TOWNSHIP OF DENVILLE
MORRIS COUNTY, NEW JERSEY
RENOVATION OF A HISTORIC STRUCTURE
INTO A COMMUNITY CIVIC CENTER - REBID
Addendum No. 1
October 29, 2026
To All Concerned:
The original contract documents for the above referenced contract are amended as noted in this Addendum.
This Addendum shall become part of the Contract Documents and is to be attached thereto. Bidders shall
acknowledge receipt of this Addendum on page B-4 of the Bid Documents.
BIDDERS are responsible for distributing Addendum No. 1 to all the parties involved in the preparation of
their bid. This Addendum includes the following:
I - Contractor Questions:
Q1: Please provide all available asbestos and lead surveys, sampling results, and prior
removal/clearance records, or confirm that none exist. A-050 note 18 identifies vinyl asbestos tile,
including mastic/adhesive, while Section 02 82 13.21 addresses non-abatement resilient-flooring removal.
Please identify other known or presumed asbestos-containing materials, especially exterior materials
affected by roofing, window, siding, trim, and porch work, with locations and quantities.
Is the contractor responsible for a pre-disturbance material survey and bulk sampling, in addition to the
expressly required air monitoring? Please define the base-bid treatment and payment mechanism if
testing identifies asbestos beyond the specified flooring or conditions unsuitable for the specified non-
abatement method. We have not located a separate exterior-asbestos removal note or survey in the
issued package.
A1: There are no available environmental reports. Vinyl asbestos tile and lead based paint are the
only assumed hazardous materials at this time. Any additional materials suspected of being
hazardous shall be brought to the Owner and Architect's attention. Any unforeseen hazardous
materials should be brought to the attention of the Owner and Architect. If beyond the scope of
the base bid documents, changes will be administered per Article XXXI - "Changes, Changed
Conditions, Change Orders".
Q2: Section 02 83 19 states lead was not tested and requires appropriate paint/dust testing and
contractor investigation. Please confirm the required testing, work-plan, monitoring/clearance, and
disposal deliverables for interior and exterior paint-disturbing work. Much of the interior appeared stripped
to framing, but the walkthrough photos show remaining floor pieces/residue, radiators/piping, some
ceiling/wall finishes, and restroom fixtures/partitions. A-050 still includes wall, ceiling, floor, MEP, and VAT
demolition. Please identify work already completed and accepted, the remaining demolition/VAT scope,
and associated disposal or clearance records. Please confirm any deletions or revisions by addendum.
A2: See Drawing A-050 for the required extent of demolition and Specification Section 02 83 19 for
the requirements of Lead Based Paint management.
Q3: C104 states "THREE (2)" drywells. C107 calculates three units with 6 ft inside diameter, 7 ft outside
diameter, and 8 ft depth; C108 includes a 6 ft vertical dimension, while inlet 666 +/- and tank-bottom 658
+/- elevations indicate 8 ft. Please issue coordinated count, tank dimensions, rim/inlet/bottom elevations,
stone-envelope dimensions, and storage calculations. Please provide the infiltration/soil and groundwater
information supporting the design and identify the required verification and treatment of unsuitable soil,
rock, or groundwater at the proposed stone-bottom elevation 656 +/-.
A3: Engineering Drawing sheets C-104, C-107, & C-108 have been revised to specify three (3)
drywells, 4 deep with 2' of stone under and around each drywell. All calculations and revised have
been revised. Percolation tests, borings, or groundwater data is not available for the drywell
A1-1 of A1-5
Addendum No. 1
locations. Groundwater and rock are not anticipated. The stone-bottom elevation has been revised,
see revised plans.
Q4: IB Section 0.08 requires on-site work by the prime's own organization equivalent to at least 51% by
cost of total contract work. Please confirm its applicability to this overall contract and specify the
calculation, denominator, eligible cost categories, and required evidence. How are labor, directly
purchased materials, equipment, subcontractor-installed materials, general conditions, overhead/profit,
and the $35,000 allowance treated? Please identify any pre-bid adjustment or clarification; the stated
possible reduction during performance does not establish a bid-stage exception.
A4: The prime Contractor (the bidder) shall perform on the site and with its own organization,
work equivalent to at least 51% (by cost) of the total amount of work to be performed under this
Contract.
Q5: Please confirm the reinforcement on A-100 and A-400 remains in base scope, including joist
sistering, girder LVLs, and ceiling-joist lap reinforcement, regardless of visible sagging. Please identify the
baseline quantity/locations of basement-column replacements and crack repairs, the applicable header-
upgrade scope under S-101, and the procedure/payment treatment for concealed deterioration or
additional repairs identified during the required existing-framing verification.
A5: All structural reinforcement is to be included in the base scope of this project. The Contractor
shall be responsible for quantifying all items. Any concealed and unforeseen deterioration shall
be brought to the attention of the Owner and Architect. If required, changes to the scope of work
will be administered per Article XXXI - "Changes, Changed Conditions, Change Orders".
Q6: A-300/A-301 require 500 SF of in-kind rotted-siding replacement in the base bid, with locations
coordinated by the architect. Please confirm 500 SF is the project total, identify known locations, and
clarify the treatment of additional siding or concealed substrate repairs. Please confirm which, if any,
uncertain work above is intended to be paid from the $35,000 allowance and the authorization process,
rather than leaving bidders to assume the allowance covers it.
A6: Per A-300/A-301, the base bid should include up to 500sf of wood siding replacement with
locations to be coordinated with the Architect. If more than 500sf of siding replacement, or
concealed and unforeseen substrate replacement, is required, this change to the scope of work
would be administered per Article XXXI - "Changes, Changed Conditions, Change Orders".
Q7: Please reconcile M-500 recommending 30 A breakers for HP-2/HP-3 with E-600 assigning 35 A/2P
breakers. E-100 shows the electric water heater on P-13,15, while E-600 marks circuits 13/15 SPARE
with zero load. P-600 schedules EWH1 as 30 gallons, 4,500 W, 208 V/1Ph, while P-500 detail 3 labels
EWH2 and 240 V/1Ph. Please issue coordinated equipment identification, voltage, load, circuit, and
breaker requirements. Also identify the civil sheet and scope responsibility for the sanitary pump-station
connection referenced on P-100.
A7: See revised schedules and plumbing details regarding the sanitary pump station. Revised
Drawings E-100, E-600, P-001, P-100, P-500, and P-600 are attached herein.
Q8: Please share a copy of the questions and answers to RFIs from the previous bid.
A8: This project and its bid documents should be bid independently of any previous bid
documents.
Q9: Sheet C102 Demolition plan notes "Demolish / Remove existing building to foundation. Please
confirm this is an error.
A9: This note is an error. Please strike that note from sheet C102.
Q10: The project specifications call for the removal of existing vinyl asbestos tile (VAT) under non-
abatement procedures; however, no asbestos testing reports have been provided for the existing flooring
or any other materials. Please clarify whether asbestos testing for the entire building is to be included in
the base bid and confirm that the removal of the existing flooring is to be performed under non-abatement
procedures as specified. If testing confirms that the flooring contains asbestos and abatement is required,
please clarify whether the associated abatement work and costs will be addressed separately through a
A1-2 of A1-5
Addendum No. 1
change order. Additionally, please advise how the scope and associated costs are to be handled if testing
indicates that abatement is required beyond the specified non-abatement removal procedures.
