Addendum No. 2
Administration Offices
3115 Pole Line Road
Pocatello, Idaho 83201
April 3, 2026
RE:
2026 Security Camera Replacement at Various District Sites
FROM:
Business Services
(208) 235-3270
This Addendum becomes a part of the Contract Documents and modifies the original Bidding
Specifications, as noted below. This addendum consists of one (1) page. You must acknowledge
the Addendum on the Bid Proposal sheet. Failure to acknowledge Addendum(s) on the bid
sheet may subject the bidder to disqualification.
GENERAL NOTES THAT APPLY TO ALL OF THE BID ITEMS
1. On page 3 of the specification, additional clarification is indicated below in red.
1. Contractor is responsible for the removal of all existing security cameras, which includes
patch and repair and restoration of the areas in the building affected by the project to pre-
project condition. All Cabling to be abandoned in place (cut back and cover).
REQUIREMENT FOR REPLACEMENT OF SECURITY EQUIPMENT AT VARIOUS BUILDINGS
1. On page 9 of the specification under “Bid Options”, additional clarification is indicated below in
red.
1. Install OpenEye only. OpenEye Servers to be configured for thirty (30) days of onboard
storage.
2. Pull ethernet drops to every camera. Install Plenum CAT6 cable only for all cameras.
3. Install cameras at every drop. The District will supply the modular panels and the HD jacks
for the project, however the bidder/installers will be responsible for the terminations and
certification of the cable. Jumpers are to be supplied by the installers, and will be
responsible for patching them into the existing switches that are at all sites.
4. All conduit is to be ¾” with labels turned away from sight. Painting of conduit will not be
necessary.
5. Wiremold is not acceptable.
NO OTHER CHANGES
END OF ADDENDUM No. 2 – April 3, 2026, js
1|P a g e
Addendum 2, Security Cameras 2026