| ABBREVIATIONS LEGEND:
GENERAL NOTES UTILITY NOTES
PROPOSED SITE LEGEND
THESE ABBREVIATIONS MAY BE FOUND IN
1. THE CONTRACTOR SHALL HAVE EXISTING UTILITIES LOCATED PRIOR TO CONSTRUCTION. 1. ALL PUBLIC WATER SUPPLY IMPROVEMENTS SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE
W W WATER LINE CONSTRUCTION DRAWINGS
CONTRACTOR SHALL CALL "OKIE" 1-800-522-6543 IN ADDITION TO DIRECT NOTIFICATION. CURRENT OKLAHOMA DEPARTMENT OF ENVIRONMENTAL QUALITY STANDARD CONSTRUCTION
CONTRACTOR SHALL BRACE UTILITY POLES AS NECESSARY. UTILITIES DAMAGED BY THE SPECIFICATIONS.
A
CONTRACTOR SHALL BE REPAIRED TO THE UTILITY OWNER'S SPECIFICATIONS BY THE GATE VALVE
ADD'L = ADDITIONAL
CONTRACTOR AT NO COST TO THE OWNER. 2. THE CONTRACTOR SHALL PROTECT ALL EXISTING UTILITIES AND SERVICES FROM DAMAGE. UTILITIES
SHALL REMAIN IN SERVICE AT ALL TIMES, AND ANY DISRUPTION OF SERVICE SHALL BE AT THE
FIRE HYDRANT B
2. THE CONTRACTOR SHALL ESTABLISH, INSTALL, OPERATE, AND MAINTAIN COMPLETE AND CONTRACTOR'S SOLE EXPENSE.
BC = BACK OF CURB
ADEQUATE AND SAFE TRAFFIC CONTROLS DURING THE ENTIRE CONSTRUCTION PERIOD. ALL
SLICK BORE BM = BENCH MARK
TRAFFIC CONTROL DEVICES SHALL BE APPROVED BY THE ENGINEER. 3. CONTRACTOR SHALL VERIFY PROPOSED WATER LINE ELEVATIONS TO INSURE NO CONFLICTS WITH
BW = BOTTOM OF WALL
EXISTING OR PROPOSED UTILITIES. MINOR FIELD ADJUSTMENTS NECESSARY TO AVOID CONFLICTS SHALL
3. ALL DIMENSIONS OR ELEVATIONS WITH SHALL BE CONFIRMED BY THE CONTRACTOR. BE COORDINATED WITH THE APPROVAL OF THE ENGINEER.
C
C/C = CENTER TO CENTER
4. ALL DIMENSIONS OF EXISTING STRUCTURES AND EQUIPMENT SHALL BE VERIFIED BY THE 4. CONTRACTOR SHALL VERIFY EXISTING PIPE SIZE, TYPE AND LOCATION PRIOR TO ORDERING MATERIALS,
CET = CULVERT END TREATMENT
CONTRACTOR. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER & TO INSURE PROPER CONNECTION.
CGMP = CORRUGATED GALVANIZED METAL PIPE
OWNER.
EXISTING LEGEND CL = CENTER LINE
5. ALL BURIED FITTINGS, SUCH AS BENDS, TEES, ETC., SHALL BE BLOCKED FOR THRUST, AS SHOWN ON THE
CMU = CONCRETE MASONRY UNIT
5. TOPSOIL IN THE DISTURBED AREAS SHALL BE REMOVED AND STOCKPILED ON SITE IN STANDARD DETAIL DRAWING. THIS REQUIREMENT SHALL INCLUDE ALL PRESSURE PIPING AND LOW HEAD
CONC. = CONCRETE
ACCORDANCE WITH THE PROJECT SPECIFICATIONS. ALL EXCESS TOPSOIL SHALL BE CONSIDERED (GRAVITY) PIPING. COST SHALL BE INCLUDED IN OTHER ITEMS OF WORK.
CONSTR= CONSTRUCT
WASTE AND STOCKPILED ON-SITE BY THE CONTRACTOR, UNLESS OTHERWISE NOTED. EXISTING FENCE
CTRS = CENTERS
6. MINIMUM DEPTH OF COVER SHALL BE 36-INCHES UNLESS OTHERWISE NOTED.
6. ALL DISTURBED ROADWAY AND DRIVEWAY SURFACES SHALL BE RESTORED TO THEIR
OVER HEAD POWER LINE D
PRE-CONSTRUCTION CONDITION. 7. NO. 12 COPPER WIRE ( TRACER WIRE ) AND MYLAR DETECTABLE MARKING TAPE SHALL BE BURIED ABOVE
DIA. = DIAMETER
THE TOP OF ALL LINES.
7. FALL PROTECTION AROUND ALL OPENINGS AND EXCAVATION SHALL BE MAINTAINED AT ALL TIMES. STORM DRAIN PIPE
E
8. WATER LINE SHALL BE PRESSURE & LEAK TESTED IN ACCORDANCE WITH SPECIFICATIONS.
E: = EASTING
8. NORTH ARROWS SHOWN ON DRAWINGS INDICATE LOCAL COORDINATE SYSTEM ESTABLISHED BY
WATER LINE EC: = EDGE OF CONCRETE
THE SURVEYOR, UNLESS OTHERWISE NOTED. 9. DISINFECTION: ALL NEW WATER LINES, VALVES AND FIRE HYDRANTS SHALL BE DISINFECTED IN
EG: = EDGE OF GRAVEL
ACCORDANCE WITH AWWA C651. METHODS DESCRIBED IN SEC. 5.1 (TABLET METHOD) OR 5.2
EL = PROPOSED ELEVATION
9. TRENCH SAFETY AND SHORING IN ACCORDANCE WITH CURRENT OSHA REGULATIONS SHALL BE (CONTINUOUS FEED METHOD) SHALL BE USED FOR DISINFECTION. THE CONTRACTOR SHALL COMMUNICATION LINE
EX. = EXISTING
EMPLOYED BY CONTRACTOR AT ALL TIMES. COLLECT SAFE BACTERIAL SAMPLES IN TWO CONSECUTIVE DAYS PRIOR TO PLACING THE WATERLINE INTO
SERVICE. SIGN
10. IF AT ANY POINT CONSTRUCTION ACTIVITIES EXPOSE ARCHEOLOGICAL MATERIALS SUCH AS
F
CHIPPED STONE, TOOLS, POTTERY, BONE, HISTORIC CROCKERY, GLASS, METAL ITEMS OR 10. DEFLECTION OF WATER LINE SHALL NOT EXCEED MANUFACTURERS RECOMMENDATION. WATER VALVE
FC = FACE OF CURB
BUILDING MATERIALS, THE OKLAHOMA ARCHEOLOGICAL SURVEY STATE ARCHEOLOGIST, KARY L.
FIRE HYDRANT FF = FINISH FLOOR ELEVATION
STACKELBECK, SHALL BE CONTACTED IMMEDIATELY AT 405-325-7211. 11. SEPARATION OF WATER MAINS AND SEWERS FROM CONTAMINATION SOURCES.
FL: = FLOW LINE
(1) HORIZONTAL SEPARATION. WM WATER METER
FT. = FOOT
11. ALL STATIONS SHOWN ON THE PLANS ARE CENTERLINE STATIONS UNLESS NOTED OTHERWISE. (A) MEASURE THE SEPARATION DISTANCE EDGE TO EDGE.
(B) LOCATE WATER MAINS AT LEAST 10 FEET HORIZONTALLY FROM ANY EXISTING OR PROPOSED TELEPHONE PEDESTAL
G
12. DIMENSIONS SHOWN ARE TO BACK OF CURB OR CENTERLINE OF PIPE UNLESS NOTED OTHERWISE. SEWER LINES.
LIGHT POLE GA. = GAUGE
DIMENSIONS TO BUILDING ARE TO EDGE OF FOUNDATION. (C) LOCATE WATER MAINS AT LEAST 5 FEET HORIZONTALLY FROM ANY EXISTING OR PROPOSED STORM
SEWERS, RAW WATER LINES, PETROLEUM PRODUCT LINES, NATURAL GAS LINES, AND OTHER
POWER POLE H
13. PERMANENT EROSION CONTROL SHALL BE AS INDICTED ON CONSTRUCTION DOCUMENTS OR BURIED UTILITY LINES.
HIGH PT.= HIGH POINT
DIRECTED BY OWNER. ALL AREAS DISTURBED BY CONSTRUCTION SHALL BE RE-ESTABLISHED WITH (D) LOCATE CAST IRON WATER LINES AT LEAST 10 FEET FROM GASOLINE STORAGE TANK AND LINES AND GM GAS METER
VEGETATIVE COVER. LACKING DIRECTION BY OWNER, CONTRACTOR SHALL ASSUME DISTURBED PVC WATER LINES AT LEAST 50 FEET HORIZONTALLY FROM ANY GASOLINE STORAGE TANKS OR
I
AREAS ARE TO BE SODDED. LINES. AC UNIT
I.D. = INNER DIAMETER
(E) LOCATE WATER LINES AT LEAST 15 FEET FROM ALL PARTS OF SEPTIC TANKS AND ABSORPTION
FIELDS, OR OTHER SEWAGE TREATMENT AND DISPOSAL SYSTEMS.
L
(2) VERTICAL SEPARATION.
LA = LENGTH OF RIP RAP APRON
(A) MEASURE THE SEPARATION DISTANCE FROM EDGE TO EDGE.
L.F. = LINEAR FOOT
(B) LAY WATERLINES CROSSING SEWER LINES TO PROVIDE A MINIMUM VERTICAL DISTANCE OF 24
LP = LENGTH OF FLUME
INCHES BETWEEN THE WATER MAINS AND THE SEWER LINE. ARRANGE THE PIPING SO THE
JOINTS IN A 20 FOOT LENGTH OF PVC OR 18-FOOT LENGTH OF CAST IRON SEWER PIPE WILL BE
M
EQUIDISTANT FROM THE WATER MAIN. WHERE A WATER MAIN CROSSES UNDER A SEWER ,
MAX. = MAXIMUM
PROVIDE ADEQUATE STRUCTURAL SUPPORT FOR SEWER TO PREVENT DAMAGE TO THE WATER
EROSION CONTROL NOTES: MD: = MEASURED DEPTH
MAIN.
