VOLUSIA
COUNTY SCHOOLS
"LEADING WITH GRACE AND RESPECT"
THE SCHOOL BOARD OF VOLUSIA
COUNTY FLORIDA
200 North Clara Avenue
DeLand, Florida 32720
SEABREEZE HIGH
REROOF BLDG. 7
VCS Project NO. 2648242
2700 N. OLEANDER AVENUE,
DAYTONA BEACH, FL 32118
SCHOOL BOARD
MEMBERS
RUBEN COLON
KRISTA GOODRICH
DONNA BROSEMER
JAMIE HAYNES
JESSICA THOMPSON
BOARD CHAIR
BOARD VICE CHAIR
MEMBER
MEMBER
MEMBER
CARMEN J. BALGOBIN
SUPERINTENDENT
Gale Associates, Inc.
Engineers Architects Planners
217 N. Westmonte Drive, Suite 3033
Altamonte Springs, FL 32714
P 407.599.7031 F 407.599.7077 www.gainc.com
Gale Associates (South), Inc. FL CA Lic. No: 6114
Boston Baltimore Orlando Hartford
©2025
DESCRIPTION OF WORK
REPLACEMENT OF ROOFING SYSTEMS ON BUILDING 7 ( AREA A, C & D). REPAIR EXISTING ROOF SYSTEM ON AREA B AND
APPLY A RECOVERY ROOF COATING SYSTEM.
Architect's Statement of Compliance
To the best of my knowledge, these drawings and the project manual are complete and comply with
the Florida Building Code.
BUILDING DATA
A. SURVEY PARCEL ID
B. LEGAL DESCRIPTION
C. OCCUPANCY TYPE
D. CONSTRUCTION TYPE
E. RISK CATEGORY
F. AUTOMATIC SPRINKLER
G. BUILDING AREA
H. BUILDING HEIGHT
I. OCCUPANT LOAD
N/A
N/A
N/A
N/A
III
N/A
12,200 SF (ROOFS)
25 FT (DOUBLE STORY ROOFS)
N/A
LOCATION MAP
ENGINEERS & CONSULTANTS
DISCIPLINE: ARCHITECTURAL / ENGINEERING
GALE ASSOCIATES\SOUTH\, INC.
217 N. WESTMONTE DRIVE SUITE 3033
ALTAMONTE SPRINGS, FL 32714
407-599-7031
WWW.GALEASSOCIATES.COM
ENGINEER OF RECORD: ALAN S. CRAIGO
e-mail address: ASC@GAINC.COM
PROJECT MANAGER: MATTHEW S. TANOUS
e-mail address: MST@GAINC.COM
Gale Associates, Inc.
Engineers Architects Planners
217 N. Westmonte Drive, Suite 3033
Altamonte Springs, FL 32714
P 407.599.7031 F 407.599.7077 www.gainc.com
Gale Associates (South), Inc. FL CA Lic. No: 6114
Boston Baltimore Orlando Hartford
G001
G002
A101
A301
A302
A501
A502
A503
A504
A505
A506
A507
A508
COVER SHEET
STANDARD LEGEND, SYMBOLS AND GENERAL NOTES
ROOF PLAN BLDG 7
ROOF SYSTEM INFORMATION
ROOF SYSTEM INFORMATION
DETAILS
DETAILS
DETAILS
DETAILS
DETAILS
DETAILS
DETAILS
DETAILS
NOT TO SCALE
CONSTRUCTION DOCUMENTS 04/13/2026
Engineer
Alan S. Craigo, P.E.
ARCH/ENGR OF RECORD
DESIGNED BY
ASC/MST
DRAWN BY
JWN/VL
ISSUE DATE
04/13/2026
AE PROJECT NUMBER
678444
SHEET TITLE
COVER SHEET
DRAWING NO.
G001
GENERAL NOTES
OVERALL CAMPUS PLAN
DESCRIPTION OF WORK
THE GENERAL SCOPE OF WORK FOR THIS PROJECT INCLUDES ROOF REPLACEMENT OR REPAIR AS INDICATED ON THE DRAWINGS.
1. ON LOW-SLOPED ROOF ON BUILDING 7 (AREA A): REMOVE THE EXISTING MULTI-PLY MODIFIED BITUMEN ROOFING SYSTEMS DOWN TO THE EXISTING LIGHTWEIGHT INSULATING
CONCRETE SUBSTRATE, REMOVE AND CAP ABANDON CURB WHERE INDICATED AND INSTALL NEW MODIFIED BITUMEN ROOFING SYSTEM WITH A REINFORCED PMMA SURFACING.
REFER TO SECTION 012000 - ALTERNATES FOR MORE INFORMATION ON AREA A.
2. ON LOW-SLOPED ROOF ON BUILDING 7 (AREA B): THE EXISTING MULTI-PLY MODIFIED BITUMEN ROOF IS SCHEDULED TO REMAIN. REPLACE ROOF DRAINS AND SCUPPER
FLASHINGS AND INSTALL A NEW REINFORCED PMMA COATING OVERTOP THE EXISTING ROOF. REMOVE AND REPLACE PARAPET CAPS.
3. ON LOW-SLOPED ROOF ON BUILDING 7 (AREA C): REMOVE THE EXISTING MULTI-PLY MODIFIED BITUMEN ROOFING SYSTEMS DOWN TO THE EXISTING LIGHTWEIGHT INSULATING
CONCRETE SUBSTRATE, REPAIR/ REPLACE DAMAGED OR WET AREAS OF LIGHTWEIGHT INSULATING CONCRETE AND INSTALL NEW MULTI-PLY MODIFIED BITUMEN ROOFING
SYSTEM.
4. ON LOW-SLOPED ROOF ON BUILDING 7 (AREA D): REMOVE THE EXISTING MULTI-PLY MODIFIED BITUMEN ROOFING SYSTEMS DOWN TO THE EXISTING LIGHTWEIGHT INSULATING
CONCRETE SUBSTRATE AND INSTALL NEW MULTI-PLY MODIFIED BITUMEN ROOFING SYSTEM.
