6515--Exalt Controller Processor

Location: Virginia
Posted: Jul 14, 2026
Due: Jul 17, 2026
Agency: VETERANS AFFAIRS, DEPARTMENT OF
Type of Government: Federal
Category:
  • 65 - Medical, Dental, and Veterinary Equipment and Supplies
Solicitation No: 36C24526Q0663
Publication URL: To access bid details, please log in.
Follow
6515--Exalt Controller Processor
Active
Contract Opportunity
Notice ID
36C24526Q0663
Related Notice
Department/Ind. Agency
VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier
VETERANS AFFAIRS, DEPARTMENT OF
Office
245-NETWORK CONTRACT OFFICE 5 (36C245)
Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information
  • Contract Opportunity Type: Sources Sought (Original)
  • Original Published Date: Jul 14, 2026 11:04 am EDT
  • Original Response Date: Jul 17, 2026 03:00 pm EDT
  • Inactive Policy: Manual
  • Original Inactive Date: Aug 01, 2026
  • Initiative:
    • None
Classification
  • Original Set Aside:
  • Product Service Code: 6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES
  • NAICS Code:
    • 339112 - Surgical and Medical Instrument Manufacturing
  • Place of Performance:
    Department of Veterans Affairs Baltimore VA Medical Center Baltimore , USA
Description


Page 1 of
Page 1 of
Page 1 of
Page 1 of

This is not a solicitation but rather a Request for Information (RFI/Sources Sought) for market research purposes only. Department of Veterans Affairs, Veterans Health Administration, Network Contracting Office 5, is issuing this Sources Sought in order to identify capable firms and obtain information for planning purposes only.

Responses must be submitted by 3:00 PM EST, July 17th 2026. Submit responses to this Sources Sought via email to james.ferro@va.gov All SDVOSB and VOSB firms that respond shall include proof of SBA certification via https://veterans.certify.sba.gov/All small business firms that respond shall include proof of small business status via their Representations and Certifications in accordance with (FAR 4.1102 Policy). While SDVOSB/VOSB firms are preferred, all capable firms are welcome to respond to this Sources Sought. All respondents to this Sources Sought shall include as part of their response answers to the below questions and provide any additional pertinent information that supports the answers. If there are any ambiguities in this Sources Sought, please identify them in your response.

The results of this market research will assist in the development of (1) the requirement, and (2) the acquisition strategy (e.g., socioeconomic set-aside, full and open competition, etc.). VA assumes no responsibility for any costs incurred associated with the preparation of responses.

Suggested NAICS: 339112 Surgical and Medical Instrument Manufacturing
Suggested PSC: 6515 Medical and Surgical Instruments, Equipment, and Supplies

Open to suggestions from the market as to a more proper NAICS and/or PSC, as well as any potential GSA/FSS Schedule SIN categories.

Product ID#
Product Description
Quantity
M00542430
EXALT Model D Controller
12 Month Lease