MECH. = MECHANICAL
(C) MAINTAIN A 2-FOOT VERTICAL SEPARATION BETWEEN WATER LINES AND ANY EXISTING OR
1. SILT FENCE SHALL BE MAINTAINED AND SEDIMENT BUILDUP REGULARLY REMOVED UNTIL PAVING ME EL = MATCH EXISTING ELEVATION
PROPOSED STORM SEWERS, RAW WATERLINES, PETROLEUM PRODUCT LINES , NATURAL GAS
OPERATIONS ARE COMPLETE AND/OR SEEDING IS IN PLACE AND 75% VEGETATION STABILIZATION IS MIN. = MINIMUM
LINES, AND OTHER BURIED UTILITY LINES.
OBTAINED.
N
12. THE PLANS HAVE BEEN PREPARED TO SHOW THE APPROXIMATE LOCATION OF EXISTING KNOWN UTILITIES.
2. ALL TREES, BRUSH, AND OTHER DEBRIS THAT MIGHT INTERFERE WITH THE FLOW OF WATER IS TO N: = NORTHING
THE CONTRACTOR SHALL CONTACT OKIE, EACH RESPECTIVE UTILITY COMPANY AND THE PROJECT OWNER
BE CLEANED OUT TO THE RIGHT-OF-WAY LINE AT EACH STRUCTURE, IN A MANNER APPROVED BY MIN.T.S. = NOT TO SCALE
TO DETERMINE THE EXACT LOCATION OF UNDERGROUND UTILITIES PRIOR TO EXCAVATION. ANY CHANGE
THE ENGINEER.
IN ALIGNMENT OR GRADE CAUSED BY INTERFERING UTILITIES SHALL BE MADE BY THE CONTRACTOR AT NO
O
COST TO THE OWNER AND THE ENGINEER NOTIFIED.
3. ALL FLOW LINES THAT ARE TO BE FILLED SHALL BE THOROUGHLY COMPACTED TO 95% STANDARD O.C. = ON CENTER
PROCTOR DENSITY BEFORE CONSTRUCTION OR EXTENSION OF DRAINAGE STRUCTURES. O.C.E.W.= ON CENTER EACH WAY
13. DEPTHS OF ANY EXISTING UTILITIES SHOWN ON THE PLANS ARE APPROXIMATE. CONTRACTOR SHALL AT
HIS OWN EXPENSE UNCOVER AND VERIFY THE LOCATION AND ELEVATION OF EXISTING UTILITIES IN
4. IN ORDER TO ALLEVIATE DUST CONDITIONS DURING GRADING OPERATIONS, AND AFTER GRADING P
ADVANCE OF THE CONSTRUCTION.
OPERATIONS ARE COMPLETED, BUT BEFORE PAVEMENT AND/OR PERMANENT EROSION CONTROL P.C.C. = PORTLAND CEMENT
WORK IS COMPLETED, THE CONTRACTOR SHALL SPRINKLE GRADING AT INTERVALS APPROVED BY CONCRETE
14. THE CONTRACTOR SHALL PROVIDE ANY TAPS, CROSS-OVERS, VALVES, ETC. AS REQUIRED TO FLUSH,
THE OWNERS REPRESENTATIVE. PCES = PREFABRICATED CULVERT
HYDROSTATIC TEST AND DISINFECT ALL NEW LINES PRIOR TO BEING PLACED IN SERVICE.
END SECTION
5. AT THE BEGINNING OF THE TURF OPERATIONS, ANY AREAS INCLUDED IN PLANNED QUANTITIES
15. CONTRACTOR SHALL COORDINATE ANY ACTIVITIES INVOLVING WATER & SANITARY SEWER SYSTEM WITH
THAT HAVE GROWN A SATISFACTORY VOLUNTEER TURF OF PERENNIAL GRASS AS DETERMINED BY R
UTILITY AND OWNER'S REPRESENTATIVE. CONTRACTOR SHALL CONTACT UTILITY TO COORDINATE
THE OWNER'S REPRESENTATIVE, SHALL BE FERTILIZED AND WATERED BUT SHALL NOT BE SEEDED, R = RADIUS
RELOCATION OR REPLACEMENT OF EXISTING WATER METER TO A LOCATION TO CLEAR CONSTRUCTION.
SODDED OR SPRIGGED. RE: = REFERENCE
REQ'D = REQUIRED
16. CONTRACTOR SHALL PROVIDE OR OTHERWISE PAY ANY BUILDING PERMITS, TAP//METER FEES,
6. VEGETATIVE MULCH AND SEEDING SHALL BE UTILIZED FOR TEMPORARY EROSION CONTROL. R.O.W. = RIGHTS OF WAY
CONNECTION FEES ETC. CONTRACTOR SHALL COORDINATE WITH RESPECTIVE UTILITY TO DETERMINE
ANY SPECIFIC REQUIREMENTS.
7. SEED: THE FOLLOWING KINDS OF SEEDS, AT ACRES-RATES INDICATED BELOW, SHALL BE PLANTED S
ON THE AREAS DESIGNATED FOR SEEDING. S.F. = SQUARE FOOT
MATERIALS NOTES SL. = SLOPE
TEMPORARY SEEDING SQ. = SQUARE
1. ALL NEW PUBLIC WATER LINE PIPING SHALL BE AWWA C900, DR18 PVC OR ASTM D3035 DR11
KINDS OF SEED TO BE FURNISHED QUANTITY PER ACRE SSMH = SANITARY SEWER MANHOLE
HDPE (SLICK BORE ONLY) OR APPROVED EQUAL.
COOL SEASON MIX- STA. = STATION
PERENNIAL RYEGRASS (LOLIUM PERENNE) 8 LBS. OF SEED
2. ALL FITTINGS (TEES, BENDS, VALVES, ETC.) SHALL BE DUCTILE IRON MECHANICAL JOINTS
T
(MJ) AND RESTRAINED (RJ). RESTRAINTS SHALL BE "MIDCO" AS MANUFACTURED BY
WARM SEASON MIX- T = TANGENT
MIDLAND MANUFACTURING COMPANY OR APPROVED EQUAL. THRUST BLOCKING SHALL
KOREAN LESPEDEZA (LESPEDEZA STRIATA) 12 LBS. OF SEED TC = TOP OF CURB ELEVATION
ALSO BE REQUIRED. ALL FITTINGS TO BE POLY WRAPPED.
LITTLE BLUESTEM (ANDROPOGON SCOPARIUS) 12 LBS. OF SEED TF = TOP OF FOOTING
TR: = TOP OF RIM
3. TAPPING SLEEVES SHALL BE SMITH-BLAIR 665 STAINLESS STEEL OR EQUAL. 200PSI.
VEGETATIVE MULCHING: THE VEGETATIVE MULCH SHALL BE ANCHORED IN ACCORDANCE WITH THE TW = TOP OF WALL
"ADHESIVE SPRAY METHOD", AS SPECIFIED IN 233.04(b) OF THE ODOT STANDARD SPECIFICATIONS. TYP. = TYPICAL
SEASONAL PLANTING RESTRICTIONS W
THE PLANTING OF SPRIGGING SHALL BE RESTRICTED TO THE PERIOD FROM APRIL 1ST TO JUNE 30TH. W/ = WITH
W.W.F. = WELDED WIRE FABRIC
THE PLANTING OF TEMPORARY SEEDS (COOL SEASON MIX) SHALL BE RESTRICTED TO THE PERIOD
FROM SEPTEMBER 1ST TO NOVEMBER 15TH. Z
Z: = ELEVATION
THE PLANTING OF TEMPORARY SEEDS (WARM SEASON MIX) SHALL BE RESTRICTED TO THE PERIOD
FROM MARCH 15TH TO JUNE 30TH. SYMBOLS
& = AND
AREAS ON WHICH SALVAGED TOPSOIL IS TO BE REPLACED SHALL HAVE 0-46-0 FERTILIZER APPLIED, AT = DIAMETER
THE RATE OF 150 LBS. PER ACRE, JUST PRIOR TO THE REPLACEMENT OF SALVAGED TOPSOIL. @ = AT
= DELTA
= CENTER LINE |
Barker & Associates, Inc.
3902 University Blvd.
Durant, OK 74701
580.931.9045
OK. CA. 3998
EXP. 06/30/2026 |
|
|
CHECKED BY: H. WAYNE BARKER, P.E. |
|
|
PROFESSIONAL SEAL: |
|
|
|
|
|
DOWNTOWN
EXECUTIVE
AIRPARK
WL EXTENSION
CITY OF ARDMORE
ARDMORE, OKLAHOMA |
|
|
|
|
|
DESIGNED BY:
JBA/HWB |
|
|
DRAWN BY:
JBA/JCD |
|
|
RECORD OF REVISIONS |
|
|
No. DATE DESCRIPTION |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
GENERAL NOTES |
|
|
PROJECT NUMBER |
|
|
11058 |
|
|
STATE |
COUNTY |
|
OKLAHOMA |
CARTER |
|
SHEET NUMBER |
DATE |
|
C002 |
APR 2026 |
ABBREVIATIONS LEGEND:
GENERAL NOTES UTILITY NOTES
PROPOSED SITE LEGEND
THESE ABBREVIATIONS MAY BE FOUND IN
1. THE CONTRACTOR SHALL HAVE EXISTING UTILITIES LOCATED PRIOR TO CONSTRUCTION. 1. ALL PUBLIC WATER SUPPLY IMPROVEMENTS SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE
W W WATER LINE CONSTRUCTION DRAWINGS
CONTRACTOR SHALL CALL "OKIE" 1-800-522-6543 IN ADDITION TO DIRECT NOTIFICATION. CURRENT OKLAHOMA DEPARTMENT OF ENVIRONMENTAL QUALITY STANDARD CONSTRUCTION
CONTRACTOR SHALL BRACE UTILITY POLES AS NECESSARY. UTILITIES DAMAGED BY THE SPECIFICATIONS.
A
CONTRACTOR SHALL BE REPAIRED TO THE UTILITY OWNER'S SPECIFICATIONS BY THE GATE VALVE
ADD'L = ADDITIONAL
CONTRACTOR AT NO COST TO THE OWNER. 2. THE CONTRACTOR SHALL PROTECT ALL EXISTING UTILITIES AND SERVICES FROM DAMAGE. UTILITIES
SHALL REMAIN IN SERVICE AT ALL TIMES, AND ANY DISRUPTION OF SERVICE SHALL BE AT THE
FIRE HYDRANT B
2. THE CONTRACTOR SHALL ESTABLISH, INSTALL, OPERATE, AND MAINTAIN COMPLETE AND CONTRACTOR'S SOLE EXPENSE.
BC = BACK OF CURB
ADEQUATE AND SAFE TRAFFIC CONTROLS DURING THE ENTIRE CONSTRUCTION PERIOD. ALL
SLICK BORE BM = BENCH MARK
TRAFFIC CONTROL DEVICES SHALL BE APPROVED BY THE ENGINEER. 3. CONTRACTOR SHALL VERIFY PROPOSED WATER LINE ELEVATIONS TO INSURE NO CONFLICTS WITH
BW = BOTTOM OF WALL
EXISTING OR PROPOSED UTILITIES. MINOR FIELD ADJUSTMENTS NECESSARY TO AVOID CONFLICTS SHALL
Barker & Associates, Inc.