A10: Vinyl asbestos tile and lead based paint are the only assumed hazardous materials at this
time. Any additional materials suspected of being hazardous shall be brought to the Owner and
Architect's attention. Removal of the existing vinyl asbestos tile shall be per specification Section
02 82 31.21. If beyond the scope of the base bid documents, changes will be administered per
Article XXXI - "Changes, Changed Conditions, Change Orders".
Q11: Section 02 83 19 - Lead-based Paint Management notes lead-based paint was not tested for, but
assumed to be associated with the building. Please clarify whether the contractor should include the cost
of lead-based paint testing only in the base bid, with any required abatement to be addressed seperately
through a change order based on the results of the testing.
A11: Per Section 02 83 19, Contractor shall include all Work involving the disturbance of lead-
based paint and related dust/debris. This includes but is not limited to testing, containment,
worker projection and removal / disposal procedures.
Q12: Please confirm that all security equipment, wiring, and associated scope (cameras, card reader, etc)
are to be provided by others under separate contract. Please confirm it is the bidders responsibility to run
conduit only.
A12: Contractor shall provide conduits with pull string per E-100.
Q13: Please confirm that all data / voice equipment, wiring, and associated scope are to be provided by
others under separate contract. Please confirm it is the bidders responsibility to run conduit only.
A13: Confirmed; refer to data/voice detail on drawing E-500 and symbol list.
Q14: Fire Alarm Initiating Devices (Smoke Detector) are shown on Sheet E-600 however, device
locations and other associated scope are not shown on the plans. Please confirm whether the fire alarm
scope is the responsibility of the bidder.
Q14: There is no fire alarm scope of work shown on the electrical drawings. Drawing E-600 only
has a smoke detector shown on the symbol list.
Q15: Please confirm whether Testing and Balancing is required.
A15:Not required for project.
Q16: Is Temporary construction fencing at the perimeter of the property required.
A16: Silt fence at the limit of disturbance is required per the plans.
Q17: Project specifications call for a field office to be shared with the owner's representative. Please
confirm whether a field office with 2 offices, 1 conference room and integrated toilet facility is the minimum
requirements as per the specs or if a standard single room field office is acceptable.
A17: Yes, a standard single room field office is acceptable.
Q18: Roof removal extent. Demolition keynote: "Remove Existing Roof System and Accessories to
Substrate." Please confirm this means shingles and underlayment down to the roof sheathing, and that
the existing rafters and ceiling joists remain. If roof sheathing is to be replaced, please give the quantity.
A18: The existing roof system, including shingles, underlayment, and accessories, shall be
removed to the existing substrate. Existing roof joists and sheathing are to remain. Contractor
shall include 130sf of 5/8" plywood sheathing in the base bid to be used as required for
replacement of deteriorated sheathing. If additional deteriorated roof sheathing is uncovered the
Contractor shall notify the Owner and Architect and replacement will be administered per Article
XXXI - "Changes, Changed Conditions, Change Orders".
Q19: Temporary shoring and bracing. Please confirm the temporary structural support bidders must carry:
a. Porch roof and pillars while the porch is removed (C102: "Install temporary support
system for pillars/roof to remain").
b. Exterior walls while the floor system and interior framing are opened up.
A1-3 of A1-5
Addendum No. 1
c. The basement girder and floor while corroded steel columns are replaced with HSS 4 x
3/16.
d. Does the Township require a temporary shoring design signed by a NJ Professional
Engineer (Structural Note 16), submitted before work starts?
A19: Engineered shoring design, including signed and sealed shop drawings, will be required per
General Structural Construction Note 16 and as required by the Township. The Contractor shall be
responsible for determining required locations for shoring.
Q20: Floor system. Keynote 12 says "Remove Existing Floor System in its Entirety," but A-100 says to
sister all existing 2x12 joists in the 18 ft span. Please confirm whether the joists remain and only the
flooring and subfloor are removed.
A20: The existing floor system, including finish flooring, substrate, and existing floor joists, shall
be removed where Selective Demolition Note 12 is indicated. Contractor shall provide new 2"x12"
floor joists at 12" O.C. max. as part of the floor/ceiling assembly indicated on A-400 to align with
the adjacent existing floor. See revised Drawing A-400 attached herein.
Q21: Structural quantities. Please confirm the number of floor joists to sister, ceiling joists to sister (all, or
only lapped ones), steel columns to replace, and linear feet of girder to reinforce with LVL.
A21: All existing ceiling joists that have a lap connection shall be reinforced with a full-length
sister joist as indicated on A-200. Existing floor joists shall be reinforced with sister joists as
indicated on A-100. New floor joists shall be provided for infill floor construction as indicated on
revised A-400, attached herein. The Contractor is responsible for material takeoff.
Q22: Roof shingle type. The drawings call for a "3-Tab Shingle Roof System." Section 07 31 13 names
architectural shingles (GAF Timberline NS, basis of design). Which is required?
A22: The asphalt roof shingles shall be architectural shingles per Section 07 31 13.
Q23: Geotechnical responsibility. S-100 says no geotechnical report was provided and the Contractor
verifies soil parameters. Other structural notes say the Owner retains the geotechnical engineer and
testing agency. Please confirm the Owner pays for geotechnical inspection and testing for the ramp, stair,
and porch footings.
A23: No Geotechnical Report is available or will be retained by the Owner. The Contractor shall
verify soil parameters and meet compaction for the required bearing capacity.
Q24: Sanitary pump station. P-500 states "Connect to fiberglass pump station by Civil Engineer." No
pump station or force main appears on the civil drawings. Is a pump station required? If so, please
provide its design and say which bid item carries it.)
A24: Pump station design has been revised. See updated Drawings P-100, P-500, P-600, and E-100
attached herein.
Q25: Underlayment. A-400 shows a 1 in. cement topping. Section 03 54 13 specifies gypsum cement
underlayment. Which product and thickness are required?
A25: The underlayment shall be 1" thick gypsum cement underlayment, see Specification Section
03 54 13.
Q26: Site light poles. C103 shows seven new poles with a fluted pole and gold finial (C108).
E-600 schedules Sternberg SL-1 and SL-2. Please confirm the quantity, which
specification governs, and which bid item carries the poles.
A26: Seven total light poles are to be provided as shown on C103. Provide SL-1 and SL-2 as
specified; refer to drawing E-010 & E-600.
Q27: EV make ready stalls. C103 shows two EV make ready stalls, but no electrical scope is
shown. Please define the work (conduit only, or wire and breaker).
A27: Refer to revised drawings E-010, E-100, E-500, and E-600.
A1-4 of A1-5
Addendum No. 1
Q28: Police traffic directors. C109 says the Township pays for police traffic directors. The
Information for Bidders says the Contractor pays. Which governs?
A28: Police are not anticipated to be required for this scope of work. If required, Police would be
paid for by the Township.
