Two (2) Endoscope Sterilizers and Reprocessor Units

Location: Florida
Posted: May 15, 2026
Due: May 29, 2026
Agency: DEPT OF DEFENSE
Type of Government: Federal
Category:
  • 65 - Medical, Dental, and Veterinary Equipment and Supplies
Solicitation No: HT940626QE044
Publication URL: To access bid details, please log in.
Follow
Two (2) Endoscope Sterilizers and Reprocessor Units
Active
Contract Opportunity
Notice ID
HT940626QE044
Related Notice
Department/Ind. Agency
DEPT OF DEFENSE
Sub-tier
DEFENSE HEALTH AGENCY (DHA)
Office
DEFENSE HEALTH AGENCY
Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information View Changes
  • Contract Opportunity Type: Sources Sought (Updated)
  • Updated Published Date: May 15, 2026 01:58 pm EDT
  • Original Published Date: May 15, 2026 01:57 pm EDT
  • Updated Response Date: May 29, 2026 03:00 pm EDT
  • Original Response Date: May 29, 2026 03:00 pm EDT
  • Inactive Policy: 15 days after response date
  • Updated Inactive Date: Jun 13, 2026
  • Original Inactive Date: Jun 13, 2026
  • Initiative:
    • None
Classification
  • Original Set Aside: No Set aside used
  • Product Service Code: 6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES
  • NAICS Code:
    • 339112 - Surgical and Medical Instrument Manufacturing
  • Place of Performance:
    Jacksonville , FL 32214
    USA
Description

SERVICE/SUBJECT



The purpose of this RFI is to seek information from the industry on its ability to provide for the acquisition, delivery and installation of two (2) Endoscope Sterilizers and Reprocessors units under NAICS Code 339112 – Surgical and medical Instrument Manufacturing. With this RFI, the Government seeks input as to whether any companies are capable of providing endoscope sterilizers along with the delivery, installation, annual/routine maintenance and training as outlined in the PWS attached.



THIS IS NOT A REQUEST FOR PROPOSALS (RFP) OR A REQUEST FOR QUOTATION (RFQ). IT IS STRICTLY A REQUEST FOR INFORMATION (RFI). NEITHER UNSOLICITED PROPOSALS NOR ANY OTHER KINDS OF OFFERS WILL BE CONSIDERED IN RESPONSE TO THIS RFI. NO CONTRACT WILL BE AWARDED PURSUANT TO THIS ANNOUNCEMENT.



A. DISCLAIMER



IN ACCORDANCE WITH FAR 10.001 AND FAR 6.104-1, THIS RFI IS ISSUED SOLELY FOR MARKET RESEARCH TO GATHER INFORMATION AND ASSESS MARKET CAPABILITIES FOR PLANNING PURPOSES. THIS RFI DOES NOT CONSTITUTE A SOLICITATION. RESPONSES TO THIS NOTICE ARE NOT OFFERS AND CANNOT BE ACCEPTED BY THE GOVERNMENT TO FORM A BINDING CONTRACT. ALL INFORMATION RECEIVED IN RESPONSE TO THIS RFI THAT IS MARKED PROPRIETARY WILL BE HANDLED ACCORDINGLY. RESPONSES TO THE RFI WILL NOT BE RETURNED. AT THIS TIME, QUESTIONS CONCERNING THE COMPOSITION AND REQUIREMENTS FOR FUTURE RFPs WILL NOT BE CONSIDERED. THE GOVERNMENT WILL NOT PAY FOR INFORMATION RECEIVED.



1.0 Purpose



The Defense Health Agency Contracting Activity (DHACA), Healthcare Contracting Division – Southeast (HCD-Southeast), Fort Detrick, Maryland, on behalf of the Naval Hospital Jacksonville (NHJAX), Florida, is conducting market research to determine the capabilities of vendors, who have the capability to provide delivery, installation and maintenance on two Endoscope Sterilizers and Reprocessor units.



