Request for Quote
Date Issued
Procurement Officer
Phone
E-Mail Address
RFQ 26006-JD
December 3, 2025
James de Luca, CPPO
843-953-6861
jdeluca@citadel.edu
DESCRIPTION: The Citadel is seeking written quotes for 5-Year Internal Valve and Pipe
Inspection – Fire Protection Systems (NFPA 25 Compliance) services.
SUBMIT WRITTEN QUOTE by: Wednesday, December 17, 2026 at 11:00 AM via
email attachment to the Procurement Officer listed above.
QUESTIONS: All questions regarding this quote request shall be submitted in writing to the
email address of the Procurement Officer listed above at least two (2) business days before
quotes are due.
Fire Protection Systems Valve and Pipe Inspection Requirements:
Scope of Work:
We request a quote to conduct the five-year internal piping condition assessment and valve inspection on
all fire protection risers and standpipes at The Citadel campus in Charleston, South Carolina, and The
Citadel Beach House in Isle of Palms as listed in Attachment A, following the requirements of NFPA 25
(2020), Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems.
Systems Summary (Attachment A):
• Total Risers: 30
o One riser is off campus, in Isle of Palms, SC.
• 28 Wet Systems
• 2 Dry/Pre-Action Systems
NFPA 25 Five-Year Inspection Requirements:
A 5-year riser inspection per NFPA 25 (2020) includes an internal pipe inspection, obstruction
investigation, and a flow test.
The scope involves opening a flushing connection and removing a sprinkler to check for foreign material;
if any is found, a more thorough inspection and cleaning are required.
Other components, such as valves, gauges, and the fire department connection (FDC), are also inspected,
and a whole system flow test is performed for automatic standpipe systems.
Internal Pipe and Obstruction Inspection
• Initial Assessment:
o Open a flushing connection at the end of a main line and remove a sprinkler from the end
of a branch line to visually inspect the interior of the pipes for corrosion, scale, or debris.
• Obstruction Investigation:
o If any foreign material, such as corrosion, sludge, or other debris, is detected, a more
thorough internal pipe inspection and obstruction investigation will be carried out.
• Potential Follow-Up Actions:
o May involve flushing the system or, in serious cases, replacing damaged pipe sections.
• Critical Points:
o The inspection assesses the internal condition of the system valve, riser, cross main, and
branch line.
Flow and Pressure Testing:
• Standpipe Flow Test:
o Conduct a flow test on all automatic standpipe systems to verify that the required flow
and pressure are available at the most remote hose outlet(s).
• Pressure Gauge Check:
o Inspect, test, or calibrate all pressure gauges on the risers to ensure they are accurate and
function correctly.
Other Required Inspections:
• Valves:
o Conduct an internal inspection of alarm valves and system riser check valves, including
cleaning and resetting as needed.
• Fire Department Connection (FDC):
o Inspect the FDC, perform a backflush, and visually inspect the interior connection to
ensure it can deliver adequate water pressure and volume.
• Visual Inspection:
o Perform a visual inspection of sprinklers for corrosion, physical damage, paint, loading,
or incorrect orientation.
• Controls and Accessories:
o Inspect all control valves, alarm devices, and other system components as required by
NFPA 25 inspection tables.
Deliverables:
• Comprehensive inspection report, including findings, photos (if applicable), and any
recommended corrective actions.
• Updated inspection tags and documentation for each riser and device inspected.
• Certification of compliance with NFPA 25 standards.
The Citadel reserves the right to make award(s) either by item or lot to one or multiple responsible
and responsive offerors.
Attachment A
Building
Library
McAllister Field House
F&E Complex
Mark Clark Hall
Jenkins Hall
Letellier Hall
VTR
Swain Boating Center
Laundry/Cadet Store
Coward Hall
Murray Barracks
Padgett Thomas Barracks
Law Barracks
Watts Barracks
Stevens Barracks
Duckett Hall
Bond Hall
Capers Hall
Bastin Hall
Thompson Hall
Infirmary
Altman Center
Hagood Stadium
The Citadel Beach House
Sprinkler
Wet
Dry
1
1
1
3
1
1
1
1
1
2
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
Vendors who are claiming preferences must make it clear which preferences are being
requested and include a signed copy of this page with their quote.
US End Product____
SC End Product____
Resident Vendor____
Resident Contractor____ Resident Sub-Contractor____
PREFERENCES - A NOTICE TO VENDORS (SEP. 2009): On June 16, 2009, the South Carolina General Assembly rewrote the law
governing preferences available to in-state vendors, vendors using in-state subcontractors, and vendors selling in-state or US end products.
This law appears in Section 11-35-1524 of the South Carolina Code of Laws. A summary of the new preferences is available at
www.procurement.sc.gov/preferences. ALL THE PREFERENCES MUST BE CLAIMED AND ARE APPLIED BY LINE ITEM,
REGARDLESS OF WHETHER AWARD IS MADE BY ITEM OR LOT. VENDORS ARE CAUTIONED TO CAREFULLY
REVIEW THE STATUTE BEFORE CLAIMING ANY PREFERENCES. THE REQUIREMENTS TO QUALIFY HAVE
CHANGED. IF YOU REQUEST A PREFERENCE, YOU ARE CERTIFYING THAT YOUR OFFER QUALIFIES FOR THE
PREFERENCE YOU'VE CLAIMED. IMPROPERLY REQUESTING A PREFERENCE CAN HAVE SERIOUS
CONSEQUENCES. [11-35-1524(E)(4)&(6)]
PREFERENCES - ADDRESS AND PHONE OF IN-STATE OFFICE: Please provide the address and phone number for your in-state office
in the space provided below. An in-state office is necessary to claim either the Resident Vendor Preference (11-35-1524(C) (1) (i) & (ii)) or
the Resident Contractor Preference (11-35-1524(C) (1) (iii)). Accordingly, you must provide this information to qualify for the preference.
An in-state office is not required, but can be beneficial, if you are claiming the Resident Subcontractor Preference (11-35-1524(D)).
____ In-State Office Address same as Home Office Address
____ In-State Office Address same as Notice Address (check only one)
HOME OFFICE ADDRESS (Address for Offeror's home office / NOTICE ADDRESS (Address to which all procurement and contract
principal place of business)
related notices should be sent.) (See "Notice" clause)
_________________________________________________
Area Code - Number - Extension
Facsimile
_________________________________________________
E-mail Address
You must submit a signed copy of this form with your quote if claiming any vendor preferences.
NAME OF OFFEROR (Full legal name of business submitting the offer)
AUTHORIZED SIGNATURE
Any award issued will be issued to, and the contract will be formed with, the
entity identified as the Offeror. The entity named as the offeror must be a
single and distinct legal entity. Do not use the name of a branch office or a
division of a larger entity if the branch or division is not a separate legal
entity, i.e., a separate corporation, partnership, sole proprietorship, etc.
DATE SIGNED
(Person must be authorized to submit binding offer to contract on behalf of Offeror.)
PRINTED NAME & TITLE (Name and Business title of person signing above)
STATE VENDOR NO.
TAXPAYER IDENTIFICATION NO.
(Register to Obtain S.C. Vendor No. at www.procurment.sc.gov)
STATE OF INCORPORATION
(If you are a corporation, identify the state of incorporation)
Rev 04/2021
This is the opportunity summary page. It provides an overview of this opportunity and a preview of the attached documentation.