6632--Chemistry CPRR with Automation

Location: Federal
Posted: Apr 27, 2026
Agency: VETERANS AFFAIRS, DEPARTMENT OF
Type of Contract: Awards
Type of Government: Federal
Category:
  • 66 - Instruments and Laboratory Equipment
Solicitation No: 36C24826AP2936
Publication URL: To access bid details, please log in.
Follow
6632--Chemistry CPRR with Automation
Active
Contract Opportunity
Notice ID
36C24826AP2936
Related Notice
Contract Line Item Number
Department/Ind. Agency
VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier
VETERANS AFFAIRS, DEPARTMENT OF
Office
248-NETWORK CONTRACT OFFICE 8 (36C248)
Award Details
  • Contract Award Date: Mar 31, 2026
  • Contract Award Number: 36F79719D002436C24826N0460
  • Task/Delivery Order Number:
  • Contractor Awarded Unique Entity ID: NH3LDK8CFAK7
  • Contractor Awarded Name: ABBOTT LABORATORIES INC.
  • Contractor Awarded Address: ABBOTT PARK , IL 60064
  • Base and All Options Value (Total Contract Value): $3,378,770.75
General Information
  • Contract Opportunity Type: Award Notice (Original)
  • Original Published Date: Apr 27, 2026 03:08 pm EDT
  • Inactive Policy: Manual
  • Original Inactive Date: May 27, 2026
  • Initiative:
    • None
Classification
  • Original Set Aside:
  • Product Service Code: 6632 - ANALYSIS INSTRUMENTS, MEDICAL LABORATORY USE
  • NAICS Code:
    • 334516 - Analytical Laboratory Instrument Manufacturing
  • Place of Performance:
    ,
Description


STATEMENT OF NEED
Clinical Chemistry CPRR with Automation System
SCOPE:
The contractor shall provide Clinical Chemistry and Immunochemistry cost-per-reportable-result (CPRR) with clinical laboratory automation with instrumentation and software for an integrated, automated platform for flexibility, simplicity and improved productivity for the Tampa VA Healthcare Network (TVAHCN), Department of Pathology and Laboratory Medicine Service (P&LMS) locations:
James A. Haley Veterans Hospital (JAHVH), 13000 Bruce B. Downs Blvd., Tampa, Florida 33612
New Port Richey VA Outpatient Clinic (NPROPC), 7900 Little Road, New Port Richey, FL 34654
Lakeland Community-Based Outpatient Clinic (LCBOC), 2080 Meadowland Park Blvd, Lakeland, FL 33803
Temple Terrace VA Clinic and Mental Health Facility (TTMHF), 8451 Temple Terrace Highway Tampa, FL 33637
All work is to be performed in accordance with the guidelines established by Federal, State and local ordinances, with the FDA and manufacturer's guidelines, and with all terms, conditions, provisions, schedules and specifications provided herein.
The Government intends to award an Firm-Fixed Price contract for the following Periods of Performance (POP): 04/01/2026 03/31/2027

REQUIRED TEST MENU:

Description Cost Per Reportable Result
Product List
Number
Reportable Annual
Volume
Alinity c Acetaminophen Reagent
07P54
997
Alinity c Albumin (BCG) Reagent
04U30
201,531
Alinity c Alkaline Phosphatase Reagent
08P20
187,099
Alinity c Alpha-1 Antitrypsin Reagent
01R07
1,670
Alinity c ALT, Activated (Alanine Aminotransferase) Reagent
08P18
188,459
Alinity c Amikacin Reagent
09P44
147
Alinity c Ammonia Reagent
08P22
1,887
Alinity c Amphetamine/ Methamphetamine Reagent
09P45
25,366
Alinity c Amylase Reagent
07P58
2,595
Alinity c AST, Activated (Aspartate Aminotransferase) Reagent
08P23
188,641
Alinity c Barbiturates Reagent
09P51
25,292
Alinity c Benzodiazepines Reagent
09P52
25,296
Alinity c Buprenorphine Reagent
04Z42
2,266
Alinity c Calcium Reagent
07P57
249,924
Alinity c Cannabinoids Reagent
09P54
25,389
Alinity c Carbamazepine Reagent
08P58
274
Alinity c Carbon Dioxide (CO2) Reagent
07P72
250,227
Alinity c Ceruloplasmin Reagent
09P93
1,291
Alinity c Cholesterol Reagent
04T88
113,855
Alinity c CK (Creatine Kinase) Reagent
08P42
4,693
Alinity c Cocaine Reagent
09P55
25,483
Alinity c Complement C3 Reagent
09P56
793
Alinity c Complement C4 Reagent
09P57
815
Alinity c Creatinine (Jaffe) Reagent
04T91
343,810
Alinity c CRP (Vario) Reagent
07P56
20,544
Alinity c Digoxin Reagent
08P37
369
Alinity c Direct Bilirubin Reagent
07P97
186,977
Alinity c Direct LDL Reagent
07P71
69,690
Alinity c Electrolytes Reagent
09D28
354,249
Alinity c Ethanol Reagent
08P41
28,913
Alinity c Fentanyl Reagent
04Z44
25,736
Alinity c Gentamicin Reagent
08P55
176
Alinity c GGT (Gamma-Glutamyl Transferase) Reagent
04T96
1,708
Alinity c Glucose Reagent
07P55
249,180
Alinity c Haptoglobin Reagent
09P59
921
Alinity c HDL (Ultra) Reagent
07P75
113,456
Alinity c Hemoglobin A1c (Monitoring & Diagnostics) Reagent
08P43
202,588
Alinity c Immunoglobulin A (IgA) Reagent
09P61
3,493
Alinity c Immunoglobulin G (IgG) Reagent
09P62
3,669
Alinity c Immunoglobulin M (IgM) Reagent
09P63
3,820
Alinity c Iron Reagent
04T98
16,087
Alinity c Lactate Dehydrogenase (LD) Reagent
07P74
3,284
Alinity c Lipase NG Open Channel Reagent
04Y85
5,390
Alinity c Lithium Reagent
08P53
1,255
Alinity c LPa Reagent
01R14
54,713
Alinity c Magnesium Reagent
08P19
70,172
Alinity c Methadone Reagent
09P64
462
Alinity c Microalbumin (Urine) Reagent
08P04
59,656
Alinity c Opiates Reagent
09P65
25,335
Alinity c Oxycodone Reagent
04Z45
26,112
Alinity c Phenobarbital Reagent
09P85
138
Alinity c Phenytoin Reagent
08P54
278
Alinity c Phosphorus Reagent
04U03
36,255
Alinity c Prealbumin Reagent
09P86
3,305
Alinity c Protein (Urine/CSF) Reagent
07P59
10,581
Alinity c Rheumatoid Factor (RF) Reagent
04R99
3,569
Alinity c Salicylate Reagent
08P59
1,066
Alinity c Theophylline Reagent
09P89
162
Alinity c Tobramycin Reagent
09P90
159
Alinity c Total Bilirubin Reagent
04U05
187,904
Alinity c Total Protein Reagent
04T81
178,490
Alinity c Transferrin Reagent
08P38
12,871
Alinity c Triglycerides Reagent
07P77
54,713
Alinity c Unsaturated Iron Binding Capacity Reagent
08P44
12,871
Alinity c Urea Nitrogen Reagent
08P16
249,342
Alinity c Uric Acid Reagent
04U09
9,365
Alinity c Valproic Acid Reagent
09P92
1,006
Alinity c Vancomycin Reagent
08P52
1,360
Alinity i Anti-HAV IgG Reagent
06S93
9,416
Alinity i Anti-HAV IgM Reagent
08P28
1,319
Alinity i Anti-HBc IgM Reagent
07P86
1,395
Alinity i Anti-HBc Reagent
07P84
6,065
Alinity i Anti-HBs Reagent
07P88
1,668
Alinity i Anti-HCV Reagent
08P05
14,911
Alinity i CA 125 II Reagent
08P49
133
Alinity i CA 19-9 (CA 19-9 XR) Reagent
08P32
907
Alinity i CEA Reagent
07P62
806
Alinity i Cortisol Reagent
08P33
3,191
Alinity i DHEA-S Reagent
09P37
303
Alinity i Estradiol Reagent
07P50
1,589
Alinity i Ferritin Reagent
07P65
18,560
Alinity i Free T3 Reagent
07P69
1,535
Alinity i Free T4 Reagent
07P70
11,106
Alinity i HBsAg (Qualitative) Reagent
08P10
9,674
Alinity i hCG (Total Beta-hCG) Reagent
07P51
1,810
Alinity i HIV Ag/Ab Combo Reagent
08P07
5,641
Alinity i Intact PTH Reagent
08P31
9,589
Alinity i NT-ProBNP Reagent
04S79
12,707
Alinity i PCT (BRAHMS) Reagent
01R18
6,674
Alinity i Progesterone Reagent
08P36
251
Alinity i PSA, Free Reagent
07P93
11,869
Alinity i PSA, Total Reagent
07P92
51,125
Alinity i SHBG Reagent
09P38
8,365
Alinity i Sirolimus Reagent
09P41
67
Alinity i STAT CK-MB Reagent
04V38
1,712
Alinity i STAT Myoglobin Reagent
04V37
379
Alinity i Tacrolimus Reagent
09P42
2,200
Alinity i Testosterone 2nd Generation Reagent
07P68
9,349
Alinity i Total T3 Reagent
07P94
3,321
Alinity i Total T4 Reagent
07P95
1,287
Alinity i Troponin-I (High Sensitive) Reagent
04Z21
15,856
Alinity i TSH Reagent
07P48
82,110
Alinity i Vitamin D Reagent
08P45
55,044
Architect IA Cyclosporine Reagent
01L75
66