3. ALL DIMENSIONS OR ELEVATIONS WITH SHALL BE CONFIRMED BY THE CONTRACTOR. BE COORDINATED WITH THE APPROVAL OF THE ENGINEER.
C 3902 University Blvd.
C/C = CENTER TO CENTER
4. ALL DIMENSIONS OF EXISTING STRUCTURES AND EQUIPMENT SHALL BE VERIFIED BY THE 4. CONTRACTOR SHALL VERIFY EXISTING PIPE SIZE, TYPE AND LOCATION PRIOR TO ORDERING MATERIALS, Durant, OK 74701
CET = CULVERT END TREATMENT
CONTRACTOR. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER & TO INSURE PROPER CONNECTION. 580.931.9045
CGMP = CORRUGATED GALVANIZED METAL PIPE
OWNER. OK. CA. 3998
EXISTING LEGEND CL = CENTER LINE
5. ALL BURIED FITTINGS, SUCH AS BENDS, TEES, ETC., SHALL BE BLOCKED FOR THRUST, AS SHOWN ON THE EXP. 06/30/2026
CMU = CONCRETE MASONRY UNIT
5. TOPSOIL IN THE DISTURBED AREAS SHALL BE REMOVED AND STOCKPILED ON SITE IN STANDARD DETAIL DRAWING. THIS REQUIREMENT SHALL INCLUDE ALL PRESSURE PIPING AND LOW HEAD
CONC. = CONCRETE
ACCORDANCE WITH THE PROJECT SPECIFICATIONS. ALL EXCESS TOPSOIL SHALL BE CONSIDERED (GRAVITY) PIPING. COST SHALL BE INCLUDED IN OTHER ITEMS OF WORK. CHECKED BY: H. WAYNE BARKER, P.E.
CONSTR= CONSTRUCT
WASTE AND STOCKPILED ON-SITE BY THE CONTRACTOR, UNLESS OTHERWISE NOTED. EXISTING FENCE
CTRS = CENTERS PROFESSIONAL SEAL:
6. MINIMUM DEPTH OF COVER SHALL BE 36-INCHES UNLESS OTHERWISE NOTED.
6. ALL DISTURBED ROADWAY AND DRIVEWAY SURFACES SHALL BE RESTORED TO THEIR
OVER HEAD POWER LINE D
PRE-CONSTRUCTION CONDITION. 7. NO. 12 COPPER WIRE ( TRACER WIRE ) AND MYLAR DETECTABLE MARKING TAPE SHALL BE BURIED ABOVE
DIA. = DIAMETER
THE TOP OF ALL LINES.
7. FALL PROTECTION AROUND ALL OPENINGS AND EXCAVATION SHALL BE MAINTAINED AT ALL TIMES. STORM DRAIN PIPE
E
8. WATER LINE SHALL BE PRESSURE & LEAK TESTED IN ACCORDANCE WITH SPECIFICATIONS.
E: = EASTING
8. NORTH ARROWS SHOWN ON DRAWINGS INDICATE LOCAL COORDINATE SYSTEM ESTABLISHED BY
WATER LINE EC: = EDGE OF CONCRETE
THE SURVEYOR, UNLESS OTHERWISE NOTED. 9. DISINFECTION: ALL NEW WATER LINES, VALVES AND FIRE HYDRANTS SHALL BE DISINFECTED IN
EG: = EDGE OF GRAVEL
ACCORDANCE WITH AWWA C651. METHODS DESCRIBED IN SEC. 5.1 (TABLET METHOD) OR 5.2
EL = PROPOSED ELEVATION
9. TRENCH SAFETY AND SHORING IN ACCORDANCE WITH CURRENT OSHA REGULATIONS SHALL BE (CONTINUOUS FEED METHOD) SHALL BE USED FOR DISINFECTION. THE CONTRACTOR SHALL COMMUNICATION LINE
EX. = EXISTING
EMPLOYED BY CONTRACTOR AT ALL TIMES. COLLECT SAFE BACTERIAL SAMPLES IN TWO CONSECUTIVE DAYS PRIOR TO PLACING THE WATERLINE INTO
SERVICE. SIGN
10. IF AT ANY POINT CONSTRUCTION ACTIVITIES EXPOSE ARCHEOLOGICAL MATERIALS SUCH AS
F
CHIPPED STONE, TOOLS, POTTERY, BONE, HISTORIC CROCKERY, GLASS, METAL ITEMS OR 10. DEFLECTION OF WATER LINE SHALL NOT EXCEED MANUFACTURERS RECOMMENDATION. WATER VALVE
FC = FACE OF CURB
BUILDING MATERIALS, THE OKLAHOMA ARCHEOLOGICAL SURVEY STATE ARCHEOLOGIST, KARY L.
FIRE HYDRANT FF = FINISH FLOOR ELEVATION
STACKELBECK, SHALL BE CONTACTED IMMEDIATELY AT 405-325-7211. 11. SEPARATION OF WATER MAINS AND SEWERS FROM CONTAMINATION SOURCES.
FL: = FLOW LINE
(1) HORIZONTAL SEPARATION. WM WATER METER
FT. = FOOT
11. ALL STATIONS SHOWN ON THE PLANS ARE CENTERLINE STATIONS UNLESS NOTED OTHERWISE. (A) MEASURE THE SEPARATION DISTANCE EDGE TO EDGE.
DOWNTOWN
(B) LOCATE WATER MAINS AT LEAST 10 FEET HORIZONTALLY FROM ANY EXISTING OR PROPOSED TELEPHONE PEDESTAL
G
12. DIMENSIONS SHOWN ARE TO BACK OF CURB OR CENTERLINE OF PIPE UNLESS NOTED OTHERWISE. SEWER LINES.
DIMENSIONS TO BUILDING ARE TO EDGE OF FOUNDATION. (C) LOCATE WATER MAINS AT LEAST 5 FEET HORIZONTALLY FROM ANY EXISTING OR PROPOSED STORM LIGHT POLE GA. = GAUGE EXECUTIVE
SEWERS, RAW WATER LINES, PETROLEUM PRODUCT LINES, NATURAL GAS LINES, AND OTHER
POWER POLE H
13. PERMANENT EROSION CONTROL SHALL BE AS INDICTED ON CONSTRUCTION DOCUMENTS OR BURIED UTILITY LINES.
AIRPARK
HIGH PT.= HIGH POINT
DIRECTED BY OWNER. ALL AREAS DISTURBED BY CONSTRUCTION SHALL BE RE-ESTABLISHED WITH (D) LOCATE CAST IRON WATER LINES AT LEAST 10 FEET FROM GASOLINE STORAGE TANK AND LINES AND GM GAS METER
VEGETATIVE COVER. LACKING DIRECTION BY OWNER, CONTRACTOR SHALL ASSUME DISTURBED PVC WATER LINES AT LEAST 50 FEET HORIZONTALLY FROM ANY GASOLINE STORAGE TANKS OR
I WL EXTENSION
AREAS ARE TO BE SODDED. LINES. AC UNIT
I.D. = INNER DIAMETER
(E) LOCATE WATER LINES AT LEAST 15 FEET FROM ALL PARTS OF SEPTIC TANKS AND ABSORPTION
FIELDS, OR OTHER SEWAGE TREATMENT AND DISPOSAL SYSTEMS.
L
(2) VERTICAL SEPARATION.
LA = LENGTH OF RIP RAP APRON
(A) MEASURE THE SEPARATION DISTANCE FROM EDGE TO EDGE.
L.F. = LINEAR FOOT CITY OF ARDMORE
(B) LAY WATERLINES CROSSING SEWER LINES TO PROVIDE A MINIMUM VERTICAL DISTANCE OF 24
LP = LENGTH OF FLUME
INCHES BETWEEN THE WATER MAINS AND THE SEWER LINE. ARRANGE THE PIPING SO THE
JOINTS IN A 20 FOOT LENGTH OF PVC OR 18-FOOT LENGTH OF CAST IRON SEWER PIPE WILL BE
M
EQUIDISTANT FROM THE WATER MAIN. WHERE A WATER MAIN CROSSES UNDER A SEWER ,
MAX. = MAXIMUM
PROVIDE ADEQUATE STRUCTURAL SUPPORT FOR SEWER TO PREVENT DAMAGE TO THE WATER
EROSION CONTROL NOTES: MD: = MEASURED DEPTH
MAIN.
MECH. = MECHANICAL ARDMORE, OKLAHOMA
(C) MAINTAIN A 2-FOOT VERTICAL SEPARATION BETWEEN WATER LINES AND ANY EXISTING OR
1. SILT FENCE SHALL BE MAINTAINED AND SEDIMENT BUILDUP REGULARLY REMOVED UNTIL PAVING ME EL = MATCH EXISTING ELEVATION
PROPOSED STORM SEWERS, RAW WATERLINES, PETROLEUM PRODUCT LINES , NATURAL GAS
OPERATIONS ARE COMPLETE AND/OR SEEDING IS IN PLACE AND 75% VEGETATION STABILIZATION IS MIN. = MINIMUM
LINES, AND OTHER BURIED UTILITY LINES.
OBTAINED.
N
12. THE PLANS HAVE BEEN PREPARED TO SHOW THE APPROXIMATE LOCATION OF EXISTING KNOWN UTILITIES.
2. ALL TREES, BRUSH, AND OTHER DEBRIS THAT MIGHT INTERFERE WITH THE FLOW OF WATER IS TO N: = NORTHING
THE CONTRACTOR SHALL CONTACT OKIE, EACH RESPECTIVE UTILITY COMPANY AND THE PROJECT OWNER
BE CLEANED OUT TO THE RIGHT-OF-WAY LINE AT EACH STRUCTURE, IN A MANNER APPROVED BY MIN.T.S. = NOT TO SCALE
TO DETERMINE THE EXACT LOCATION OF UNDERGROUND UTILITIES PRIOR TO EXCAVATION. ANY CHANGE
THE ENGINEER.
IN ALIGNMENT OR GRADE CAUSED BY INTERFERING UTILITIES SHALL BE MADE BY THE CONTRACTOR AT NO
O
COST TO THE OWNER AND THE ENGINEER NOTIFIED.
