USCGC ALDER CLEAN AND INSPECTION OF R-102 GALLEY FIRE SS
| Location: |
California |
| Posted: |
Mar 30, 2026 |
| Due: |
Apr 7, 2026 |
| Agency: |
HOMELAND SECURITY, DEPARTMENT OF |
| Type of Government: |
Federal |
| Category: |
- J - Maintenance, Repair, and Rebuilding of Equipment
|
| Solicitation No: |
70Z08536Q023738 |
| Publication URL: |
To access bid details, please log in. |
USCGC ALDER CLEAN AND INSPECTION OF R-102 GALLEY FIRE SS
Active
Contract Opportunity
Notice ID
70Z08536Q023738
Department/Ind. Agency
HOMELAND SECURITY, DEPARTMENT OF
Sub-tier
US COAST GUARD
Office
SFLC PROCUREMENT BRANCH 2(00085)
Looking for contract opportunity help?
General Information
-
Contract Opportunity Type: Solicitation (Original)
-
Original Published Date: Mar 30, 2026 05:18 pm EDT
-
Original Date Offers Due: Apr 07, 2026 08:00 am EDT
-
Inactive Policy: 15 days after date offers due
-
Original Inactive Date:
Apr 22, 2026
-
Initiative:
Classification
-
Original Set Aside: Total Small Business Set-Aside (FAR 19.5)
-
Product Service Code: J020 - MAINT/REPAIR/REBUILD OF EQUIPMENT- SHIP AND MARINE EQUIPMENT
-
NAICS Code:
-
336611 - Ship Building and Repairing
-
Place of Performance:
San Francisco
,
CA
94130
USA
Description
TECHNICAL SERVICES FOR CLEAN AND INSPECTION OF R-102 GALLEY FIRE SUPPRESSION SYSTEM
USCGC ALDER
-
Background. This requirement is for the contractor to clean the galley hood and inspection of R-102 Galley Fire Suppression System.
-
Scope. The Contractor shall provide all personnel including services, labor, materials, travel, parts, tools, test equipment, test fittings, supplies, consumables, and equipment to accomplish tasking. The Contractor shall provide the services of a qualified Tech Rep, who is familiar with the R-102 Galley Fire Suppression System system/equipment, to accomplish all tasking. The Tech Rep will be responsible for the following:
-
Advise on manufacturer's proprietary information pertinent to the system.
-
Assist with proper repair methods and ensure compliance with manufacturer's procedures and standards during disassembly, inspection, repair, modification, calibration, and reassembly of the equipment/system.
-
Ensure compliance with manufacturer's procedures and standards during disassembly, inspection, and reassembly of the system.
-
Exhaust Hood: The interior and exterior surfaces of the hood will be cleaned to bare metal. This includes the plenum, the area behind the filters.
-
Grease Filters: Filters will be removed, cleaned, and reinstalled. Damaged or worn filters should be reported to the client for replacement.
-
Ductwork: All accessible ductwork, both horizontal and vertical, will be cleaned to remove all grease buildup.
-
Condensate Drains: All condensate drains and collection points will be cleared of obstructions and cleaned to ensure proper drainage.
-
Objective. The objective of this requirement is to complete annual maintenance on the system
-
Tasks. The contractor shall provide labor and maintenance services IAW TP 3924-555-A, R-102 Restaurant Fire Suppression System, TP 4563B-555-A, Fire Suppression System-Model R-102, TP 7427-651-A, R-102 Restaurant Fire Suppression System, TP 8057-555-A, Range Hood Fire Fighting System R-102-1T-4N-6F, to include but not limited to:
4.1. Clean
4.2. Inspect
4.3 Service
4.4 Repair
4.5 Certified
-
Delivery. Contractor shall provide a final report within 3 days of contract period of performance.
-
Government furnished property. None. Contractor will provide tools, expendables, and consumables.
-
Security Requirement. Base access is required. Vendor shall have a valid driver’s license and show identification. A CG representative from the cutter will sponsor and escort vendor to the cutter.
-
Place of performance- USCGC ALDER 1 Yerba Buena Island San Francisco, CA 94130
-
Period of performance- April 19 to May 17 2026
-
Points of Contact.
10.1. USCG-SFLC-IBCTPLAPM2: CWO Keith Hoefer, Keith.A.Hoefer@uscg.mil, (571) 608-9238
10.2. USCGC ALDER: CWO Chrisopher Laterza, Christopher.P.Laterza@uscg.mil (415) 399-3590
See also attachment.
Attachments/Links
Contact Information
Contracting Office Address
-
COAST GUARD ISLAND, BLDG 50-7
-
ALAMEDA , CA 94501
-
USA
Secondary Point of Contact
History
-
Mar 30, 2026 05:18 pm EDTSolicitation (Original)
Daily notification on new contract opportunities
With GovernmentContracts, you can:
- Find more opportunities and win more business
- Receive daily alerts for all new bid opportunities
- Get contract opportunities matched to your business
ONE WEEK FREE TRIAL
See also
...fighting equipment 25111602 Safety & rescue water craft - Fire fighting watercraft 25201901 ...
State Government of California
Bid Due: 6/10/2026
...prevention 46191600 Fire protection - Fire fighting equipment 72151700 Special trade construction &... ...
State Government of California
Bid Due: 6/03/2026
...UNSPSC Classification Description 46191602 Fire protection - Fire fighting equipment - Fire... IFB ...
State Government of California
Bid Due: 6/03/2026
.../REPAIR/REBUILD OF EQUIP- FIRE FIGHTING/RESCUE/SAFETY EQUIP; ENVIRON PROTECT EQUIP/MATLS NAICS Code...
DEPT OF DEFENSE
Bid Due: 6/03/2026
* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.