Description Cost Per Test
Product List
Number
Reportable Annual
Volume
Alinity i HBsAg (Qualitative Conf.) Reagent
08P11
1,460

GENERAL REQUIREMENTS:
The contractor is required to furnish all of the following to all locations defined within the contract (Per Quoted Pricing):
Instrumentation hardware and software (analyzers, track line system, operating system, UPS, etc.).
Upgrades to and maintenance of hardware or software necessary to fulfill the test requirements.
Reagents, Calibrators, and Quality Control materials, including the use of 3rd-party Quality Control material
All consumables and user-defined replacement parts necessary to operate the contractor's equipment.
The Tampa VA Healthcare Network facilities will only pay for the patient test results reported to the patient s medical record. There shall be no minimum monthly charge.
CPRR shall be based on a tiered volume with additional savings as testing volume increases. Failure to adequately charge for estimated cost on volume as disclosed will not incur additional charges. Inflated reagent estimates if not consumed will not be charged.
Annual test volumes provided are based upon historical reported result data and are not guaranteed a minimum.
All reagents for instrument verification and test method validation, per The Joint Commission and VA guidelines, are to be supplied by the contractor at no additional cost to the government.
If at any time during the contract period, testing for the defined test menu is not available on this list, the Contractor shall provide, or reimburse the government, any additional costs associated with the procurement of another source of satisfactory test performance (i.e. reference laboratory, alternate testing instrument, etc.)