3. ALL FLOW LINES THAT ARE TO BE FILLED SHALL BE THOROUGHLY COMPACTED TO 95% STANDARD O.C. = ON CENTER
PROCTOR DENSITY BEFORE CONSTRUCTION OR EXTENSION OF DRAINAGE STRUCTURES. O.C.E.W.= ON CENTER EACH WAY
13. DEPTHS OF ANY EXISTING UTILITIES SHOWN ON THE PLANS ARE APPROXIMATE. CONTRACTOR SHALL AT
HIS OWN EXPENSE UNCOVER AND VERIFY THE LOCATION AND ELEVATION OF EXISTING UTILITIES IN
4. IN ORDER TO ALLEVIATE DUST CONDITIONS DURING GRADING OPERATIONS, AND AFTER GRADING P
ADVANCE OF THE CONSTRUCTION.
OPERATIONS ARE COMPLETED, BUT BEFORE PAVEMENT AND/OR PERMANENT EROSION CONTROL P.C.C. = PORTLAND CEMENT
WORK IS COMPLETED, THE CONTRACTOR SHALL SPRINKLE GRADING AT INTERVALS APPROVED BY CONCRETE
14. THE CONTRACTOR SHALL PROVIDE ANY TAPS, CROSS-OVERS, VALVES, ETC. AS REQUIRED TO FLUSH,
THE OWNERS REPRESENTATIVE. PCES = PREFABRICATED CULVERT
HYDROSTATIC TEST AND DISINFECT ALL NEW LINES PRIOR TO BEING PLACED IN SERVICE.
END SECTION
5. AT THE BEGINNING OF THE TURF OPERATIONS, ANY AREAS INCLUDED IN PLANNED QUANTITIES
15. CONTRACTOR SHALL COORDINATE ANY ACTIVITIES INVOLVING WATER & SANITARY SEWER SYSTEM WITH
THAT HAVE GROWN A SATISFACTORY VOLUNTEER TURF OF PERENNIAL GRASS AS DETERMINED BY R
UTILITY AND OWNER'S REPRESENTATIVE. CONTRACTOR SHALL CONTACT UTILITY TO COORDINATE
THE OWNER'S REPRESENTATIVE, SHALL BE FERTILIZED AND WATERED BUT SHALL NOT BE SEEDED, R = RADIUS
RELOCATION OR REPLACEMENT OF EXISTING WATER METER TO A LOCATION TO CLEAR CONSTRUCTION.
SODDED OR SPRIGGED. RE: = REFERENCE
REQ'D = REQUIRED
16. CONTRACTOR SHALL PROVIDE OR OTHERWISE PAY ANY BUILDING PERMITS, TAP//METER FEES,
6. VEGETATIVE MULCH AND SEEDING SHALL BE UTILIZED FOR TEMPORARY EROSION CONTROL. R.O.W. = RIGHTS OF WAY
CONNECTION FEES ETC. CONTRACTOR SHALL COORDINATE WITH RESPECTIVE UTILITY TO DETERMINE
7. SEED: THE FOLLOWING KINDS OF SEEDS, AT ACRES-RATES INDICATED BELOW, SHALL BE PLANTED ANY SPECIFIC REQUIREMENTS. S DESIGNED BY: JBA/HWB
ON THE AREAS DESIGNATED FOR SEEDING. S.F. = SQUARE FOOT DRAWN BY:
JBA/JCD
MATERIALS NOTES SL. = SLOPE
TEMPORARY SEEDING SQ. = SQUARE
1. ALL NEW PUBLIC WATER LINE PIPING SHALL BE AWWA C900, DR18 PVC OR ASTM D3035 DR11
KINDS OF SEED TO BE FURNISHED QUANTITY PER ACRE SSMH = SANITARY SEWER MANHOLE RECORD OF REVISIONS
HDPE (SLICK BORE ONLY) OR APPROVED EQUAL.
COOL SEASON MIX- STA. = STATION
No. DATE DESCRIPTION
PERENNIAL RYEGRASS (LOLIUM PERENNE) 8 LBS. OF SEED
2. ALL FITTINGS (TEES, BENDS, VALVES, ETC.) SHALL BE DUCTILE IRON MECHANICAL JOINTS
T
(MJ) AND RESTRAINED (RJ). RESTRAINTS SHALL BE "MIDCO" AS MANUFACTURED BY
WARM SEASON MIX- T = TANGENT
MIDLAND MANUFACTURING COMPANY OR APPROVED EQUAL. THRUST BLOCKING SHALL
KOREAN LESPEDEZA (LESPEDEZA STRIATA) 12 LBS. OF SEED TC = TOP OF CURB ELEVATION
ALSO BE REQUIRED. ALL FITTINGS TO BE POLY WRAPPED.
LITTLE BLUESTEM (ANDROPOGON SCOPARIUS) 12 LBS. OF SEED TF = TOP OF FOOTING
TR: = TOP OF RIM
3. TAPPING SLEEVES SHALL BE SMITH-BLAIR 665 STAINLESS STEEL OR EQUAL. 200PSI.
VEGETATIVE MULCHING: THE VEGETATIVE MULCH SHALL BE ANCHORED IN ACCORDANCE WITH THE TW = TOP OF WALL
"ADHESIVE SPRAY METHOD", AS SPECIFIED IN 233.04(b) OF THE ODOT STANDARD SPECIFICATIONS. TYP. = TYPICAL
SEASONAL PLANTING RESTRICTIONS W
THE PLANTING OF SPRIGGING SHALL BE RESTRICTED TO THE PERIOD FROM APRIL 1ST TO JUNE 30TH. W/ = WITH
W.W.F. = WELDED WIRE FABRIC
THE PLANTING OF TEMPORARY SEEDS (COOL SEASON MIX) SHALL BE RESTRICTED TO THE PERIOD
FROM SEPTEMBER 1ST TO NOVEMBER 15TH. Z
Z: = ELEVATION
THE PLANTING OF TEMPORARY SEEDS (WARM SEASON MIX) SHALL BE RESTRICTED TO THE PERIOD
FROM MARCH 15TH TO JUNE 30TH. SYMBOLS
& = AND
AREAS ON WHICH SALVAGED TOPSOIL IS TO BE REPLACED SHALL HAVE 0-46-0 FERTILIZER APPLIED, AT = DIAMETER
THE RATE OF 150 LBS. PER ACRE, JUST PRIOR TO THE REPLACEMENT OF SALVAGED TOPSOIL. @ = AT
= DELTA
GENERAL NOTES
= CENTER LINE
PROJECT NUMBER
11058
STATE COUNTY
OKLAHOMA CARTER
SHEET NUMBER DATE
C002 APR 2026
| 8 1 8
8 2 0
822
824
826
826 FENCE AND ASSUMED
2
RIGHTS OF WAY
822
826
822
824
WATER LINE
1 STA. 1+11.31 INSTALL
+
45 DEG. BEND LAKE
0 824
0 MURRAY
0 DR
0 S 824 STA. 5+81 TO 6+37
STA. 1+11 TO 5+81
+ SILT FENCE, TYP. INSTALL 56 L.F. OF 8" PVC WATER LINE
WMWM 2 INSTALL 470 L.F. OF 8" PVC WATER LINE
TRANSITION FROM 5' OUTSIDE THE FENCE
BEGIN ALIGNMENT 8 2 6 5' OUTSIDE THE FENCE
TO 3' EAST OF THE EDGE OF ROAD
WATER LINE 0
0 WATER LINE
+
STA. 0+90.00 3 STA. 1+31.85 WATER LINE
N:299867.2568 0 6 INSTALL 8" TEE & FIRE 2 STA. 5+00.00
0 T 2 8 HYDRANT ASSEMBLY INSTALL 8" TEE & FIRE
+
E:2234358.4835 HYDRANT ASSEMBLY
4
0
828 828 8 2 8 828 SALVAGE AND EXISTING 5 WATER LINE
T 0 FIRE HYDRANT AND VALVES. 2 +
0 STA. 1+00.00 CONNECT TO
RETURN TO CITY. 6
+ 826 EXISTING WATER LINE
6
.
T INSTALL 45 DEG. BEND, TAPPING WATER LINE A
5+00 EM SLEEVE WITH VALVE. STA. 1+21.31 T
EM
GM 8 2 8 RECONNECT EXISTING 2 WATER LINE S
WATER METER SERVICE 1 STA. 5+81.29 INSTALL
E
TO NEW LINE 22 DEG. BEND
828 N
I
L
STA. 1+00 TO 1+11 WATER LINE
H
INSTALL 11 L.F. OF 8" WATER LINE STA. 6+36.73 INSTALL
C
TRANSITION FROM EXISTING LINE 22 DEG. BEND
T
TO 5' OUTSIDE THE FENCE 8 2
8 A
STA. 6+37 TO 6+50
8 M
2
8 INSTALL 13 L.F. OF 8" PVC WATER LINE
3' EAST OF THE EDGE OF ROAD
828 |
0' 30' 60' 120'
SCALE IN FEET |
Barker & Associates, Inc.
3902 University Blvd.
Durant, OK 74701
580.931.9045
OK. CA. 3998
EXP. 06/30/2026 |
|
|
|
CHECKED BY: H. WAYNE BARKER, P.E. |
|
|
|
PROFESSIONAL SEAL: |
|
|
NOTES:
1. CONTRACTOR TO FIELD VERIFY EXACT LOCATION OF
EXISTING WATER LINE BOTH HORIZONTALLY AND
VERTICALLY PRIOR TO ORDERING MATERIAL.
2. ALL DISTURBED AREA TO RECEIVE SOLID SLAB SOD
UNLESS OTHERWISE DIRECTED BY OWNER. |
|
|
|
|
DOWNTOWN
EXECUTIVE
AIRPARK
WL EXTENSION
CITY OF ARDMORE
ARDMORE, OKLAHOMA |
|
| 840 840
WATER LINE
WATER LINE STA. 5+00.00 INSTALL
STA. 5+00.00 INSTALL FIRE HYDRANT ASSEMBLY
FIRE HYDRANT ASSEMBLY
830 EXITING GRADE 830
1 2
1
820 PROPOSED 8" PVC 820
(36" COVER MIN.)
