| Location: | Rhode Island |
|---|---|
| Posted: | Oct 6, 2025 |
| Due: | Oct 7, 2025 |
| Agency: | DEPT OF DEFENSE |
| Type of Government: | Federal |
| Category: |
|
| Solicitation No: | N6660426Q0022 |
| Publication URL: | To access bid details, please log in. |
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
Please see attached RFQ for all details about this opportunity.
AMENDMENT 0001: 10/02/2025
Solicitation amended to answer industry questions.
QUESTION:
We need to know the INLET pressure of the compressed air. We can mount a pressure regulator so you can control it to your required pressure; Outlet Pressure Range: 5–15 PSIG.
ANSWER: The units produce the pressure, there is not a specification for an inlet pressure. We need a minimum output of 15PSI with 4 ports.
QUESTION:
Is there a technical contact / requestor I could communicate with to better understand the application?
ANSWER:
All questions may be send to maria.d.diaz-sotomayor.civ@us.navy.mil
QUESTION:
Is there a specific process to submit these (quotes)?
ANSWER:
Quotes shall be submitted via email to maria.d.diaz-sotomayor.civ@us.navy.mil
AMENDMENT 0002: 10/06/2025
Solicitation amended to answer industry questions.
QUESTION:
The greatly varying Output capacity, listed as 350-550 SCFD. Usually capacities for compressed air are listed as CFM or SCFM, so I do not know if this was a typo or not. Also, if the spec is for SCFM, the capacity figures of 350-550 SFCM covers 3 different size models.
ANSWER:
Normal 350 SCFD, or 0.24 SCFM.
QUESTION:
What is the dewpoint requirement? -40 or -100F
ANSWER:
No dewpoint requirement, so either is acceptable.
QUESTION:
What is the Hz on the electrical 50 or 60hz?
ANSWER:
60 Hz