Description Annual Allowable No-Charge Consumable Quantities
Product List
Number
Annual Allowable
No-Charge Qty
Alinity c Acetaminophen Calibrator
07P54-01
3
Alinity c Acid Probe Wash
01R60-70
33
Alinity c Acid Wash Solution
08P77-40
149
Alinity c Alkaline Wash Solution
08P78-40
145
Alinity c Benzodiazepines Qualitative Calibrator Kit
09P52-01
28
Alinity c Benzodiazepines Quantitative Calibrator Kit
09P52-02
20
Alinity c Bilirubin Calibrator Kit
08P61-01
24
Alinity c Buprenorphine Calibrator
04Z42-01
28
Alinity c Buprenorphine Calibrator (0, 5,10,20, 40 ng/mL)
04Z42-02
28
Alinity c Buprenorphine Control (3.75 and 6.25 ng/mL)
04Z42-10
8
Alinity c Cannabinoids Qual Calibrator Kit
09P54-01
13
Alinity c Cannabinoids Semiquant 100 Calibrator Kit
09P54-02
13
Alinity c Cannabinoids Semiquant 200 Calibrator Kit
09P54-03
13
Alinity c Carbon Dioxide Calibrator Kit
08P72-01
20
Alinity c Consolidated Calibrator
04V62-01
8
Alinity c Acetaminophen Calibrator
07P54-01
3
Alinity c Acid Probe Wash
01R60-70
33
Alinity c Acid Wash Solution
08P77-40
149
Alinity c Alkaline Wash Solution
08P78-40
145
Alinity c Benzodiazepines Qualitative Calibrator Kit
09P52-01
28
Alinity c Benzodiazepines Quantitative Calibrator Kit
09P52-02
20
Alinity c Bilirubin Calibrator Kit
08P61-01
24
Alinity c Buprenorphine Calibrator
04Z42-01
28
Alinity c Buprenorphine Calibrator (0, 5,10,20, 40 ng/mL)
04Z42-02
28
Alinity c Buprenorphine Control (3.75 and 6.25 ng/mL)
04Z42-10
8
Alinity c Cannabinoids Qual Calibrator Kit
09P54-01
13
Alinity c Cannabinoids Semiquant 100 Calibrator Kit
09P54-02
13
Alinity c Cannabinoids Semiquant 200 Calibrator Kit
09P54-03
13
Alinity c Carbon Dioxide Calibrator Kit
08P72-01
20
Alinity c Consolidated Calibrator
04V62-01
8
Alinity c CRP Vario Cardiac High Sensitivity Calibrator Kit (US)
07P56-05
10
Alinity c CRP Vario High Sensitivity Calibrator Kit (US)
07P56-04
10
Alinity c CRP Vario Wide Range Calibrator Kit
07P56-01
10
Alinity c CRP Vario Wide Range Calibrator Kit (US)
07P56-03
10
Alinity c CRP Vario Wide Range Calibrator Kit HS
07P56-02
10
Alinity c Customer Maintenance Kit
04S46-02
8
Alinity C Cuvette Dry Tip
04S52-01
8
Alinity C Cuvette Segment
04S47-01
8
Alinity C Cuvette Segment Alignment Tool
04S70-02
8
Alinity c Detergent A
08P96-70
146
Alinity c Detergent B
08P97-81
125
Alinity c DOA MC Negative Cal Kit
08P63-06
47
Alinity c DOA MC Qual Cal 2 Kit
08P63-02
37
Alinity c DOA MC Qual Low Cal 1 Kit
08P63-01
40
Alinity c DOA MC Semiquant Cal 3 Kit
08P63-03
37
Alinity c Ethanol Calibrator Kit
08P41-01
16
Alinity c Fentanyl Calibrator (1 ng/mL)
04Z44-01
28
Alinity c Fentanyl Calibrator (Negative Urine)
04Z44-04
28
Alinity c Hemoglobin A1c Calibrator Kit
08P43-01
30
Alinity c ICT Reference Solution
08P76-40
56
Alinity c ICT Sample Diluent
07P53-20
43
Alinity c ICT Serum Calibrator Kit
08P69-01
47
Alinity c ICT Urine Calibrator Kit
08P70-01
52
Alinity c Iron Calibrator
04U75-01
10
Alinity c Lipase NG Open Channel Calibrator Kit
04Y85-01
3
Alinity c Lipid Multiconstituent Calibrator Kit
09P14-03
9
Alinity c Lp(a) Calibrator Kit
01R14-01
24
Alinity c Lp(a) Control Kit
01R14-10
2
Alinity c Maintenance Solutions (US)
08P98-71
28
Alinity c Microalbumin Calibrator Kit
08P04-04
10
Alinity c Multiconstituent Calibrator Kit
08P60-01
42
Alinity c Negative Urine Calibrator
04Z47-01
28
Alinity c Opiates Qual Calibrator Kit
09P65-01
28
Alinity c Opiates Semiquant Calibrator Kit
09P65-02
28
Alinity c Oxycodone Calibrator (0, 100, 300, 500, 1000 ng/mL)
04Z45-03
28
Alinity c Oxycodone Calibrator (100 ng/mL)
04Z45-01
28
Alinity c Oxycodone Calibrator (300 ng/mL)
04Z45-02
28
Alinity c Oxycodone Control (75, 125 ng/mL)
04Z45-11
8
Alinity c Plasmaproteins Calibrator
08P66-01
4
Alinity c Prealbumin Calibrator
04S01-01
2
Alinity c Proteins Standard Calibrator
08P67-01
1
Alinity C Reagent Probe
04S49-01
32
Alinity C Reagent Probe Screw
04S54-01
8
Alinity C Reagent Probe Tubing
04S50-01
24
ALINITY C Rgt Cartridge Black
04S17-50
8
ALINITY C Rgt Cartridge Clear
04S17-40
8
Alinity c Rheumatoid Factor (RF) Calibrator Kit (US)
04S00-02
1
Alinity c Salicylate Calibrator Kit
08P59-01
1
Alinity C Sample Probe
04S51-01
8
Alinity C Sample Probe Screw
04S53-01
8
Alinity c Sentinel Clinical Chemistry Calibrator Kit
08P65-03
9
Alinity c Specific Proteins Multiconstituent Calibrator
08P62-01
8
Alinity c TDM Multiconstituent Calibrator Kit
08P74-04
7
Alinity c Tobramycin Calibrator
09P90-01
5
Alinity c UIBC Calibrator Kit
08P44-01
2
Alinity c Urine/CSF Protein Calibrator Kit
08P71-01
2
Alinity ci Sample Cups
01R38-01
136
Alinity i 25-OH Vitamin D Calibrator Kit
08P45-01
3
Alinity i Anti-HBc Calibrator Kit (US)
07P84-01
1
Alinity i Anti-HBc IgM Calibrator Kit (US)
07P86-02
5
Alinity i Anti-HBs Calibrator Kit (US)
07P88-01
2
Alinity i Anti-HCV Calibrator Kit (US)
08P05-01
3
Alinity i CA 125 II Calibrator Kit
08P49-01
2
Alinity i CA 19-9XR Calibrator Kit
08P32-01
1
Alinity i CEA Calibrator Kit
07P62-01
1
Alinity i Common Diluent
09P15-40
4
Alinity i Concentrated Wash Buffer
06P13-68
417
Alinity i Cortisol Calibrator Kit
08P33-01
2
Alinity i Customer Maintenance Kit
04S37-02
5
Alinity i DHEA-S Calibrator Kit
09P37-01
1
Alinity i Estradiol Calibrator Kit
07P50-01
2
Alinity i Ferritin Calibrator Kit
07P65-01
3
Alinity i Free PSA Calibrator Kit
07P93-01
6
Alinity i Free T3 Calibrator Kit
07P69-01
2
Alinity i Free T4 Calibrator Kit
07P70-01
2
Alinity i HAVAb IgG Calibrator Kit (US)
06S93-01
2
Alinity i HAVAb IgM Calibrator Kit (US)
08P28-01
2
Alinity i HBSAG Qual Conf Man Diluent (US)
08P11-41
6
Alinity i HBsAg Qualitative Calibrator Kit (US)
08P10-02
6
Alinity i HIV Ag/Ab Combo Calibrator Kit (US)
08P07-02
5
Alinity i NT-proBNP (Alere) Calibrator Kit
04S79-02
7
Alinity i PCT (BRAHMS) Calibrator Kit
01R18-01
3
Alinity i Probe Conditioning Solution
01R58-40
18
Alinity i Progesterone Calibrator Kit
08P36-01
2
Alinity i Progesterone Manual Diluent
08P36-40
1
Alinity i SHBG Calibrator Kit
09P38-01
3
Alinity i Sirolimus Calibrator Kit
09P41-01
2
Alinity i Sirolimus Whole Blood Precipitation Kit
09P41-40
4
Alinity i STAT CK-MB Calibrator Kit
04V38-01
5
Alinity i STAT High Sensitive Troponin-I Calibrator (US)
04Z21-01
5
Alinity i STAT Intact PTH Calibrator Kit
08P31-02
5
Alinity i STAT Myoglobin Calibrator Kit
04V37-01
3
Alinity i STAT Total -hCG Calibrator Kit
07P51-01
4
Alinity i Tacrolimus Calibrator Kit
09P42-01
1
Alinity i Tacrolimus Whole Blood Precipitation Kit
09P42-40
44
Alinity i Testosterone Calibrator Kit
07P68-01
10
Alinity i Total PSA Calibrator Kit
07P92-01
6
Alinity i Total T3 Manual Diluent
07P94-40
2
Alinity i Total T3 Calibrator Kit
07P94-01
4
Alinity i Total T4 Calibrator Kit
07P95-01
4
Alinity i TSH Calibrator Kit
07P48-01
7
Alinity Pre-Trigger Solution (REACH)
06P12-70
50
Alinity Reaction Vessels
06P14-01
115
Alinity Reagent Replacement Caps
04R47-01
5
Alinity Trigger Solution (REACH)
06P11-70
69
Architect IA Probe
08C94-47
1
Architect IA Probe Conditioning Solution
01L56-40
1
Architect IA Reaction Vessels
07C15-03
1
Architect IA Replacement Caps
04D19-01
1
Architect IA Septums
04D18-03
1
Architect IA Trigger Solution (REACH)
06C55-63
4
Architect IA Wash Buffer 1x10L
06C54-88
32
Architect IA Wash Buffer 4x975mL
06C54-58
11
Architect IA/CC Sample Cups
07C14-01
1
ARCHITECT Pretreatment Tubes
01P06-02
6
ARCHITECT Pre-Trigger Straw
08C94-67
12
ARCHITECT Probe, Wash Zone
08C94-36
3
ARCHITECT Probe/Tubing, Waste Arm
08C94-89
1
ARCHITECT Trigger Straw
08C94-66
12
ARCHITECT Tubing Probe
08C94-49
1
ARCHITECT Tubing, STAT Probe
03M77-49
1
ARCHITECT Wash Buffer Prep Container
08C94-56
1
ARCHITECT Wash Buffer Transfer Tubing
08C94-21
1
Transplant Pretreatment Tubes
01P06-03
39
104AB EXTRNGLNRTY
03L45-02
2
MS GC1 1100AB
04P36-05
12
MS GC2 1200AB
04P36-06
17
MS GC4 1400AB
04P36-07
19
MS LP 501AB
04P47-01
13
MS THY 901AB
04P36-10
4
MS UC 1 701AB
04P39-01
10
MS UC 4 704AB
04P40-01
10
MS UC 5 705AB
04P41-01
7
MS VIT D 506
04P36-11
2
MSCHEM TDM1 301AB
04P38-01
5