DEMOLITION NOTES
1. THE INFORMATION SHOWN ON THE DRAWINGS HAS BEEN COMPILED FROM VARIOUS SOURCES, AND MAY NOT REFLECT THE ACTUAL CONDITIONS AT THE TIME OF
CONSTRUCTION. FIELD VERIFY ALL DIMENSIONS AND QUANTITIES.
2. THE BUILDING WILL REMAIN OCCUPIED DURING CONSTRUCTION. THE CONTRACTOR SHALL SCHEDULE AND EXECUTE WORK TO AVOID INTERRUPTIONS TO BUILDING
OPERATIONS.
3. CONTRACTOR SETUP LOCATIONS SHALL BE AS INDICATED BY THE OWNER DURING THE PRE-CONSTRUCTION MEETING.
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COVERING ALL INTERIOR ITEMS THAT MIGHT BE AFFECTED BY THE WORK, INCLUDING FLOORS AND EQUIPMENT PRIOR TO
DEMOLITION. ONCE REMOVAL IS COMPLETE FOR THE DAY, THE PLASTIC COVERINGS SHALL BE REMOVED AND THE INTERIOR AREAS CLEANED. CLEANING SHALL INCLUDE, BUT
NOT BE LIMITED TO, SWEEPING OF FLOORS AND DUST REMOVAL FROM THE TOPS OF LIGHT FIXTURES AND EQUIPMENT WHERE ACCESSIBLE.
5. THE CONTRACTOR SHALL REPORT DETERIORATED OR UNSUITABLE ROOF DECK OR SUBSTRATE COMPONENTS TO THE OWNER PRIOR TO PERFORMING ROOFING INSTALLATION.
6. REMOVE AND DISPOSE OF EXISTING ROOF SYSTEM AND ALL ASSOCIATED MATERIALS DOWN TO THE EXISTING STRUCTURAL DECK UNLESS OTHERWISE INDICATED ON THE
DETAIL DRAWINGS TO REMAIN. REMOVE AND DISPOSE OF ALL ITEMS TO INCLUDE ROOFING, FLASHINGS, DETERIORATED BLOCKING, AND APPURTENANCES SCHEDULED TO BE
REMOVED. REFER TO EXISTING ROOF SYSTEM CROSS SECTION INFORMATION ON THIS SHEET.
7. PROVIDE TEMPORARY OVERHEAD PROTECTION AT THE MAIN ENTRANCE AND AT OTHER LOCATIONS AS NECESSARY TO PROVIDE UNINTERRUPTED ACCESS TO BUILDING.
8. REMOVALS SHALL BE PERFORMED IN ACCORDANCE WITH THE SUBMITTED AND APPROVED REMOVAL PLAN, THE DETAIL DRAWINGS AND SPECIFICATIONS.
INSTALLATION NOTES
1. FOR THE SAKE OF CLARITY, EACH INDIVIDUAL DETAIL ON THE ROOF PLANS HAS NOT BEEN INDICATED. EXISTING AND NEW DETAILS HAVE BEEN INDICATED FOR TYPICAL
COMPONENTS AT RANDOM LOCATIONS.
2. COMPONENTS SHOWN ON THE DETAIL DRAWINGS SHALL BE NEW UNLESS SPECIFICALLY INDICATED AS EXISTING.
3. ITEMS OF CONSTRUCTION SHALL BE IN ACCORDANCE WITH LOCAL, STATE, AND FEDERAL REGULATIONS APPLICABLE TO THE PROJECT.
4. FOR THE SAKE OF CLARITY, SECUREMENT FASTENERS ARE NOT SHOWN ON THE DRAWINGS IN THEIR ENTIRETY. REFER TO SPECIFICATIONS FOR FASTENER TYPES/SPACING.
5. ANY DISCREPANCIES ON THE DRAWINGS NOTED BY THE CONTRACTOR SHALL BE BROUGHT TO THE OWNER'S ATTENTION PRIOR TO BID SUBMISSION.
6. ITEMS OF CONSTRUCTION SHALL BE 100% WATERTIGHT ON THE SAME DAY OF WORK. PHASED CONSTRUCTION MUST BE APPROVED BY THE OWNER PRIOR TO CONSTRUCTION.
7. DETAILS NOT DEPICTED SHALL BE CONSTRUCTED IN A MANNER CONSISTENT WITH THE DETAIL DRAWINGS. FIELD VERIFY ALL DIMENSIONS.
8. IF THERE IS A POTENTIAL HAZARDOUS MATERIAL ENCOUNTERED DURING THE COURSE OF WORK THAT IS NOT IDENTIFIED IN THE CONTRACT DOCUMENTS, THE CONTRACTOR
WILL STOP WORK IMMEDIATELY AND CONTACT THE OWNER WHO IS TO MAKE A DETERMINATION IF THE MATERIAL IS HAZARDOUS.
9. ALL DUMPSTERS MUST BE AT LEAST 15 FEET FROM THE BUILDING UNLESS EMPTIED AT THE END OF EACH WORK DAY.
10. MATERIALS MAY NOT BE STORED CLOSER THAN 15 FEET FROM BUILDINGS AND MAY NOT BE PLACED IN FRONT OF EXITS OR ANY FIRE PROTECTION EQUIPMENT. REFUELING OF
GASOLINE POWERED EQUIPMENT WILL NOT BE PERMITTED ON THE ROOF. GASOLINE MUST BE STORED IN UL LISTED AND APPROVED CONTAINERS.
11. METAL FABRICATION NOTES: FILE SMOOTH ALL EXPOSED SHARP EDGES. FABRICATE METAL TRANSITIONS AND TERMINATIONS IN ONE-PIECE CONSTRUCTION. LOCK AND SEAL OR
SOLDER ALL JOINTS SOLID, AS SPECIFIED, TO MAKE WATERTIGHT.
STATEMENT OF COMPLIANCE
1. TO THE BEST OF MY KNOWLEDGE, THESE DRAWINGS AND THE PROJECT MANUAL ARE COMPLETE AND COMPLY WITH THE FLORIDA BUILDING CODE.
2. BUILDING CODE REFERENCE: FLORIDA BUILDING CODE, 8TH EDITION (2023).
N.I.C.
N.I.C.
N.I.C.
N.I.C.
N.I.C.
N.I.C.
N.I.C.
N.I.C.
N.I.C.
BUILDING 7
N.I.C.
