| Location: | Texas |
|---|---|
| Posted: | Jul 1, 2025 |
| Due: | Jul 14, 2025 |
| Agency: | DEPT OF DEFENSE |
| Type of Government: | Federal |
| Category: |
|
| Solicitation No: | 1301263741 |
| Publication URL: | To access bid details, please log in. |
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
July 1, 2025 UPDATE - Please see questions and answers attached to this solicitation.
This solicitation is being issued as a small business set-aside. The associated NAICS code is 334516. Offerors must be registered in Systems for Award Management (SAM) at www.sam.gov per FAR 52.212.1. All offers must also have a Unique Entity Identification Number at (SAM) at www.sam.gov and be able to submit invoices through Wide Area Work Flow (WAWF). Lack of registration in SAM will qualify contractor as ineligible for award. All responsible sources may submit a quotation in response to this solicitation which shall be considered. The solicitation is being issued as a Request for Quote (RFQ) for a firm fixed type contract based on the Lowest Price Technically Acceptable.
The Naval Medical Research Command (NMRC) intends to award a contract resulting from this solicitation to the responsible offeror. The requirement is for the purchase of a floor standing high-speed centrifuge that will replace a previous Beckman-Coulter high-speed centrifuge. The Naval Medical Research Unit - San Antonio (NAMRU-SA) synthesizes novel therapeutics utilizing centrifugation. To rapidly complete these syntheses a high centrifugation speed of at least 100,000xg is required. The centrifuge must support In Vitro Diagnostics (IVD) compatibility as well as 15mL and 50mL conical and 30mL round bottom centrifuge tubes. Samples spun down in the centrifuge will need a temperature maintained for the duration of the centrifugation between -20o and +40oC. Electrical requirements must be within 200-240 VAC and 24-30A. No instrument maintenance plan is advised at this time as the previous unit lasted 8 years (2 years prior to its 10-year life expectancy) without major repair or maintenance. A new Beckman-Coulter Avanti JXN-30 would meet these requirements. Specific items for pricing are as follows:
1. AVANTI JXN 30 200V 208V 240V - QTY: 1/EA.
2. SHIPPING - QTY: 1/EA.
*All questions should be directed to: Shamai Carter, Contracting Officer at shamai.m.carter.civ@health.mil or (301) 319-9955*
| Jun 27, 2025 | [Solicitation (Original)] Floor Standing High-Speed Centrifuge |

With GovernmentContracts, you can:
...Classification Original Set Aside: Total Small Business Set-Aside (FAR 19.5) Product Service Code... ...
DEPT OF DEFENSE
Bid Due: 6/12/2026
...Systems Active Contract Opportunity Notice ID 36C25726Q0624 Related Notice Department/Ind. Agency... Code: 221310 ...
VETERANS AFFAIRS, DEPARTMENT OF
Bid Due: 6/10/2026
...) Program for water system improvements. Scope of Work: Services to be provided ...
Rio Grande City
Bid Due: 6/23/2026
...27, 2026 Initiative: None Classification Original Set Aside: Product Service Code: 6632 - ...
VETERANS AFFAIRS, DEPARTMENT OF
Bid Due: 6/12/2026