Q29: Access control. The drawings say card access is by others. The door schedule lists an "Exterior Key
Fob Entry System," and Section 08 71 00 includes electrified hardware. What does the Contractor
provide?
A29: The Contractor is responsible for providing all hardware indicated in Section 08 71 00 as well
as 1" conduit with pull string to each Card Reader location. Card Reader equipment and cabling
will be provided by others under separate contract.
II - Modifications Concerning the Contract Drawings:
DELETE engineering plan sheets C-104, C-107 & C-108 and REPLACE it with the attached plan
sheets C-104, C-107 & C-108, revised 10.27.2026
DELETE architectural plan sheets E-010, E-100, E-500, & E-600 and REPLACE it with the
attached plan sheets E-010, E-100, E-500, & E-600, revised 10.28.2026
___________________________
John Ruschke, PE
License No. 24GE0037148
A1-5 of A1-5
Addendum No. 1
| 668.2 668 . LANDSCAPING P U D N40 degrees 24' 02"E 248.51' 24" 671.49 6" PVC ROOF LEADER DRAINS 671 669 @ 1% MIN. SLOPE 670 2 7 6 1 2 TIMB ( E TY R P P IC O A S L T ) (6 7 0 ) FLUSH CURB TC EL. 669.75 T N E M E V A P E N IL Y T R E P O R P 3 7 6 ANDSCAPING @ L O P E F O E G D E D E E D L 670.17 V C N. S P M I 6" % 2 2 GAS/OIL FILL EE NN INV. EL. 668 IILL LEVEL LANDING YY AA (TYP.) WW FF 7 7 OO TT HH GG EAVES IIRR 670.33 4 ' 667.64 6 0 670.68 .5 30" (6 7 7 6 674.75 1 ) L L IS I NS T A L L T H R E E ( 3) 4 FT . D EE P DRYWELLS W /2 F T . S T O N E B E L O W T AN K S UP 6 1 .5 7 6 L L IS PRO B P U O I S LD ED IN F G F L F R O 6 E O 7 N R 5 O . 0 E V L A E T V IO AT N IONS I 6 N 6 V 7 . EL ( . SEE DETAILS ON SHEET C107 & C1086) 6 6 6 6 5 M O U 666.5 GRAVEL BF N 6 D 70 N .70 7 T 6 1 S T O R Y BUILDING 6 P F R A M E S L E ) .P NO. 501 PP EE 7 4 A (6 7 2 ) .X A M E P Y T ( P M A R UP 6" P 22 V %% C MM @ II NN.. SS LL OO 6 6 8 degrees 4 4 ' 4 1 " E S A N T T 3' I N C R EA S E O F M O T O R 671.61 2 1 :1 O L S N O 6 6 9 O AP F P S R A O N X IT IM AR AT Y E L A LO TE C R A A T L IO . N 1 7 7 U R 6 . 9 V E H IC LE S U R F A C E = 7462 SF F R S A H M E E D 8" 6 .4 6 N 4 ' P 1 4' SILL 675.26 I K W E " 1 ( 4 6 0 0' 6 7 3 2 7 6 PORCH 674.65 INV. EL. 668 6 ' R 5 7 6 4 6 degrees 6 7 4 T IM B E R P OST M AC A D A M 1 7 6 1 0 '-9 @ 6" P 1% VC M R IN O . O S F L O LE P A E DER DRAINS O W N (T YP I C A L ) DR IV E W A Y " UP 670.72 ) 5' 672.72 5 ' 667.62 .98 67 0 SIDEWALK NCRETE C O 670.68 669.70 (6 67 0 .7 670.52 7 3 ) 1) G " R A . " 6 IN 7 L 0 E .2 T 0 1 I N 0 V "0 P . 6 V 6 C 7.08 7 3 6 ( 24" GAS POST 5 PROPOSED TYPE 'B' INLET 3 3. 7 GRATE EL. 670.50 6 x INV 667.00 +/- (10" PVC, IN) INV 666.50 +/- (12" HDPE, OUT) 10" PVC INV. 666.92 LP 669.67 667.81 INSTALL 28 LF 12" HDPE CURB 5 6 6 3) 7 6 ( UP DN1055 RIGHT OF WAY LINE BENCHMARK 6 6 PK NAIL IN POLE 6 ELEV. 674.0 666.86 OPENAKI ROAD CONNECT TO EXISTING INLET, MATCH INVERT IN ELEV. CURB TIMBER POST 6 6 7 (TYPICAL) 6 8 6 671.71 9 6 6 DEED PROPERTY LINE LP 673.15 S42 degrees 48' 19"W 333.41' 674.98 DOUBLE YELLOW LINE OPENAKI ROAD 0 1 7 7 6 (33' ROW) 6 5 7 6 5 7 6 GRADING PLAN 0 10 20 (C)Mott MacDonald SCALE: 1" = 10' This document is issued for the party which commissioned it and for specific purposes connected with the captioned project only. It should not be relied upon by any other party or used for any other purpose. We accept no responsibility for the consequences of this document being relied upon by any other party, SCALE: 1" = 10' or being used for any other purpose, or containing any error or omission which is due to an error or omission in data supplied to us by other parties. | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 412 Mount Kemble Avenue Suite G22 Morristown NJ 07960 United States of America Certificate No. 24GA28016600 T +1 (908) 730 6000 F +1 (973) 267 2890 www.mottmacamericas.com | Client TOWNSHIP OF DENVILLE MORRIS COUNTY NEW JERSEY | REV FOR ADDENDA - DRYWELL DH JKR P REV FOR REBID - DRYWELL DETAILS DH JKR Description Ch'k'd App'd | JOHN K. RUSCHKE N. Y. Professional Engineer Lic. No 071267-1 Date 07/01/2026 | Designed RS 07/26 Drawn PL 07/26 Dwg check RS 07/26 Scale at ANSI D Status AS NTD PRE | RS | 07/26 | Eng check | RS | Title RENOVATIONS & ALTERATIONS TWO-ROOM SCHOOL HOUSE RE-BID 501 OPENAKI ROAD, DENVILLE, NJ BLOCK 20203, LOT 13 GRADING / DRAINAGE PLAN | |||||
| PL | 07/26 | Coordination | - | |||||||||||
| RS | 07/26 | Approved | JKR | |||||||||||
| Status PRE | Rev REV 0 | |||||||||||||
| 2 10 | /27/26 | SJA | ||||||||||||
| roject Number B/O 507112727-002 6 | Total 13 | |||||||||||||
| 1 10 | /13/26 | SJA | ||||||||||||
| Rev Da | te | Drawn |
668.24
668
CAPP
F
E
O
D
U
I
N
.B
D
. LANDSCAPING
U
P
N40 degrees 24' 02"E 248.51' 24"
671.49
6" PVC ROOF LEADER DRAINS
671
669 @ 1% MIN. SLOPE
670
2
7
6
3 7 6
1
L
2
ANDSCAPING
TIMB ( E TY R P P IC O A S L T ) (6 7 0 )
670.17
FLUSH CURB TC EL. 669.75
6"
P
%
V C
M
@
I
N. S
L O P E
T N E M E V A P
F O E G D E
E N IL Y T R E P O R P
D E E D
2 2
GAS/OIL FILL
EE
NN
INV. EL. 668 IILL
LEVEL LANDING YY
AA
(TYP.) WW
FF
7 7 OO
TT
HH
GG
670.33
EAVES IIRR
4
30" (6 7
1 )
'
6
0
.5
7 6
L L IS
674.75
670.68
667.64
I
W
NS
/2
T
F
A
T
L
.