N.I.C.
AREA C
BUILDING 7:
SEE ROOF PLAN SHEET A101
AREA D
AREA A
AREA B
N.I.C.
NORTH
CAMPUS PLAN
SCALE: N.T.S.
N.I.C. = NOT IN CONTRACT
STANDARD LEGEND AND SYMBOLS
NOTE: NOT ALL SYMBOLS NECESSARILY USED
ROOF EDGE
PARAPET
CRICKET
VP
VENT PIPE (DIAMETER SHOWN)
4
PRIMARY 4 INCH ROOF DRAIN
PRIMARY SCUPPERS
OF
F
SECONDARY SCUPPERS
EXHAUST FAN
V
GRAVITY VENT
H
ROOF HATCH
ABANDONED PENETRATION
LIGHTNING PROTECTION DOWN CONDUCTOR
TAPERED INSULATION SLOPE
STRUCTURAL SLOPE
EXPANSION JOINT
VP
EXHAUST VENT STACK
DETAIL IDENTIFIER
1
A500
SHEET WHERE DETAILS SHOWN
SECTION INDICATOR
DETAIL IDENTIFIER
1
A500
SHEET WHERE DETAILS SHOWN
DETAIL INDICATOR
BUILDING 7 ROOF AREA SUMMARY
AREA #
SQUARE
FOOTAGE (SF)
ROOF
SLOPE
EXISTING
ROOF
NEW ROOF
A
9,450 S.F.
1/8 : 12
MOD. BIT. MOD-BIT WITH REINF.
OVER LWIC* PMMA SURFACING
MOD. BIT. ROOF RECOVER WITH
B
2,000 S.F.
1/4 : 12 OVER RIGID REINFORCED PMMA
INSULATION
SURFACING
C
650 S.F.
1/4 : 12
MOD. BIT.
OVER LWIC
MOD. BIT. OVER LWIC
D
100 S.F.
1/8 : 12
MOD. BIT.
OVER LWIC
MOD. BIT. OVER LWIC
TOTAL
12,200 S.F.
NOTE: SEE SHEET A301 FOR ROOF SYSTEM
INFORMATION
TABLE LEGEND
SF
= SQUARE FEET
MOD. BIT. = MODIFIED BITUMEN MEMBRANE ROOFING
LWIC = LIGHTWEIGHT INSULATING CONCRETE
NOTE: QUANTITIES ARE PROVIDED TO ASSIST BIDDERS IN ESTABLISHING THE
PROJECT SCOPE. FIELD VERIFY ALL EXISTING CONDITIONS, DIMENSIONS AND
QUANTITIES PRIOR TO SUBMITTING A BID FOR THIS PROJECT.
* ROOF AREA A CONSISTS OF 2 LAYERS OF EXISTING ROOFING WITH 2
LAYERS OF LIGHTWEIGHT CONCRETE SUBSTRATES.
*REFER TO SECTION 012300 - ALTERNATES FOR ROOF AREA.A
SPECIFIED PER FLORIDA BUILDING CODE (2023) CH. 16
AND IN ACCORDANCE WITH ASCE 7-22
ULTIMATE DESIGN WIND SPEED
155 MPH
NOMINAL DESIGN WIND SPEED
120 MPH
BUILDING RISK CATEGORY
III
WIND EXPOSURE
EXPOSURE C
INTERNAL PRESSURE COEFFICIENT
0.18 (ENCLOSED)
BUILDING HEIGHT (DESIGN MEAN)
25 FT
DESIGN WIND LOAD PRESSURES IN PSF
(BASED ON NOM. WIND SPEED)
ZONE 1'
1'
ZONE 1
1
ZONE 2
2
ZONE 3
3
N/A
-55.43
-73.12
-99.66
* ANSI/SPRI ES-1 TEST METHODS FOR COPINC CAP AND
EDGE METAL SYSTEMS:
- MIN. HORIZONTAL LOAD: 108 PSF (CORNERS 134 PSF)
- MIN. VERTICAL LOAD: 186 PSF (CORNERS 280 PSF)
WIND DESIGN INFORMATION
15'-0"
TYP.
3
3
5'-0" TYP.
2
5'-0"
TYP.
2
2
1
3
3
15'-0"
TYP.
3
2
5'-0" TYP.
3
WIND LOAD SCHEMATIC
SCALE = N.T.S.
15'-0"
TYP.
3
1
2
5'-0" TYP.
3
3
2
3
15'-0"
TYP.
2
15'-0"
TYP.
3
Gale Associates, Inc.
Engineers Architects Planners
217 N. Westmonte Drive, Suite 3033
Altamonte Springs, FL 32714
P 407.599.7031 F 407.599.7077 www.gainc.com
Gale Associates (South), Inc. FL CA Lic. No: 6114
Boston Baltimore Orlando Hartford
©2025
Engineer
Alan S. Craigo, P.E.
ARCH/ENGR OF RECORD
DESIGNED BY
ASC/MST
DRAWN BY
JWN/VL
ISSUE DATE
04/13/2026
AE PROJECT NUMBER
678444
SHEET TITLE
STANDARD LEGEND,
SYMBOLS AND
GENERAL NOTES
DRAWING NO.
G002
KEY NOTES
ROOF REPLACEMENT NOTES
ALTERNATE NO. 1
1 REMOVE EXISTING ABANDONED PIPE PENETRATINS THROUGH THE ROOF, FILL IN ROOF AS
INDICATED AND ROOF OVER. SEE DETAIL 5/A501.
2 POWERWASH SURFACES OF (EACH) EXISTING PAINTED CONCRETE EYEBROWS, REMOVE
EXISTING LOOSE COATINGS, AND APPLY A NEW ACRYLIC WATERPROOF COATING AS
SPECIFIED (WITH INTEGRAL WHITE FINISH COLOR). SEE DETAIL 2/A501 (QTY 14, VERIFY).
1. ROOF AREA A, C & D
1.1. REMOVE EXISTING MULTI-PLY MODIFIED BITUMEN ROOF ASSEMBLY (AND MECHANICALLY ATTACHED
BASE SHEET) DOWN TO THE EXISTING LIGHTWEIGHT INSULATING CONCRETE (LWIC) SUBSTRATE.
