| Location: | Mississippi |
|---|---|
| Posted: | Sep 29, 2025 |
| Agency: | DEPT OF DEFENSE |
| Type of Contract: | Awards |
| Type of Government: | Federal |
| Category: |
|
| Solicitation No: | W912HZ25CA022 |
| Publication URL: | To access bid details, please log in. |
The ERDC needs a total of QTY: 6 masonry target walls constructed at the Big Black Test Site with options for additional walls exercised throughout the next three years.
1.0 The contractor will construct:
2.0 The contractor will build as prescribed below in the section entitled Masonry Building Requirements. For the initial award and all the options that are exercised, the contractor will also maintain accurate building logs for each wall and provide all necessary equipment to perform the work. The ERDC will provide the necessary quantity of masonry bricks/blocks as applicable, mortar, sand, and rebar.
ADDITIONAL OPTIONS:
OPTION 1: QTY: 3 - 12” thick triple wythe brick wall sections inside steel wall frames. Material and build details are listed in Section 2.1.
OPTION 2: QTY: 3 - 12” thick triple wythe brick wall sections inside steel wall frames. Material and build details are listed in Section 2.1.
OPTION 3: QTY: 3 - 12” thick triple wythe brick wall sections inside steel wall frames. Material and build details are listed in Section 2.1.
OPTION 4: QTY: 3 - 12” thick triple wythe brick wall sections inside steel wall frames. Material and build details are listed in Section 2.1.
OPTION 5: QTY: 3 - 8” thick lightly reinforced CMU wall sections inside steel wall frames. Material and build details are listed in Section 2.2.
OPTION 6: QTY: 3 - 8” thick lightly reinforced CMU wall sections inside steel wall frames. Material and build details are listed in Section 2.2.
OPTION 7: QTY: 3 - 8” thick lightly reinforced CMU wall sections inside steel wall frames. Material and build details are listed in Section 2.2.
OPTION 8: QTY: 3 - 8” thick heavily reinforced CMU wall sections inside steel wall frames. Material and build details are listed in Section 2.2
OPTION 9: QTY: 3 - 8” thick heavily reinforced CMU wall sections inside steel wall frames. Material and build details are listed in Section 2.2
OPTION 10: QTY: 3 - 8” thick heavily reinforced CMU wall sections inside steel wall frames. Material and build details are listed in Section 2.2