L
S
T
T
H
O
R
N
E
E
E
B
(
E
3)
L
4
O W
FT
T
. D
AN
EE
K
P
S
DRYWELLS
UP 6 1 .5 7 6 L L IS PRO B P U O I S LD ED IN F G F L F R O 6 E O 7 N R 5 O . 0 E V L A E T V IO AT N IONS I 6 N 6 V 7 . EL ( . SEE DETAILS ON SHEET C107 & C1086) 6 6 6 6 5 M O U
GRAVEL BF
666.5
N
6 D 70 N .70 7 T
1
F
S
R
T
A
O
M
R
E
Y BUILDING
6
6
S
P
L E
(6 7 2 ) .X A M E P
) .P
Y T ( P M A R UP
NO. 501
6" P 22 V %% C MM @ II NN.. SS LL OO
PP EE
6 6 8
7 4
degrees 4 4 ' 4 1 "
A
E S A N T T
6 . 9
3' I
V
N
E
C
H
R
IC
EA
LE
S E
S U
O
R
F
F
M
A
O
C
T
E
O
=
R
7462 SF
671.61 2 1 :1 O L S
F
N O
R S A H M E E D
6 6 9 O AP F P S R A O N X IT IM AR AT Y E L A LO TE C R A A T L IO . N
8" 6
1 7 7
.4 6
U R
N
4 ' P
1 4' SILL 675.26 I K
W E
"
1 (
4 6
0 0' 6 7 3 2 7 6 PORCH 674.65 INV. EL. 668 6 ' R
5 7 6
N
4 6 degrees 6 7 4 T
(T
IM
YP
B
I
E
C
R
A L
P
)
OST M
DR
AC
IV
A
E
D
W
A
A
M
Y
1 7 6
5'
1 0 '-9
" UP 670.72
@ 6" P 1% VC M R IN O . O S F L O LE P A E DER DRAINS O W
)
675.34
672.72
67
C
0
O
.98
NCRETE
SIDEWALK
5
' 667.62
(6
7 3 ) 1) G " R A . " 6 IN 7 L 0 E .2 T 0
670.68
67
1 I
0
N 0
.7
V "0 P . 6 V 6 C 7.08
670.52
669.70
7 3
6
(
24" GAS POST
5 PROPOSED TYPE 'B' INLET
3
7
3.
GRATE EL. 670.50
6
x INV 667.00 +/- (10" PVC, IN)
INV 666.50 +/- (12" HDPE, OUT)
10" PVC
INV. 666.92
LP
669.67
INSTALL 28 LF 12" HDPE
667.81
CURB
5
6
6
3)
7
6
(
UP DN1055
RIGHT OF WAY LINE
BENCHMARK
6
6
PK NAIL IN POLE 6
ELEV. 674.0
CONNECT TO EXISTING INLET,
OPENAKI ROAD
666.86
MATCH INVERT IN ELEV.
CURB TIMBER POST 6 6 7
(TYPICAL) 6 8
6
671.71 9 6 6 DEED PROPERTY LINE LP
674.98
673.15
DOUBLE YELLOW LINE OPENAKI ROAD
0
S42 degrees 48' 19"W 333.41'
1 7
7 6
(33' ROW) 6
5
7
6
5
7
6
GRADING PLAN
0 10 20
(C)Mott MacDonald SCALE: 1" = 10'
This document is issued for the party which commissioned it and for specific purposes connected with the captioned project only. It should not be relied upon
by any other party or used for any other purpose. We accept no responsibility for the consequences of this document being relied upon by any other party, SCALE: 1" = 10'
or being used for any other purpose, or containing any error or omission which is due to an error or omission in data supplied to us by other parties.
Client JOHN K. RUSCHKE Title
Designed RS 07/26 Eng check RS 07/26 RENOVATIONS & ALTERATIONS
412 Mount Kemble Avenue Suite G22 TOWNSHIP OF DENVILLE
N. Y. Professional Engineer Lic. No 071267-1
Morristown NJ 07960 Drawn PL 07/26 Coordination - TWO-ROOM SCHOOL HOUSE RE-BID
MORRIS COUNTY
United States of America
501 OPENAKI ROAD, DENVILLE, NJ
Certificate No. 24GA28016600 NEW JERSEY Dwg check RS 07/26 Approved JKR 07/26
Date 07/01/2026 Scale at ANSI D Status Rev Security BLOCK 20203, LOT 13
AS NTD PRE REV 0 STD
T +1 (908) 730 6000
2 10/27/26 SJA REV FOR ADDENDA - DRYWELL DH JKR
F +1 (973) 267 2890 GRADING / DRAINAGE PLAN
Project Number B/O Total Drawing Number
www.mottmacamericas.com 1 10/13/26 SJA REV FOR REBID - DRYWELL DETAILS DH JKR
507112727-002 6 13 C104
Rev Date Drawn Description Ch'k'd App'd
668.24
668
CAPP
F
E
O
D
U
I
N
.B
D
. LANDSCAPING
U
P D
C
R
AP
Y
T
W
U
E
R
L
E
L
D
C
A
A
R
L
E
C
A
U L
=
A
1
T
,9
IO
34
N S
S .
:
F.
N40 degrees 24' 02"E 248.51' 24" (8.85"/12") RAINFALL x AREA: 1426.3 C.F. REQUIRED
671.49
(100-YR RAINFALL = 8.35" X 1.06 ADJUSTMENT FACTOR = 8.85")
DIMENSIONS: 8'-0" DIAMETER DRYWELL (INTERIOR)
671
669
9'-0" DIAMETER DRYWELL (EXTERIOR)
4'-0" DRYWELL DEPTH
2'-0" CLEAN STONE SIDES
670 2'-0" CLEAN STONE BASE
2
7
6
TIMBER POST E DRYWELL STORAGE:
3 7 6
1
L
2
ANDSCAPING
(TYPICAL)
670.17
INSTALL SILT FENCE
TT NN EE MM EE VV AA PP
FF OO EE GG DD EE
N
IL Y T R E P O R P
D E E D
STONE STO
1
1
(
N
R
1 3
4
4
e
A
'
x
t
x
G
:
1
x
3
3
E
0
'
8
x
:
x
3
6
2
.
9 '
8
x
x 2
0
0
4
x .
'
C
4
=
4
.
=
F
')
2
.
4 x
0
0
1
0 5
.
.
1
. 4 6
C
= C
. F
1 .F
.
0 . 1.80 C.F.
2 TOTAL STORAGE: DRYWELL STORAGE + STONE STORAGE
201.1 + 303.80 = 504.9 C.F.