INSTALL NEW MULTI-PLY MODIFIED BITUMEN ROOFING SYSTEM (WITH MECHANICALLY ATTACHED
BASE SHEET) AS SPECIFIED. REFER TO ROOF SYSTEM CROSS SECTION INFORMATION, SHEET A301.
ROOF AREA A: AS AN ALTERNATE TO THE BASE BID SCOPE OF WORK, WHICH INCLUDES
THE APPLICATION OF REINFORCED PMMA SURFACING OVER THE NEW MODIFIED BITUMEN
ROOFING SYSTEM, PROVIDE AN ALTERNATE (DEDUCT) COST FOR INSTALLING A 3-PLY
MODIFIED BITUMEN ROOF SYSTEM (2 BASE-PLIES WITH 1 GRANULE SURFACED CAP SHEET
PLY WITH BRIGHT WHITE GRANULES). REFER TO SECTION 012300-ALTERNATES
3 AT EXISTING LOCATIONS WHERE THERE IS EVIDENCE OF A HISTORY OF STANDING WATER,
REMOVE EXISTING ROOFING DOWN TO THE EXISTING LIGHTWEIGHT INSULATING CONCRETE
(LWIC) SUBSTRATE. CUT OUT AND REMOVE TOP SURFACE (APPROX. 2-INCHES) OF LWIC AND
REPAIR AS SPECIFIED AND FLOAT SURFACE OF LWIC TO MAINTAIN POSITIVE ROOF SLOPE TO
HELP ELIMINATE EXISTING “FLAT AREAS” WHERE STANDING WATER OCCURS. SEE DETAILS
5/A301 (QTY. UP TO 40 SF).
4 REMOVE AND REPLACE EXHAUST VENT/CAP AT EXISTING VENT FLUE ON AREA B AS
INDICATED. CORROSION TREAT AND APPLY PMMA FLASHING ONTO EXISTING GALVANIZED
FLUE. INSPECT EACH VENT FROM SOURCE BELOW, DO NOT INSTALL SCREEN WITH VENT CAP
AT ANY DRYER VENTS. SEE DETAIL 1/A504.
5 INSTALL NEW SECONDARY (OVERFLOW) SCUPPERS THROUGH THE EXISTING PARAPET
WHERE INDICATED (SIZE: 10”W X 4”H). LOCATE SECONDARY SCUPPERS WITHIN 2-FT MIN. OR
4-FT MAX. FROM THE EXISTING PRIMARY SCUPPERS. FIELD VERIFY EXISTING WALL
CONSTRUCTION PRIOR TO INSTALLING SECONDARY SCUPPERS. SEE DETAIL 5/A504.
6 REMOVE AND REPLACE EXISTING ROOF DRAINS WHERE INDICATED ON AREA B, REPLACING
ROOFING AND INSULATION AROUND EACH DRAIN TO FORM A 4-FT X 4-FT SUMP, AND TIE BACK
INTO THE EXISTING ROOFING SYSTEM PRIOR TO THE APPLICATION OF THE NEW REINFORCED
PMMA ROOF SURFACING. SEE DETAIL 1/A503.
1.2. ROOF AREA A: APPLY A REINFORCED FLUID-APPLIED PMMA SURFACE OVER TOP OF THE NEW
MODIFIED BITUMEN MEMBRANE ROOF AS INDICATED (AREA A ONLY). *SEE ALTERNATE NO. 1.
1.3. ROOF AREA C: REPLACE EXISTING SCUPPER DRAIN FLASHINGS, CONDUCTOR BOXES AND
DOWNSPOUTS AND INSTALL NEW OVERFLOW SCUPPERS AS INDICATED.
1.4. SLOPE IS BUILT INTO THE EXISTING LWIC ROOF SUBSTRATE, SEE ROOF PLAN BELOW.
2. ROOF AREA B
2.1. EXISTING MULTI-PLY MODIFIED BITUMEN ROOF MEMBRANE IS SCHEDULED TO REMAIN IN PLACE.
REPAIR EXISTING ROOFING AND FLASHING AND INSTALL NEW REINFORCED FLUID-APPLIED PMMA
SURFACING AS INDICATED. REFER TO ROOF SYSTEM CROSS SECTION INFORMATION, DETAIL 3/A301.
2.2. REPLACE ROOF DRAINS AND OVERFLOW SCUPPERS FLASHINGS AS INDICATED.
2.3. SLOPE IS BUILT INTO THE EXISTING STEEL ROOF DECK, SEE ROOF PLAN BELOW.
3. PROVIDE ROOF PROTECTION (WALKWAY) PATHS WHERE INDICATED ON
THE ROOF PLAN, INCLUDING AROUND SERVICEABLE ROOFTOP
EQUIPMENT. COORDINATE PLACEMENT AND LAYOUT WITH OWNER.
7 REMOVE AND REPLACE EXISTING SECONDARY (OVERFLOW) SCUPPER FLASHINGS (SIZE: 8”W
X 4”H) AND TIE BACK INTO THE EXISTING ROOFING SYSTEM PRIOR TO THE APPLICATION OF
3.1. NOTE: FOR FLUID-APPLIED ROOF SURFACE AREAS, WALKWAYS (OR WALKPATHS) MAY BE PROVIDED
USING AN ADDITIONAL LAYER OF GREY-COLORED PMMA SURFACING WITH SKID RESISTANT FINISH
THE NEW REINFORCED PMMA ROOF SURFACING. SEE DETAIL 2/A503.
4. ROOFTOP LIGHTNING PROTECTION: REMOVE AND REPLACE EXISTING ALUMINUM ROOFTOP LIGHTNING
2
8 PROVIDE CONCRETE SPLASH BLOCK AT THE BASE OF DOWNSPOUTS AS SPECIFIED.
PROTECTION SYSTEM TO ACCOMMODATE ROOF REPLACEMENT AS INDICATED. INSTALL NEW
COMPONENTS TO REPLACE MISSING OR DAMAGED TO PROVIDE A COMPLETE SYSTEM AS SPECIFIED.
A505
2
A506
N.I.C.
2 TYP.
2 TYP.
1
A501
TYP.
