F108--Mold Analysis, Abatement, & Remediation Bldg. 14 BROOKLYN VAMC

Location: Federal
Posted: Feb 28, 2025
Due: Mar 27, 2025
Agency: VETERANS AFFAIRS, DEPARTMENT OF
Type of Government: Federal
Category:
  • F - Natural Resources and Conservation Services
Solicitation No: 36C24225B0017
Publication URL: To access bid details, please log in.
Follow
F108--Mold Analysis, Abatement, & Remediation Bldg. 14 BROOKLYN VAMC
Active
Contract Opportunity
Notice ID
36C24225B0017
Related Notice
36C24225B0017
Department/Ind. Agency
VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier
VETERANS AFFAIRS, DEPARTMENT OF
Office
242-NETWORK CONTRACT OFFICE 02 (36C242)
Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information
  • Contract Opportunity Type: Solicitation (Original)
  • Original Published Date: Feb 28, 2025 04:27 pm EST
  • Original Date Offers Due: Mar 27, 2025 11:00 am EDT
  • Inactive Policy: Manual
  • Original Inactive Date: Jul 04, 2025
  • Initiative:
    • None
Classification
  • Original Set Aside:
  • Product Service Code: F108 - ENVIRONMENTAL SYSTEMS PROTECTION- ENVIRONMENTAL REMEDIATION
  • NAICS Code:
    • 238210 - Electrical Contractors and Other Wiring Installation Contractors
  • Place of Performance:
Description

Page 2 of 2

CONSTRUCTION SCOPE OF WORK
EHRM NEXTGEN WIFI UPGRADES

PROJECT NO: 630-22-704
PROJECT NAME: EHRM NextGen WiFi Upgrades New York Harbor Healthcare System
1. GENERAL INTENT:

The Contractor shall furnish all labor, tools, materials and equipment to support installation of new WiFi Access Points at the Margaret Cochran Corbin VA Medical center in Manhattan 423 East 23rd St. New York, NY and at the St Albans medical center located at 179-00 Linden Blvd Queens, NY. Please note that the scope of this work is limited and specifically as listed below.

2. STATEMENT OF WORK:

Provide and install conduit, raceways, horizontal and vertical penetrations, and fire stopping to support NextGen WiFi installation at the New York Harbor healthcare system as shown and described in the project drawings and specifications. A list of required access point locations requiring conduits and/or penetrations are provided as SOW Attachment 1. SOW Attachment 2 and 2A include access point floor plans of the two medical centers.

Work shall include:

1. Installation of 180 WiFi Access Points (WAP s). WAP s will be provided by the VA, but the mounting brackets shall be provided by the Contractor. (154 access points are located at Manhattan campus and 26 at St Albans campus.)

2. Supply and Installation of 600 linear feet of EMT conduit, including junction boxes, pull cords, and fire stopping, throughout the Medical Centers. Existing conduit paths between floors/IT rooms will not have the capacity for more cable and new conduit paths will need to be created. Most AP s will be wired to a telecommunication room on same floor however Manhattan Building 2 and 3, and St. Albans Buildings 89 and 85_86 are exceptions requiring vertical conduit pathways- see attached drawings for details.

Conduit sleeves are required from WAP room locations to corridors. Once in corridor it is expected that cable will travel in existing cable trays. Where cable tray is not present, J-Hooks shall be utilized if existing J-Hooks have not been previously installed or are at capacity. Include pricing for supply and installation of (400) J Hooks. Turnover any unused J-Hooks to VA at end of job.

Where the cables passes through a smoke zone as seen in drawings as a corridor door, provide and install a smoke rated sleeve e.g. EZ Path 44NEZ or equal where existing sleeves don t exist. Also utilize the smoke rated sleeve for all penetrations into telecommunication rooms. Assume Qty (94) to be required, turn over any unused sleeves to VA at end of job.

3. Installation of approximately 36,000 linear feet of CAT 6A cable from APs to nearest IT rooms and terminating in a patch panel. WAP locations and IT room locations are shown on drawings.

4. Infection Control Procedures.
When removing ceiling tiles in corridors and inpatient sleeping rooms, all work must be done within mobile HEPA containment containers. Contractor will be responsible for providing , renting if needed, and transporting such containers. A minimum of two HEPA carts will be required while pulling cable.

All work will be performed during business hours, Monday thru Friday, 8 AM to 4:30 PM.

3. PERIOD OF PERFORMANCE:

3.1 Work timelines and completion progress shall be communicated to the COR for tracking purposes.Â
Â
3.2 Work described in Section 2 shall be completed within 10 weeks of NTP

4. REFERENCES:

4.1 VA OEHRM Site Infrastructure and End User Device (EUD) Requirements Version 2.0Â (Attachment 3).
4.2 Infrastructure Standard for Telecommunication Spaces Vers 3.1 https://www.cfm.va.gov/til/dguide/OIT-InfrastrucStdTelecomSpaces.pdf
5. SPECIFICATIONS:

DIVISION 01 - GENERAL REQUIREMENTS
01 00 00 General Requirements
01 32 16.15 Project Schedule
01 33 23 Shop Drawings, Product Data, and Samples
01 35 26 Safety Requirements
01 74 19 Construction Waste Management

DIVISION 07 THERMAL AND MOISTURE PROTECTION
07 84 00 Firestopping

DIVISION 27 COMMUNICATIONS
27 05 11 Requirements for Communications Installations
27 05 33 Raceways and Boxes for Communications Systems
27 15 00 Communications Structured Cabling

6. SUBMITTALS:

The contractor shall submit the following submittals for review:
Product data and sample of conduit or raceway , smoke rated sleeves and Cat 6A cable.
As-built drawings for all data locations and labels. The Contractor shall provide the central drawing set to the Owner at the end of the project. The marked-up drawing set will accurately depict the as-built status of the system.
6. ATTACHMENTS:

6.1 Attachment 1: List of Access Point locations and site prep requirements.
6.2 Attachment 2 and 2A: NextGen WiFi Access Point location drawings
6.3 Attachment 3: VA OEHRM Site Infrastructure and End User Device (EUD) Requirements Version 2.0
6.4 Attachment 4: Sensitive Infrastructure Data Classification Memo
6.5 Attachment 5: Seasonal Influenza with Vaccines
6.6 Attachment 6: Specifications

The above paragraphs constitute a basic outline of the work to be accomplished and in no way comprises all the details for this project. Contractor shall refer to drawings and specifications for comprehensive construction requirements.

End of SOW
Attachments/Links
Contact Information
Contracting Office Address
  • 113 HOLLAND AVE
  • ALBANY , NY 12208
  • USA
Primary Point of Contact
Secondary Point of Contact


History

Related Document

Feb 4, 2025[Presolicitation (Original)] 7E21--NextGen Wi-Fi Upgrades Manhattan and St. Albans VAMC
Mar 7, 2025[Solicitation (Updated)] 36C24225B0017 NextGen WiFi Upgrades Manhattan, St. Albans
Mar 25, 2025[Solicitation (Updated)] 7E21--NextGen Wi-Fi Upgrades Manhattan and St. Albans VAMC
Daily notification on new contract opportunities

With GovernmentContracts, you can:

  • Find more opportunities and win more business
  • Receive daily alerts for all new bid opportunities
  • Get contract opportunities matched to your business
ONE WEEK FREE TRIAL
* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.