYSTEMS AND THOSE REQUIRING ELECTRICAL CONNECTIONS TO
MAINTAIN NEC REQUIRED CLEARANCES, INCLUDED BY NOT LIMITED TO AREAS ABOVE
ACCESSIBLE CEILINGS.
F COORDINATE WITH OTHER TRADES FOR PROPER INSTALLATION OF EQUIPMENT.
CONSULT THE DRAWINGS OF OTHER TRADES OR CRAFTS TO AVOID CONFLICTS WITH
EQUIPMENT, ETC. CONFLICTS SHALL BE RESOLVED PRIOR TO ROUGH-IN AND AT NO
ADDITIONAL COST TO THE OWNER.
G LEAVE THE SITE CLEAN AND READY FOR OCCUPANCY. REMOVE DIRT, DEBRIS, EMPTY
CARTONS, TOOLS, CONDUIT AND WIRE SCRAPS AND MISCELLANEOUS SPARE
EQUIPMENT AND MATERIALS USED IN THIS DIVISION OF THE WORK DURING
CONSTRUCTION. COMPONENTS SHALL BE FREE OF DUST, GRIT AND FOREIGN
MATERIALS AND LEFT AS NEW BEFORE FINAL ACCEPTANCE OF WORK.
H CONDUCTORS OPERATING AT 50 VOLTS OR GREATER SHALL BE IN RACEWAY.
RACEWAY WITHIN THE STRUCTURE ABOVE THE FLOOR SLAB SHALL BE METAL.
RACEWAY BELOW THE FLOOR SLAB AND UNDERGROUND RACEWAY OUTSIDE THE
STRUCTURE SHALL BE PVC.
I PERFORM WORK TO COMPLY WITH THE STANDARD PRACTICES FOR GOOD
WORKMANSHIP PUBLISHED BY NATIONAL ELECTRICAL CONTRACTORS ASSOCIATION
(NECA). COMPLY WITH THE LATEST ENFORCED EDITION OF THE NATIONAL
ELECTRICAL CODE (NEC), LOCAL CODES, AMENDMENTS, AND ORDINANCES.
J FIELD COORDINATE FINAL MECHANICAL AND PLUMBING EQUIPMENT LOCATIONS
ALONG WITH CONNECTION REQUIREMENTS AND CONTROL WIRING PRIOR TO
ROUGH-IN. ADJUST CORRESPONDING CIRCUIT BREAKER RATINGS AND BRANCH
CIRCUITING ACCORDINGLY. PROVIDE ADDITIONAL BRANCH CIRCUITS FROM SPARE
CIRCUIT BREAKERS TO ACCOMMODATE ANY CONTROL PANELS AND ACCESSORIES
REQUIRING POWER.
K ELECTRICAL WORK SHALL BE PERFORMED UNDER THE SUPERVISION OF A LICENSED
MASTER ELECTRICIAN. PROCURE PERMITS AND LICENSES AND PAY FEES
ASSOCIATED WITH THIS WORK.
L MATERIALS FURNISHED FOR THIS PROJECT SHALL BE NEW, COMMERCIAL GRADE,
FREE OF DEFECTS, AND LISTED BY A NATIONALLY RECOGNIZED TESTING
LABORATORY UNO.
M PROVIDE COMPLETE OPERATION & MAINTENANCE MANUAL INCLUDING APPROVED
SUBMITTAL DRAWINGS, WARRANTY INFORMATION FOR PRODUCT SUPPLIED,AND
MANUFACTURER'S OPERATION AND MAINTENANCE INSTRUCTIONS.
N THE CONTRACTOR IS RESPONSIBLE FOR MAKING FINAL WIRING TERMINATIONS TO
PRE-INSTALLED RECEPTACLES IN OFFICE FURNITURE. CONTRACTOR IS RESPONSIBLE
FOR WIRING AND INSTALLING VOICE/DATA DEVICES IN OFFICE FURNITURE.
COORDINATE PLACEMENT OF DEVICES WITH FURNITURE LAY-OUT.
O SECURITY SYSTEM TO BE PROVIDED UNDER SEPARATE CONTRACT. IT IS THE
RESPONSIBILITY OF THIS CONTRACTOR TO PROVIDE CONDUIT PROVISIONS, BACK
BOXES, ROUGH-INS, SLEEVES AND POWER TO HEAD END EQUIPMENT FOR EXACT
REQUIREMENTS PRIOR TO START OF WORK.
P CONDUIT AND WIRE SHALL NOT BE INSTALLED BELOW FLOOR SLAB UNLESS
INDICATED ON PLAN BY DASHED CONDUIT.