165'-6"±
2 TYP.
1
A505
LIGHTNING PROTECTION
THROUGH COPING CAP, SEE
1/A508
5
VP
3
VP
A504
OF
EXISTING J-BOX THRU
ROOF FLASHINGS,
SEE 6/A504
8
2
A504
41'-6"±
3
A501
WALKWAY, SEE
NOTE 3.1 ABOVE
8
4
A504
OF
5
VP
VP
2
A502
F
SIM.
WALKWAY, SEE
NOTE 3.1 ABOVE
VP
HISTORY OF STANDING WATER
IN THESE LOCATIONS, TYP. 3
3
VP
A502
TYP.
VP
VP
VP
3
VP
A502
TYP.
3
A502 TYP. VP
4
A501
HISTORY OF STANDING WATER
IN THESE LOCATIONS, TYP. 3
ADJACENT ROOF (N.I.C.)
RAISED EXPANSION JOINT
WALKWAY
1
A501
TYP.
LIGHTNING PROTECTION
THROUGH COPING CAP, SEE
1/A508
16'-0"±
1
A506
N.I.C.
PROVIDE GUTTERS AT ROOF CORNER
WHERE INDICATED (EXTEND MIN. 6-FT IN
EACH DIRECTION FROM CORNER, TYP.),
SEE 4/A502
NOTE: PROVIDE SPLASH PAN AT BASE
OF DOWNSPOUT ON EXISTING CANOPY,
SEE 3/A507
VP
DS
1
1
A501
TYP.
WALKWAY, SEE
NOTE 3.1 ABOVE
VP V
1
A502
H
6
A501
PROVIDE SAFETY RAILING AT
ROOF HATCH EGRESS AREA TO
MEET CODE REQUIREMENTS,
EXTEND MIN. 48-INCHES
BEYOND EDGE OF HATCH,
SEE 5/A502
1
A501
TYP.
HISTORY OF STANDING WATER
IN THESE LOCATIONS, TYP. 3
2 TYP.
2 TYP.
5
A506
5
A503
4
A503
3
A508
46
2 TYP.
DS
1
3
A501 A503
TYP.
3
A503
1
A501
TYP.
VP VP VP
6
4
4
A503
46
46
5
A503
48'-6"±
N.I.C.
5
A506
SIM.
PROVIDE GUTTERS AT ROOF CORNER
WHERE INDICATED (EXTEND MIN. 6-FT IN
EACH DIRECTION FROM CORNER, TYP.),
SEE 4/A502
NOTE: EXTEND DOWNSPOUT TO DEPOSIT
RUNOFF TO ROOF BELOW AND PROVIDE
CONCRETE SPLASHBLOCK SET IN
ADHESIVE ONTO ROOF SURFACE.
OF
7
PLAN
NORTH
1 ROOF PLAN BUILDING 7
A101 SCALE: 1/8"=1'-0"
OF
64'-6"±
7
OF
5
7
A503
Gale Associates, Inc.
Engineers Architects Planners
217 N. Westmonte Drive, Suite 3033
Altamonte Springs, FL 32714
P 407.599.7031 F 407.599.7077 www.gainc.com
Gale Associates (South), Inc. FL CA Lic. No: 6114
Boston Baltimore Orlando Hartford
©2025
Engineer
Alan S. Craigo, P.E.
ARCH/ENGR OF RECORD
DESIGNED BY
ASC/MST
DRAWN BY
JWN/VL
ISSUE DATE
04/13/2026
AE PROJECT NUMBER
678444
SHEET TITLE
DRAWING NO.
ROOF PLAN
BLDG 7
A101
EXISTING 2-PLY MODIFIED BITUMEN ROOF
MEMBRANE SYSTEM AND MECHANICALLY ATTACHED
BASE SHEET, TO BE REMOVED
EXISTING TAPERED CELLULAR LIGHTWEIGHT
INSULATING CONCRETE (LWIC), TO REMAIN
· LWC TOPPING AVERAGE 2" THICK
· EPS INSULATION VARIES TYP. 1" TO 8"±
EXISTING MODIFIED BITUMEN ROOF SYSTEM WITH
MECHANICALLY ATTACHED BASE SHEET, TO REMAIN
EXISTING CELLULAR LIGHTWEIGHT CONCRETE,
TO REMAIN
EXISTING ROOF SYSTEM
EXISTING CORRUGATED STEEL FORM DECK,
TO REMAIN
REINFORCED FLUID APPLIED (PMMA) SURFACING
OVER (NEW) MODIFIED BITUMEN ROOF SYSTEM,
SEE 4/A302
MODIFIED BITUMEN ROOF MEMBRANE: SMOOTH
SURFACED BASE-PLY MEMBRANE OVER MECH.
ATTACHED BASE SHEET (TORCH APPLIED)
MECHANICALLY ATTACHED BASE SHEET
EXISTING TAPERED CELLULAR LIGHTWEIGHT
INSULATING CONCRETE (LWIC)
· LWC TOPPING AVERAGE 2" THICK
· EPS INSULATION VARIES TYP. 1" TO 5"±
EXISTING MODIFIED BITUMEN ROOF SYSTEM WITH
MECHANICALLY ATTACHED BASE SHEET
EXISTING CELLULAR LIGHTWEIGHT CONCRETE
NEW ROOF SYSTEM
EXISTING CORRUGATED STEEL FORM DECK
NOTE: REFER TO ALTERNATE DETAIL 6/A302 AND SECTION 012300 - ALTERNATES FOR ROOF AREA A.
