Fire Suppression Sprinklers at Coatesville VAMC

Location: Pennsylvania
Posted: Jun 30, 2026
Due: Jul 8, 2026
Agency: VETERANS AFFAIRS, DEPARTMENT OF
Type of Government: Federal
Category:
  • H - Quality Control, Testing, and Inspection Services
Solicitation No: 36C24426Q0415
Publication URL: To access bid details, please log in.
Follow
Fire Suppression Sprinklers at Coatesville VAMC
Active
Contract Opportunity
Notice ID
36C24426Q0415
Related Notice
Department/Ind. Agency
VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier
VETERANS AFFAIRS, DEPARTMENT OF
Office
244-NETWORK CONTRACT OFFICE 4 (36C244)
Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information
  • Contract Opportunity Type: Combined Synopsis/Solicitation (Original)
  • Original Published Date: Jun 30, 2026 12:50 pm EDT
  • Original Date Offers Due: Jul 08, 2026 11:00 am EDT
  • Inactive Policy: 15 days after date offers due
  • Original Inactive Date: Jul 23, 2026
  • Initiative:
    • None
Classification
  • Original Set Aside: Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
  • Product Service Code: H312 - INSPECTION- FIRE CONTROL EQUIPMENT
  • NAICS Code:
    • 811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
  • Place of Performance:
    Coatesville , PA 19320
    USA
Description

Five-Year Obstruction Inspection of Sprinkler System



Coatesville VA Medical Center



1. Scope



The contractor shall provide all labor, materials, equipment, and supervision required to perform the five-year obstruction inspection, testing, and maintenance of the facility’s sprinkler systems in accordance with NFPA (National Fire Protection Association’s) 25 and applicable codes. Work includes internal pipe assessments, valve inspections, FDC hydrostatic testing, hydrant flow testing, and replacement of sprinkler gauges.



2. Applicable Standards



All work shall comply with NFPA 25 (current edition) and VA policies and directives.



3. Requirements



The contractor shall perform all NFPA 25‑required internal inspections, obstruction investigations, fire department connection (FDC) hydrostatic tests, hydrant flow tests, and sprinkler gauge replacements. The contractor shall coordinate all required system shutdowns with the designated VA Point of Contact (POC), adhere strictly to all VA safety protocols, and ensure that all work is performed by properly qualified technicians. All work shall be completed within 30 calendar days of award and shall be conducted Monday through Friday during administrative hours (8:00 a.m. to 4:30 p.m.). No work shall be performed on weekends or Federal holidays. All contractor personnel shall wear visible company identification badges displaying both the company name and the employee’s name.



3.1. Building 1 Annual Inspection



The contractor shall perform an annual fire pump inspection in the attic of Building 1 to ensure the stability and integrity of primary VAMC campus location. Flow testing at 100% rated capacity. Measurements of the suction pressure, discharge pressure and flow rate. Manufacturer’s pump curve compared to the current pump performance curve. Documentation of all readings, to include voltage and amperage. Compare to specifications and any deviations requiring corrective action. All equipment evaluations, diagnosis of equipment deficiencies and malfunctions, inspection and acceptance, as well as documentation of all tasks and services provided shall be furnished by the Contractor to the Coatesville VAMC PoC.





3.2. Sprinkler System Maintenance & Internal Inspection



A 5-year internal inspection cycle of sprinkler systems will be performed at the Coatesville VAMC Campus. The sprinkler systems gauges will be replaced at the following Buildings: 1, 2, 3, 4, 6, 7, 8, 9, 38, 39, 57, 59, 69, 138 and 139. Building Maintenance will be spread over a 5 year period in which the contractor will have 30 calendar days to complete these services (maintenance, inspection and repairs) of each tranche of buildings. The schedules is as followed:





Base Year- Services for Buildings 1, 2, 3



Option Year 1- Services for Buildings 4, 6, 7



Option Year 2- Services for Buildings 8, 9, 38



Option Year 3- Services for Buildings 39, 57, 59



Option Year 4- Services for Buildings 69, 138, 139





Building maintenance will be grouped together with their respective contract years and will billed as one “job”. Each job shall include the following requirements: service, testing and inspection, maintenance, replacement of all necessary materials, and supplies. The contractor shall provide full maintenance services, including all adjustments, calibration, and tuning. As part of this service, the Contractor shall include diagnosis and evaluation of all equipment, any deficiencies, malfunctions, inspection and acceptance; as well as documentation of all tasks and services provided.





3.3. Miscellaneous Maintenance Repairs



Each repair shall include all service, testing and inspection. The Contractor shall provide all parts, materials, supplies, labor, supervision, tools, shipping, travel, and equipment necessary to resolve the deficiency or malfunction.



4. Deliverables



Contractor shall submit inspection reports to the VA POC within five business days after work completion. Reports must document inspection findings, deficiencies, photographic evidence where required, and recommended corrective actions.



5. Government Responsibilities



The VA POC will provide access to equipment, coordinate fire watch procedures if needed, and review contractor-submitted documentation.



6. References



The VA Fire Protection Design Manual (Attachment A) and the Fire Safety Guidebook (Attachment B) are the guidelines supporting this requirement.




Attachments/Links
Contact Information
Contracting Office Address
  • 1010 DELAFIELD ROAD
  • PITTSBURGH , PA 15215
  • USA
Primary Point of Contact
Secondary Point of Contact
History
  • Jun 30, 2026 12:50 pm EDTCombined Synopsis/Solicitation (Original)

Related Document

Jul 1, 2026[Combined Synopsis/Solicitation (Updated)] Fire Suppression Sprinklers at Coatesville VAMC
Jul 3, 2026[Combined Synopsis/Solicitation (Updated)] Fire Suppression Sprinklers at Coatesville VAMC
Jul 6, 2026[Combined Synopsis/Solicitation (Updated)] Fire Suppression Sprinklers at Coatesville VAMC
Daily notification on new contract opportunities

With GovernmentContracts, you can:

  • Find more opportunities and win more business
  • Receive daily alerts for all new bid opportunities
  • Get contract opportunities matched to your business
ONE WEEK FREE TRIAL

See also

...Command TROOP SUPPORT MEDICAL Office DLA TROOP SUPPORT Looking for contract opportunity help? ...

DEPT OF DEFENSE

Bid Due: 7/24/2026

...needs. C. Documentation. The awarded contractor shall provide documentation of each resident visit... ...

State Government of Pennsylvania

Bid Due: 7/24/2026

..., and medical maintenance in a barrier-free environment. At the HGAC, education is ...

State Government of Pennsylvania

Bid Due: 7/24/2026

* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.