WATER LINE
STA. 1+00.00
CONNECT TO
EXISTING WATER
LINE INSTALL 45
DEG. BEND
810 810
800 800
0+50 1+00 2+00 3+00 4+00 5+00 6+00 6+50
WATER LINE
STA. (STA 0+50 TO STA. 6+50) |
|
|
|
|
|
DESIGNED BY:
JBA/HWB |
|
|
|
DRAWN BY:
JBA/JCD |
|
|
|
RECORD OF REVISIONS |
|
|
|
No. DATE DESCRIPTION |
|
|
|
1 5/12/2026 ADD |
RESSES DEQ COMMENTS |
|
|
2 7/16/2026 FINA |
L FOR BIDDING |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
WATERLINE A PLAN
AND PROFILE |
|
|
|
PROJECT NUMBER |
|
|
|
11058 |
|
|
|
STATE |
COUNTY |
|
|
OKLAHOMA |
CARTER |
|
|
SHEET NUMBER |
DATE |
|
|
CU200 |
APR 2026 |
| WATER LINE
STA. 5+00.00 INSTALL
FIRE HYDRANT ASSEMBLY
EXITING GRADE
1
PROPOSED 8" PVC
(36" COVER MIN.)
WATER LINE
STA. 1+00.00
CONNECT TO
EXISTING WATER
LINE INSTALL 45
DEG. BEND |
|
|
|
824
826
826
824
1
+
0
0
0
0
+
WMWM 2
BEGIN ALIGNMENT
WATER LINE 0
0
+
STA. 0+90.00 3
N:299867.2568 0
0 T
+
E:2234358.4835
4
T 0
0
+
6
T
5+00 EM
EM
GM
840 840
830 830
820 820
810 810
800 800
0+50 1+00 2+00 3+00 4+00 5+00 6+00 6+50
WATER LINE
STA. (STA 0+50 TO STA. 6+50)
8 2 0
822
824
6
2 8
828
8 1 8
826
822
828 8 2 8
828
8 2 8
828
826
8 2 6
Barker & Associates, Inc.
3902 University Blvd.
Durant, OK 74701
FENCE AND ASSUMED 580.931.9045
2
RIGHTS OF WAY OK. CA. 3998
822
EXP. 06/30/2026
0' 30' 60' 120'
CHECKED BY: H. WAYNE BARKER, P.E.
PROFESSIONAL SEAL:
WATER LINE SCALE IN FEET
STA. 1+11.31 INSTALL
45 DEG. BEND LAKE
MURRAY
DR
S 824 STA. 5+81 TO 6+37 NOTES:
STA. 1+11 TO 5+81
SILT FENCE, TYP. INSTALL 56 L.F. OF 8" PVC WATER LINE
INSTALL 470 L.F. OF 8" PVC WATER LINE 1. CONTRACTOR TO FIELD VERIFY EXACT LOCATION OF
TRANSITION FROM 5' OUTSIDE THE FENCE
5' OUTSIDE THE FENCE EXISTING WATER LINE BOTH HORIZONTALLY AND
TO 3' EAST OF THE EDGE OF ROAD
VERTICALLY PRIOR TO ORDERING MATERIAL.
WATER LINE 2. ALL DISTURBED AREA TO RECEIVE SOLID SLAB SOD
STA. 1+31.85 WATER LINE UNLESS OTHERWISE DIRECTED BY OWNER.
INSTALL 8" TEE & FIRE 2 STA. 5+00.00
HYDRANT ASSEMBLY INSTALL 8" TEE & FIRE
HYDRANT ASSEMBLY
0
SALVAGE AND EXISTING 5 WATER LINE
FIRE HYDRANT AND VALVES. 2 +
STA. 1+00.00 CONNECT TO
RETURN TO CITY. 6
EXISTING WATER LINE
.
INSTALL 45 DEG. BEND, TAPPING WATER LINE A DOWNTOWN
SLEEVE WITH VALVE. STA. 1+21.31 T
RECONNECT EXISTING 2 WATER LINE S WATER METER SERVICE 1 STA. 5+81.29 INSTALL EXECUTIVE
E
TO NEW LINE 22 DEG. BEND
N
AIRPARK
I
L
STA. 1+00 TO 1+11 WATER LINE
H
INSTALL 11 L.F. OF 8" WATER LINE STA. 6+36.73 INSTALL WL EXTENSION
C
TRANSITION FROM EXISTING LINE 22 DEG. BEND
T
TO 5' OUTSIDE THE FENCE 8 2
8 A
STA. 6+37 TO 6+50
8 M
2
8 INSTALL 13 L.F. OF 8" PVC WATER LINE
CITY OF ARDMORE
3' EAST OF THE EDGE OF ROAD
828
ARDMORE, OKLAHOMA
WATER LINE
WATER LINE STA. 5+00.00 INSTALL
STA. 5+00.00 INSTALL FIRE HYDRANT ASSEMBLY
FIRE HYDRANT ASSEMBLY
EXITING GRADE
1 2
1 DESIGNED BY: JBA/HWB
DRAWN BY:
JBA/JCD
RECORD OF REVISIONS
No. DATE DESCRIPTION
PROPOSED 8" PVC
1 5/12/2026 ADDRESSES DEQ COMMENTS
(36" COVER MIN.)
WATER LINE 2 7/16/2026 FINAL FOR BIDDING
STA. 1+00.00
CONNECT TO
EXISTING WATER
LINE INSTALL 45
DEG. BEND
WATERLINE A PLAN
AND PROFILE
PROJECT NUMBER
11058
STATE COUNTY
OKLAHOMA CARTER
SHEET NUMBER DATE
CU200 APR 2026
| 824 STA. 11+90 TO 13+40
INSTALL 150 L.F. OF 8" PVC WATER LINE
3' EAST OF THE EDGE OF ROAD
2 2 04+31
8
826 WATER LINE .ATS 2
8 2 6 STA. 11+95.23 INSTALL
8" TEE
8 2 4 826
824 ENILHCTAM 1
T
WATER LINE
0
STA. 11+90.23 824
0
+ END 8" HDPE (SLICK BORE)
13+00 2 0' 30' 60' 120' DR S
BEGIN 8" PVC MURRAY
1 826 WATER LINE LAKE FILTER SOCK, TYP.
WATER LINE
8 2 4
STA. 10+73.63
STA. 13+00.00
END 8" PVC, INSTALL 8" INSTALL 8" TEE & FIRE SCALE IN FEET
GATE VALVE W/BOX,
HYDRANT ASSEMBLY
BEGIN 8" HDPE (SLICK BORE)
0 8 2 8 8 2 6 2
0 0 SILT FENCE, TYP. NOTES:
+ T 5
0 11+00 8 2 + INSTALL 40 L.F. OF 8" HDPE (SLICK BORE) 1. ALL DISTURBED AREA TO RECEIVE SOLID SLAB SOD
1 8
6 UNLESS OTHERWISE DIRECTED BY OWNER.
0
0 8 2 6 . A
0
+ 0 8 2 6 6 T
8 2
+ 8 WATER LINE S
7 T FENCE AND ASSUMED
WATER LINE STA. 11+88.66, 52.43 RT.
4 2 STA. 9+00.00 INSTALL 11 DEG. BEND E 1 RIGHTS OF WAY
9+00 8 N STA. 10+74 TO 11+90
INSTALL 8" TEE & FIRE
I INSTALL 116 L.F. OF 8" HDPE (SLICKBORE)
HYDRANT ASSEMBLY L EXECUTIVE ARPT DR.
H
C
T STA. 6+50 TO 10+74
828 A INSTALL 424 L.F. OF 8" PVC WATER LINE
824 M 3' EAST OF THE EDGE OF ROAD
INSTALL 137 L.F. OF 8" PVC WATER LINE
3' NORTH OF CONCRETE FLUME OR
826
5' NORTH OF EDGE OF THE ROAD
WATER LINE
STA. 11+62.98, 126.93 RT.
INSTALL 11 DEG. BEND
WATER LINE
STA. 11+41.71, 169.17 RT.
END 8" PVC
INSTALL FIRE HYDRANT
ASSEMBLY
840 840
WATER LINE
WATER LINE STA. 13+00.00 INSTALL
STA. 9+00.00 INSTALL FIRE HYDRANT ASSEMBLY
830 830 FIRE HYDRANT ASSEMBLY EXITING GRADE
1
1 2
4
.0
4.00' 0
'
820 820 PROPOSED 8" PVC
(36" COVER MIN.)
PROPOSED 8" PVC
STA. 10+73.63 STA. 10+74 TO 11+90 (36" COVER MIN.)
INSTALL 8" GATE INSTALL 116 L.F. OF 8" HDPE
VALVE W/BOX (SLICK BORE)
810 810
800 800
6+50 7+00 8+00 9+00 10+00 11+00 12+00 13+00 13+40
WATER LINE
STA. (STA 6+50 TO STA. 13+40) |
Barker & Associates, Inc.
3902 University Blvd.
Durant, OK 74701
580.931.9045
OK. CA. 3998
EXP. 06/30/2026 |
|
|
CHECKED BY: H. WAYNE BARKER, P.E. |
|
|
PROFESSIONAL SEAL: |
|
|
DOWNTOWN
EXECUTIVE
AIRPARK
WL EXTENSION
CITY OF ARDMORE
ARDMORE, OKLAHOMA |
|
|
|
|
|
DESIGNED BY:
JBA/HWB |
|
|
DRAWN BY:
JBA/JCD |
|
|
RECORD OF REVISIONS |
|
|
No. DATE DESCRIPTION |
|
|
1 5/12/2026 ADD |
RESSES DEQ COMMENTS |
|
2 7/16/2026 FINA |
L FOR BIDDING |
|
|
|
|
|
|
|
|
|
|
WATERLINE A PLAN
AND PROFILE |
|
|
PROJECT NUMBER |
|
|
11058 |
|
|
STATE |
COUNTY |
|
OKLAHOMA |
CARTER |
|
SHEET NUMBER |
DATE |
|
CU201 |
APR 2026 |
| WATER LINE
WATER LINE STA. 13+00.00 INSTALL
STA. 9+00.00 INSTALL FIRE HYDRANT ASSEMBLY
FIRE HYDRANT ASSEMBLY EXITING GRADE
1
1 2
4
.0
4.00' 0
'
PROPOSED 8" PVC
(36" COVER MIN.)
PROPOSED 8" PVC
STA. 10+73.63 STA. 10+74 TO 11+90 (36" COVER MIN.)
INSTALL 8" GATE INSTALL 116 L.F. OF 8" HDPE
VALVE W/BOX (SLICK BORE) |
|
|
|
|
|
2 2
8
824
T
0
0
+
13+00 2
1
0
0
+ T
0 11+00
1
0
0
0
+ 0
8
+
7 T
9+00
8 2 8
8 2
8
8 2 6
8 2 6
828
8 2 6
826
826
6
2
8
4 2
8
824
826
8 2 6
8 2 4
824
826
8 2 4
WATER LINE
STA. 11+95.23 INSTALL
8" TEE
WATER LINE
STA. 11+90.23 824
END 8" HDPE (SLICK BORE)
BEGIN 8" PVC
WATER LINE WATER LINE
STA. 10+73.63
STA. 13+00.00
END 8" PVC, INSTALL 8" INSTALL 8" TEE & FIRE
GATE VALVE W/BOX,
HYDRANT ASSEMBLY
BEGIN 8" HDPE (SLICK BORE)
WATER LINE
WATER LINE STA. 11+88.66, 52.43 RT.