Description Third-Party Products
Product List
Number
Manufacturer / Supplier
Qty
Cystatin C Reagent
06U41-25
Gentian/Abbott
107
CYSTATIN C CAL KIT 1051
06U41-01
Gentian/Abbott
0
CYSTATIN C CAL KIT 1012
06U41-02
Gentian/Abbott
55
Cystatin C Control
06U41-10
Gentian/Abbott
153
LIQCHK CRDMKR LT+2 BR14
04P11-04
BioRad
43
MULTIQUAL UNASSY L1 697
04P13-02
BioRad
18
MULTIQUAL UNASSY L3 699
04P13-04
BioRad
18
BR544 ETH/NH3 1
04P14-01
BioRad
20
BR546 ETH/NH3 3
04P14-03
BioRad
20
LIQCHK IA PLUS CTL, L1
04P15-01
BioRad
27
LIQCHK IA PLUS CTL, L3
04P15-02
BioRad
27
BR594 IMMUNO 1
04P16-01
BioRad
18
BR595 IMMUNO 2
04P16-02
BioRad
18
BR596 IMMUNO 3
04P16-03
BioRad
18
LIQCK SPEC IA CTL 1
04P17-03
BioRad
18
LIQCK SPEC IA CTL 2
04P17-04
BioRad
18
LIQCHK SPEC IA CTL, L3
04P17-05
BioRad
18
BR355 PEDIATRIC 2
04P19-02
BioRad
13
LIQCK TUMOR MRKR CTL 1
04P19-05
BioRad
18
LIQCK TUMOR MRKR CTL 3
04P19-07
BioRad
18
LIQCK SPINAL FLD CTL L1
04P21-01
BioRad
24
LIQCK SPINAL FLD CTL L2
04P21-02
BioRad
24
BR397 CHEM1
04P22-01
BioRad
17
BR398 CHEM2
04P22-02
BioRad
17
MICROALBMN CTL LVL1 378
04P23-13
BioRad
6
MICROALBMN CTL LVL2 379
04P23-14
BioRad
6
LIQCHK CARD MRKR CTL L2
04P23-19
BioRad
43
LIQCK URINE TOX NEG CTL
04P25-01
BioRad
7
LIQCK URINE TOX S1E CTL
04P27-02
BioRad
7
LIQ CARDIAC MRK+ CTL
04Z52-02
BioRad
43

EQUIPMENT SYSTEM TECHNICAL SPECIFICATIONS AND FEATURES:
The Contractor will continue to provide the following list of equipment (Equipment Rental) for the terms of the contract (billed monthly) and Contractor agrees to service and maintain the list of equipment per the manufacturer s published FDA-approved specifications.
James A. Haley Veterans Hospital:
Alinity C Modules 4 Each
Alinity I Modules 2 Each
Architect 1 Each
Automation System Components:
IOM Module with Software System 1 Each
Centrifugation Modules 2 Each
Refrigerated Storage Module 1 Each
Specimen Decappers 2 Each
Specimen Sealers 2 Each
Automation Track Components (complete system) 1 Each
Automation System Software Operating System (Data Innovations) 1 Each
DI Water System 1 Each
New Port Richey VA Outpatient Clinic:
Alinity C Modules 1 Each
Alinity I Modules 1 Each
DI Water System 1 Each
Description Existing Equipment Monthly Rental
(Abbott-Owned / Serviced by Abbott)
List
Number
Quantity Installed
a3600 (Automation System) NO ANNUAL FEE
06P33-01
1
Alinity i Analyzer (James A Haley)
03R67-01
2
Alinity c Analyzer (James A Haley)
03R65-01
4
Alinity i Analyzer (New Port Richey Outpatient Clinic)
03R67-01
1
Alinity c Analyzer (New Port Richey Outpatient Clinic)
03R65-01
1
Architect i2000 Analyzer (James A Haley) NO ANNUAL FEE
03M74-02
2

The Government will furnish the following list of equipment, and the Contractor agrees to service and maintain the list of equipment per the manufacturer s published FDA-approved specifications.
Lakeland Community-Based Outpatient Clinic:
Alinity C Modules 1 Each
Alinity I Modules 1 Each
DI Water System 1 Each
Temple Terrace VA Clinic and Mental Health Facility
Alinity C Modules 2 Each
Alinity I Modules 1 Each
DI Water System 1 Each
Description Existing Equipment
(Government-Owned / Serviced by Abbott)
List
Number
Quantity Installed
Alinity i Analyzer (JAH VA Mental Health)
03R67-01
1
Alinity c Analyzer (JAH VA Mental Health)
03R65-01
2
Alinity i Analyzer (Lakeland VA Clinic)
03R67-01
1
Alinity c Analyzer (Lakeland VA Clinic)
03R65-01
1

Miscellaneous Services Performed by Abbott on an As-Needed Basis
Water System Maintenance (Included in CPRR Pricing No Charge
Ancillary Items Included in the CPRR pricing (No-Charge)
Quantity
Water System Maintenance- JAH VA Mental Health CLX 7080 / Model Number: ZAFS61080
1
Water System Maintenance- Lakeland VA Clinic CLX 7080 / Model Number: ZAFS61080
1
Water System Maintenance- New Port Richey CLX 7080 /Model Number: ZAFS61080
1
Water System Maintenance- JAH VA Hospital CLX 7150 Model Number: ZAFS62150
1

Quarterly Maintenance by Abbott Service Personnel Billed per Item
Ancillary Items Included in the CPRR pricing (No-Charge)
List Number
Quantity
a3600 Automation (James A Haley) - Same Day Response - 24x7
01DM9-02 / 01DM9-25
1
Alinity i Analyzer (James A Haley)- Same Day Response - 24x7
01DP5-02 / 01DP5-25
1
Alinity c Analyzer (James A Haley)- Same Day Response - 24x7
01DP4-02 / 01DP4-25
1
Architect i2000 Analyzer (James A Haley)- Same Day Response
01DL6-02
1
Alinity i Analyzer (New Port Richey Outpatient Clinic)- Same Day Response
01DP5-02
As-Needed Instrument Manager Advisory Service Billed per Item
Ancillary Items Included in the CPRR pricing
List Number
QTY
IM Advisory Service - On-site (Days)
01DD4-42
2
IM Advisory Service - Remote (Hours)
01DD4-40
16