GAS/OIL FILL
EEE
NNN
INV. EL. 668 IIILLL DRYWELLS PROVIDED: 3
YYY
AAA WWW TOTAL VOLUME PROVIDED: 504.9 x 3 = 1514.7 C.F
FFF
7 7 OOO
TTT
HHH
GGG VOLUME PROVIDED (1514.7 CF) > VOLUME REQUIRED (1426.3 CF)
EAVES IIIRRR
4
30"
'
6
0
.5
7 6
L
L
IS
667744..7755
667700..6688
667.64
UP 6 1 .5 7 6 6 6
6
L M
L
IS O
6
6 5 U
GRAVEL N
DN 77 T
1
F
S
R
T
A
O
M
R
E
Y BUILDING
66
66
S
P
L E
NO. 501 7 4 A
degrees
4
S
66 66 4 A
88 '
4
N
1 T
UP " E T
3' 671.61 6 6 9 O AP F P S R A O N X IT IM AR AT Y E L A LO TE C R A A T L IO . N 1 7 7 U R
9 FRAME 8" 6 .4
N
6 . SHED 6
4 ' P
1 4' SILL 675.26 I K
W E
"
1 (
4 6
0 0' 6 7 3 2 7 6 20' PORCH 674.65 6 ' R
5 7 6
N
4 6 degrees 6 7 4 T
(T
IM
YP
B
I
E
C
R
A L
P
)
OST M
DR
AC
IV
A
E
D
W
A
A
M
Y
1 7 6
5'
1 0 '-9
" UP 670.72
O W
)
675.34
672.72
67
C
0
O
.98
NCRETE
SIDEWALK
5
' 666677..6622
"A" INLET
670.68
67
1
0
0
.7
"0 PVC
670.52
669.70
GR. 670.20 INV. 667.08
3
24" GAS POST
'0
5
INSTALL TREE PROTECTION
10" PVC
INV. 666.92
LP
669.67
667.81
CURB
5
6
6
UP DN1055
RIGHT OF WAY LINE
BENCHMARK
6
6
PK NAIL IN POLE 6
ELEV. 674.0
OPENAKI ROAD
666.86
INSTALL INLET PROTECTION
CURB TIMBER POST 6 6 7
CakB (TYPICAL) 6 8
6
671.71 9 6 6 DEED PROPERTY LINE
674.98
673.15
DOUBLE YELLOW LINE OPENAKI ROAD
1 0 7
S42 degrees 48' 19"W 333.41' C
N
a
e
k
r
B
C
7 6
(33' ROW) 6
NerC
5
7
6
5
7
6
SOIL EROSION & SEDIMENT CONTROL PLAN
(C)Mott MacDonald SCALE: 1" = 10' 0 10 20
This document is issued for the party which commissioned it and for specific purposes connected with the captioned project only. It should not be relied upon
by any other party or used for any other purpose. We accept no responsibility for the consequences of this document being relied upon by any other party,
SCALE: 1" = 10'
or being used for any other purpose, or containing any error or omission which is due to an error or omission in data supplied to us by other parties.
Client JOHN K. RUSCHKE Title
Designed RS 07/26 Eng check RS 07/26 RENOVATIONS & ALTERATIONS
412 Mount Kemble Avenue Suite G22 TOWNSHIP OF DENVILLE
N. Y. Professional Engineer Lic. No 071267-1
Morristown NJ 07960 Drawn PL 07/26 Coordination - TWO-ROOM SCHOOL HOUSE RE-BID
MORRIS COUNTY
United States of America
501 OPENAKI ROAD, DENVILLE, NJ
Certificate No. 24GA28016600 NEW JERSEY Dwg check RS 07/26 Approved JKR 07/26
Date 07/01/2026 Scale at ANSI D Status Rev Security BLOCK 20203, LOT 13
AS NTD PRE REV 0 STD
T +1 (908) 730 6000
F +1 (973) 267 2890 SOIL EROSION AND
Project Number B/O Total Drawing Number
www.mottmacamericas.com 1 10/27/26 SJA REV FOR ADDENDA - DRYWELL DH JKR
507112727-002 9 13 C107
SEDIMENT CONTROL PLAN
Rev Date Drawn Description Ch'k'd App'd
| PRECAST CONCRETE RISER WITH PROPOSED MANHOLE LID 1.5" HMA 9.5M64 SURFACE COURSE RIM: 668.5 GREEN BORDER AND 3" HMA 19M64 BASE COURSE RESERVED LEGEND ON WHITE FINISHED GRADE PARKING BLUE DISABLE BACKGROUND 4" DENSE GRADED AGGREGATE PERSON LOGO (DGA) SUBBASE R7-8 6" P.V.C. COLLECTOR FROM ROOF DRAIN(S) 20" DIA. BASE, 1" FLOOR THICKNESS UNDISTURBED OR FOUR ANCHOR BOLTS AND ONE GROUND COMPACTED SUBGRADE LUG 6" 667 CAST ALUMINUM FINIAL AND GOLD TRIM SIGNS TO ROOF. GOLD FINISH. DOUBLE LOCK WASHERS/NUT; ADJUST TO CONFORM TO M.U.T.C.D. VAN ACCESSIBLE LEVEL LIGHT POLE. SEE BOLT PATTERN DETAIL LED MINIMUM:96 WATT 4500K COLOR TEMPERATURE TYPE 3 DISTRIBUTION. MANUFACTURER TO VERIFY MINIMUM LIGHTING INTENSITIES ARE ACHIEVED. R7-8P SET TOP OF BASE 4" ABOVE SIDEWALK DRIVEWAY/PARKING LOT CONSTRUCTION DETAIL WRAP STONE W/ PENALTY POLYCARBONATE LENS FILTER FABRIC, TYP. $250 1ST OFFENSE NTS SUBSEQUENT OFFENSES TOP OF 8'-0" (I.D.) SIDEWALK CHAMFER TO 12" BELOW TOP OF BASE DRIVER COMPARTMENT "0-'4 $250 MIN. AND/OR UP TO 90 DAYS 4" 2'-0" COMMUNITY SERVICE VERTICAL 8 - #5 BARS PRECAST CONCRETE (MIN.) 9'-0" (O.D.) TOW-AWAY ZONE SEEPAGE PIT "06 AT OWNERS EXPENSE (4000 PSI CONC.) FOUR (4) 1"x 36" HD GALV. ANCHOR BOLTS 1' - 5" PROJECTION (OR AS REQUIRED BY A A MANUFACTURER) 2" CLEAN SCH. 40, GRAY, ELECTRICAL PVC CONDUIT CRUSHED STONE TYP. ON ALL SIDES 663 AND BOTTOM CLASS 'B' CONCRETE 5'-0" "8/7 2'-0" (MIN.) "U" CHANNEL 1-'51 SIGN SUPPORT #3 REBAR @ 8" O.C. MAX. HORZ. COLOR TO MATCH EX. MUNICIPAL CLOCK TOWER 661 12' 3" CLR. 13'-0" (SQUARE) 3" 5" DIA. FLUTED POLE DRYWELL DETAIL "03 CLR. INSTALL 5" DIA. x 10 FT. GALVANIZED STEEL 8 .188 WALL THICKNESS 6061-T6 STRUCTURAL GROUND ROD GRADE ALUMINUM 24" SQU. NTS POLE WELDED FOR SINGLE UNIT CONSTRUCTION ADA PARKING SIGN DETAIL FOUNDATION GOLD TRIM NTS 4" THICK CONCRETE SIDEWALK GOLD TRIM NTS 20" DIA. BASE, 1" FLOOR THICKNESS NOTES: FOUR ANCHOR BOLTS AND ONE GROUND LUG 1. PRECAST CONCRETE FOUNDATIONS MEETING THE MINIMUM REQUIREMENTS ACCESS DOOR ARE ACCEPTABLE. 