STA. 9+00.00 INSTALL 11 DEG. BEND
INSTALL 8" TEE & FIRE
HYDRANT ASSEMBLY
WATER LINE
STA. 11+62.98, 126.93 RT.
INSTALL 11 DEG. BEND
WATER LINE
STA. 11+41.71, 169.17 RT.
END 8" PVC
INSTALL FIRE HYDRANT
ASSEMBLY
840 840
830 830
820 820
810 810
800 800
6+50 7+00 8+00 9+00 10+00 11+00 12+00 13+00 13+40
WATER LINE
STA. (STA 6+50 TO STA. 13+40)
4.00'
STA. 11+90 TO 13+40
INSTALL 150 L.F. OF 8" PVC WATER LINE
3' EAST OF THE EDGE OF ROAD
Barker & Associates, Inc.
3902 University Blvd.
Durant, OK 74701
580.931.9045
OK. CA. 3998
EXP. 06/30/2026
0' 30' 60' 120'
LAKE
MURRAY
DR S
FILTER SOCK, TYP. CHECKED BY: H. WAYNE BARKER, P.E.
PROFESSIONAL SEAL: SCALE IN FEET
0 SILT FENCE, TYP.
5
+ INSTALL 40 L.F. OF 8" HDPE (SLICK BORE)
6
. A
T
S
E
N STA. 10+74 TO 11+90
I INSTALL 116 L.F. OF 8" HDPE (SLICKBORE)
H
L EXECUTIVE ARPT DR.
C
T STA. 6+50 TO 10+74
A INSTALL 424 L.F. OF 8" PVC WATER LINE DOWNTOWN
M 3' EAST OF THE EDGE OF ROAD
INSTALL 137 L.F. OF 8" PVC WATER LINE
EXECUTIVE
3' NORTH OF CONCRETE FLUME OR
5' NORTH OF EDGE OF THE ROAD
AIRPARK
WL EXTENSION
CITY OF ARDMORE
ARDMORE, OKLAHOMA
WATER LINE
WATER LINE STA. 13+00.00 INSTALL
STA. 9+00.00 INSTALL FIRE HYDRANT ASSEMBLY
FIRE HYDRANT ASSEMBLY EXITING GRADE
DESIGNED BY:
JBA/HWB
DRAWN BY:
JBA/JCD
4
.0
0
' RECORD OF REVISIONS
No. DATE DESCRIPTION
PROPOSED 8" PVC
(36" COVER MIN.)
PROPOSED 8" PVC
STA. 10+73.63 STA. 10+74 TO 11+90 (36" COVER MIN.)
INSTALL 8" GATE INSTALL 116 L.F. OF 8" HDPE
VALVE W/BOX (SLICK BORE)
WATERLINE A PLAN
AND PROFILE
PROJECT NUMBER
11058
STATE COUNTY
OKLAHOMA CARTER
SHEET NUMBER DATE
CU201 APR 2026
04+31
.ATS
ENILHCTAM
2
1
2
NOTES:
1. ALL DISTURBED AREA TO RECEIVE SOLID SLAB SOD
UNLESS OTHERWISE DIRECTED BY OWNER.
FENCE AND ASSUMED
1 RIGHTS OF WAY
1
1 2
1 5/12/2026 ADDRESSES DEQ COMMENTS
2 7/16/2026 FINAL FOR BIDDING
| 820
822
S
R
D
Y
A
R
R
0' 30' 60' 120' U
M
E
822 K
A
L
SCALE IN FEET 04+31
820 .ATS NOTES:
1. ALL DISTURBED AREA TO RECEIVE SOLID SLAB SOD
UNLESS OTHERWISE DIRECTED BY OWNER.
8 2 0 824 ENILHCTAM
SILT FENCE, TYP.
8 2 2
824
END ALIGNMENT
822
0
WATER LINE
0
+
5 STA. 15+40.23
1
N:298503.3258
2
E:2234752.3864
0
0
+
WATER LINE
4 R.
D
1 STA. 15+40.23 T
RP
END 8" PVC A VE
TI
INSTALL 8" TEE, 8" BLIND FLANGE U
C
XE
& FIRE HYDRANT ASSEMBLY E
STA. 13+40.00 TO 15+40.23
INSTALL 200 L.F. OF 8" PVC WATER LINE
3' EAST OF THE EDGE OF ROAD
840 840
830 830 WATER LINE
STA. 15+40.23 END 8" PVC
INSTALL 8" TEE, 8" BLIND
FLANGE & FIRE HYDRANT
EXITING GRADE ASSEMBLY
820 820
PROPOSED 8" PVC
(36" COVER MIN.)
810 810
800 800
13+40 14+00 15+00 15+50
WATER LINE
STA. (STA 13+40 TO STA. 15+50) |
Barker & Associates, Inc.
3902 University Blvd.
Durant, OK 74701
580.931.9045
OK. CA. 3998
EXP. 06/30/2026 |
|
|
CHECKED BY: H. WAYNE BARKER, P.E. |
|
|
PROFESSIONAL SEAL: |
|
|
|
|
|
DOWNTOWN
EXECUTIVE
AIRPARK
WL EXTENSION
CITY OF ARDMORE
ARDMORE, OKLAHOMA |
|
|
|
|
|
DESIGNED BY:
JBA/HWB |
|
|
DRAWN BY:
JBA/JCD |
|
|
RECORD OF REVISIONS |
|
|
No. DATE DESCRIPTION |
|
|
2 7/16/2026 FINA |
L FOR BIDDING |
|
|
|
|
|
|
|
|
|
|
|
|
|
WATER LINE A
PLAN & PROFILE |
|
|
PROJECT NUMBER |
|
|
11058 |
|
|
STATE |
COUNTY |
|
OKLAHOMA |
CARTER |
|
SHEET NUMBER |
DATE |
|
CU202 |
APR 2026 |
| WATER LINE
STA. 15+40.23 END 8" PVC
INSTALL 8" TEE, 8" BLIND
FLANGE & FIRE HYDRANT
EXITING GRADE ASSEMBLY
PROPOSED 8" PVC
(36" COVER MIN.) |
|
|
|
|
|
820
820
0
0
+
5
1
0
0
+
4
1
8 2 0
822
822
8 2 2
Barker & Associates, Inc.
3902 University Blvd.
Durant, OK 74701
580.931.9045
OK. CA. 3998
EXP. 06/30/2026 0' 30' 60' 120'
CHECKED BY: H. WAYNE BARKER, P.E.
PROFESSIONAL SEAL: SCALE IN FEET
824
824
END ALIGNMENT
822
WATER LINE
STA. 15+40.23
N:298503.3258 DOWNTOWN
E:2234752.3864
EXECUTIVE
WATER LINE
AIRPARK
STA. 15+40.23
END 8" PVC
INSTALL 8" TEE, 8" BLIND FLANGE WL EXTENSION
& FIRE HYDRANT ASSEMBLY
CITY OF ARDMORE
ARDMORE, OKLAHOMA
840 840
830 830
DESIGNED BY:
JBA/HWB
DRAWN BY:
JBA/JCD
RECORD OF REVISIONS
No. DATE DESCRIPTION
820 820
810 810
800 800
PROJECT NUMBER
11058
13+40 14+00 15+00 15+50 STATE COUNTY
WATER LINE
OKLAHOMA CARTER
STA. (STA 13+40 TO STA. 15+50)
SHEET NUMBER DATE
APR 2026
04+31
.ATS
ENILHCTAM
S
R
D
Y
A R
R
U
M
E
K
A
L
NOTES:
1. ALL DISTURBED AREA TO RECEIVE SOLID SLAB SOD
UNLESS OTHERWISE DIRECTED BY OWNER.
SILT FENCE, TYP.
2
R.
D
T
RP
A VE
TI
U
C
XE
E
STA. 13+40.00 TO 15+40.23
INSTALL 200 L.F. OF 8" PVC WATER LINE
3' EAST OF THE EDGE OF ROAD
WATER LINE
STA. 15+40.23 END 8" PVC
INSTALL 8" TEE, 8" BLIND
FLANGE & FIRE HYDRANT
EXITING GRADE ASSEMBLY
2 7/16/2026 FINAL FOR BIDDING
PROPOSED 8" PVC
(36" COVER MIN.)
WATER LINE A
PLAN & PROFILE
CU202
| PIPE STANDARD STANDARD
STANDARD TRENCH WIDTH
INSIDE TRENCH COVER
DIAMETER WIDTH DEPTH
IN. IN. IN.
FINAL BACKFILL
6 24 REVOC HTPED
SELECT FILL "21
8 24 36
INITIAL BACKFILL 10 30 "21
6" MIN
12 36
12" MAX.
15/16 36 42 UNDISTURBED
18 36 EARTH
21 42 HAUNCHING SPRING LINE
BEDDING MIN. 4"
24 42 OF PIPE
27 48 AS
NOTED
30 48
36 54
42 60
48 66
BEDDING MATERIALS
NON-PAVED AREAS PAVED AREAS
BACKFILL
DESCRIPTION DUCTILE DUCTILE
PVC HDPE PVC HDPE
IRON IRON
FINAL EXCAVATED EXCAVATED EXCAVATED
SBM SBM SBM
BACKFILL MATERIAL MATERIAL MATERIAL
SELECT SELECT SELECT SELECT SBM SBM
SBM
BACKFILL FILL FILL FILL
COVER COVER
INITIAL 10'-SAND SELECT 10'-SAND SBM SBM
BACKFILL OR SBM FILL OR SBM SBM
10'-SBM
10'-SBM
COVER COVER
HAUNCHING 10'-SAND SELECT 10'-SAND SBM SBM SBM
OR SBM FILL OR SBM
10'-SBM
10'-SBM
BEDDING See Note 5 See Note 5 See Note 5 See Note 5 See Note 5 See Note 5
NOTES:
1. INSTALLATION AND BACK FILLING SHALL MEET MANUFACTURING RECOMMENDATIONS.
2. SELECT FILL CONSISTS OF EXCAVATED MATERIALS CONTAINING NO ROCKS LARGER THAN 50 MM (2").
3. STANDARD BEDDING MATERIAL (SBM) SHALL CONFORM TO ODOT 703.01, TYPE A AGGREGATE BASE OR FLOWABLE
FILL PER SECTION 501.02(B).
