The ERDC needs a total of QTY: 6 masonry target walls constructed at the Big Black Test Site with options for additional walls exercised throughout the next three years.
1.0 The contractor will construct:
2.0 The contractor will build as prescribed below in the section entitled Masonry Building Requirements. For the initial award and all the options that are exercised, the contractor will also maintain accurate building logs for each wall and provide all necessary equipment to perform the work. The ERDC will provide the necessary quantity of masonry bricks/blocks as applicable, mortar, sand, and rebar.
ADDITIONAL OPTIONS:
OPTION 1: QTY: 3 - 12” thick triple wythe brick wall sections inside steel wall frames. Material and build details are listed in Section 2.1.
OPTION 2: QTY: 3 - 12” thick triple wythe brick wall sections inside steel wall frames. Material and build details are listed in Section 2.1.
OPTION 3: QTY: 3 - 12” thick triple wythe brick wall sections inside steel wall frames. Material and build details are listed in Section 2.1.
OPTION 4: QTY: 3 - 12” thick triple wythe brick wall sections inside steel wall frames. Material and build details are listed in Section 2.1.
OPTION 5: QTY: 3 - 8” thick lightly reinforced CMU wall sections inside steel wall frames. Material and build details are listed in Section 2.2.
OPTION 6: QTY: 3 - 8” thick lightly reinforced CMU wall sections inside steel wall frames. Material and build details are listed in Section 2.2.
OPTION 7: QTY: 3 - 8” thick lightly reinforced CMU wall sections inside steel wall frames. Material and build details are listed in Section 2.2.
OPTION 8: QTY: 3 - 8” thick heavily reinforced CMU wall sections inside steel wall frames. Material and build details are listed in Section 2.2
OPTION 9: QTY: 3 - 8” thick heavily reinforced CMU wall sections inside steel wall frames. Material and build details are listed in Section 2.2
OPTION 10: QTY: 3 - 8” thick heavily reinforced CMU wall sections inside steel wall frames. Material and build details are listed in Section 2.2

With GovernmentContracts, you can:
Sole Source 9734 - Physician Scheduling Platform Renewal - Family Medicine (QGenda)
University of Mississippi Medical Center
Bid Due: 6/12/2026
Submission Deadline Tue June 16th, 2026 at 8:00 am SSN 256-099 Comsol Multiphysics
Mississippi State University
Bid Due: 6/16/2026
Submission Deadline Wed June 17th, 2026 at 2:00 pm Bid MSU2026080 Access Control
Mississippi State University
Bid Due: 6/17/2026
Submission Deadline Tue June 16th, 2026 at 8:00 am SSN 256-101 ACI will
Mississippi State University
Bid Due: 6/16/2026