2.0 Background



The mission at NHJAX is to provide health protection through readiness, operational support, health promotion, and quality family-centered care to all those entrusted to us. NHJAX is recognized as a center of excellence for ambulatory care, critical care, and women’s health. The NHJAX is seeking information from qualified vendors regarding their capabilities to provide delivery, installation, and maintenance on two (2) Endoscopic Sterilizers and Reprocessor Units for the Naval Hospital Jacksonville (NHJAX), Florida. The two (2) existing endoscope sterilizers and reprocessor units reached the end-of-life expectancy in 2019. Two (2) new endoscope sterilizers and reprocessor units are required to maintain operations at NHJAX.



3.0 Scope/Objectives



The contractor shall supply, deliver and install 2 new endoscope sterilizers/reprocessor units, and provide maintenance and annual training to facility staff at NHJAX. The contractor shall maintain equipment within the original equipment manufacturer’s (OEM) specifications, in accordance with the newest US, State, and Local law and regulations. The contractor shall be responsible for the de-installation of the existing 2 sterilizer/reprocessor units on the same day of installation of the new sterilizer/reprocessor units. The contractor shall disconnect the 2 existing sterilizers and move both to the designated area prior to installing the new sterilizers. Within 2 weeks prior to installation, the contractor shall inspect the existing room to ensure electrical compliance is verified by both the clinic facility manager and clinic safety manager. The room shall meet current equipment manufacturer's (OEM) specifications, in accordance with the newest United States, Florida, and DHA regulations. The contractor shall successfully complete final testing and calibration certification upon completion of installation of the sterilizer/reprocessor units. The contractor must maintain a clean work environment. The contractor shall be responsible for repairs for any damages that occurs during the installation to include floors, paint, walls, and ceiling. Installation includes replacing the two (2) current 2-filter water filtration systems with a new 3-filter water filtration system. Installation of the 2 new endoscope sterilizer/reprocessor units shall be completed with minimal modification to the facility. All modifications to the site are at the Contractor’s cost with no additional cost to the Government. The contractor shall have ownership of any electrical and water installation, to include successful connection of sterilizers and completion of final testing and calibration. NHJAX will coordinate with contractor installation date and time, but installation shall be completed within 3 weeks of contract award. The contractor shall provide labor, materials, travel, personnel supervision, and freight for the scheduled (annual) and unscheduled (routine) maintenance for all equipment. The contractor shall conduct initial in-person general operator training within one (1) week of installation for all designated Endo personnel at NHJAX. The contractor shall be an ORM authorized dealer, authorized distributor, or authorized reseller for the proposed equipment/system such that OEM warrant and services are maintained in accordance with OEM specifications.



The contractor shall provide annual and routine maintenance/support coverage for services and special requests and shall be performed during normal business hours (i.e., 8 hours a day and 5 days a week) , excluding United States Federal Government holidays, which are identified online at the following site: https://www.opm.gov/policy-data-oversight/pay-leave/federal-holidays/#url=2026



Essential Characteristics:




  • The Endoscope sterilizers/reprocessor units shall meet the following specifications:

    • Indicated for use with high-level disinfectant CIDEX OPA Concentrate and an enzymatic detergent (CIDEZYME™ XTRA) to achieve cleaning and high-level disinfection of heat sensitive (>60 degrees C) semi-critical endoscopes.

    • Water pressure must be between 40 PSI and 70 PSI

    • Indicated for use with high-level disinfectant CIDEX OPA Concentrate and an enzymatic detergent (CIDEZYME™ XTRA) to achieve cleaning and high-level disinfection of heat sensitive (>60 degrees C) semi-critical endoscopes.

    • Water pressure must be between 40 PSI and 70 PSI

    • Incoming water temperature must be between 41°F and 86°F

    • Weigh less than 565 lbs when filled

    • Top-loaded so scopes can be properly sterilized

    • Ability to reprocess two endoscopes simultaneously to keep up with patient load in a safe and effective way

    • Includes foot pedals for opening lids

    • Cycle time of 40 minutes or less (must meet AORN standards)

    • Includes all connectors, adaptors, and positioners for processing

    • Includes a built in alcohol flush

    • Includes a self-disinfect cycle to reduce biofilm buildup

    • Includes a lock to prevent operator interaction/exposure with the endoscope while a cycle is in progress

    • Operate properly in an ambient operating temperature and humidity of 64.4 °F to 86 °F (18 °C to 30 °C), and from 10 to 80% relative humidity (non-condensing)

    • Space of at least 0.5 must exist below each housing to allow the filters for the system to be removed and replaced

    • Includes a water filtration system independent of the sterilizer that is capable of filtering contaminants found in municipal water sources (i.e. sediment, soluble organics, and chlorine).