4. COMPACTIONS REQUIREMENTS:
a. NON PAVED AREAS: 90% MAXIMUM STANDARD PROCTOR DENSITY FOR COHESION LESS SOIL AND 85% FOR
COHESIVE SOILS.
b. PAVED AREAS: 95% MAXIMUM STANDARD PROCTOR DENSITY FOR COHESION LESS SOILS.
5. IF TRENCH IS DRY BEDDING SHALL BE 4" SAND OR TYPE A AGGREGATE BASE, AND IF WET SHALL BE NO. 57
OR
SECTION 701.06(C).
6. IN SANDY SOIL, CONTRACTOR MAY BACKFILL WITH NATIVE MATERIAL AND USE WARNING TAPE 18" ABOVE PIPE.
7. NO WATER JETTING ALLOWED.
UTILITY TRENCHING AND BEDDING
6
SCALE: NOT TO SCALE |
|
2" - 8" PIPE LARGER
VALVES, TEES
PIPE 11 1 4 degrees 22 1 2 degrees 45 degrees 90 degrees & DEAD ENDS
2" 0.2 0.2 0.5 0.8 0.6
4" 0.5 0.8 1.7 2.7 2.8
6" 0.9 1.5 3.0 6.0 4.0
8" 1.4 2.9 6.0 10.0 8.5
10" 2.0 4.5 9.0 16.2 12.0
12" 3.0 6.8 12.0 21.0 16.0
18" 6.2 14.0 23.0 50.0 30.0
20" 11 21 42.2 78 55
MINIMUM SQ.FT. BEARING AREA REQUIRED AT 150 PSI.
1. AREA IS BASED ON 1000 PSF ALLOWABLE BEARING PRESSURE.
2. WHEN SOFT CLAY IS ENCOUNTERED THE BEARING AREAS SHALL BE
DOUBLED.
3. USE CONCRETE FORMS TO KEEP CONCRETE CLEAR OF ALL BOLTS AND
FLANGES.
4. TABLE IS BASED ON AWWA NO. 23, PVC PIPE DESIGN MANUAL.
5. ALL FITTINGS (INCLUDING NUTS AND BOLTS) TO BE WRAPPED WITH 6 MIL
POLY WRAP.
THRUST BLOCK
5
SCALE: NOT TO SCALE |
NOTES:
1. ALL CONSTRUCTION SHALL CONFORM TO OKLAHOMA DEPT.
OF ENVIRONMENTAL QUALITY (ODEQ).
2. SEPARATION OF WATER MAINS AND SEWERS FROM
CONTAMINATION SOURCES SHALL CONFORM TO ODEQ
REGULATION 252:626-19-2(h). ODEQ REGULATION
252:626-19-2(h) STATES THE FOLLOWING:
(h) Separation of water mains and sewers from contamination
sources.
(1) Horizontal separation.
(A)Measure the separation distance edge to edge.
(B) Locate water mains at least 10 feet horizontally from any
existing or proposed sewer lines.
(C) Locate water mains at least 5 feet horizontally from any
existing or proposed storm sewers, raw water lines, petroleum
product lines, natural gas lines, and other buried utility lines.
(D)Locate cast iron waterlines at least 10 feet from any
gasoline storage tank and lines and PVC water lines at least
50 feet horizontally from any gasoline storage tank and lines.
(E) Locate waterlines at least 15 feet from all parts of septic
tanks and absorption fields, or other sewage treatment and
disposal systems.
(2) Vertical Separation.
(A)Measure the separation distance from edge to edge.
(B) Lay waterlines crossing sewer lines to provide a minimum
vertical distance of 24 inches between the water main and the
sewer line. Arrange the piping so that joints in a 20-foot length
of PVC or 18-foot length of cast iron sewer pipe will be
equidistant from the water main. Where a water main crosses
under a sewer, provide adequate structural support for the
sewer to prevent damage to the water main.
(C) Maintain a 2-foot vertical separation between waterlines
and any existing or proposed storm sewers, raw water lines,
petroleum product lines, natural gas lines, and other buried
utility lines.
(3) Special conditions. When it is impossible to obtain proper
horizontal and vertical separation as stipulated in (1) and (2) of this
subsection, design and construct the other line equal to water pipe,
and pressure test it to assure water tightness of joints adjacent to the
water line prior to backfilling.
10'-0" 10'-0"
PRESSURE PIPE* PRESSURE PIPE*
WATER LINE
"0-'2 PRESSURE PIPE*
<
L/2 L/2 SANITARY
SEWER
10'-0" 10'-0"
PRESSURE PIPE* PRESSURE PIPE*
L/2 L/2
5'-0" 5'-0"
SANITARY
SEWER
STRUCTURAL SUPPORT
TO PROTECT WATER WATER
LINE LINE
VERTICAL
* PRESSURE PIPE SHALL BE
EQUAL TO WATER PIPE
AND PRESSURE TESTED.
< 10'-0"
USE PRESSURE
PIPE* FOR SEWER
SANITARY
WATER
SEWER
LINE
HORIZONTAL
WATER AND SEWER SEPARATION DETAIL
1
SCALE: NOT TO SCALE |
Barker & Associates, Inc.
3902 University Blvd.
Durant, OK 74701
580.931.9045
OK. CA. 3998
EXP. 06/30/2026 |
|
|
|
|
|
CHECKED BY: H. WAYNE BARKER, P.E. |
|
|
|
|
|
PROFESSIONAL SEAL: |
|
|
|
|
|
|
|
|
|
|
|
DOWNTOWN
EXECUTIVE
AIRPARK
WL EXTENSION
CITY OF ARDMORE
ARDMORE, OKLAHOMA |
|
|
|
|
|
DESIGNED BY: |
|
|
|
A
A
A
A
A
NOTE:
THE LENGTHS OF PIPE WITH
RESTRAINED JOINTS ARE BASED
ON A COMPACTED SILTY SOIL
SURROUNDING THE PIPE
A
TEE & 90 degrees 45 degrees 22 1 2 degrees 11 1 4 degrees
SIZE
PLUG BEND BEND BEND BEND
IN. FT. FT. FT. FT. FT.
6 12 17 10 6 3
8 16 22 13 8 4
10 19 27 16 9 5
12 23 32 19 11 6
14 26 36 21 12 7
16 29 41 24 14 8
18 32 45 26 15 8
20 35 50 29 16 9
24 41 58 34 19 10
(LENGTH REQUIRED FOR RESTRAINING JOINTS)
RESTRAINED JOINT
2
SCALE: NOT TO SCALE |
|
|
|
| TRENCH
12" WIDTH
HDPE
6" TYP.
PVC
PLAN
CONC. ANCHOR
HDPE PVC
WALL ANCHOR
ELEVATION
12"
CONCRETE ANCHOR HDPE
PIPE RESTRAINT DETAIL
N.T.S.
CONCRETE ANCHOR HDPE
PIPE RESTRAINT DETAIL
4
SCALE: NOT TO SCALE |
CAST IRON # 70
VALVE BOX AND LID
.
EXISTING GROUND
GENERAL NOTES:
ALL FITTINGS (INCLUDING NUTS
AND BOLTS) TO BE WRAPPED
6" PVC PIPE
WITH 6 MIL POLYTHYLENE WRAP
TRACER WIRE OR EQUAL.
COIL A MIN. OF 12" OF TRACER
WIRE AT VALVE BOX LID.
GATE VALVE
(MJxFL) OR EQUIV.
NEW MAIN
THRUST BLOCKING
FORD-FAST
TAPPING SLEEVE W/
CARBON STEEL FLANGE
TYPICAL TAPPING SLEEVE AND VALVE
N.T.S.
TYPICAL TAPPING SLEEVE AND VALVE
3
SCALE: NOT TO SCALE |
|
|
|
|
|
|
|
|
JBA/HWB |
|
|
|
|
|
DRAWN BY:
JBA/JCD |
|
|
|
|
|
RECORD OF REVISIONS |
|
|
|
|
|
No. DATE DESCRIPTION |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
WATER LINE
DETAILS |
|
|
|
|
|
PROJECT NUMBER |
|
|
|
|
|
11058 |
|
|
|
|
|
STATE |
COUNTY |
|
|
|
|
OKLAHOMA |
CARTER |
|
|
|
|
SHEET NUMBER |
DATE |
|
|
|
|
CU500 |
APR 2026 |
| PIPE
INSIDE
DIAMETER
IN. |
STANDARD
TRENCH
WIDTH
IN. |
STANDARD
COVER
DEPTH
IN. |
| 6 |
24 |
36 |
| 8 |
24 |
|
| 10 |
30 |
|
| 12 |
36 |
42 |
| 15/16 |
36 |
|
| 18 |
36 |
|
| 21 |
42 |
AS
NOTED |
| 24 |
42 |
|
| 27
30 |
48
48 |
|
| 36 |
54 |
|
| 42 |
60 |
|
| 48 |
66 |
|
| BEDDING MATERIALS |
|
|
|
|
|
|
| BACKFILL
DESCRIPTION |
NON-PAVED AREAS |
|
|
PAVED AREAS |
|
|
|
PVC |
DUCTILE
IRON |
HDPE |
PVC |
DUCTILE
IRON |
HDPE |
| FINAL
BACKFILL |
EXCAVATED
MATERIAL |
EXCAVATED
MATERIAL |
EXCAVATE
MATERIAL |
D
SBM |
SBM |
SBM |
| SELECT
BACKFILL |
SELECT
FILL |
SELECT
FILL |
SELECT
FILL |
SBM |
SBM |
SBM |
| INITIAL
BACKFILL |
COVER
10'-SAND
OR SBM
10'-SBM |
SELECT
FILL |
COVER
10'-SAND
OR SBM
10'-SBM |
SBM |
SBM |
SBM |
| HAUNCHING |
COVER
10'-SAND
OR SBM
10'-SBM |
SELECT
FILL |
COVER
10'-SAND
OR SBM
10'-SBM |
SBM |
SBM |
SBM |
| BEDDING |
See Note 5 |
See Note 5 |
See Note 5 |
See Note 5 |
See Note 5 |
See Note 5 |
| degrees 22 1 2 degrees 45 degrees 90 degrees |
VALVES, TEES
& DEAD ENDS |
| 0.2 0.5 0.8 |
0.6 |
| 0.8 1.7 2.7 |
2.8 |
| 1.5 3.0 6.0 |
4.0 |
| 2.9 6.0 10.0 |
8.5 |
| 4.5 9.0 16.2 |
12.0 |
| 6.8 12.0 21.0 |
16.0 |
| 14.0 23.0 50.0 |
30.0 |
| 21 42.2 78 |
55 |
|
A |
|
| TEE &
SIZE
PLUG
IN. FT. |
90 degrees 45 degrees 2
BEND BEND
FT. FT. |
1 1
2 2 degrees 11 4 degrees
BEND BEND
FT. FT. |
| 6 12 |
17 10 |
6 3 |
| 8 16 |
22 13 |
8 4 |
| 10 19 |
27 16 |
9 5 |
| 12 23 |
32 19 |
11 6 |
| 14 26
16 29 |
36 21
41 24 |
12 7
14 8 |
| 18 32 |
45 26 |
15 8 |
| 20 35 |
50 29 |
16 9 |
| 24 41 |
58 34 |
19 10 |
PIPE STANDARD STANDARD
STANDARD TRENCH WIDTH
INSIDE TRENCH COVER
DIAMETER WIDTH DEPTH
IN. IN. IN.
