Bldg 840 Chiller Replacement

Location: Idaho
Posted: Apr 21, 2026
Due: May 6, 2026
Agency: DEPT OF DEFENSE
Type of Government: Federal
Category:
  • 41 - Refrigeration, Air Conditioning and Air Circulating Equip.
Solicitation No: FA489726Q0011
Publication URL: To access bid details, please log in.
Follow
Bldg 840 Chiller Replacement
Active
Contract Opportunity
Notice ID
FA489726Q0011
Related Notice
Department/Ind. Agency
DEPT OF DEFENSE
Sub-tier
DEPT OF THE AIR FORCE
Major Command
AIR COMBAT COMMAND
Office
FA4897 366 CONS PKP
Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information
  • Contract Opportunity Type: Sources Sought (Original)
  • Original Published Date: Apr 21, 2026 09:34 am MDT
  • Original Response Date: May 06, 2026 03:00 pm MDT
  • Inactive Policy: 15 days after response date
  • Original Inactive Date: May 21, 2026
  • Initiative:
    • None
Classification
  • Original Set Aside: Total Small Business Set-Aside (FAR 19.5)
  • Product Service Code: 4120 - AIR CONDITIONING EQUIPMENT
  • NAICS Code:
    • 238220 - Plumbing, Heating, and Air-Conditioning Contractors
  • Place of Performance:
    Mountain Home AFB , ID 83648
    USA
Description

This post is for market research purposes only. THIS IS NOT A SOLICITATION FOR PROPOSALS AND NO CONTRACT WILL BE AWARDED FROM THIS SOURCES SOUGHT. No reimbursement will be made for any costs associated with providing information in response to this synopsis or any follow up information requests.



MHAFB is gauging the interest of total small business set aside with further potential set aside into socioeconomic categorys.



MHAFB has a requirement for design-build construction services to replace the existing Chiller and install a Buffer tank that requires a new concrete pad at Bldg 840. The following work shall be IAW with manufacture instructions in conjunction with the SOW. The following requirement will include, but not limited to, the following:



1. Dispose of the old unit and any waste materials in accordance with all environmental regulations. Base HVAC shall be given an opportunity to salvage components such as condenser motors and control boards if it does not cause a delay.



2. Prepare the existing concrete pad/structural base for the new chiller installation.



3. Install vibration isolation pads/springs as specified.



4. Install all required valves, strainers, flow switches, and instrumentation.



5. Install 5" flanged piping to tie in 500-gallon carbon steel buffer tank into chilled water system return line. Must have 2" urethane insulation with aluminum jacketing.



6. Provide BACnet integration with system chiller. (Chiller interface card provided with equipment)



7. Perform manufacturer-certified startup procedures and ensure functional system operation.



All IAW the statement of work (SOW).



The magnitude of this project is between $100,000 and $250,000.



In order to reduce chances of missed emails, the Subject line shall be "Bldg 840 Chiller Replacement Sources Sought Response"



Each company’s response to this Sources Sought shall be a maximum of 3 pages and shall include the following information:




  • Company name

  • CAGE code

  • Address

  • Point of Contact

  • Phone Number

  • E-mail address

  • Company's Small business category (Small Business, Woman-Owned Small Business, Small Disadvantaged Business [SDB] to include the 8(a) Program, Historically Underutilized Business Zones [HUBZone], Service- Disabled Veteran Owned Small Business [SDVOSB]).

  • A brief statement of the company's interest in bidding on the project as well as details of the company's capability to perform a contract of this type, magnitude, and complexity




Attachments/Links
Contact Information
Contracting Office Address
  • ADMIN ONLY NO REQTN CP 208 828 4658 366 GUNFIGHTER AVE STE 2102
  • MOUNTAIN HOME AFB , ID 83648-5296
  • USA
Primary Point of Contact
Secondary Point of Contact
History
  • Apr 21, 2026 09:34 am MDTSources Sought (Original)

Related Document

May 20, 2026[Solicitation (Updated)] Bldg 840 Chiller Replacement
May 23, 2026[Solicitation (Updated)] Bldg 840 Chiller Replacement
Daily notification on new contract opportunities

With GovernmentContracts, you can:

  • Find more opportunities and win more business
  • Receive daily alerts for all new bid opportunities
  • Get contract opportunities matched to your business
ONE WEEK FREE TRIAL

See also

...chain to complete design, build, commissioning, operation, and decommissioning, as appropriate...) is the ...

ENERGY, DEPARTMENT OF

Bid Due: 6/19/2026

* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.