2. AT NO ADDITIONAL COST, FOUNDATIONS SHALL BE BACKFILLED WITH CLASS S LIGHT POLE CONCRETE UP TO 36 INCHES BELOW GRADE. B & B MATERIAL NOTE: ADD SHIELDS ON ALL PERIMETER LIGHTS TO ELIMINATE DIRECT LIGHTING AND SPILLAGE ON ALL RESIDENTIAL PROPERTY ANCHOR BOLT (TYP. OF 4) AS REQUIRED B 5" DIA. X 10' COPPER CLAD GROUND ROD 8 #3 TIES @ 8" O.C. BARE ROOT MATERIAL TREE AND SHRUB PLANTING DETAIL A A 8 - #5 BARS NOT TO SCALE '2 1" CHAMFER ALL SIDES B PLAN VIEW 2" SCH. 40, GRAY, ELECTRICAL PVC CONDUIT TYP. INLET FRAME & GRATE TO BE CAMPBELL PATTERN NO. 2618 WITH TYPE 'N' ECO CURB PIECE 6" 2' OR APPROVED EQUAL LADDER RUNGS ON WALL FACING ONCOMING TRAFFIC SECTION A - A 4'-0" 3'-6" (IF APPLICABLE) PRECAST CONCRETE 6" WALLS "81 PRECAST CONCRETE 6" WALLS COMPACTED NO. 57 COARSE SEIRAV 2" 1'-0" 6" AGGREGATE ALL SIDES 0.8 x DIA. VARIES CLASS 'B' CONC. INVERT 5" 6" "8 CLASS 'B' CONC. 6" OF NO. 57 COARSE AGGREGATE COMPACTED SUBGRADE SECTION "A-A" SECTION "B-B" TYPE 'B' INLET NTS (C)Mott MacDonald This document is issued for the party which commissioned it and for specific purposes connected with the captioned project only. It should not be relied upon by any other party or used for any other purpose. We accept no responsibility for the consequences of this document being relied upon by any other party, or being used for any other purpose, or containing any error or omission which is due to an error or omission in data supplied to us by other parties. | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 412 Mount Kemble Ave Morristown NJ 07960 United States of Americ Certificate No. 24GA28 T +1 (908) 730 6000 F +1 (973) 267 2890 www.mottmacamericas | Client nue Suite G22 TOWNSHIP OF DENVILLE MORRIS COUNTY a 016600 NEW JERSEY .com | JOHN K. RUSCHKE N. Y. Professional Engineer Lic. No 071267-1 Date 07/01/2026 | Designed | RS | 07/26 | Eng check | RS | 07/26 | Title RENOVATIONS & ALTERATIONS TWO-ROOM SCHOOL HOUSE RE-BID 501 OPENAKI ROAD, DENVILLE, NJ BLOCK 20203, LOT 13 CONSTRUCTION DETAILS | ||||||||||
| Drawn | PL | 07/26 | Coordination | - | |||||||||||||||
| Dwg check | RS | 07/26 | Approved | JKR | 07/26 | ||||||||||||||
| Scale at ANSI D AS NTD | Status PRE | Rev REV 0 | Security STD | ||||||||||||||||
| 2 | 10/27/26 | SJA | REV FOR ADDENDA - DRYWELL | DH | JKR | ||||||||||||||
| Project Number 507112727-002 | B/O 10 | Total 13 | Drawing Number C 108 | ||||||||||||||||
| 1 | 10/13/26 | SJA | REV FOR REBID - DRYWELL DETAILS | DH | JKR | ||||||||||||||
| RRee | vv DDaattee | DDrraawwnn | DDeessccrriippttiioonn | CChh''kk''dd | AApppp''dd |
| 8'-0" (I.D.) | |
|---|---|
| 9'-0" (O.D.) | |
PRECAST CONCRETE RISER
WITH PROPOSED MANHOLE LID
RIM: 668.5
FINISHED GRADE
6" P.V.C. COLLECTOR
FROM ROOF DRAIN(S)
8'-0" (I.D.)
2'-0"
PRECAST CONCRETE (MIN.) 9'-0" (O.D.)
SEEPAGE PIT
(4000 PSI CONC.)
2" CLEAN
CRUSHED STONE
ON ALL SIDES
AND BOTTOM
2'-0"
(MIN.)
DRYWELL DETAIL
NTS
(C)Mott MacDonald
This document is issued for the party which commissioned it and for specific purposes connected with the captioned project only. It should not be relied upon
by any other party or used for any other purpose. We accept no responsibility for the consequences of this document being relied upon by any other party,
or being used for any other purpose, or containing any error or omission which is due to an error or omission in data supplied to us by other parties.
Client JOHN K. RUSCHKE Title
Designed RS 07/26 Eng check RS 07/26 RENOVATIONS & ALTERATIONS
412 Mount Kemble Avenue Suite G22 TOWNSHIP OF DENVILLE
N. Y. Professional Engineer Lic. No 071267-1
Morristown NJ 07960 Drawn PL 07/26 Coordination -
MORRIS COUNTY
United States of America
501 OPENAKI ROAD, DENVILLE, NJ
Certificate No. 24GA28016600 NEW JERSEY Dwg check RS 07/26 Approved JKR 07/26
Date 07/01/2026 Scale at ANSI D Status Rev Security BLOCK 20203, LOT 13
AS NTD PRE REV 0 STD
T +1 (908) 730 6000
F +1 (973) 267 2890 CONSTRUCTION DETAILS
Project Number B/O Total Drawing Number
www.mottmacamericas.com
507112727-002 10 13 C 108
Rev Date Drawn Description Ch'k'd App'd
"0-'4
1.5" HMA 9.5M64 SURFACE COURSE
3" HMA 19M64 BASE COURSE
RESERVED
PARKING
4" DENSE GRADED AGGREGATE
(DGA) SUBBASE
UNDISTURBED OR
COMPACTED SUBGRADE
6"
667
SIGNS TO
CONFORM TO M.U.T.C.D.
DRIVEWAY/PARKING LOT CONSTRUCTION DETAIL WRAP STONE W/
FILTER FABRIC, TYP. $250 1ST OFFENSE
NTS SUBSEQUENT OFFENSES
663
"U" CHANNEL
SIGN SUPPORT
661
13'-0" (SQUARE)
4" THICK CONCRETE SIDEWALK
NTS
B & B MATERIAL
BARE ROOT MATERIAL
TREE AND SHRUB PLANTING DETAIL
NOT TO SCALE
"06
"03
GREEN BORDER AND
LEGEND ON WHITE
BLUE DISABLE BACKGROUND
PERSON LOGO
R7-8
VAN ACCESSIBLE
R7-8P
PENALTY
$250 MIN. AND/OR
UP TO 90 DAYS
COMMUNITY SERVICE
TOW-AWAY ZONE
AT OWNERS EXPENSE
ADA PARKING SIGN DETAIL
NTS
INLET FRAME & GRATE TO BE
CAMPBELL PATTERN NO. 2618
WITH TYPE 'N' ECO CURB PIECE
OR APPROVED EQUAL
COMPACTED NO. 57 COARSE
AGGREGATE ALL SIDES
6" OF NO. 57 COARSE
COMPACTED SUBGRADE
SEIRAV
"8
4'-0"
2"
0.8 x DIA.
