Pharmaceuticals/Hygiene/Medical for WV Military Authority

Location: West Virginia
Posted: Apr 6, 2025
Due: Apr 24, 2025
Agency: State of West Virginia
Type of Government: State & Local
Category:
  • 65 - Medical, Dental, and Veterinary Equipment and Supplies
  • S - Utilities and Training Services
Solicitation No: ARFQ-0603-ADJ2500000014-1
Publication URL: To access bid details, please log in.

Description: Pharmaceuticals/Hygiene/Medical for WV Military Authority

Department: ADJUTANT GENERAL

Buyer: Cara M Suppa

Solicitation Number: ARFQ-0603-ADJ2500000014-1

Type: Agency Request for Quote (ARFQ)

Category: Medical

Closing Date and Time: 04/24/2025 01:30 PM EDT


Buyer Information
Buyer Name
John W Estep
Buyer Email
john.w.estep@wv.gov
Buyer Phone
304-558-2566
Buyer Fax
-
Important Dates
Issue Date
04/03/2025
Closing Date
04/24/2025 01:30 PM EDT
Bid Opening Date
-
Last Amended
-
Department Information
Category
Highways
Type
Centralized Request for Quote
Document Department
0803
Status
Open
Description
Concrete Plank Beams, Bridge rail, and Components
Group 1
Default Commodity Group
Number of Lines: 14
Line Number Commodity Description Details Requested
1
Plank beam must be 4 pieces - 4 feet 0 inches X 29 feet 6 inches. Plank beam must have a minimum strength of 6000 psi at detention and 8000 psi at 28 days. Pre-stressing strands must be seven-wire uncoated low relaxation over size strand (AS = 0.167 square inches), with a minimum tensile strength of 270,000 psi. Interior box beams shall have "Tex-Cote 300 Bridge Cote" Latex Acrylic Copolymer Coating or equivalent applied to the bottom of the beams. Plank beam lab reports must accompany the shipping ticket.
Specifications
Commodity Code
30101700
Quantity
472.00000
Unit of Measure
SF
Delivery Date
-
View Purchase History
Additional Information
2
Plank beam must be 2 pieces - 4 feet 0 inches X 29 feet 6 inches. Plank beam must have a minimum strength of 6000 psi at detention and 8000 psi at 28 days. Pre-stressing strands must be seven-wire uncoated low relaxation oversize strand (AS = 0.167 square inches), with a minimum tensile strength of 270,000 psi. Exterior box beams shall have "Tex-Cote 300 Bridge Cote" Latex Acrylic Copolymer Coating or equivalent applied to the exposed side and bottom of the beams. Beams must be delivered with bridge rail attached. Plank beam lab reports must accompany the shipping ticket.
Specifications
Commodity Code
30101700
Quantity
236.00000
Unit of Measure
SF
Delivery Date
-
View Purchase History
Additional Information
3
Pads must be 1-1/4 inches X 4-3/4 inches X 28 inches
Specifications
Commodity Code
30101700
Quantity
10.00000
Unit of Measure
EA
Delivery Date
-
View Purchase History
Additional Information
4
Pads must be 1-1/4 inches X 4-3/4 inches X 15-1/2 inches.
Specifications
Commodity Code
30101700
Quantity
4.00000
Unit of Measure
EA
Delivery Date
-
View Purchase History
Additional Information
5
Bolt or rebar must be 1 inch X 2 feet 0 inches.
Specifications
Commodity Code
30101700
Quantity
12.00000
Unit of Measure
EA
Delivery Date
-
View Purchase History
Additional Information
6
Joint filler must be 1-1/2 inches thick. Joint filler must be 4-3/4 inches X 1 feet 8-3/4 inches.
Specifications
Commodity Code
30101700
Quantity
8.00000
Unit of Measure
EA
Delivery Date
-
View Purchase History
Additional Information
7
Joint filler must be 1-1/2 inches thick. Joint filler must be 4-3/4 inches X 1 feet 6-7/8 inches.
Specifications
Commodity Code
30101700
Quantity
4.00000
Unit of Measure
EA
Delivery Date
-
View Purchase History
Additional Information
8
Joint filler must be 1-1/2 inches thick. Joint filler must be 6-5/8 inches X 4 feet 0-5/8 inches.
Specifications
Commodity Code
30101700
Quantity
12.00000
Unit of Measure
EA
Delivery Date
-
View Purchase History
Additional Information
9
Joint filler must be 1 inches thick. Joint filler must be 1 feet 0-1/4 inches X 4 feet 0-5/8 inches.
Specifications
Commodity Code
30101700
Quantity
12.00000
Unit of Measure
EA
Delivery Date
-
View Purchase History
Additional Information
10
Joint filler must be 1 inches thick. Joint filler must be 1 feet 0-1/4 inches X 1 feet 10-1/4 inches.
Specifications
Commodity Code
30121703
Quantity
4.00000
Unit of Measure
EA
Delivery Date
-
View Purchase History
Additional Information
11
Washer must have 3-1/2 inch holes. Washer must be 8 inches X 8 inches X 1 inch thick.
Specifications
Commodity Code
30121703
Quantity
15.00000
Unit of Measure
EA
Delivery Date
-
View Purchase History
Additional Information
12
Bridge rail must conform to the standards set for in section 607 of the West Virginia Division of Highways Standard Specifications of Roads and Bridges (adopted 2023). Bridge rail must include all inserts, hardware, posts, and guardrail (see plans for detail).         Bridge rail (8 bridge guardrail posts & 16 inserts with hardware, and 62-1/2 linear feet of guardrail) must be attached to beams by fabricator. Note: Shipping constraints may limit the length of attached guardrail.
Specifications
Commodity Code
30121703
Quantity
62.50000
Unit of Measure
LF
Delivery Date
-
View Purchase History
Additional Information
13
Bearing plates must be 6 pieces - 9 inches X 9 inches X 1 inch thick.
Specifications
Commodity Code
30121703
Quantity
6.00000
Unit of Measure
EA
Delivery Date
-
View Purchase History
Additional Information
14
Post tension bar must be 1 inch diameter.         Post tension bar must be 3 pieces - 27 feet 3-3/4 inches long. Post tension bar must come with nuts.
Specifications
Commodity Code
30121703
Quantity
82.00000
Unit of Measure
LF
Delivery Date
-
View Purchase History
Additional Information
Daily notification on new contract opportunities

With GovernmentContracts, you can:

  • Find more opportunities and win more business
  • Receive daily alerts for all new bid opportunities
  • Get contract opportunities matched to your business
ONE WEEK FREE TRIAL
* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.