H345--Water Storage Tank Cleaning
Active
Contract Opportunity
Notice ID
36C24826Q0172
Related Notice
Department/Ind. Agency
VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier
VETERANS AFFAIRS, DEPARTMENT OF
Office
248-NETWORK CONTRACT OFFICE 8 (36C248)
Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information View Changes
  • Contract Opportunity Type: Combined Synopsis/Solicitation (Updated)
  • Updated Published Date: Mar 25, 2026 01:06 pm EDT
  • Original Published Date: Mar 06, 2026 02:29 pm EST
  • Updated Date Offers Due: Apr 01, 2026 12:30 pm EDT
  • Original Date Offers Due: Mar 20, 2026 04:00 pm EDT
  • Inactive Policy: Manual
  • Updated Inactive Date: May 31, 2026
  • Original Inactive Date: May 19, 2026
  • Initiative:
    • None
Classification View Changes
  • Original Set Aside: Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
  • Product Service Code: H345 - INSPECTION- PLUMBING, HEATING, AND WASTE DISPOSAL EQUIPMENT
  • NAICS Code:
    • 238220 - Plumbing, Heating, and Air-Conditioning Contractors
  • Place of Performance:
    Department of Veterans Affairs Network Contracting Office 8 (NCO 8) Bay Pines , 33744
Description View Changes
AMENDMENT 0002 to Combined Synopsis # 36C248-26-Q-0172
Department of Veterans Affairs
Network Contracting Office 8 (NCO 8)
10,000 Bay Pines Blvd, Bay Pines, FL 33744

The purpose of Amendment 0002 is to:
1. Extend the RFQ closing date, and answer questions.
Attachment A Answers to RFQ Questions

1. RFQ Closing Date Extension
The RFQ closing date is hereby extended from: March 25, 2026
to the new closing date of: April 1, 2026 @ 12:30PM EST
All quotations must be received by the new closing date and submitted in accordance with the original solicitation instructions.

2. Added Attachments
The following documents are hereby incorporated into the solicitation and made part of Combined Synopsis/Solicitation # 36C248-26-Q-0172:

Attachment A Answers to RFQ Questions
Offerors shall review all attachments and ensure their quotations reflect the information included in these documents.

3. All Other Terms and Conditions
Except as specifically stated herein, all other terms, conditions, and provisions of the original Combined Synopsis/Solicitation remain unchanged and in full force and effect.





Attachment A Answers to RFQ Questions
Please quantify the amount of sediment removal that s needed. How many inches of sediment should be assumed as a minimum for the base bid. This will allow proper estimation of solids cleaning, hauling and processing. Tank 1 has been empty and offline for about 24 months. It could be inspected. Tank 2 is full and has been online for about 24 months. It cannot be taken offline until tank 1 is fully clean, sanitized and inspected.

Please indicate how lines are to be isolated in order to replace valves? The shut off valve for the tank is an underground valve that a VHA staff will open/close.

Please clarify the exact location for electrical supply. We will require a continuous supply of electricity during the period of work: one 100-AMP, 110/220-volt service for the operation of our power tools and accessories, located not more than 100 feet from each tank/structure. Please clarify that all circuit breakers are ground-fault protected. It was not stated in the statement of work, but electrical power will not be provided. Vendors must supply their own power via generators.

Please clarify the exact location of a water source on/near the filter basins within 100ft. We require 60gpm off low at 50 psi to complete our work for this project. There is a hose bib in the pump house building right next to the tanks. Standard size hose bib that has about 75 psi. If not sufficient for flow, there is a hydrant that can be connected to that is 280 feet from the center of the tanks.

Previous or similar projects have required the prime contractor to self-perform a minimum of 50% of the work. Can you confirm if there are any requirements regarding the percentage of self-performed work by the prime contractor for this contract? The prime contractor must self-perform at least 50% of personnel costs. Work subcontracted to similarly situated small businesses counts towards this limit.

Are there any pressure testing requirements for the pipe or valve following installation? Just that the connection points (flanges) do not leak under city water pressure.

Are there any start-up or adjustment requirements for the new valves following installation? No, Bay Pines staff will take care of this.
Is the entirety of tank walls and underneath the ceiling required with the tank floor or just 8' up the walls from the floor bottom and the tank floor? All surfaces of the tank need to be cleaned and sanitized. Including roof.
Is the tank floor for both tanks flat, concave or convex?  See Drawings.
What is the size (diameter) for the manways on the top of each tank? See Drawings.
Will the VA provide a water source onsite in close proximity to the 2 tanks? There is a water spigot in the pump house right next to tanks. If not enough supply / volume there is a hydrant about 250 feet from the tanks.
What is the estimated time frame for the VA to empty the 2nd tank once the first tank was cleaned? Within 48 hours.
Can equipment be staged onsite during the duration of the project? Yes.
Will the VA have bathroom accommodation that can be used during the project or are portlets required. Portlets will be required.
Would the VA consider using commercial divers to clean and inspect these tanks without dewatering in accordance with AWWA M42 (page 129)? No.
Will there be another site visit? No.
Attachments/Links
Contact Information View Changes
Contracting Office Address
  • 8875 HIDDEN RIVER PARKWAY
  • TAMPA , FL 33637
  • USA
Primary Point of Contact
Secondary Point of Contact


History

Related Document

Mar 6, 2026[Combined Synopsis/Solicitation (Original)] H345--Water Storage Tank Cleaning
Mar 20, 2026[Combined Synopsis/Solicitation (Updated)] H345--Water Storage Tank Cleaning
Daily notification on new contract opportunities

With GovernmentContracts, you can:

  • Find more opportunities and win more business
  • Receive daily alerts for all new bid opportunities
  • Get contract opportunities matched to your business
ONE WEEK FREE TRIAL

See also

Follow High Speed Aerial Targets Active Contract Opportunity Notice ID W900KK-26-SSN-Targets Related Notice

DEPT OF DEFENSE

Bid Due: 6/29/2026

Follow 47--COUPLING HALF,QUICK Active Contract Opportunity Notice ID SPE7M326T6274 Related Notice Department/Ind. Agency

DEPT OF DEFENSE

Bid Due: 6/08/2026

Follow 59--REACTOR Active Contract Opportunity Notice ID SPE4A626T73P2 Related Notice Department/Ind. Agency DEPT

DEPT OF DEFENSE

Bid Due: 6/05/2026

Follow 53--COVER,ACCESS Active Contract Opportunity Notice ID SPE7L126Q1138 Related Notice Department/Ind. Agency DEPT

DEPT OF DEFENSE

Bid Due: 6/08/2026

* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.