"81
20" DIA. BASE, 1" FLOOR THICKNESS
FOUR ANCHOR BOLTS AND ONE GROUND
LUG
DOUBLE LOCK WASHERS/NUT; ADJUST TO
LEVEL LIGHT POLE. SEE BOLT PATTERN DETAIL
SET TOP OF BASE 4" ABOVE SIDEWALK
TOP OF
SIDEWALK CHAMFER TO 12" BELOW TOP OF BASE
4"
VERTICAL 8 - #5 BARS
FOUR (4) 1"x 36" HD GALV. ANCHOR BOLTS
- 5" PROJECTION (OR AS REQUIRED BY
A A MANUFACTURER)
SCH. 40, GRAY, ELECTRICAL PVC CONDUIT
TYP.
CLASS 'B' CONCRETE
5'-0"
#3 REBAR @ 8" O.C. MAX. HORZ.
12' 3" CLR.
3"
CLR. INSTALL 5" DIA. x 10 FT. GALVANIZED STEEL 8
GROUND ROD
24" SQU.
FOUNDATION
NOTES:
1. PRECAST CONCRETE FOUNDATIONS MEETING THE MINIMUM REQUIREMENTS
ARE ACCEPTABLE.
2. AT NO ADDITIONAL COST, FOUNDATIONS SHALL BE BACKFILLED WITH CLASS S
CONCRETE UP TO 36 INCHES BELOW GRADE.
B
A A
B
PLAN VIEW
6"
LADDER RUNGS ON WALL
FACING ONCOMING TRAFFIC
3'-6" (IF APPLICABLE)
PRECAST CONCRETE
6" WALLS
PRECAST CONCRETE
6" WALLS
1'-0" 6"
VARIES
CLASS 'B' CONC. INVERT
5"
6"
CLASS 'B' CONC.
AGGREGATE
SECTION "A-A" SECTION "B-B"
TYPE 'B' INLET
NTS
"8/7
1-'51
CAST ALUMINUM FINIAL AND
ROOF. GOLD FINISH.
LED MINIMUM:96 WATT 4500K COLOR TEMPERATURE TYPE 3 DISTRIBUTION.
MANUFACTURER TO VERIFY MINIMUM LIGHTING
INTENSITIES ARE ACHIEVED.
POLYCARBONATE LENS
DRIVER COMPARTMENT
1'
5" DIA. FLUTED POLE
.188 WALL THICKNESS 6061-T6 STRUCTURAL
GRADE ALUMINUM
POLE WELDED FOR SINGLE
UNIT CONSTRUCTION
20" DIA. BASE, 1" FLOOR THICKNESS
FOUR ANCHOR BOLTS AND ONE GROUND LUG
LIGHT POLE
5" DIA. X 10' COPPER CLAD GROUND ROD
8
2" SCH. 40, GRAY, ELECTRICAL PVC CONDUIT TYP.
SECTION A - A
'2
GOLD TRIM
COLOR TO MATCH EX. MUNICIPAL
CLOCK TOWER
GOLD TRIM
GOLD TRIM
ACCESS DOOR
NOTE:
ADD SHIELDS ON ALL PERIMETER LIGHTS TO ELIMINATE DIRECT
LIGHTING AND SPILLAGE ON ALL RESIDENTIAL PROPERTY
ANCHOR BOLT (TYP. OF 4) AS REQUIRED
#3 TIES @ 8" O.C.
8 - #5 BARS
1" CHAMFER ALL SIDES
2'
TWO-ROOM SCHOOL HOUSE RE-BID
2 10/27/26 SJA REV FOR ADDENDA - DRYWELL DH JKR
1 10/13/26 SJA REV FOR REBID - DRYWELL DETAILS DH JKR
Rev Date Drawn Description Ch'k'd App'd
| SITE PLAN - ELECTRICAL 1 SCALE |
|---|
| 20 N. Doughty Avenue Somerville, NJ 08876 t 908.722.2300 f 908.722.7201 usaarchitects.com |
|---|
| Paul R. Swartz, AIA Susan M. DeHart, AIA Armand T. Christopher Jr., AIA James McAuliffe, AIA Daniel A. Hopkins, AIA Eric DeLong, AIA |
| USA Architects, Planners and Interior Designers, LTD. NJ: 21AC00116100 PA: AX001602L DE: S7-0000564 MD: 17644 This Document is the property and copyright of USA Architects for the specified project and shall not be used or reproduced without authorization. | |||||
| RE-BID OF RENOVATIONS & ALTERATIONS AT THE TWO-ROOM SCHOOL HOUSE FOR THE TOWNSHIP OF DENVILLE PUBLIC LIBRARY 501 OPENAKI ROAD DENVILLE, NJ 07834 | |||||
| 2 | 10.28.26 | ADDENDUM #1 | |||
| 1 | 10.14.26 | ISSUED FOR RE-BID | |||
| No. | Date | Issue or Revision | |||
| Drawing Title SITE PLAN - ELECTRICAL | |||||
| Scale AS NOTED | USA Project No. 2022-117 | ||||
| Drawing Date 10.14.2026 | Drawing No. E-010 | ||||
| Drawn By SSS | Checked By MSH |
20 N. Doughty Avenue
Somerville, NJ 08876
t 908.722.2300
f 908.722.7201
usaarchitects.com
Paul R. Swartz, AIA Susan M. DeHart, AIA
Armand T. Christopher Jr., AIA James McAuliffe, AIA
Daniel A. Hopkins, AIA Eric DeLong, AIA
Strunk-Albert
Engineering
Engineered Systems and Building Consultants
This document is the sole property and copyright of SAE for the specified
project. Reproduction or use without authorization is prohibited.
804 Seven Bridge Road, Route 209
East Stroudsburg, PA 18301
T: 570.421.2025
mail@strunk-albert.com
www.strunk-albert.com
Christopher T. Strunk, P.E.
PA P.E. # 080014 NJ P.E. # 24 GE 05567000
NY P.E. # 102070-01 MD P.E. # 58301
SSS MSH MSH
drawn designed checked
drawing not valid without authorized sae signatures
SAE Project No: 23076
USA Architects, Planners and Interior Designers, LTD.
NJ: 21AC00116100 PA: AX001602L DE: S7-0000564 MD: 17644
This Document is the property and copyright of USA Architects for the
specified project and shall not be used or reproduced without
authorization.