1 ROOF SYSTEM CROSS SECTION INFORMATION (AREA A)
A301 SCALE: 3"=1'-0"
(ALL ITEMS ARE NEW UNLESS DESIGNATED AS EXISTING)
EXISTING 2-PLY MODIFIED BITUMEN ROOF MEMBRANE:
GRANULAR SURFACED CAP SHEET OVER SMOOTH
BASE-PLY MEMBRANE, TO REMAIN
EXISTING 5/8" THICK GYPSUM
COVERBOARD, TO REMAIN
EXISTING ROOF SYSTEM
REINFORCED FLUID APPLIED (PMMA) SURFACING OVER
(EXISTING) MODIFIED BITUMEN ROOF SYSTEM,
SEE 5/A302
EXISTING 2-PLY MODIFIED BITUMEN ROOF MEMBRANE:
GRANULAR SURFACED CAP SHEET OVER SMOOTH
BASE-PLY MEMBRANE
EXISTING 5/8" THICK GYPSUM BOARD,
TO REMAIN
EXISTING 3" POLYISOCYANURATE
INSULATION, TO REMAIN
EXISTING SLOPED TYPE -B STEEL DECK,
TO REMAIN
EXISTING 5/8" THICK
GYPSUM COVERBOARD
NEW ROOF SYSTEM
EXISTING 5/8" THICK GYPSUM
COVERBOARD
EXISTING 3" POLYISOCYANURATE
INSULATION
EXISTING SLOPED TYPE -B STEEL DECK
NOTE: FOR TYP. ROOF REPAIRS, SEE 5/A301
2 ROOF SYSTEM CROSS SECTION INFORMATION (AREA B)
A301 SCALE: 3"=1'-0"
(ALL ITEMS ARE NEW UNLESS DESIGNATED AS EXISTING)
EXISTING ROOF SYSTEM
EXISTING 2-PLY MODIFIED BITUMEN ROOF
MEMBRANE SYSTEM AND MECHANICALLY
ATTACHED BASE SHEET, TO BE REMOVED
EXISTING TAPERED CELLULAR LIGHTWEIGHT
INSULATING CONCRETE (LWIC), TO REMAIN
· LWC TOPPING AVERAGE 3" THICK
· EPS INSULATION VARIES TYP. 3.5" TO 8"±
EXISTING CORRUGATED STEEL FORM DECK,
TO REMAIN
Gale Associates, Inc.
Engineers Architects Planners
217 N. Westmonte Drive, Suite 3033
Altamonte Springs, FL 32714
P 407.599.7031 F 407.599.7077 www.gainc.com
Gale Associates (South), Inc. FL CA Lic. No: 6114
Boston Baltimore Orlando Hartford
©2025
2-PLY MODIFIED BITUMEN ROOF MEMBRANE:
GRANULAR SURFACED CAP SHEET OVER SMOOTH
BASE-PLY MEMBRANE (TORCH APPLIED)
MECHANICALLY ATTACHED BASE SHEET
EXISTING TAPERED CELLULAR LIGHTWEIGHT
INSULATING CONCRETE (LWIC), TO REMAIN
· LWC TOPPING AVERAGE 3" THICK
· EPS INSULATION VARIES TYP. 3.5" TO 8"±
NEW ROOF SYSTEM
NOTE: FOR TYP. LWIC REPAIRS, SEE 6/A301
EXISTING CORRUGATED STEEL FORM DECK
3 ROOF SYSTEM CROSS SECTION INFORMATION (AREA C)
A301 SCALE: 3"=1'-0"
(ALL ITEMS ARE NEW UNLESS DESIGNATED AS EXISTING)
EXISTING ROOF SYSTEM
EXISTING 2-PLY MODIFIED BITUMEN ROOF
MEMBRANE SYSTEM AND MECHANICALLY
ATTACHED BASE SHEET, TO BE REMOVED
EXISTING TAPERED CELLULAR LIGHTWEIGHT
INSULATING CONCRETE (LWIC), TO REMAIN
EXISTING PRECAST CONCRETE DECK,
TO REMAIN
2-PLY MODIFIED BITUMEN ROOF MEMBRANE:
GRANULAR SURFACED CAP SHEET OVER SMOOTH
BASE-PLY MEMBRANE (TORCH APPLIED)
MECHANICALLY ATTACHED BASE SHEET
EXISTING TAPERED CELLULAR LIGHTWEIGHT
INSULATING CONCRETE (LWIC)
EXISTING PRECAST CONCRETE DECK
NEW ROOF SYSTEM
NOTE: FOR TYP. LWIC REPAIRS, SEE 6/A301
4 ROOF SYSTEM CROSS SECTION INFORMATION (AREA D)
A301 SCALE: 3"=1'-0"
(ALL ITEMS ARE NEW UNLESS DESIGNATED AS EXISTING)
CUT OUT AND REMOVE BLISTERED MEMBRANE OR WHERE
WRINKLES OR OTHER DAMAGE IS OBSERVED, REPAIR BACK TO
WHERE EXISTING SUBSTRATE MATERIAL IS SOUND AND DRY
CUT OUT AND REMOVE EXISTING INSULATION SUBSTRATE
MATERIALS WHERE FOUND TO BE DAMAGED OR IF MOISTURE
IS IDENTIFIED, REPAIR BACK TO EXISTING GOOD (SOUND/DRY)
SUBSTRATE; FOR SUBSTRATE MATERIALS REFER TO 2/A301
STEP 1
EXISTING STEEL ROOF DECK
REINFORCED FLUID-APPLIED (PMMA) ROOF COATING SYSTEM
CONTINUOUS OVER THE WHOLE ROOF AREA (APPLY AFTER
PATCH HAS CURED)
COVER REPAIR AREA WITH MIN. 1-LAYER OF GRANULAR
SURFACED MODIFIED BITUMEN ROOFING MEMBRANE,
TORCH-ADHERE AND EXTEND MIN. 4" ONTO ADJACENT
EXISTING ROOF SURFACE (DE-GRANULATE CAP SHEET
AT OVERLAP TO ENSURE ADHESION ); THEN APPLY
REINFORCED FLUID-APPLIED MEMBRANE PATCH, EXTEND
PATCH MIN. 6" BEYOND THE REPAIR
INSTALL SAME NUMBER OF PLIES AS ARE REMOVED, BUILD
UP DEPRESSION IN ROOFING AT PATCH LOCATION TO MAKE
SURFACE LEVEL
EXISTING MODIFIED BITUMEN ROOFING WITH GRANULAR
SURFACED CAP SHEET
STEP 2
REPLACE EXISTING INSULATION SUBSTRATE MATERIALS ONLY
AS REQUIRED TO ADDRESS DAMAGE, AS INDICATED ABOVE
EXISTING STEEL ROOF DECK
