S222--Grease Trap Cleaning and Maintenance Grand Junction VA Medical Center
| Location: |
Virginia |
| Posted: |
Mar 9, 2026 |
| Due: |
Mar 13, 2026 |
| Agency: |
VETERANS AFFAIRS, DEPARTMENT OF |
| Type of Government: |
Federal |
| Category: |
- S - Utilities and Training Services
|
| Solicitation No: |
36C25926Q0252 |
| Publication URL: |
To access bid details, please log in. |
S222--Grease Trap Cleaning and Maintenance Grand Junction VA Medical Center
Active
Contract Opportunity
Department/Ind. Agency
VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier
VETERANS AFFAIRS, DEPARTMENT OF
Office
NETWORK CONTRACT OFFICE 19 (36C259)
Looking for contract opportunity help?
General Information View Changes
-
Contract Opportunity Type: Combined Synopsis/Solicitation (Updated)
-
Updated Published Date: Mar 09, 2026 02:20 pm MDT
-
Original Published Date: Feb 25, 2026 03:57 pm MST
-
Updated Date Offers Due: Mar 13, 2026 12:00 pm MDT
-
Original Date Offers Due: Mar 13, 2026 12:00 pm MDT
-
Inactive Policy: Manual
-
Updated Inactive Date: Mar 28, 2026
-
Original Inactive Date:
Mar 28, 2026
-
Initiative:
Classification View Changes
Description View Changes
Amendment 001 to Solicitation #36C25926Q0234 (Grease Trap Cleaning and Maintenance Services)
This amendment s purpose is to list and answer the questions submitted by the questions deadline as specified in the solicitation.
Questions and Answers:
Are we allowed to drag hoses through the building to pump out the grease traps, or are we required to use a system such as a 55-gallon drum shop vac setup, and then pump from the drum into our truck outside?
Please utilize a self-contained system within the building (a shop vac setup should be sufficient). Hoses from a truck parked outside the building, run through the building, will not be allowed.
What are theĆ detailed specifications for the decal service stickers that we must provide?
Service stickers must include the following information:
Company name and contact information
Technician name or ID
Date of last service/cleaning
Next recommended service date or required service interval
Do we have to wear hair nets in the kitchen?
Yes.
What kind of cleaner and cleaning method is required for us to scrub down our work area?
Since the work areas are in the 1st and 3rd floor kitchens, cleanup after service must be to a standard that is suitable for an area where food is prepared. Debris and dirt should be removed, use a non-abrasive cleaner and an EPA-registered hospital disinfectant on the work area. Specific product recommendations will be provided after award.
May we use the service elevator to perform this work or do we have to use the stairwell?
The Contractor will be permitted to use the stairwell or the service elevator. However, the Contractor will not be the only entity using the service elevator during the working hours.
Will we be required to hydro-jet any inlet or outlet pipes as part of this service?
Please hydro jet any inlet or outlet pipes as needed during the service, if there is a visible blockage or upon VA staff request.
Will we be required to perform enzyme treatments in the grease traps?
Yes. During each service, please utilize an enzyme treatment that is manufacturer-approved for use with the grease trap(s). See attached O&M Manuals for manufacturer contact information.
Attachments/Links
Contact Information
Contracting Office Address
-
6162 S WILLOW DR SUITE 300
-
Greenwood Village , CO 80111
-
USA
Secondary Point of Contact
History
Daily notification on new contract opportunities
With GovernmentContracts, you can:
- Find more opportunities and win more business
- Receive daily alerts for all new bid opportunities
- Get contract opportunities matched to your business
ONE WEEK FREE TRIAL
* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.