J045--CON-NRM-687-21-106 Replace Mechanical and Plumbing Systems in Multiple Buildings
| Location: |
Federal |
| Posted: |
Aug 1, 2025 |
| Due: |
Aug 11, 2025 |
| Agency: |
VETERANS AFFAIRS, DEPARTMENT OF |
| Type of Government: |
Federal |
| Category: |
- J - Maintenance, Repair, and Rebuilding of Equipment
|
| Solicitation No: |
36C26025R0065 |
| Publication URL: |
To access bid details, please log in. |
J045--CON-NRM-687-21-106 Replace Mechanical and Plumbing Systems in Multiple Buildings
Active
Contract Opportunity
Department/Ind. Agency
VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier
VETERANS AFFAIRS, DEPARTMENT OF
Office
260-NETWORK CONTRACT OFFICE 20 (36C260)
Looking for contract opportunity help?
General Information View Changes
-
Contract Opportunity Type: Solicitation (Updated)
-
Updated Published Date: Aug 01, 2025 03:06 pm PDT
-
Original Published Date: Jun 27, 2025 09:33 am PDT
-
Updated Date Offers Due: Aug 11, 2025 08:00 am PDT
-
Original Date Offers Due: Jul 28, 2025 08:00 am PDT
-
Inactive Policy: Manual
-
Updated Inactive Date: Sep 10, 2025
-
Original Inactive Date:
Sep 26, 2025
-
Initiative:
Classification
-
Original Set Aside:
-
-
Product Service Code: J045 - MAINT/REPAIR/REBUILD OF EQUIPMENT- PLUMBING, HEATING, AND WASTE DISPOSAL EQUIPMENT
-
NAICS Code:
-
238220 - Plumbing, Heating, and Air-Conditioning Contractors
-
Place of Performance:
Description View Changes
Sheet note #9 on drawing 000-ES-002 sheet note #13 on drawing #000-ES-003 both refer to providing redundant conduits per PSRDM Section 8.3.3. Both sheet notes point to new power service feeders, however PSRDM Section 8.3.3 is in reference to Telecom service requirements. Please clarify the intent of the sheet notes.
ANSWER: Note #9 only pertains to the feed between MVSS-76-12KV and T-63/65-12KV-208V, but that s also not a PSRDM requirement. So, that and Note #9 attached to the feed to 65DP11 can be ignored. The intent is to provide a single spare 4 conduit to the utility transformer T-63/65-12KV-208V.
Please identify the outside heat pump units for the following inside units:
ANSWER:
0T7-IU-2 (0T7-OU-2)
0T7-IU-5 (0T7-OU-3)
0T7-IU-6 (0T7-OU-3)
Please identify wiring requirements between the outside and inside units.
ANSWER: Connections should be based on manufacturer s recommendations and specifications.
On drawing0T1-EP-101sheet note #4 indicates that panel T1P11 is to be 200 amps, confirmed on sheet note #8 on page 000-EJ-003. However the new feeder to the new panel is shown as (2) 2 c 4#3/0, 1#6g. Please clarify feeder size.
ANSWER: The quantity of parallel feeds indicated for T1P11 on 000-EJ-003 is a typo. The feeder sizes should be a single feed with (1) 2 C, 4#3/0, 1#6 GND.
On drawing 000-EJ-003 the feeder to panel 63P11 is indicated as existing to remain. Sheet note #6 on page 063-ep-101 indicates that the feeder is to be replaced with a 2 conduit with 4#1, 1#8g. Please clarify scope.
ANSWER: We were originally going to replace the feeders for 63P11 and reroute to the new transformer outside. That was changed to providing the connection to 65DP11 and leaving the existing feeders for 63P11. The one-line is correct.
Can the Asbestos Report for Building 66 be provided for bid purposes? Attached to the email. Attached to the email.
ANSWER: See Attachment 12.
Is the 10 days after NTP accurate?
ANSWER: This is accurate but can be negotiated if more time is needed. This is accurate but can be negotiated if more time is needed.
Our electrical subcontractor is asking if it would be possible to get in to look at the existing switchgear that we re replacing breakers in, or if the VA can send us photos of the gear (Bldg. 63 63P11; Bldg. 74 74D12; Bldg. 74 74P22; Bldg. 78 78DS1; Bldg. 81 81P11; Bldg. 82 82P22; Bldg. 140 MSB; Bldg. 143 MDB-1). The costs vary widely depending on the manufacturer and we d like to match the manufacturer. Link sent to contracting officer with pictures of these units.
ANSWER: See Attachment 22.
Please provide any available civil and utility as-built/record drawings showing subsurface conditions in the areas expected to be impacted by this project. Â Â
ANSWER: See Attachment 23.
Attachments/Links
Contact Information
Contracting Office Address
-
1601 E Fourth Plain Blvd Bldg 17 Suite B428
-
VANCOUVER , WA 98661
-
USA
Secondary Point of Contact
History
Daily notification on new contract opportunities
With GovernmentContracts, you can:
- Find more opportunities and win more business
- Receive daily alerts for all new bid opportunities
- Get contract opportunities matched to your business
ONE WEEK FREE TRIAL
See also
Follow Y--VOYA 335009 N191 REHAB RAINY AND ASH Active Contract Opportunity Notice ID
INTERIOR, DEPARTMENT OF THE
Bid Due: 6/09/2026
Follow 20--CYLINDER,DUPLEX Active Contract Opportunity Notice ID N0010426QYA76 Related Notice Department/Ind. Agency DEPT
DEPT OF DEFENSE
Bid Due: 7/31/2026
Follow F--Snake River Area Office Weed Control Active Contract Opportunity Notice ID 140R1726Q0025
INTERIOR, DEPARTMENT OF THE
Bid Due: 6/12/2026
Follow Z1DA--646-21-101 UD SPS AHU & RO Upgrade (VA-26-00036217) Active Contract Opportunity Notice
VETERANS AFFAIRS, DEPARTMENT OF
Bid Due: 6/11/2026
* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.