Y1DZ-- 549-25-178 Replace Condensate Return Units & Pumps at Garland VA

Location: Texas
Posted: Jul 29, 2025
Due: Aug 12, 2025
Agency: VETERANS AFFAIRS, DEPARTMENT OF
Type of Government: Federal
Category:
  • Y - Construction of Structures and Facilities
Solicitation No: 36C25725R0084
Publication URL: To access bid details, please log in.
Follow
Y1DZ-- 549-25-178 Replace Condensate Return Units & Pumps at Garland VA
Active
Contract Opportunity
Notice ID
36C25725R0084
Related Notice
Department/Ind. Agency
VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier
VETERANS AFFAIRS, DEPARTMENT OF
Office
257-NETWORK CONTRACT OFFICE 17 (36C257)
Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information
  • Contract Opportunity Type: Presolicitation (Original)
  • Original Published Date: Jul 29, 2025 01:27 pm CDT
  • Original Response Date: Aug 12, 2025 10:00 am CDT
  • Inactive Policy: Manual
  • Original Inactive Date: Aug 26, 2025
  • Initiative:
    • None
Classification
  • Original Set Aside: Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
  • Product Service Code: Y1DZ - CONSTRUCTION OF OTHER HOSPITAL BUILDINGS
  • NAICS Code:
    • 238220 - Plumbing, Heating, and Air-Conditioning Contractors
  • Place of Performance:
    North Texas VHCs - Garland Garland , 75042
Description
THIS IS A PRESOLICIATION NOTICE A REQUEST FOR PROPOSALS (RFP) WILL BE POSTED ON OR ABOUT JULY 14, 2025
The North Texas VA Health Care System in Bonham Texas currently has a requirement to Replace Condensate Return Units & Pumps
36C25725R0084
The project will include the contractor to provide Supervision, Labor, Parts & Material on replacements of the Condensate Return Units located at the VAMC Garland VA facility. To include a total of (5) five-Duplex Condensate Return Units and Pumps sized to existing units or better. Units shall be able to withstand High Temp heating water seal ranges from 209° minimum up to 250°. Units shall come with Factory Mounted Control Panels with High Level Alarms, Discharge Pressure Gauges, Dial Thermometers, Centrifugal Pumps, Float Switches & Water Level Gauges. Electrical panels with high & low alarms. Connections from existing unit flange to flange connections no less than 3,000 psi unions connections and scheduled 80 or better related pipe. Electrical connections are required by installation from the contractor. Related plumbing shall be required. Insulation required per contract for all related exposed areas related to installation with associated material & related parts.
The NAICS code for this procurement is 238220 with a small business size standard of $45M. The magnitude of this project is between $100,000 and $250,000 per FAR 36.204(c).
This project will be 100% set-aside for Service-Disabled Veteran-Owned Small Businesses, as stated below.
The POC for this project will be Rhonda Richardson. She can be contacted by email at RHONDA.RICHARDSON5@va.gov.
Important Notice: Apparent successful offeror must apply for and receive verification from SBA of SDVOSB status in accordance with 38 CFR Part 74 and VAAR 819.7 by submission of documentation of Veteran status, ownership, and control sufficient to establish appropriate status. Offerors must be both VISIBLE and VERIFIED by SBA.GOV prior to submission of offer. Failure to be both VERIFIED by SBA and VISIBLE on the Dynamic Small Business Search (DSBS.sba.gov) prior to submission of the offer, will result in the offeror s proposal being deemed non-responsive. All offerors are urged to contact SBA.GOV and submit the required documents to obtain verification of their SDVOSB status if they have not already done so.
Attachments/Links
Contact Information
Contracting Office Address
  • 5441 Babcock Road Suite 302
  • San Antonio , TX 78240
  • USA
Primary Point of Contact
Secondary Point of Contact


History
  • Jul 29, 2025 01:27 pm CDTPresolicitation (Original)

Related Document

Aug 12, 2025[Solicitation (Original)] Y1DZ-- 549-25-178 Replace Condensate Return Units & Pumps at Garland VA
Sep 2, 2025[Solicitation (Updated)] Y1DZ-- 549-25-178 Replace Condensate Return Units & Pumps at Garland VA
Daily notification on new contract opportunities

With GovernmentContracts, you can:

  • Find more opportunities and win more business
  • Receive daily alerts for all new bid opportunities
  • Get contract opportunities matched to your business
ONE WEEK FREE TRIAL
* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.