Abbott Always On In-Lab Services
Description
List Number
Qty
a3600 Automation (James A Haley) - Same Day Response - 24x7
01DM9-02 / 01DM9-25
1
Alinity i Analyzer (James A Haley)- Same Day Response - 24x7
01DP5-02 / 01DP5-25
2
Alinity c Analyzer (James A Haley)- Same Day Response - 24x7
01DP4-02 / 01DP4-25
4
Architect i2000 Analyzer (James A Haley)- Same Day Response
01DL6-02
2
Alinity i Analyzer (New Port Richey Outpatient Clinic)- Same Day Response
01DP5-02
1
Alinity c Analyzer (New Port Richey Outpatient Clinic)- Same Day Response
01DP4-02
1
Alinity i Analyzer (JAH VA Mental Health)- Same Day Response
01DP5-02
1
Alinity c Analyzer (JAH VA Mental Health)- Same Day Response
01DP4-02
2
Alinity i Analyzer (Lakeland VA Clinic)- Same Day Response
01DP5-02
1
Alinity c Analyzer (Lakeland VA Clinic)- Same Day Response
01DP4-02
1

Abbott AlinIQ Monthly Service
Description
List Number
Qty
Instrument Manager Subscription (James A Haley)
01P63-78
1
Instrument Manager Always On Support Contract (James A Haley)
01DN8-02
1
Instrument Manager Always On Support Contract (New Port Richey Outpatient Clinic)
01DN8-02
1
Instrument Manager Always On Support Contract (Lakeland VA Clinic)
01DN8-02
1
Instrument Manager Always On Support Contract (JAH VA Mental Health)
01DN8-02
1

Upgrades / Replacement of Equipment within the TLA System: Request for upgrades or replacement hardware/software, due to workload increase, excessive instrumentation failures will be evaluated as needed or at least annually with communication to the Contractor for modification of the contract. A high incidence of such problems with any equipment/analyzer or assay within the test menu supplied may indicate probable non-compliance with the terms of this contract and will entitle the government to its replacement with other analyzer(s) that can produce the required criteria of this contract satisfactorily.
Downtime is defined as any time the equipment is not available for patient testing due to malfunction, unacceptable quality control, software system errors, or hardware failures. This includes time used for end-user troubleshooting, conversations with technical support or on-site engineer repair/support.
Standard acceptable performance for the life of the contract, following acceptance as defined in section below, is defined as a period of 30 consecutive calendar days by operating in conformation with the contractor's technical specification without prolonged downtime (>4 hours) per instance more than 3 times within 30 days or more than 10 instances of downtime (of any length of time) within 30 days. In the event the equipment or an assay does not meet the standard acceptable performance for 30 consecutive days, the government will notify the contractor of the ongoing unacceptable performance and the performance will be monitored for an addition 90 consecutive days. If after 120 calendar days from the initial date of unacceptability, the vendor does not resolve the performance concerns to meet the governments expectations, the government, through the contracting officer, may request a replacement of the equipment / assay or terminate the order upon mutual agreement.
Removal of the existing instrument by the Contractor shall be performed within 30 days following the acceptance of replacement equipment without additional charge to the government.
Enhancements to the contractor's equipment shall be delivered to the government site and installed by the contractor within 60 days of their issuance or date of first commercial availability.
The Contractor shall provide all upgrades to the equipment hardware and operating system software without additional charge to the government.

Adding New Assays to the Existing Analyzers: A contract modification may be used to add additional assays to the existing test menu at any time during the contract period. Upon completion of the modification, the contractor is responsible for the assay installation and validation in accordance with Section 2, General Requirements for a CPRR contract. The assay shall be acceptable for use within 30 days from the completion of the contract modification.
SYSTEM DATA MANAGEMENT HARDWARE / SOFTWARE
The Data Management System must include a test environment and product account. The contractor is responsible for assisting the government with the initial virtual server build and on-going maintenance of both servers.
The system must have sufficient data storage for 2 years of workload data and provide immediate access to more than 7,500 patient records per day, including instrument identification (houses PHI and PII).
The Contractor s equipment shall be compatible, or have the ability to, act as a pass-through to the government s Data Innovations (DI) Instrument Manager for instances when the government s DI is the primary rule management software. DI connection is not required for vendor s who connect directly to the government s LIS and when the vendor s middleware is the primary rule management software.
As a responsible owner of the track operating system, the contractor is responsible for assisting the government with track software modifications (i.e. routing rules) when 3rd-party connections are added and/or modified.
The vendor must provide all printers, including all components for printer functionality (printer drivers) and printing (excluding toner and printer paper).
The contractor and lab information manager must have remote access connectivity for troubleshooting systems, interface connections, and analyzers. Contractors require network access to the instruments and to the interface manager.
The contractor s system software must include a comprehensive Quality Control Data Manager or provide compatibility with Bio-Rad Unity Real Time Quality Control (QC) program. The proposed system must include real-time reports, printable monthly reports, and peer-group evaluations with like controls, instruments and assays.
All software and software licenses, interfaces, and hardware (e.g. servers, printers, print drivers, monitors, UPS, etc.) shall be included with cost of hardware required disclosed for removal if needed.
Procurement of systems with unsupported operating systems is prohibited. Unsupported operating systems are software systems that are not supported by the manufacturer and have reached the end of the OS lifecycle as published by the OS manufacturer (i.e., no further security patches will be released for the OS by the manufacturer after the OS end of life nor will be available by other methods such as extended warranty purchases from the OS manufacturer). If the proposed medical device runs an unsupported OS, the medical device vendor must provide a support plan for the device (i.e., purchase of extended warranty from the OS manufacturer, an upgrade path to a supported OS, etc.) prior to deployment of the system. Contractor is responsible for maintaining operating system software in compliance with VA TRM (Technical Reference Model) and agrees to upgrade or replace the OS for ongoing approval with OI&T and BioMed network guidelines.
The Contractor is responsible for, at no cost to the government, any upgrades to any unsupported or unapproved operating systems on contractor-owned data management system or equipment. The contractor agrees to assist the Government with major software modifications and upgrades to meet changes in VA OI&T guidelines or laboratory operations. (per Contractors Fee Schedule/Quote).
PREVENTATIVE MAINTENANCE:
The contractor shall provide maintenance, at their expense (travel, labor and parts), to keep the equipment in good operating condition and subject to security regulations. The government shall provide the contractor access to the equipment to perform maintenance services.
The preventive maintenance shall be of a frequency that conforms to the manufacturer's operation and maintenance instructions for the supported equipment.
Contractor shall have remote access to system for troubleshooting purposes.
The contractor is responsible for performing quarterly preventative maintenance per the quoted pricing, including expenses for (travel, labor and parts).
SERVICE AND SUPPORT:
Contractor shall provide full service on-site technical support Monday Friday, 8:30 am 5:00 pm local time for all equipment, including the track automation system, to keep the equipment in good operating condition and subject to security regulations.
Telephone technical support shall be available 24 hours/day, 7 days/week with follow up on all calls within one hour of initial call. Following determination that service is required, technical on-site support must be provided within 24 hours.
The government shall provide the contractor access to the equipment to perform the repair.
The contractor will provide all parts and labor needed to repair the malfunction.
Travel, per diem and other expenses associated with the repair will be borne by the contractor.
The contractor shall furnish a malfunction incident report to the institution upon completion of each maintenance call. The report shall include, as a minimum, the following: (a date and time of notification, (b) date and time of arrival, (c) serial number type and model number(s) of equipment, (d) time spent for repair, (e) description of malfunction and (f) proof of repair. Parts (e) and (f) shall be written verification of quality control for a sample run.
DELIVERY, PERFORMANCE, INSPECTION AND ACCEPTANCE
(In the event new equipment / tests are installed during the life of the contract):
General:
The Contractor is responsible for performing all inspections and tests necessary to substantiate that the equipment, supplies and services furnished under the contract conform to contract requirements. The VA has the right to test all services ordered under the contract at all times and places throughout the term of the contract Government testing and inspection will not unduly delay any Contractor work being performed nor will it create a defect in services covered by this contract.
The VA reserves the right to thoroughly inspect and investigate the contractor and manufacturer business reputations and other qualifications, and to reject any bid, irrespective of price, that shall be administratively determined lacking in any of the essentials necessary to assure acceptable standards of performance.
Returned goods: The VA is responsible for inspecting all products shipped hereunder and will give the contractor written notice of rejection within thirty (30) calendar days following receipt or installation by the contractor.
Standard and Acceptance of performance shall begin on the installation date. It shall end on the earlier date of when a certificate of acceptance has been signed or the equipment has met the standard of performance for a period of 30 consecutive calendar days by operating in conformation with the contractor's technical specification or as quoted in any contract at an effectiveness level of 90% or more. In the event the equipment does not meet the standard of performance during the initial 30 consecutive calendar days, the standard of performance test shall continue on a day-by-day basis until the standard of performance is met for a total of 30 consecutive days. If the equipment fails to meet the standard of performance after 90 calendar days from the installation date, the user may, at his/her option, request a replacement or terminate the order upon mutual agreement.
Operational use time for performance testing for a system is defined as the accumulated time during which the machine is in actual use. System failure downtime is that period of time when any machine in the system is inoperable due to equipment failure. Downtime for each incident shall start from the time the government makes a bona fine attempt to contact the contractor's designated representative at the prearranged contact point until the system or machine(s) is returned to the government in proper operating condition.
During the performance period for a system, a minimum of 100 hours of operational use time with productive or simulated work will be required as a basis for computation of the effectiveness level. However, in computing the effectiveness level, the actual number of operational use hours shall be used when in excess of the minimum of 100 hours. The government shall maintain appropriate daily records to satisfy the requirements of this paragraph and shall notify the contractor in writing of the date of the first day of the successful performance period. Operations use time and downtime shall be measured in hours and whole minutes.
Government's Responsibility: The user will perform daily and weekly routine operation maintenance and cleaning as required in the manufacturer's operation and maintenance instructions. The user shall maintain appropriate daily records to satisfy the requirements of this paragraph.