RE-BID OF RENOVATIONS &
ALTERATIONS
AT THE
TWO-ROOM SCHOOL HOUSE
FOR THE
TOWNSHIP OF DENVILLE
PUBLIC LIBRARY
501 OPENAKI ROAD
DENVILLE, NJ 07834
2 10.28.26 ADDENDUM #1
1 10.14.26 ISSUED FOR RE-BID
No. Date Issue or Revision
Drawing Title
SITE PLAN -
ELECTRICAL
Scale USA Project No.
AS NOTED 2022-117
SITE PLAN - ELECTRICAL
1
Drawing Date Drawing No.
SCALE
10.14.2026
E-010
Drawn By Checked By
SSS MSH
| ELECTRICAL/ MECHANICAL B3 ELECTRICAL/ MECHANICAL B3 GATHERING B1 TABLE AND CHAIR TABLE STORAGE GATHERING AND B4 B1 CHAIR STORAGE B4 UNISEX UNISEX TOILET TOILET ROOM ROOM B-2 GENERAL B-2 STORAGE B5 GENERAL STORAGE B5 DRAWING NOTES - DEMO * * BASEMENT PLAN - ELECTRICAL DEMOLITION BASEMENT PLAN - POWER BASEMENT PLAN - LIGHTING * 1 2 3 * SCALE SCALE SCALE * * ASSEMBLY ASSEMBLY ASSEMBLY ASSE 2 MBLY 3 2 3 TOILET ROOM 4 STOR 7 AGE TOILET STO 3 R A AGE STO 3 R A AGE ROOM ENTRY ENTRY 5 1 TOILET 1 ST 6 AIR RO 4 OM STOR 7 AGE T R O O I 5 O LE M T ST 6 AIR DRAWING NOTES - NEW FIRST FLOOR PLAN - ELECTRICAL DEMOLITION FIRST FLOOR PLAN - POWER FIRST FLOOR PLAN - LIGHTING 4 5 6 SCALE SCALE SCALE * |
|---|
| 20 N. Doughty Avenue Somerville, NJ 08876 t 908.722.2300 f 908.722.7201 usaarchitects.com |
|---|
| Paul R. Swartz, AIA Susan M. DeHart, AIA Armand T. Christopher Jr., AIA James McAuliffe, AIA Daniel A. Hopkins, AIA Eric DeLong, AIA |
| MECHANICAL B3 GATHERING B1 TABLE AND CHAIR STORAGE B4 | ||||
|---|---|---|---|---|
| GENERAL STORAGE B5 |
| USA Architects, Planners and Interior Designers, LTD. NJ: 21AC00116100 PA: AX001602L DE: S7-0000564 MD: 17644 This Document is the property and copyright of USA Architects for the specified project and shall not be used or reproduced without authorization. RE-BID OF RENOVATIONS & ALTERATIONS | |||||
|---|---|---|---|---|---|
| AT THE TWO-ROOM SCHOOL HOUSE FOR THE TOWNSHIP OF DENVILLE PUBLIC LIBRARY 501 OPENAKI ROAD DENVILLE, NJ 07834 | |||||
| 2 | 10.28.26 | ADDENDUM #1 | |||
| 1 | 10.14.26 | ISSUED FOR RE-BID | |||
| No. | Date | Issue or Revision | |||
| Drawing Title FLOOR PLANS - ELECTRICAL | |||||
| Scale AS NOTED | USA Project No. 2022-117 | ||||
| Drawing Date 10.14.2026 | Drawing No. E-100 | ||||
| Drawn By SSS | Checked By MSH |
ELECTRICAL/
MECHANICAL 20 N. Doughty Avenue
B3
ELECTRICAL/
MECHANICAL Somerville, NJ 08876
B3
t 908.722.2300
GATHERING f 908.722.7201
B1
TABLE
AND
CHAIR TABLE
STORAGE GATHERING AND
B4 B1 CHAIR usaarchitects.com
STORAGE
B4
Paul R. Swartz, AIA Susan M. DeHart, AIA
Armand T. Christopher Jr., AIA James McAuliffe, AIA
Daniel A. Hopkins, AIA Eric DeLong, AIA
UNISEX
UNISEX TOILET
TOILET ROOM
ROOM
B-2 GENERAL B-2
STORAGE
B5
GENERAL
STORAGE
B5
Strunk-Albert
DRAWING NOTES - DEMO Engineering
Engineered Systems and Building Consultants
This document is the sole property and copyright of SAE for the specified
project. Reproduction or use without authorization is prohibited.
804 Seven Bridge Road, Route 209
* East Stroudsburg, PA 18301
* T: 570.421.2025
BASEMENT PLAN - ELECTRICAL DEMOLITION BASEMENT PLAN - POWER BASEMENT PLAN - LIGHTING
* mail@strunk-albert.com
1 2 3
* www.strunk-albert.com
SCALE SCALE SCALE *
*
Christopher T. Strunk, P.E.
PA P.E. # 080014 NJ P.E. # 24 GE 05567000
NY P.E. # 102070-01 MD P.E. # 58301
SSS MSH MSH
drawn designed checked
drawing not valid without authorized sae signatures
SAE Project No: 23076
USA Architects, Planners and Interior Designers, LTD.
NJ: 21AC00116100 PA: AX001602L DE: S7-0000564 MD: 17644
This Document is the property and copyright of USA Architects for the
specified project and shall not be used or reproduced without
ASSEMBLY
ASSEMBLY ASSEMBLY ASSE 2 MBLY 3 authorization.
2 3
RE-BID OF RENOVATIONS &
ALTERATIONS
AT THE
TWO-ROOM SCHOOL HOUSE
FOR THE
TOILET
ROOM
4 TOWNSHIP OF DENVILLE
STOR 7 AGE TOILET STO 3 R A AGE STO 3 R A AGE PUBLIC LIBRARY
ROOM ENTRY ENTRY
5 1 TOILET 1 501 OPENAKI ROAD
ST 6 AIR RO 4 OM STOR 7 AGE T R O O I 5 O LE M T ST 6 AIR DENVILLE, NJ 07834
DRAWING NOTES - NEW
FIRST FLOOR PLAN - ELECTRICAL DEMOLITION FIRST FLOOR PLAN - POWER FIRST FLOOR PLAN - LIGHTING
4 5 6
2 10.28.26 ADDENDUM #1
SCALE SCALE SCALE
1 10.14.26 ISSUED FOR RE-BID
No. Date Issue or Revision
Drawing Title
FLOOR PLANS -
ELECTRICAL
*
Scale USA Project No.
AS NOTED 2022-117
Drawing Date Drawing No.
10.14.2026
E-100
Drawn By Checked By
SSS MSH

With GovernmentContracts, you can:
Project Number Project Description/Location Estimated Project Cost Proposals Due Date / Extended Date
State of New Jersey
Bid Due: 12/08/2026
Project ID: Title: Wayne Public Library Renovations: Phase 1 Addenda: 2 Release Date:
TownShip of Wayne
Bid Due: 11/20/2026
pdf Grove Avenue and Eggert Avenue Bicycle Lanes Project RFP 26-06
Metuchen borough
Bid Due: 12/18/2026
Addendum #1 - RFB-27-01: TEC Building Demolition and Connection to Central Boiler Plant
Burlington County College
Bid Due: 12/02/2026