C1DZ--631-25-002 Renovate B2 for Pharmacy SF330 Requests for Qualifications Full and Open

Location: Massachusetts
Posted: Jun 4, 2025
Due: Jun 11, 2025
Agency: VETERANS AFFAIRS, DEPARTMENT OF
Type of Government: Federal
Category:
  • C - Architect and Engineering Services - Construction
Solicitation No: 36C24124R0106
Publication URL: To access bid details, please log in.
Follow
C1DZ--631-25-002 Renovate B2 for Pharmacy SF330 Requests for Qualifications Full and Open
Active
Contract Opportunity
Notice ID
36C24124R0106
Related Notice
36C24124R0106
Department/Ind. Agency
VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier
VETERANS AFFAIRS, DEPARTMENT OF
Office
241-NETWORK CONTRACT OFFICE 01 (36C241)
General Information View Changes
  • Contract Opportunity Type: Special Notice (Updated)
  • Updated Published Date: Jun 04, 2025 11:52 am EDT
  • Original Published Date: Nov 21, 2024 03:38 pm EST
  • Updated Response Date: Jun 11, 2025 01:00 pm EDT
  • Original Response Date: Dec 30, 2024 01:00 pm EST
  • Inactive Policy: Manual
  • Updated Inactive Date: Oct 08, 2025
  • Original Inactive Date: Apr 08, 2025
  • Initiative:
    • None
Classification
  • Original Set Aside:
  • Product Service Code: C1DZ - ARCHITECT AND ENGINEERING- CONSTRUCTION: OTHER HOSPITAL BUILDINGS
  • NAICS Code:
    • 541310 - Architectural Services
  • Place of Performance:
    Leeds , MA 01053
    USA
Description

631-25-002 Renovate Building 2 for Pharmacy RFIs Received Paragraph A. INTRODUCTION on page 1 indicates that the scope to be performed consists of interior spaces, however the design service list on page 3 indicates that Building 2 is part of the Northampton Veterans Administration Hospital Historic District and therefore care must be made with exterior changes to remain close to historical appearances. Please clarify, does scope include exterior improvements or is all work expected to be interior for the Building 2 renovation? VA Response: Some exterior work expected. SOW has following line items regarding exterior: Review and design of building egress pathways (i.e., entry doors, rear doors, ADA ramps, emergency egress stair towers, etc.) Review of exterior walls to improve envelope performance. Repairing the building envelope will be a part of this design as there are known issues with the masonry, windowsills and lintels, and other infrastructure. Replacement of existing windows. Professional Qualifications listed on page 6 state that the design firm must provide a Physical Security team member and resume as part of the submission. Please advise if this a low-voltage security designer or otherwise. The role of Physical Security is a bit ambiguous. VA Response: Physical Security team member must be familiar with the PSRDM and meet the qualifications in section 1.8 of the manual: In order to meet the physical security and resiliency requirements of this manual, as appropriate to the scope of the project, the design team must include: (1) a certified physical security specialist with an emphasis on risk and vulnerability assessments, physical security design and CPTED, and anti-terrorism force protection; (2) a control systems cybersecurity specialist with in-depth knowledge of the Risk Management Framework; (3) a certified physical security specialist with an emphasis on Electronic Security Systems; (4) certified information and communications technology (ICT) specialist with an emphasis on networking and cabling; (5) a certified systems integrator specialist with an emphasis on HSPD/PPD-21 integrations; and, (6) a licensed professional structural engineer who has specialized training in blast design and analysis (structural blast specialist). These specialists must be part of the design team during the concept phase of any project. The résumé of the specialist must be submitted to the VA Project Manager (PM), local facility equivalent, or Contracting Officer Representative for review and approval prior to the concept phase of the project. The qualifications of the firm for whom the specialist works must also be submitted with the résumé. The professional qualifications that all specialists must comply with PHYSICAL SECURITY & RESILIENCY DESIGN MANUAL October 1, 2020 Revised 05-01-2024 INTRODUCTION 1-23 are found where their respective disciplines are addressed in Chapters 2, 6, 7, and 10 of this manual. Does the VA hire the Fire Protection engineer for the independent fire review or is that a consultant that should be included? VA Response: The VA provides the Fire Protection Engineer for the Independent Fire Review. See section 2.2 which states, [a] complete design including but not limited to determination and evaluation of existing conditions, necessary engineering calculation, necessary design work, independent fire safety/life safety review (Independent Fire Safety Review provided by VA. A/E is required to address comments from this review), IH Services, quantity and cost estimates, bid schedule, construction cost estimates, a proposed construction schedule, design analyses and calculations, a design documentation report, engineering considerations and options report shall be developed for this project.Â


Attachments/Links
Contact Information
Contracting Office Address
  • ONE VA CENTER
  • TOGUS , ME 04330
  • USA
Primary Point of Contact
Secondary Point of Contact


History

Related Document

Nov 21, 2024[Special Notice (Original)] C1DZ--631-25-002 A/E Design Renovate Building 2 for Pharmacy SF330 Request for Qualifications
Nov 22, 2024[Special Notice (Updated)] C1DZ--631-25-002 A/E Design Renovate Building 2 for Pharmacy SF330 Request for Qualifications
Dec 18, 2024[Special Notice (Updated)] C1DZ--631-25-002 Renovate B2 for Pharmacy SF330 Requests for Qualifications Responses to RFIs Received
Dec 23, 2024[Special Notice (Updated)] C1DZ--631-25-002 Renovate B2 for Pharmacy SF330 Requests for Qualifications Responses to RFIs Received.
May 15, 2025[Sources Sought (Updated)] C1DZ--A/E Design 631-25-002 Renovate B2 for Pharmacy
May 16, 2025[Special Notice (Updated)] C1DZ--631-25-002 Renovate B2 for Pharmacy SF330 Requests for Qualifications Full and Open
May 16, 2025[Sources Sought (Updated)] C1DZ--A/E Design 631-25-002 Renovate B2 for Pharmacy
May 16, 2025[Special Notice (Updated)] C1DZ--631-25-002 Renovate B2 for Pharmacy SF330 Requests for Qualifications Responses to RFIs Received.
Sep 16, 2025[Award Notice (Original)] C1DZ--A/E Design 631-25-002 Renovate B2 for Pharmacy
Daily notification on new contract opportunities

With GovernmentContracts, you can:

  • Find more opportunities and win more business
  • Receive daily alerts for all new bid opportunities
  • Get contract opportunities matched to your business
ONE WEEK FREE TRIAL

See also

Follow CGC WILLIAM SPARLING DD REPAIRS FY27 Active Contract Opportunity Notice ID 70Z08027QWSPARLING

HOMELAND SECURITY, DEPARTMENT OF

Bid Due: 6/03/2026

Bid Number: 26120 Bid Title: 26120 Public Health Shared Services Health Inspector Consultant

City of Gloucester

Bid Due: 6/10/2026

Header Information Bid Number: BD-26-2009-CODC-CODCD-129712 Description: #2 Heating Fuel Bid Dukes County Bid

Commonwealth of Massachusetts

Bid Due: 6/11/2026

Header Information Bid Number: BD-26-1166-COS01-COS01-129689 Description: RFP 26-68 Teen Programs Bid Opening Date:

Commonwealth of Massachusetts

Bid Due: 6/03/2026

* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.