Equipment:
Acceptance will normally be consummated upon delivery and, when applicable, installation and completion of personnel training.
The VA reserves the right to request a ninety (90) day test and evaluation of all pieces of equipment prior to placing a delivery order under the contract. If the test and evaluation is not successful as determined by the CO and COR, the VA will not be required to continue with placing a delivery order under this contract, and no default or penalty will accrue.
The contractor shall be responsible for installation, which consists of in-house delivery, positioning and mounting of all equipment listed on the delivery order and connections of all equipment and interconnecting wiring and cabling if applicable. Upon receipt of notice to proceed with installation, it shall be the contractor's responsibility to inform the Contracting Officer of any problems which may be anticipated in connection with installation or which will affect optimum performance once installation is completed. In the event that progress of the installation is interrupted through no fault of the contractor, the continuous installation referenced in the preceding paragraphs may be terminated until such time as the cause of delay has been eliminated, and then shall be resumed within 24 hours after the contractor has been notified that work may again proceed.
Upon completion of installation the equipment will be turned over to the hospital for use. Final acceptance of the equipment and installation will be based upon an inspection and test to be performed within ten (10) calendar days from date of installation. If equipment passes inspection or if acceptance inspection is not conducted within ten (10) calendar days from installation, the Government shall accept installation with guarantee date commencing ten calendar days after installation.
The contractor will provide all operational upgrades to the equipment hardware and operating system software that materially affects the performance of the equipment, without additional charge to the government. These enhancements to the contractor's equipment shall be delivered to the government site and installed by the contractor within 60 days of their issuance or date of first commercial availability.
Ownership of Equipment shall remain with the contractor. All equipment accessories (hardware and software) furnished by the contractor shall accompany the equipment when returned to the contractor. The contractor, upon expiration of order(s) at termination and/or replacement of equipment, will remove the equipment. The contractor will disconnect the equipment and will be responsible for all packing and shipping required to remove the equipment within ten business days. The hard drive will remain within the VA.

Reagents/Supplies/Consumables:
The VA shall require the delivery of reagents for all services required under this contract. The contractor shall deliver reagents, shipping cost included (with the exception of fault by the Government), as needed (including emergency over-night delivery orders) from CALL orders within 24 hours.
The contractor will assure that all supplies provided/ordered for use on their equipment will be of the quality necessary to produce a quality result. The reagent quality must be high enough to satisfy proficiency testing standards of the College of American Pathologists (CAP) and The Joint Commission.
In the event that the supplies, to include consumables, are found to be defective and unsuitable for use with the contractor's equipment or the contractor has failed to comply with the requirements herein, the contractor is required to deliver the supplies within 24 hours of receipt of the verbal order for priority delivery from the government activity. This will be done at no cost to the government and in sufficient quantity as required to allow operation of the contractor's equipment for one week (under normal government test load volume).
The Contractor is required to provide a continuously stocked inventory of reagents, calibrators, troubleshooting controls, required consumable supplies including all routinely replaced parts, disposables and any other materials required to properly perform tests on the equipment. Unexpected changes in methodology or technology will be at the expense of the Contractor. Alert and Notification of all technical advisory recalls and, or alerts, prior to or simultaneously with field alerts should be
forwarded to Laboratory Supervisor and the Laboratory Manager. On or about the first day of each month, the contractor will ensure that each site is furnished with sufficient consumable supplies to produce a volume of tests for that month. Separate deliveries of products will be shipped to each testing site, as applicable. Failure to reserve adequate inventory will result in default.
If additional requests for emergency supply delivery are required by the government, the contractor shall honor them until the arrival of the monthly standing order and routine supplies are delivered.
All deliveries (routine and emergent) of reagents, supplies, consumables must be delivered directly to the laboratory at the expense of the contractor.

TRAINING: The contractor, without additional charge to the government, shall provide training off-site for at least two (2) key operating personnel per instrument module installed and all automation system components during the life of the agreement.

REGULATORY REQUIREMENTS: If the product(s) included in this solicitation/contract, are considered medical devices by the US Food and Drug Administration, the manufacturer shall be in compliance with the Food, Drug and Cosmetic Act, as amended, and regulations promulgated there under.

TECHNICAL INDUSTRY STANDARDS: The contractor certifies that all applicable equipment offered under this contract shall conform to all common industry standards.

MANUFACTURED PRODUCTS: Materials furnished shall be of the current productions of manufacturers regularly engaged in manufacture of such items. Approval by Contracting Officer is required of deviation from products and manufacturers as shown in the schedule of items. Shelf-life of all consumables shall be at least ONE YEAR from shipping date unless FDA requires different expiration date.

REFERENCE SPECIFICATIONS AND PUBLICATIONS: Where an item is required to conform to certain requirements, conformance shall be evidenced by seal, label, stamp, or approval listing from such agency, or by a certified test report from an independent testing laboratory acceptable to the Government, that the item has been tested and conforms to requirements of referenced agency.