Q CONTRACTOR SHALL BE RESPONSIBLE FOR WIRING ELECTRICAL ITEMS SHOWN ON
DRAWINGS EXCEPT FOR ITEMS LISTED BELOW. THESE ITEMS SHALL CONSIST OF A
BACK BOX WITH CONDUIT STUBBED ABOVE THE ACCESSIBLE CEILING, SEE STUB UP
DETAIL. VERIFY SIZE OF BACK BOX REQUIRED WITH DEVICE TO BE INSTALLED.
LOCATE BACK BOXES 6" FROM ADJACENT POWER RECEPTACLE INTENDED FOR
COMPUTER USE.
- TV OUTLETS
- VOLUME CONTROLS
- TELEPHONE OUTLETS
- DATA OUTLETS
- FIRE ALARM DEVICES
R FURNISH AND INSTALL CONDUIT FROM BACK BOXES FOR THE FOLLOWING DEVICES
INTO THE ACCESSIBLE CEILING SPACE IN THE CORRIDOR, UNLESS NOTED
OTHERWISE:
- 1"C TV OUTLETS
- 1/2"C VOLUME CONTROLS
- 3/4"C DOOR SECURITY DEVICES (CARD READERS, DOOR STRIKES ETC.)
- 1"C TELEPHONE OUTLETS
- 1"C DATA OUTLETS
- 3/4"C FIRE ALARM DEVICES
ELECTRICAL REMODEL NOTES
A BRANCH CIRCUITING INDICATED ON PLANS AND SCHEDULES IS BASED UPON EXISTING
PLANS AND SITE OBSERVATION, CONTRACTOR TO FIELD VERIFY.
B PROVIDE TYPED CIRCUIT BOARD DIRECTORIES TO REFLECT AS-CONSTRUCTED
CONDITIONS. FIELD VERIFY DURING CONSTRUCTION AND REVISE ACCORDINGLY.
C PROVIDE NECESSARY DEMOLITION TO FACILITATE NEW CONSTRUCTION WORK
ASSOCIATED WITH THIS PROJECT. COORDINATE OUTAGES WITH OWNER MINIMUM 72
HOURS IN ADVANCE. OWNER RETAINS RIGHT TO FIRST SALVAGE. PROVIDE DISPOSAL
OF REMOVED MATERIAL. MAINTAIN CIRCUIT CONTINUITY AS REQUIRED.
D IT IS THE INTENT OF THESE DIAGRAMMATIC DRAWINGS TO PROVIDE THE PROJECT
SCOPE INCLUDING, BUT NOT LIMITED TO PHASED DEMOLITION AND NEW
CONSTRUCTION. EXISTING INFORMATION INDICATED ON THESE PLANS DOES NOT
REPRESENT ALL EXISTING CONDITIONS. THIS CONTRACTOR SHALL BECOME FAMILIAR
WITH EXISTING CONDITIONS, SCOPE OF PHASING, AND PROJECT INTENT PRIOR TO BID
SUBMISSION.
E PROVIDE CUTTING, PATCHING, AND RESTORATION OF FINISHES NECESSARY FOR
WORK SURFACES DAMAGED BY THIS WORK. SPACES AROUND CONDUITS PASSING
THROUGH FLOORS AND WALLS SHALL BE NEATLY PATCHED AND FINISHED TO MATCH
NEW/EXISTING. STRUCTURAL MEMBERS SHALL NOT BE CUT OR PENETRATED IN ANY
MANNER. THE SPACES AROUND THE CONDUITS SHALL BE SEALED TO PREVENT
ENTRANCE OF MOISTURE. PROVIDE FIRE STOPPING PER UL APPROVED METHODS.
F REMOVE ABANDONED WIRING COMPLETE. AT CONTRACTORS OPTION, UTILIZE
EXISTING ABANDONED RACEWAY TO EXTENT AVAILABLE. EXPOSED ABANDONED
RACEWAY SHALL BE REMOVED.
No.
G COORDINATE WORK IN PHASES WITH GENERAL CONTRACTOR AND OWNER TO
FACILITATE DEMOLITION AND NEW CONSTRUCTION.
H REMOVE ELECTRICAL RELATED EQUIPMENT (I.E JUNCTION BOXES, RECEPTACLES,
SWITCHES, DEVICES, ETC... ) AFFECTED/ABANDONED AS A RESULT OF DEMOLITION
AND NEW CONSTRUCTION.
1020 Drayton St., Suite 101
Savannah, GA 31401
(912) 963-1611
www.MethodEG.com
E
O
REGI
RG
STERED
I
No. PE041545
PROFESSIONAL
11/21/25
T
O
ENGINEER
PHER G.
SH
Revision Schedule
Description
Date
ELECTRICAL
TITLE SHEET
Project number
Date
Drawn by
Checked by
2123
NOVEMBER 2025
ELP
CGS
E000