4610--WATER PURIFICATION SYSTEM HAMPTON VAMC/DIALYSIS

Location: Federal
Posted: Feb 9, 2026
Due: Feb 17, 2026
Agency: VETERANS AFFAIRS, DEPARTMENT OF
Type of Government: Federal
Category:
  • 46 - Water Purification and Sewage Treatment Equipment
Solicitation No: 36C24626Q0335
Publication URL: To access bid details, please log in.
Follow
4610--WATER PURIFICATION SYSTEM HAMPTON VAMC/DIALYSIS
Active
Contract Opportunity
Notice ID
36C24626Q0335
Related Notice
Department/Ind. Agency
VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier
VETERANS AFFAIRS, DEPARTMENT OF
Office
246-NETWORK CONTRACTING OFFICE 6 (36C246)
Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information
  • Contract Opportunity Type: Sources Sought (Original)
  • Original Published Date: Feb 09, 2026 10:00 am EST
  • Original Response Date: Feb 17, 2026 10:00 am EST
  • Inactive Policy: Manual
  • Original Inactive Date: Mar 19, 2026
  • Initiative:
    • None
Classification
  • Original Set Aside:
  • Product Service Code: 4610 - WATER PURIFICATION EQUIPMENT
  • NAICS Code:
    • 333310 - Commercial and Service Industry Machinery Manufacturing
  • Place of Performance:
    ,
Description
VAMC Hampton is looking for a Water Purification system with the following:
- Salient Characteristics
- Water Purification System that can produce not less than 200 liters of water per hour, fitted with deionization capabilities
- MODEL MEDICA-R 200
- Make-up rate 15C 200 l/hr
- Delivery flow rate maximum115V, 60Hz 21 l/min @ 45psi (3bar) Inorganics (resistivity @25°C) >10 M -cm (1)
- Organics (TOC) - typical - Particles 0.2 m filter Silica - Notes: 1 with Ion-exchange cylinder installed (Nuclear or Hypex grade resin), 2 subject to correct operating and maintenance procedures
- Feedwater Requirement:
- Source: Tap water as detailed below Conductivity: - Contaminant:
- Measure: Range: Pretreatment:
- Calcium: Ca ppm as CaCO3 - >250 Softener or use very low RO recovery3
- Free chlorine: Cl2ppm - 0.1 0.5 20 inch carbon block
- >0.5 Cylinder of carbon sized correctly to obtain - Chloramine: Cl2 ppm - 0.1 0.5 20 inch high efficiency carbon (5)
- >0.5 Cylinder of carbon sized correctly to obtain - Silica: SiO2 ppm - >30 20 inch cartridge depth filter or use very low RO recovery (4)
- Fouling index: FI - 10 to 20 20 inch cartridge depth filter
- >20 Back washable media filter with a minimum flow rate of 20 l/min
- Iron/manganese: Fe/Mn ppm - >0.05 20 inch cartridge depth filter (5)
- >0.1 Back-washable Fe filter (6)
- Organics: TOC ppm C - 2 to 3 20 inch carbon block (4)
- >3 Carbon sized Cylinder correctly for TOC demand (4) Temperature: 4 - 40°C (Recommended 15 - 25°C)
-- Flowrate: (requirement at 15°C) 20 l/min
- Drain requirements: (gravity fall with air gap) 45 l/min
- Feedwater pressure: 60psi (4bar) maximum, 30psi (2bar) minimum
- Notes: 3) Check LSI, increase frequency of acid cleaning, 4) Increase frequency of alkaline cleaning,
- 5) Please use ELGA Part Numbers LA683 (Filter Housing) and LC172 (Carbon Filter), 6) Increase frequency of acid cleaning Wall mount canister filter will need (Wall backing required)
- Must include Installation, Commissioning, Training
- Electrical Requirements Mains Input: 115V, 60Hz
- System control voltage (not including pumps and UV) 24V dc Power consumption (peak demand): 2000VA
- Electrical protection rating 20 amps Noise level during recirculation - ***Note: System requires approximately 4' x 6' of floor space for tanks, filtration Unit, and filters.
- -The floor drain must be a minimum of 3" and meet all applicable building codes and system requirements
- -Actual Unit measurement 32" Wide x35"Deep x72"High
Attachments/Links
Contact Information
Contracting Office Address
  • 100 EMANCIPATION DR
  • HAMPTON , VA 23667
  • USA
Primary Point of Contact
Secondary Point of Contact


History
  • Feb 09, 2026 10:00 am ESTSources Sought (Original)

Related Document

Mar 18, 2026[Sources Sought (Updated)] 4610--WATER PURIFICATION SYSTEM HAMPTON VAMC/DIALYSIS
Daily notification on new contract opportunities

With GovernmentContracts, you can:

  • Find more opportunities and win more business
  • Receive daily alerts for all new bid opportunities
  • Get contract opportunities matched to your business
ONE WEEK FREE TRIAL

See also

...clean surfaces by running high voltages (but low currents) through electrodes on the ...

NATIONAL AERONAUTICS AND SPACE ADMINISTRATION

Bid Due: 3/02/2027

...) solar system with low voltage switchgear for building energy shifting; a 750kWh ...

DEPT OF DEFENSE

Bid Due: 6/29/2026

...with low voltage switchgear for building energy shifting; a 750kWh battery energy storage ...

DEPT OF DEFENSE

Bid Due: 6/29/2026

...) solar system with low voltage switchgear for building energy shifting; a 750kWh ...

DEPT OF DEFENSE

Bid Due: 6/29/2026

* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.