RECALLS: If at any time during the term of the contract, the FDA or the Contractor, or subcontractor initiates an item recall or FDA withdraws its approval to manufacture an item, the contractor will issue a notice to indicate the complete item description and identification of the recall with necessary instructions for return for credit or replacement.

CONTRACT ADMINISTRATION DATA: The Contracting Officer is the only person authorized to approve changes or modify any of the requirements under this contract The Contractor shall communicate with the Contracting Officer on all matters pertaining to contract administration. Only the Contracting Officer is authorized to make commitments or issue changes, which will affect price, quantity, or quality of performance of this contract. In the event the contractor effects any such change at the direction of any person other than the contracting officer, the change shall be considered to have been made without authority

RECORDS MANAGEMENT OBLIGATIONS

Applicability
This clause applies to all Contractors whose employees create, work with, or otherwise handle Federal records, as defined in Section B, regardless of the medium in which the record exists.
Definitions
Federal record as defined in 44 U.S.C. § 3301, includes all recorded information, regardless of form or characteristics, made or received by a Federal agency under Federal law or in connection with the transaction of public business and preserved or appropriate for preservation by that agency or its legitimate successor as evidence of the organization, functions, policies, decisions, procedures, operations, or other activities of the United States Government or because of the informational value of data in them.
The term Federal record:

includes James A. Haley Veterans Hospital System records.
does not include personal materials.
applies to records created, received, or maintained by Contractors pursuant to their James A. Haley Veterans Hospital contract.
may include deliverables and documentation associated with deliverables.
Requirements
Contractor shall comply with all applicable records management laws and regulations, as well as National Archives and Records Administration (NARA) records policies, including but not limited to the Federal Records Act (44 U.S.C. chs. 21, 29, 31, 33), NARA regulations at 36 CFR Chapter XII Subchapter B, and those policies associated with the safeguarding of records covered by the Privacy Act of 1974 (5 U.S.C. 552a). These policies include the preservation of all records, regardless of form or characteristics, mode of transmission, or state of completion.
In accordance with 36 CFR 1222.32, all data created for Government use and delivered to, or falling under the legal control of, the Government are Federal records subject to the provisions of 44 U.S.C. chapters 21, 29, 31, and 33, the Freedom of Information Act (FOIA) (5 U.S.C. 552), as amended, and the Privacy Act of 1974 (5 U.S.C. 552a), as amended and must be managed and scheduled for disposition only as permitted by statute or regulation.
In accordance with 36 CFR 1222.32, Contractor shall maintain all records created for Government use or created in the course of performing the contract and/or delivered to, or under the legal control of the Government and must be managed in accordance with Federal law. Electronic records and associated metadata must be accompanied by sufficient technical documentation to permit understanding and use of the records and data.
The Healthcare System and its contractors are responsible for preventing the alienation or unauthorized destruction of records, including all forms of mutilation. Records may not be removed from the legal custody of James A. Haley Veterans Hospital or destroyed except for in accordance with the provisions of the agency records schedules and with the written concurrence of the Head of the Contracting Activity. Willful and unlawful destruction, damage or alienation of Federal records is subject to the fines and penalties imposed by 18 U.S.C. 2701. In the event of any unlawful or accidental removal, defacing, alteration, or destruction of records, Contractor must report to James A. Haley Veterans Hospital. The agency must report promptly to NARA in accordance with 36 CFR 1230.
The Contractor shall immediately notify the appropriate Contracting Officer upon discovery of any inadvertent or unauthorized disclosures of information, data, documentary materials, records or equipment. Disclosure of non-public information is limited to authorized personnel with a need-to-know as described in the contract. The Contractor shall ensure that the appropriate personnel, administrative, technical, and physical safeguards are established to ensure the security and confidentiality of this information, data, documentary material, records and/or equipment is properly protected. The Contractor shall not remove material from Government facilities or systems, or facilities or systems operated or maintained on the Government s behalf, without the express written permission of the Head of the Contracting Activity. When information, data, documentary material, records and/or equipment is no longer required, it shall be returned to James A. Haley Veterans Hospital control or the Contractor must hold it until otherwise directed. Items returned to the Government shall be hand carried, mailed, emailed, or securely electronically transmitted to the Contracting Officer or address prescribed in the contract. Destruction of records is EXPRESSLY PROHIBITED unless in accordance with Paragraph (4).
The Contractor is required to obtain the Contracting Officer's approval prior to engaging in any contractual relationship (sub-contractor) in support of this contract requiring the disclosure of information, documentary material and/or records generated under, or relating to, contracts. The Contractor (and any sub-contractor) is required to abide by Government and VA Healthcare System guidance for protecting sensitive, proprietary information, classified, and controlled unclassified information.
The Contractor shall only use Government IT equipment for purposes specifically tied to or authorized by the contract and in accordance with James A. Haley Veterans Hospital policy.
The Contractor shall not create or maintain any records containing any non-public James A. Haley Veterans Hospital information that are not specifically tied to or authorized by the contract.
The Contractor shall not retain, use, sell, or disseminate copies of any deliverable that contains information covered by the Privacy Act of 1974 or that which is generally protected from public disclosure by an exemption to the Freedom of Information Act.
The James A. Haley Veterans Hospital owns the rights to all data and records produced as part of this contract. All deliverables under the contract are the property of the U.S. Government for which James A. Haley Veterans Hospital shall have unlimited rights to use, dispose of, or disclose such data contained therein as it determines to be in the public interest. Any Contractor rights in the data or deliverables must be identified as required by FAR 52.227-11 through FAR 52.227-20.
Flow-down of requirements to subcontractors:
The Contractor shall incorporate the substance of this clause, its terms and requirements including this paragraph, in all subcontracts under this [contract vehicle], and require written subcontractor acknowledgment of same.
Violation by a subcontractor of any provision set forth in this clause will be attributed to the Contractor.
VA INFORMATION AND INFORMATION SYSTEM SECURITY/PRIVACY LANGUAGE
VA INFORMATION CUSTODIAL LANGUAGE:
a. Contractors, contractor personnel, subcontractors, and subcontractor personnel shall be subject to the same Federal laws, regulations, standards, and VA Directives and Handbooks as VA and VA personnel regarding information and information system security.
b. If VA determines that the contractor has violated any of the information confidentiality, privacy, and security provisions of the contract, it shall be sufficient grounds for VA to withhold payment to the contractor or third party or terminate the contract for default or terminate for cause under Federal Acquisition Regulation (FAR) part 12.
c. A contractor/subcontractor shall request logical (technical) or physical access to VA information and VA information systems for their employees, subcontractors, and affiliates only to the extent necessary to perform the services specified in the contract, agreement, or task order.
d. All contractors, subcontractors, and third-party servicers and associates working with VA information are subject to the same investigative requirements as those of VA appointees or employees who have access to the same types of information. The level and process of background security investigations for contractors must be in accordance with VA Directive and Handbook 0710, Personnel Suitability and Security Program. The Office for Operations, Security, and Preparedness is responsible for these policies and procedures.
SECURITY INCIDENT INVESTIGATION:
a. The term security incident means an event that has, or could have, resulted in unauthorized access to, loss or damage to VA assets, or sensitive information, or an action that breaches VA security procedures. The contractor/subcontractor shall immediately notify the COR and simultaneously, the designated ISO and Privacy Officer for the contract of any known or suspected security/privacy incidents, or any unauthorized disclosure of sensitive information, including that contained in system(s) to which the contractor/subcontractor has access.
b. To the extent known by the contractor/subcontractor, the contractor/subcontractor s notice to VA shall identify the information involved, the circumstances surrounding the incident (including to whom, how, when, and where the VA information or assets were placed at risk or compromised), and any other information that the contractor/subcontractor considers relevant.
c. With respect to unsecured protected health information, the business associate is deemed to have discovered a data breach when the business associate knew or should have known of a breach of such information. Upon discovery, the business associate must notify the covered entity of the breach. Notifications need to be made in accordance with the executed business associate agreement.
d. In instances of theft or break-in or other criminal activity, the contractor/subcontractor must concurrently report the incident to the appropriate law enforcement entity (or entities) of jurisdiction, including the VA OIG and Security and Law Enforcement. The contractor, its employees, and its subcontractors and their employees shall cooperate with VA and any law enforcement authority responsible for the investigation and prosecution of any possible criminal law violation(s) associated with any incident. The contractor/subcontractor shall cooperate with VA in any civil litigation to recover VA information, obtain monetary or other compensation from a third party for damages arising from any incident, or obtain injunctive relief against any third party arising from, or related to, the incident.
LIQUIDATED DAMAGES FOR DATA BREACH:
a. Consistent with the requirements of 38 U.S.C. §5725, a contract may require access to sensitive personal information. If so, the contractor is liable to VA for liquidated damages in the event of a data breach or privacy incident involving any SPI the contractor/subcontractor processes or maintains under this contract. However, it is the policy of VA to forgo collection of liquidated damages in the event the contractor provides payment of actual damages in an amount determined to be adequate by the agency.
b. The contractor/subcontractor shall provide notice to VA of a security incident as set forth in the Security Incident Investigation section above. Upon such notification, VA must secure from a non-Department entity or the VA Office of Inspector General an independent risk analysis of the data breach to determine the level of risk associated with the data breach for the potential misuse of any sensitive personal information involved in the data breach. The term 'data breach' means the loss, theft, or other unauthorized access, or any access other than that incidental to the scope of employment, to data containing sensitive personal information, in electronic or printed form, that results in the potential compromise of the confidentiality or integrity of the data. Contractor shall fully cooperate with the entity performing the risk analysis. Failure to cooperate may be deemed a material breach and grounds for contract termination.
SECURITY CONTROLS COMPLIANCE TESTING:
On a periodic basis, VA, including the Office of Inspector General, reserves the right to evaluate any or all of the security controls and privacy practices implemented by the contractor under the clauses contained within the contract. With 10 working-days notice, at the request of the government, the contractor must fully cooperate and assist in a government-sponsored security controls assessment at each location wherein VA information is processed or stored, or information systems are developed, operated, maintained, or used on behalf of VA, including those initiated by the Office of Inspector General. The government may conduct a security control assessment on shorter notice (to include unannounced assessments) as determined by VA in the event of a security incident or at any other time.
TRAINING: the training identified in this section does not apply to this contract until such time as when personnel would be working in the site(s), locations, of the VA on a regular basis. Regular basis would include daily work, physically in the hospital, for the duration of the period of performance identified.
a. All contractor employees and subcontractor employees requiring access to VA information and VA information systems shall complete VA Privacy and Information Security Awareness and Rules of Behavior Training before being granted access to VA information and its systems.
(1) Sign and acknowledge (either manually or electronically) understanding of and responsibilities for compliance with the Rules of Behavior before being granted access to VA information and its systems.
b. The contractor shall provide to the contracting officer and/or the COR a copy of the training certificates and certification of signing the Rules of Behavior for each applicable employee within 1 week of the initiation of the contract and annually thereafter, as required.
c. Failure to complete the mandatory annual training and sign the Rules of Behavior annually, within the timeframe required, is grounds for suspension or termination of all physical or electronic access privileges and removal from work on the contract until such time as the training and documents are complete.
The Certification and Accreditation (C&A) requirements do not apply and a Security Accreditation Package is not required for this SON.
All Contractor, Pharmaceutical Company Representative (PCR), and Healthcare Industry Representatives (HIR) will coordinate with Contracting Officer Representative for instructions so they are in compliance with James A. Haley Veterans Hospital policies listed on the JAHMC Document Management Center share point site:
HPM NO. 90-25; HEALTHCARE VENDOR ACCESS AND COMPETENCY
HPM NO. 132-04; SECURITY MANAGEMENT PROGRAM
HPM NO. 132 05; HOSPITAL IDENTIFICATION PROGRAM
HPM NO. 11-91; PHARMACEUTICAL COMPANY REPRESENTATIVES
HIR are required to report to MSDU (Room GC-003), immediately after entering the facility. HIR will be required to sign into the monitoring system and print a badge for proper identification. . The Healthcare Industry Representatives for Nutrition and Food Services, Office of Information and Technology, and Social Work Services are in included in this policy; vendors (HIR) for Pharmacy Services are to follow (HPM 11-91) policy. HIR must be sponsored by a physician, a Service Chief, or their designee, for a specified date and a specified case. HIR are not permitted in patient care areas or clinics unless a prior appointment has been made.