  • Facility Dimensions: 2 Endoscope sterilizers/reprocessor units shall meet the following specifications:

    • Width: 94 cm (37in)

    • Height with lid closed: 116cm (45.5 in)

    • Height with lid open: 150cm (59in)

    • Depth: 75cm (29.5cm)

    • Basin size: 46.35cm (18.25in) W x 50.16cm (19.75in) L x 13.33cm (5.25in) D

    • Installation to occur in SPD on the third floor of Naval Hospital Jacksonville, FL.





4.0 Submission Instructions



Respondents MUST include the following documents/information in your response to the Government:



1. A cover letter on company letterhead including the company name, point of contact (POC) with telephone number, email address, website, as well as company Unique Entity identifier (UEI) and CAGE Code.



2. Is the vendor a small business or other socioeconomic category, and can you meet the NAICS code requirements?



3.Corporate Experience:




  • What is your past performance on similar federal, state, or local projects (provide 2-3 references)?.



4. Technical Capability & Approach:




  • What brand and model of the two (2) Endocope Sterilizers / Reprocessor Units does your company propose will best fit the Government’s need as indicated in the PWS?

  • Confirm your ability to provide delivery and installation within the stated 3 week time period.

  • Confirm required maintenance and training services will be performed by OEM-certified service providers.

  • Confirm your ability to meet the provide support coverage, preventive maintenance, corrective maintenance, and inspections, for service and special requests during normal business hours 0730 and 1600 (EST), Monday through Friday, excluding United States Federal Government holidays

  • Confirm whether proposed sterilizers/reprocessors/water filtration system conform to all of the required specifications for size, electrical, water, etc. as stated within the PWS?

  • What site preparation is required (e.g., water hook ups, electrical work) and how long will it take you to complete the prep work?



5. Staffing & Qualifications:




  • Confirm that your Field Services technicians are OEM-certified service providers.



6. Capabilities statement MUST address the following:




  • Vendor’s clear understanding and ability to perform the ENTIRE scope of this requirement.

  • Vendor’s clear understanding and ability to perform ALL the tasks described within the PWS.

  • Vendor’s confirmation that the company is deemed “responsible” in accordance with FAR 9.104-1.

  • Vendor’s confirmation of current/active registration in SAM.gov.



7. Vendor responses shall be submitted electronically to andrea.l.giuliano.civ@health.mil. The email subject line should read: “Response to RFI No. TBD: 2 Endoscope Sterilizers and Reprocessor Units – YOUR COMPANY NAME” in the subject line.



8. Responses shall be submitted in Adobe PDF or Microsoft Word format and shall not exceed 10 pages. Marketing materials are not requested and will not be reviewed.



Attachments:






  1. Draft Performance Work Statement (PWS) for 2 Endoscope Sterilizers and Reprocessor Units

  2. Room Schematic for Installation


Attachments/Links
Contact Information
Contracting Office Address
  • HCD SOUTHEAST 808 SCHREIDER STREET
  • FREDERICK , MD 21702
  • USA
Primary Point of Contact
Secondary Point of Contact
History
Daily notification on new contract opportunities

With GovernmentContracts, you can:

  • Find more opportunities and win more business
  • Receive daily alerts for all new bid opportunities
  • Get contract opportunities matched to your business
ONE WEEK FREE TRIAL

See also

...Invitation to Bid Florida State Hospital Elevator Maintenance and Repair Department of Children... ...

State Government of Florida

Bid Due: 9/09/2026

...Business (SDVOSB) Set-Aside (FAR 19.14) Product Service Code: 6530 - HOSPITAL FURNITURE, EQUIPMENT... ...

VETERANS AFFAIRS, DEPARTMENT OF

Bid Due: 6/05/2026

...Hospital (NEFSH) issues this Solicitation to select a Respondent(s) to provide for all ...

State Government of Florida

Bid Due: 10/19/2026

...Medical office services 85101504 Psychiatric hospital services 91111904 Assisted living services...

State Government of Florida

Bid Due: 6/30/2028

* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.