The ERDC needs a total of QTY: 6 masonry target walls constructed at the Big Black Test Site with options for additional walls exercised throughout the next three years.
1.0 The contractor will construct:
2.0 The contractor will build as prescribed below in the section entitled Masonry Building Requirements. For the initial award and all the options that are exercised, the contractor will also maintain accurate building logs for each wall and provide all necessary equipment to perform the work. The ERDC will provide the necessary quantity of masonry bricks/blocks as applicable, mortar, sand, and rebar.
ADDITIONAL OPTIONS:
OPTION 1: QTY: 3 - 12” thick triple wythe brick wall sections inside steel wall frames. Material and build details are listed in Section 2.1.
OPTION 2: QTY: 3 - 12” thick triple wythe brick wall sections inside steel wall frames. Material and build details are listed in Section 2.1.
OPTION 3: QTY: 3 - 12” thick triple wythe brick wall sections inside steel wall frames. Material and build details are listed in Section 2.1.
OPTION 4: QTY: 3 - 12” thick triple wythe brick wall sections inside steel wall frames. Material and build details are listed in Section 2.1.
OPTION 5: QTY: 3 - 8” thick lightly reinforced CMU wall sections inside steel wall frames. Material and build details are listed in Section 2.2.
OPTION 6: QTY: 3 - 8” thick lightly reinforced CMU wall sections inside steel wall frames. Material and build details are listed in Section 2.2.
OPTION 7: QTY: 3 - 8” thick lightly reinforced CMU wall sections inside steel wall frames. Material and build details are listed in Section 2.2.
OPTION 8: QTY: 3 - 8” thick heavily reinforced CMU wall sections inside steel wall frames. Material and build details are listed in Section 2.2
OPTION 9: QTY: 3 - 8” thick heavily reinforced CMU wall sections inside steel wall frames. Material and build details are listed in Section 2.2
OPTION 10: QTY: 3 - 8” thick heavily reinforced CMU wall sections inside steel wall frames. Material and build details are listed in Section 2.2

With GovernmentContracts, you can:
Bid Name Type of Bid Bid No. Department Bid Advertising Dates Bid Closing
Jackson State University
Bid Due: 9/23/2026
Procurement Details Smart Number 1731-27-R-PREQ-00004 Advertised Date 08/19/2026 12:00 AM RFx # 3200001531
State Government of Mississippi
Bid Due: 9/28/2026
Solicitation Title Deadline Date Deadline Time Documents Types Bid File - 1294 Campus-wide
University of Mississippi.
Bid Due: 9/17/2026
Follow FY 26 - FY 31 Unaccompanied Housing Wi-Fi Active Contract Opportunity Notice
DEPT OF DEFENSE
Bid Due: 9/17/2026