Service/Maintenance
1 Year

Statement of Work
Exalt disposable duodenoscope processor for the disposable single use duodenoscope generation 4
Purpose
Replacement of standard Olympus duodenoscope with disposable single use duodenoscope that requires the duodenoscope processor: EXALT Controller
Background
Duodenoscope used in ERCP carry a significant infection risk due to there complex design, particularly the elevator mechanism, which is difficult to clean and disinfect. On December 10, 2018 the U.S. Food & Drug Administration (FDA) released interim results from post-market surveillance studies on contamination rates with duodenoscopes after reprocessing.
FDA has issued a Safety Communication and provided a detailed list of supplemental duodenoscope reprocessing measures that can be implemented to reduce the risk of infection transmission, such as: microbiological culturing, sterilization, use of a liquid chemical sterilant processing system and repeat high-level disinfection. Interim results from these studies indicate higher-than-expected contamination rates after reprocessing, with up to 3% of properly collected samples testing positive for enough low concern organisms to indicate a reprocessing failure, and up to 3% of properly collected samples testing positive for high concern organisms. High concern organisms are defined as organisms that are more often associated with disease, such as E. coli, and Pseudomonas aeruginosa. The FDA recommends facilities and staff strictly adhere to the manufacturer s reprocessing and maintenance instructions, and follow these best practices:
Recent evidence indicates infections rates are substantially higher than previously recognized, with persistent contamination. There has been a sharp increase in global reporting of duodenoscope-related infectious outbreaks, with the majority unrelated to identifiable breaches in disinfection protocols. This has led experts to question the design of the standard duodenoscope. In the Netherlands, a recent nationwide study found that 22% of duodenoscopes were persistently contaminated after high-level disinfection
Exalt single use duodenoscope eliminates the risk of patient of patient infection due to ineffective reprocessing while also eliminates the reprocessing cost. The single use duodenoscope also delivers consistence performance the endoscopist expect from duodenoscope.
Objectives
The objective is to replaced the standard ERCP duodenoscope to disposable duodenoscopes from Boston Scientific which uses a processor for the images called the EXALT Controller.
Product Descriptions
Scope
Specifications
Specification
Value
Retro viewing angle (o)
5
Field of view (o)
108
Depth of field (mm)
5-60
Distal end outer diameter (mm)
15.1
Insertion tube outer diameter (mm)
11.3
Working length (mm)
1240
Working channel inner diameter (mm)
4.2
Angulation range Up (o)
120
Angulation range Down (o)
90
Angulation range Right (o)
110
Angulation range Left (o)
90
Â
Ordering Information
UPN
Item
Description
Packaging
M00542420
EXALT Model D Single-Use Duodenoscope
Sterile Single-Use Duodenoscope for use with EXALT Controller
Box 1
M00542421
EXALT Model D Single-Use Duodenoscope
Sterile Single-Use Duodenoscope for use with EXALT Controller
Box 2
M00542423
EXALT Model D Single-Use Duodenoscope
Sterile Single-Use Duodenoscope for use with EXALT Controller
Box 4
M00542424
EXALT Model D Single-Use Duodenoscope
Sterile Single-Use Duodenoscope for use with EXALT Controller
Box 8
M00542430
EXALT Controller
100-240 VAC Controller for use with single-use duodenoscope (including detachable power cable, DVI and HDMI cables)
Box 1
Period of Performance
Starting as soon as the single use duodenoscope processor EXALT controller is approved.
Place of Performance
Endoscopy unit Baltimore VA

If you are interested, please e-mail the following information:

Company Name:
UEI Number:
Cage Code:
Dun & Bradstreet Number:

Person of Contact (including telephone number and email address).

Socio-economic status (SDVOSB, VOSB, Woman-Owned, Other etc.).

Are you a distributor or a manufacturer?

If you are an authorized distributor, please provide confirmation on Company Letter Head.
If you are a distributor, who is the manufacturer?
Where is the manufacturer located in the world?

Do you currently hold a government contract?

Contract Number?

Type of contract?

Are these particular quoted items under contract?

With whom (GSA, SEWP, etc )?
If GSA what Schedule and SIN?

Can your company provide the service for the listed Department of Veterans Affairs locations?

Page 1 of
Page 1 of
Page 1 of
Page 1 of
Page 1 of
Page 1 of
Page 1 of
Page 1 of

Page 5 of 5
Page 5 of 5
Page 1 of 2
Page 1 of
Page 1 of
Page 1 of
Page 1 of
Does your firm utilize the suggested NAICS and PSC per this Sources Sought Notice? If not, please suggest a more appropriate NAICS and/or PSC and explain why it s more appropriate?

How do you invoice for this service, including rates?

What Certifications, State and/or Federal, if any must you have to perform this service?

Please list all of your concerns, questions and ambiguities below. Questions will not be addressed directly but will be used by the Government in the event that this Sources Sought would move forward to solicitation.

Please provide estimated rates if possible.


Attachments/Links
Contact Information
Contracting Office Address
  • 8849 International Drive Suite 215
  • LINTHICUM , MD 21090
  • USA
Primary Point of Contact
Secondary Point of Contact


History
  • Jul 14, 2026 11:04 am EDTSources Sought (Original)
Daily notification on new contract opportunities

With GovernmentContracts, you can:

  • Find more opportunities and win more business
  • Receive daily alerts for all new bid opportunities
  • Get contract opportunities matched to your business
ONE WEEK FREE TRIAL

See also

...Healthcare Network Status: Open RFP 122350 James City County -James City County Closing ...

State Government of Virginia

Bid Due: 8/03/2026

...Bid Number: 20261035 Bid Title: Healthcare Network Category: Request for Proposals Status: Open... ...

James City County

Bid Due: 8/03/2026

...Follow Incubator Programs for Secure Facilities and Networks at Universities Active Contract... for ...

DEPT OF DEFENSE

Bid Due: 11/12/2026

...Follow Broad Agency Announcement (BAA) for Battery Network (BATTNET) Active Contract Opportunity...

Federal Agency

Bid Due: 9/01/2026

* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.