a. Sign-In: PCRs may visit VA Medical care facilities no earlier than 8:00 a.m. and stay no later than 3:30 p.m., Monday through Friday, unless they receive prior approval from both the Chief of the Service that they will be visiting and the Chief of Pharmacy. Representatives visiting the JAHVH must sign in at the Pharmacy Administrative Office (Located in Trailer 78) and wear a visitor s badge as well as their company s personal name badge while in the hospital.
Vendors: Reference Hospital Memorandum Policy Number 90-25 Healthcare Vendor Access and Competency.
Contractors and/or project managers: Will be issued a PIV/ID badge in accordance with the facility PIV Policy. Contactors will contact their assigned VA Contracting Officer Representative (COR) for coordination.
Contract Personnel/Sub-Contractors: Contractors are responsible for the daily accountability and identification of all personnel assigned to their respective contract including sub-contractors. Contractors will identify personnel using the following procedures as appropriate.
Construction Project contract personnel will report to the contractor for issuance of a temporary self-adhesive identification badge. This badge will be issued on a daily basis and must include the following information: Company name, project number, date and name of individual. Contractor will maintain a daily log of all personnel.
Contract personnel not involved in an actual construction project will report to police dispatch for issuance of a numbered badge. A driver s license or photo ID will be required each day upon entering the facility, in exchange for the badge, and will be given back once the badge is returned to police dispatch. The contractor will provide Police Service with a list of names for all sub-contract personnel requiring access to the facility. It is the responsibility of the contractor to update the list as necessary.
NPR OPC; CBOCs and Off-site Lease facilities with VA Police staffing: As above with check-in with VA Police.
Off-site Lease facilities w/o VA Police staffing: Coordinate with COR, Administrative Officer, or Service Point of Contact.
Attachments/Links
Contact Information
Contracting Office Address
  • 8875 HIDDEN RIVER PARKWAY
  • TAMPA , FL 33637
  • USA
Primary Point of Contact
Secondary Point of Contact


History
  • Apr 27, 2026 03:08 pm EDTAward Notice (Original)
Daily notification on new contract opportunities

With GovernmentContracts, you can:

  • Find more opportunities and win more business
  • Receive daily alerts for all new bid opportunities
  • Get contract opportunities matched to your business
ONE WEEK FREE TRIAL
* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.