5 TYP. REPAIRS TO EXISTING ROOF ASSEMBLY (AREA B)
A301 SCALE: 3" = 1'-0"
(ALL ITEMS ARE NEW UNLESS DESIGNATED AS EXISTING)
REMOVE AND REPLACE ROOFING
AS INDICATED, SEE 1/A301
ROOF AREA A
REMOVE AND REPLACE ROOFING
AS INDICATED, SEE 3/A301
INSPECT UNDERLYING LIGHTWEIGHT INSULATING
CONCRETE (LWIC) SUBSTRATES FOR DAMAGE OR
MOISTURE, CUT OUT AND PATCH AS SPECIFIED
(FLOAT TO MAINTAIN POSITIVE ROOF SLOPE AND
ALLOW TO CURE BEFORE INSTALLING ROOFING)
REMOVE DAMAGED OR WET LWIC BACK TO
SOUND/DRY SUBSTRATE MATERIALS
CUT OUT AND REPLACE EXISTING RIGID
POLYSTYRENE INSULATION BOARDS AT
ISOLATED AREAS TO FACILITATE REPAIRS
AT REPAIR AREAS, INSPECT FOR MOISTURE
BETWEEN ROOF SYSTEMS AND VACUUM OUT
MOISTURE WHERE OBSERVED
EXISTING ASPHALT MEMBRANE ROOF SYSTEM
(BETWEEN LWIC LAYERS). PATCH OR REPAIR
WHERE DAMAGED DURING DEMO PROCEDURES
EXISTING LIGHTWEIGHT CONCRETE ON
CORRUGATED STEEL FORM DECK
INSPECT UNDERLYING LIGHTWEIGHT INSULATING
CONCRETE (LWIC) SUBSTRATES FOR DAMAGE OR
MOISTURE, CUT OUT AND PATCH AS SPECIFIED
(FLOAT TO MAINTAIN POSITIVE ROOF SLOPE AND
ALLOW TO CURE BEFORE INSTALLING ROOFING)
REMOVE DAMAGED OR WET LWIC BACK TO
SOUND/DRY SUBSTRATE MATERIALS
CUT OUT AND REPLACE EXISTING RIGID
POLYSTYRENE INSULATION BOARDS AT
ISOLATED AREAS TO FACILITATE REPAIRS
ROOF AREA C, D
EXISTING CORRUGATED STEEL FORM DECK
6 TYP. REPAIRS TO LWIC (AREA A, C, D)
A301 SCALE: 3" = 1'-0"
(ALL ITEMS ARE NEW UNLESS DESIGNATED AS EXISTING)
Engineer
Alan S. Craigo, P.E.
ARCH/ENGR OF RECORD
DESIGNED BY
ASC/MST
DRAWN BY
JWN/VL
ISSUE DATE
04/13/2026
AE PROJECT NUMBER
678444
SHEET TITLE
ROOF SYSTEM
INFORMATION
DRAWING NO.
A301
8"
MIN.
3"
4" MIN.
SECTION
EXTEND ROOF
MEMBRANE ABOVE HEAD
OF CANT AND ADHERE
TO WALL OR ROOF CURB
TERMINATION BAR
2-PLY MODIFIED BITUMEN
BASE FLASHING
LOW PROFILE
FIBER CANT
2" MIN.
NOTE: FIBER CANT STRIPS MAY BE ELIMINATED
WHEN USING POLYESTER - REINFORCED
MEMBRANE BASE FLASHINGS, WITH ROOF
SYSTEM MANUFACTURER WRITTEN CONSENT.
NOTE: FOR WOOD OR PLYWOOD SUBSTRATES,
UTILIZE A SELF-ADHERING BASE PLY FLASHING
MEMBRANE WITH TOP SURFACE CAPABLE OF
TORCHING TOP PLIES, AS SPECIFIED.
ROOF CURB OR RISING WALL
NEW MODIFIED BITUMEN BASE FLASHING
MEMBRANE (SMOOTH), UP AND OVER TOP
OF CURB/WALL AS SHOWN
SEE SHEET A301
EXISTING OR NEW ROOFING
AND BASE FLASHINGS,
REFER TO ROOF SYSTEM
ASSEMBLY INFORMATION
ON SHEET A302, AND SEE
DETAIL 1/A302
GRANULAR SURFACED MODIFIED BITUMEN
BASE FLASHING CAP PLY
SEE SHEET A301
ROOF CURB OR RISING WALL
REINFORCED FLUID-APPLIED (PMMA)
BASE FLASHING SYSTEM
REINFORCED FLUID-APPLIED (PMMA) ROOF
SURFACING OR COATING SYSTEM
GRANULAR SURFACED MODIFIED
BITUMEN ROOF MEMBRANE CAP SHEET
SEE SHEET A301
MODIFIED BITUMEN ROOF MEMBRANE BASE
PLY (SMOOTH)
SEE SHEET A301
LOW PROFILE FIBER CANT STRIP, SET IN
ADHESIVE AND APPLY PRIMER OVER FACE
TO RECEIVE ROOFING
LIGHTWEIGHT INSULATING CONCRETE (LWIC)
SUBSTRATE (BASE SHEET NOT SHOWN)
SEE SHEET A301
1 TYP. MOD. BIT. MEMBRANE BASE FLASHING INSTALLATION
A302 SCALE: 3"=1'-0"
(ALL ITEMS ARE NEW UNLESS DESIGNATED AS EXISTING)
CLEAN AND PREP ROOF SURFACE TO
RECEIVE FLUID-APPLIED ROOFING AND
FLASHING SYSTEM(S)
2 TYP. FLUID-APPLIED BASE FLASHING
A302 SCALE: 3"=1'-0"
(ALL ITEMS ARE NEW UNLESS DESIGNATED AS EXISTING)
EXISTING OR NEW ROOFING AND
FLASHINGS, REFER TO ROOF SYSTEM
ASSEMBLY INFORMATION ON SHEET A302
ROOFING SUBSTRATE VARIES
SEE SHEET A301
FLUID-APPLIED ROOF COATING TOP
COAT, 2-LAYERS (OR AS REQUIRED
TO MEET SPECIFIED WARRANTY
REQUIREMENTS), ENTIRE ROOF
FLUID-APPLIED ROOF COATING,
BASE COAT
POLYESTER
REINFORCEMENT FABRIC
FLUID-APPLIED ROOF COATING TOP
COAT, 2-LAYERS (OR AS REQUIRED
TO MEET SPECIFIED WARRANTY
REQUIREMENTS), ENTIRE ROOF
FLUID-APPLIED ROOF COATING,
BASE COAT
POLYESTER
REINFORCEMENT FABRIC
REINFORCED FLUID-APPLIED (PMMA) SURFACING
OVER MODIFIED BITUMEN ROOF SYSTEM WHERE
SPECIFIED, SEE SHEET A301
Gale Associates, Inc.
