Dual Channel Transmitters and Two Flow Transducers, NO SUBSTITUTIONS

Location: New York
Posted: Apr 15, 2025
Due: May 5, 2025
Agency: ENERGY, DEPARTMENT OF
Type of Government: Federal
Category:
  • M - Operation of Government Owned Facilities
Solicitation No: 458388
Publication URL: To access bid details, please log in.
Follow
Dual Channel Transmitters and Two Flow Transducers, NO SUBSTITUTIONS
Active
Contract Opportunity
Notice ID
458388
Related Notice
Department/Ind. Agency
ENERGY, DEPARTMENT OF
Sub-tier
ENERGY, DEPARTMENT OF
Office
BROOKHAVEN NATL LAB -DOE CONTRACTOR
Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information
  • Contract Opportunity Type: Combined Synopsis/Solicitation (Original)
  • Original Published Date: Apr 14, 2025 09:09 pm EDT
  • Original Date Offers Due: May 05, 2025 05:00 pm EDT
  • Inactive Policy: 15 days after date offers due
  • Original Inactive Date: May 20, 2025
  • Initiative:
    • None
Classification
  • Original Set Aside:
  • Product Service Code: M1HA - OPERATION OF GOVERNMENT-OWNED CONTRACTOR-OPERATED (GOCO) R&D FACILITIES
  • NAICS Code:
    • 334513 - Instruments and Related Products Manufacturing for Measuring, Displaying, and Controlling Industrial Process Variables
  • Place of Performance:
    Upton , NY 11973
    USA
Description

Kindly quote this “FFP” (Firm Fixed Price) requirement with a Quote in my name, Current Date and Lead Time. Please offer BSA any discounts available for your Best Price.



Items to be quoted (NO SUBSTITUTIONS):



Qty 1 DE7-F721WD-NNNNN-2AL2-NN.CS4.MO3 / FLUXUS F721WD Dual Channel Transmitter & Two Flow Transducers



Combinations Application FLUXUS F721WD Dual Channel [F] FLUXUS for the measurement of: liquids [721] Type: 721 [WD] Water distribution [NN] No explosion protection [N] Non-intrinsically safe [NN] No additional certificate [2] Measuring channels: 2 [AL] Housing: aluminum, metric [2] Power supply: 20...32 V DC [NN] No communication module Outputs [CS4] 4 x current output, switchable, active/passive, 4...20 mA [MO3] 3 x digital output (optorelay) status, pulse, frequency 0...5 kHz Quantity: 2 Part #: TRD-FSQ-NNNN-NNT1-003 Transducer calibration with aperture calibration 6 measuring points, including calibration certificate (factory calibration, no accredited report) [F] For the measurement of: liquids [S] Typ: Shear wave [Q] Transducer frequency Q – 4 MHz Inner pipe diameter (recommended): 0.98…5.9 in inner pipe diameter (extended): 0.39…9.4 in [N] Temperature range: -40…+266 °F [NN] No explosion protection [NN] No additional certificate [T1] Connection system:stripped cable ends [003] Cable length: 9 f Quantity: 2 Part #: MOU-VCQ-DM-SSSK2 [VC] Variofix C For transducer frequency Q – 4 MHz [D] Measurement arrangement: diagonal or reflection [M] Inner rail length: 9.80 in [S] Fixation: tension straps [SSK2] 3" - 6"



Qty 1 DE7-F721WD-NNNNN-1AL2-NN.CS2.MO2 / FLUXUS F721WD Dual Channel Transmitter & Two Flow Transducers



