8145--HAZARDOUS WASTE STORAGE UNIT RFI

Location: West Virginia
Posted: Oct 8, 2025
Due: Oct 17, 2025
Agency: VETERANS AFFAIRS, DEPARTMENT OF
Type of Government: Federal
Category:
  • 81 - Containers, Packaging, and Packing Supplies
Solicitation No: 36C24526Q0051
Publication URL: To access bid details, please log in.
Follow
8145--HAZARDOUS WASTE STORAGE UNIT RFI
Active
Contract Opportunity
Notice ID
36C24526Q0051
Related Notice
Department/Ind. Agency
VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier
VETERANS AFFAIRS, DEPARTMENT OF
Office
245-NETWORK CONTRACT OFFICE 5 (36C245)
Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information
  • Contract Opportunity Type: Sources Sought (Original)
  • Original Published Date: Oct 07, 2025 01:15 pm EDT
  • Original Response Date: Oct 17, 2025 12:00 pm EDT
  • Inactive Policy: Manual
  • Original Inactive Date: Oct 27, 2025
  • Initiative:
    • None
Classification
  • Original Set Aside:
  • Product Service Code: 8145 - SPECIALIZED SHIPPING AND STORAGE CONTAINERS
  • NAICS Code:
    • 332439 - Other Metal Container Manufacturing
  • Place of Performance:
    Department of Veterans Affairs Clarksburg VAMC Clarksburg , WV 26301
    USA
Description
Page 3 of 3
THIS REQUEST FOR INFORMATION IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY AND DOES NOT CONSTITUTE A SOLICITATION.
This is a Request for Information (RFI)/Sources Sought Notice (SS), this is not a Request for Quotes (RFQ) or Request for Proposals (RFP). No formal solicitation document exists at this present time. This is not a solicitation announcement. The purpose of this Sources Sought notice NAICS 332999 Fabricated metal building PSC 8145 Specialized metal containers NAIC size standard of 750 employees for the VAMC.

Responses to this Sources Sought notice will be utilized by the Government to make appropriate acquisition decisions. After review of the responses to this Sources Sought notice, a solicitation announcement may or may not be published in SEWP, SAM.gov (SAM) or GSA ebuy.

REQUESTED INFORMATION

If you are interested and capable, and can provide the required product, please provide the requested information for questions 1-15 as indicated below:

Is this service/product priced on vendor s GSA/SEWP/FSS/NAC/SAC contract? Yes/No
If yes, provide vendor contract number?
Is this service/product open market pricing? Yes/No
Is open market priced online? Yes/No
Provide vendor s business size status and representations NAIC and PSC code?
Provide interested vendor s name, address, telephone, and SAM UEI.
Does vendor have capability, product, and interest for end item product requirement? Yes/No
Provide product end item; product name/model/ product brochure/ specification sheet/warranty/life expectancy/maintenance requirements information.
Where is end item product place of manufacturer?
Is interested vendor (which BS) authorized distributor of domestic end item product?
Is interested vendor (which BS) manufacturer domestic end item product?
Is interested vendor (which BS) manufacturer of nondomestic end item product?
Is interested vendor (which BS) authorized distributor of nondomestic end item product?
Provide a copy authorized distributor letter if vendor is not the manufacturer.
Does vendor have item prefab in stock and ready to install

SOW
GENERAL INFORMATION
SALIENT CHARCTERISTICS
size dimensions no larger than 8 3 H x 14 W x 8 D
staff entry 60"W x 80"H Double Door with 36" Active Leaf
Sump Capacity: 24 55 gallon drums
4 Hour Fire Rated, Fire Rated Walls are tested to meet ASTM E119, and FM approved for 4 Hours, Fire Rated Roof tested to meet ASTM E119 and FM Approved for 3 Hours.
Main breaker OP-100A Load Center 12 SPACE 100A NEMA 3R 120/240V to meet power requirements for container
Pre-site/install/delivery/set up/Contactor/ grounding kit/ leveling/ ramp install/tie down/Electrical Hookup to Energize and De-Energize Equipment when Dry Chemical Suppression System installed
Explosion Proof Air Conditioner with Color Coded Thermostat Class 1, Division 2 208 Volt 15,700Btu, 230 Volt 15,700Btu (ORD)
R11 Insulation Walls, Ceiling and DLC
Explosion Proof Exhaust System-335 CFM w/indicator light
Explosion Proof Emergency Shut Off Switch for Exhaust System
LED Explosion Proof Light Fixture with Light Switch Class 1 Division 2
ABC Dry Chemical Fire Suppression System with Audiable Alarm
14"W SHELVES WITH 2" LIP SIDES (Priced Per Linear Foot)
at least 3 tiers footage length 85% shelving to fit along back wall, 65% total each left wall and right walls
6 ACHs
at least one adjustable 18 W x 18H Vent with Insulated Cover
no larger than 52"W x 72"L Perforated Steel Ramp with Skid-Resistant Finish to meet container ground height.
Must be moveable metal grading full length flooring with spill containment with drain.

NOTES

All Capability Statements/Responses to this Sources Sought notice shall be submitted via email stephanie.henderson3@va.gov Telephone, Fax, or any other form of communication inquiries will not be reviewed or accepted in response to this Sources Sought notice. Responses to this Sources Sought notice must be received no later than 10/17/25 at 1:00 p.m. (Eastern Standard Time). This Sources Sought notice is to assist the VA in determines sources only. A solicitation is not currently available. If a solicitation is issued, it may or may not be announced at a later date, and all interested parties shall respond to that solicitation announcement separately from the responses to this Sources Sought notice.


DISCLAIMER

This Request for Information (RFI) is issued for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked a proprietary will be handled accordingly in accordance with (IAW) Federal Acquisition Regulation (FAR) 15.201(e), RFIs may be used when the Government does not presently intend to award a contract, but wants to obtain price, delivery, other market information, or capabilities for planning purposes. Responses to these notices are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses incurred associated with responding to this RFI.

End of Notice
Attachments/Links
Contact Information
Contracting Office Address
  • 8849 International Drive Suite 215
  • LINTHICUM , MD 21090
  • USA
Primary Point of Contact
Secondary Point of Contact


History
  • Oct 07, 2025 01:15 pm EDTSources Sought (Original)
Daily notification on new contract opportunities

With GovernmentContracts, you can:

  • Find more opportunities and win more business
  • Receive daily alerts for all new bid opportunities
  • Get contract opportunities matched to your business
ONE WEEK FREE TRIAL
* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.