FINAL BACKFILL
6 24
SELECT FILL 8 24 36
INITIAL BACKFILL 10 30
6" MIN
12 36
12" MAX.
15/16 36 42 UNDISTURBED
18 36 EARTH
21 42 HAUNCHING SPRING LINE
BEDDING MIN. 4" 24 42 OF PIPE
27 48 AS
NOTED
30 48
36 54
42 60
48 66
BEDDING MATERIALS
NON-PAVED AREAS PAVED AREAS
BACKFILL
DESCRIPTION DUCTILE DUCTILE
PVC HDPE PVC HDPE
IRON IRON
FINAL EXCAVATED EXCAVATED EXCAVATED
SBM SBM SBM
BACKFILL MATERIAL MATERIAL MATERIAL
SELECT SELECT SELECT SELECT SBM SBM
SBM BACKFILL FILL FILL FILL
COVER COVER
INITIAL 10'-SAND SELECT 10'-SAND SBM SBM
BACKFILL OR SBM FILL OR SBM SBM
10'-SBM
10'-SBM
COVER COVER
HAUNCHING 10'-SAND SELECT 10'-SAND SBM SBM SBM
OR SBM FILL OR SBM
10'-SBM
10'-SBM
BEDDING See Note 5 See Note 5 See Note 5 See Note 5 See Note 5 See Note 5
NOTES:
1. INSTALLATION AND BACK FILLING SHALL MEET MANUFACTURING RECOMMENDATIONS.
2. SELECT FILL CONSISTS OF EXCAVATED MATERIALS CONTAINING NO ROCKS LARGER THAN 50 MM (2").
3. STANDARD BEDDING MATERIAL (SBM) SHALL CONFORM TO ODOT 703.01, TYPE A AGGREGATE BASE OR FLOWABLE
FILL PER SECTION 501.02(B).
4. COMPACTIONS REQUIREMENTS:
a. NON PAVED AREAS: 90% MAXIMUM STANDARD PROCTOR DENSITY FOR COHESION LESS SOIL AND 85% FOR
COHESIVE SOILS.
b. PAVED AREAS: 95% MAXIMUM STANDARD PROCTOR DENSITY FOR COHESION LESS SOILS.
5. IF TRENCH IS DRY BEDDING SHALL BE 4" SAND OR TYPE A AGGREGATE BASE, AND IF WET SHALL BE NO. 57
OR
SECTION 701.06(C).
6. IN SANDY SOIL, CONTRACTOR MAY BACKFILL WITH NATIVE MATERIAL AND USE WARNING TAPE 18" ABOVE PIPE.
7. NO WATER JETTING ALLOWED.
"21
"21
REVOC HTPED
2" - 8" PIPE LARGER
VALVES, TEES
PIPE 11 1 4 degrees 22 1 2 degrees 45 degrees 90 degrees & DEAD ENDS
2" 0.2 0.2 0.5 0.8 0.6
4" 0.5 0.8 1.7 2.7 2.8
6" 0.9 1.5 3.0 6.0 4.0
8" 1.4 2.9 6.0 10.0 8.5
10" 2.0 4.5 9.0 16.2 12.0
12" 3.0 6.8 12.0 21.0 16.0
18" 6.2 14.0 23.0 50.0 30.0
20" 11 21 42.2 78 55
MINIMUM SQ.FT. BEARING AREA REQUIRED AT 150 PSI.
1. AREA IS BASED ON 1000 PSF ALLOWABLE BEARING PRESSURE.
2. WHEN SOFT CLAY IS ENCOUNTERED THE BEARING AREAS SHALL BE
DOUBLED.
3. USE CONCRETE FORMS TO KEEP CONCRETE CLEAR OF ALL BOLTS AND
FLANGES.
4. TABLE IS BASED ON AWWA NO. 23, PVC PIPE DESIGN MANUAL.
5. ALL FITTINGS (INCLUDING NUTS AND BOLTS) TO BE WRAPPED WITH 6 MIL
POLY WRAP.
NOTE:
THE LENGTHS OF PIPE WITH
RESTRAINED JOINTS ARE BASED
ON A COMPACTED SILTY SOIL
SURROUNDING THE PIPE
A
TEE & 90 degrees 45 degrees 22 1 2 degrees 11 1 4 degrees
SIZE
PLUG BEND BEND BEND BEND
IN. FT. FT. FT. FT. FT.
6 12 17 10 6 3
8 16 22 13 8 4
10 19 27 16 9 5
12 23 32 19 11 6
14 26 36 21 12 7
16 29 41 24 14 8
18 32 45 26 15 8
20 35 50 29 16 9
24 41 58 34 19 10
(LENGTH REQUIRED FOR RESTRAINING JOINTS)
A
A
A
NOTES:
1. ALL CONSTRUCTION SHALL CONFORM TO OKLAHOMA DEPT.
OF ENVIRONMENTAL QUALITY (ODEQ).
2. SEPARATION OF WATER MAINS AND SEWERS FROM
CONTAMINATION SOURCES SHALL CONFORM TO ODEQ
REGULATION 252:626-19-2(h). ODEQ REGULATION
252:626-19-2(h) STATES THE FOLLOWING:
(h) Separation of water mains and sewers from contamination
sources.
(1) Horizontal separation.
(A)Measure the separation distance edge to edge.
(B) Locate water mains at least 10 feet horizontally from any
existing or proposed sewer lines.
(C) Locate water mains at least 5 feet horizontally from any
existing or proposed storm sewers, raw water lines, petroleum
product lines, natural gas lines, and other buried utility lines.
(D)Locate cast iron waterlines at least 10 feet from any
gasoline storage tank and lines and PVC water lines at least
50 feet horizontally from any gasoline storage tank and lines.
(E) Locate waterlines at least 15 feet from all parts of septic
tanks and absorption fields, or other sewage treatment and
disposal systems.
(2) Vertical Separation.
(A)Measure the separation distance from edge to edge.
(B) Lay waterlines crossing sewer lines to provide a minimum
vertical distance of 24 inches between the water main and the
sewer line. Arrange the piping so that joints in a 20-foot length
of PVC or 18-foot length of cast iron sewer pipe will be
equidistant from the water main. Where a water main crosses
under a sewer, provide adequate structural support for the
sewer to prevent damage to the water main.
(C) Maintain a 2-foot vertical separation between waterlines
and any existing or proposed storm sewers, raw water lines,
petroleum product lines, natural gas lines, and other buried
utility lines.
(3) Special conditions. When it is impossible to obtain proper
horizontal and vertical separation as stipulated in (1) and (2) of this
subsection, design and construct the other line equal to water pipe,
and pressure test it to assure water tightness of joints adjacent to the
water line prior to backfilling.
10'-0" 10'-0"
PRESSURE PIPE* PRESSURE PIPE*
L/2 L/2
A
A
VERTICAL
HORIZONTAL
"0-'2
<
Barker & Associates, Inc.
3902 University Blvd.
Durant, OK 74701
580.931.9045
OK. CA. 3998
EXP. 06/30/2026
CHECKED BY: H. WAYNE BARKER, P.E.
PROFESSIONAL SEAL:
DOWNTOWN
EXECUTIVE
AIRPARK
WL EXTENSION
CITY OF ARDMORE
WATER LINE
ARDMORE, OKLAHOMA
PRESSURE PIPE*
THRUST BLOCK SANITARY
5
SEWER SCALE: NOT TO SCALE
10'-0" 10'-0"
PRESSURE PIPE* PRESSURE PIPE*
UTILITY TRENCHING AND BEDDING
6
SCALE: NOT TO SCALE
L/2 L/2
5'-0" 5'-0"
DESIGNED BY:
JBA/HWB
CAST IRON # 70
VALVE BOX AND LID SANITARY DRAWN BY: JBA/JCD
SEWER
. STRUCTURAL SUPPORT
TO PROTECT WATER WATER RECORD OF REVISIONS
LINE LINE
TRENCH
EXISTING GROUND No. DATE DESCRIPTION
12" WIDTH
GENERAL NOTES:
HDPE
ALL FITTINGS (INCLUDING NUTS
AND BOLTS) TO BE WRAPPED * PRESSURE PIPE SHALL BE
6" PVC PIPE
WITH 6 MIL POLYTHYLENE WRAP EQUAL TO WATER PIPE
6" TYP. TRACER WIRE OR EQUAL. AND PRESSURE TESTED. < 10'-0"
PVC
PLAN USE PRESSURE
COIL A MIN. OF 12" OF TRACER
PIPE* FOR SEWER
CONC. ANCHOR WIRE AT VALVE BOX LID.
HDPE PVC
GATE VALVE
(MJxFL) OR EQUIV.
WALL ANCHOR
ELEVATION
12"
NEW MAIN SANITARY
WATER
SEWER
LINE
CONCRETE ANCHOR HDPE WATER LINE
PIPE RESTRAINT DETAIL DETAILS
THRUST BLOCKING
N.T.S.
FORD-FAST PROJECT NUMBER
TAPPING SLEEVE W/
11058
CARBON STEEL FLANGE
TYPICAL TAPPING SLEEVE AND VALVE STATE COUNTY
N.T.S. OKLAHOMA CARTER
CONCRETE ANCHOR HDPE
PIPE RESTRAINT DETAIL TYPICAL TAPPING SLEEVE AND VALVE RESTRAINED JOINT WATER AND SEWER SEPARATION DETAIL
4 3 2 1 SHEET NUMBER DATE
SCALE: NOT TO SCALE SCALE: NOT TO SCALE SCALE: NOT TO SCALE SCALE: NOT TO SCALE