Combinations Application FLUXUS 721WD [F] FLUXUS for the measurement of: liquids [721] Type: 721 [WD] Water distribution [NN] No explosion protection [N] Non-intrinsically safe [NN] No additional certificate [1] Measuring channels: 1 [AL] Housing: aluminum, metric [2] Power supply: 20...32 V DC [NN] No communication module Outputs [CS2] 2 x current output, switchable, active/passive, 4...20 mA [MO2] 2 x digital output (optorelay) status, pulse, frequency 0...5 kHz Clamp-On Transducer TRD-FSP-NNNN-NNT1-004 CDP2N53 Transducer calibration with aperture calibration 6 measuring points, including calibration certificate (factory calibration, no accredited report) [F] For the measurement of: liquids [S] Typ: Shear wave [P] Transducer frequency P – 2 MHz Inner pipe diameter (recommended): 2.0…15.7 in inner pipe diameter (extended): 0.98…18.9 in [N] Temperature range: -40…+266 °F [NN] No explosion protection [NN] No additional certificate [T1] Connection system:stripped cable ends [004] Cable length: 13 ft MOU-VCP-DM-SSSK2 [VC] Variofix C For transducer frequency P – 2 MHz [D] Measurement arrangement: diagonal or reflection [M] Inner rail length: 15.70 in [S] Fixation: tension straps [SSK2] 3" - 6"



Qty 1 Flexim Service (Startup and Consulting). 1.5 Day Rate for local Flexim Service - Startup and Commissioning





QA Paragraph(S): 3.1.3 (See attached QA 101 for details)



Freight along with any Packing & Handling fees are to be included in the all-inclusive price of the item delivered to BNL. *The BNL PO will NOT have a line for freight or extra fees.





Please provide the following on your quote:



1. Origin of Manufacture and Origin of Shipment



2. Unique Entity Identifier (UEI)





Please also return the following along with your quote:



1. Published Price list: showing the items on your quote for price justification or a web screenshot (or link) of same/similar items with pricing and part number shown.



2. Insurance: **IF APPLICABLE** Upon award, in accordance with Article 6 of the attached “BSA Supplemental Terms and Conditions for Work by Contractors On Site at Brookhaven National Laboratory”. Prior to coming on site to perform work, the certificate must remain in effect for the duration of the subject contract and must be filed with BNL Procurement & Property Management Division.



Please Note: As Required by the Work on Site Terms – reference Article 6 - *Naming Brookhaven Science Associates and the US Government as additional insured along with all other requirements



3. System For Award Management (SAM):



In order to support DOE reporting requirements, BSA requires all its vendors/contractors to be registered in the U. S. Government supplier database entitled System For Award Management (SAM) with their Unique Entity ID number (UEI#). Registration can be performed on line at www.sam.gov. If not already registered, please register as soon as possible since failure to do so may preclude BSA from doing business with your organization. Please note that there is no charge for SAM registration. When registering, you are strongly urged to copy and paste www.sam.gov onto your browser address rather than utilizing your search engine. Utilizing your search engine may redirect you to an erroneous site. You may obtain assistance in completing your registration by contacting the Federal Help Desk at 866-606-8220 or by contacting your local Procurement Technical Assistance Center (PTAC), which can be found at https://www.aptac-us.org



4. Basis of Award:



BSA will make award to the responsive and responsible offeror who submits the lowest total price and who meets all of BSA’s technical requirements, as stated herein.



5. Pricing: shall remain valid for 60 days





Quotations will be opened in private. Quotations, including their withdrawal or modification, received after the closing date shall be considered late. Such responses will only be considered for award if it is in BSA’s best interest to do so.



Any resulting purchase order will be subject to the attached Terms and Conditions.


Attachments/Links
Contact Information
Contracting Office Address
  • P.O. Box 5000
  • Upton , NY 11973
  • USA
Primary Point of Contact
Secondary Point of Contact


History
  • Apr 14, 2025 09:09 pm EDTCombined Synopsis/Solicitation (Original)
Daily notification on new contract opportunities

With GovernmentContracts, you can:

  • Find more opportunities and win more business
  • Receive daily alerts for all new bid opportunities
  • Get contract opportunities matched to your business
ONE WEEK FREE TRIAL

See also

...23 Title: 3 West biplane Refresh Commissioning CR#: 2135504 Agency: State University of ...

The New York State Contract Reporter

Bid Due: 6/16/2026

...and commissioning. Additionally, all necessary utility interconnections to bring fuel to the power ...

DEPT OF DEFENSE

Bid Due: 6/24/2026

...facilities include paving, walks, curbs, gutters, and utilities testing and commissioning. This project...

DEPT OF DEFENSE

Bid Due: 6/12/2026

..., installation, commissioning and maintenance of an Audio system for their boardroom. Qualified...

Wyoming County

Bid Due: 6/19/2026

* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.