Engineers Architects Planners
217 N. Westmonte Drive, Suite 3033
Altamonte Springs, FL 32714
P 407.599.7031 F 407.599.7077 www.gainc.com
Gale Associates (South), Inc. FL CA Lic. No: 6114
Boston Baltimore Orlando Hartford
MODIFIED BITUMEN ROOF
6"
MEMBRANE STRIPPING PLY
METAL FLANGE, PRIME BOTH
SIDES, SET IN ROOF MASTIC AND
FASTEN TO WOOD BLOCKING
©2025
EDGE METAL
TURN BASE PLY MEMBRANE DOWN
OVER FACE BEHIND METAL TO
COVER WOOD BLOCKING OR
WRAP EDGE WITH SELF-ADHERED
MEMBRANE FLASHING
PERIMETER WOOD BLOCKING, TO
MATCH INSULATION HEIGHT AND
FLUSH WITH EDGE, TYP.
EXISTING LIGHTWEIGHT
INSULATING CONCRETE (LWIC)
SUBSTRATE
MODIFIED BITUMEN ROOF
MEMBRANE BASE PLY (SMOOTH),
OVER MECHANICALLY ATTACHED
BASE SHEET, TYP.
3 TYP. EMBEDDED EDGE FLASHING (AREA A)
A302 SCALE: 3"=1'-0"
(ALL ITEMS ARE NEW UNLESS DESIGNATED AS EXISTING)
EXISTING 2-PLY MODIFIED BITUMEN ROOF
MEMBRANE SYSTEM AND MECHANICALLY ATTACHED
BASE SHEET, TO BE REMOVED
EXISTING ROOF SYSTEM
EXISTING TAPERED CELLULAR LIGHTWEIGHT
INSULATING CONCRETE (LWIC), TO REMAIN
· LWC TOPPING AVERAGE 2" THICK
· EPS INSULATION VARIES TYP. 1" TO 8"±
EXISTING MODIFIED BITUMEN ROOF SYSTEM WITH
MECHANICALLY ATTACHED BASE SHEET, TO REMAIN
EXISTING CELLULAR LIGHTWEIGHT CONCRETE,
TO REMAIN
EXISTING CORRUGATED STEEL FORM DECK,
TO REMAIN
PROVIDE SURFACE PRIMERS OR
CONDITIONERS AS REQUIRED BY THE
MANUFACTURER TO PROMOTE ADHESION.
NOTE: FOR FLUID-APPLIED ROOF SURFACE AREAS,
WALKWAYS (OR WALKPATHS) MAY BE PROVIDED
USING AN ADDITIONAL LAYER OF GREY-COLORED
PMMA SURFACING WITH SKID RESISTANT FINISH
MODIFIED BITUMEN ROOF MEMBRANE:
SMOOTH SURFACED BASE PLY MEMBRANE
OVER MECHANICALLY ATTACHED BASE
SHEET (TORCH APPLIED) SEE 1/A301
ALTERNATE (AREA A): AS AN ALTERNATE TO APPLYING A MODIFIED
BITUMEN ROOF SYSTEM WITH PMMA SURFACING, PROVIDE A DEDUCT
COST FOR INSTALLING A 3-PLY MODIFIED BITUMEN ROOF SYSTEM
(2-BASE PLIES WITH 1 GRANULE SURFACED CAP PLY). REFER TO
ALTERNATES, SECTION 012300 AND DETAIL 6/A302.
4 TYP. FLUID-APPLIED ROOF SURFACING SYSTEM (AREA A)
A302 SCALE: NTS
(ALL ITEMS ARE NEW UNLESS DESIGNATED AS EXISTING)
EXISTING MODIFIED BITUMEN ROOFING
SYSTEM WITH GRANULAR SURFACED CAP
SHEET, MAKE REPAIRS THEN CLEAN AND
APPLY CONDITIONER AND/OR PRIMER AS
PRESCRIBED BY THE MANUFACTURER TO
PROMOTE ADHESION
5 TYP. FLUID-APPLIED ROOF COATING SYSTEM (AREA B)
A302 SCALE: NTS
(ALL ITEMS ARE NEW UNLESS DESIGNATED AS EXISTING)
3-PLY MODIFIED BITUMEN ROOF MEMBRANE:
GRANULAR SURFACED CAP SHEET OVER 2-PLIES OF
SMOOTH BASE PLY MEMBRANE(S) (TORCH APPLIED).
MECHANICALLY ATTACHED BASE SHEET
EXISTING TAPERED CELLULAR LIGHTWEIGHT
INSULATING CONCRETE (LWIC)
· LWC TOPPING AVERAGE 2" THICK
· EPS INSULATION VARIES TYP. 1" TO 5"±
EXISTING MODIFIED BITUMEN ROOF SYSTEM WITH
MECHANICALLY ATTACHED BASE SHEET
EXISTING CELLULAR LIGHTWEIGHT CONCRETE
NEW ROOF SYSTEM (ALTERNATE)
EXISTING CORRUGATED STEEL FORM DECK
NOTE: THIS ROOF SYSTEM CROSS SECTIOPN IS PROVIDED AS AN ALTERNATE TO 1/A301, REFER TO SECTION 012300 - ALTERNATES
6 ALTERNATE ROOF SYSTEM (AREA A)
A302 SCALE: 3"=1'-0"
(ALL ITEMS ARE NEW UNLESS DESIGNATED AS EXISTING)
Engineer
Alan S. Craigo, P.E.
ARCH/ENGR OF RECORD
DESIGNED BY
ASC/MST
DRAWN BY
JWN/VL
ISSUE DATE
04/13/2026
AE PROJECT NUMBER
678444
SHEET TITLE
ROOF SYSTEM
INFORMATION
DRAWING NO.
A302