RIA B390 Emergency Exit Stairs - Notice of Intent - Sole Source - Fire Alarm System

Agency: DEPT OF DEFENSE
State: Illinois
Type of Government: Federal
Category:
  • Y - Construction of Structures and Facilities
Posted: Apr 4, 2024
Due: Apr 19, 2024
Solicitation No: RIA_B390_Stairs_NOI_FireAlarm
Publication URL: To access bid details, please log in.
Follow
RIA B390 Emergency Exit Stairs - Notice of Intent - Sole Source - Fire Alarm System
Active
Contract Opportunity
Notice ID
RIA_B390_Stairs_NOI_FireAlarm
Related Notice
Department/Ind. Agency
DEPT OF DEFENSE
Sub-tier
DEPT OF THE ARMY
Major Command
USACE
Sub Command
LRD
Office
W072 ENDIST LOUISVILLE
General Information
  • Contract Opportunity Type: Special Notice (Original)
  • All Dates/Times are: (UTC-04:00) EASTERN STANDARD TIME, NEW YORK, USA
  • Original Published Date: Apr 04, 2024 04:12 pm EDT
  • Original Response Date: Apr 19, 2024 02:00 pm EDT
  • Inactive Policy: 15 days after response date
  • Original Inactive Date: May 04, 2024
  • Initiative:
    • None
Classification
  • Original Set Aside:
  • Product Service Code: Y1JZ - CONSTRUCTION OF MISCELLANEOUS BUILDINGS
  • NAICS Code:
    • 236220 - Commercial and Institutional Building Construction
  • Place of Performance:
    Rock Island , IL
    USA
Description

The U.S. Army Corps of Engineers (UACE) Louisville District will be soliciting proposals for the Building 390 Emergency Exit Stair Towers project at Rock Island Arsenal (RIA), Illinois. As part of the construction contract solicitation, the USACE intends to include the followign sole source requirement:



Fire Alarm System: The existing RIA facilities fire alarm system is a JCI system (JCI model 4001 Fire Alarm Control panel and JCI model 4009 Notification Extender Panel), which is a proprietary system. The B390 Emergency Exit Stair Towers project is to construct four separate emergency exits attached to each wing of B390, and the project will include necessary fire alarm and mass notification measures which must be integrated with the fire alarm/mass notification system of the existing facility. Construction must ensure the facility and the users are protected by code-compliant systems. Illinois requires integration of the fire alarm system with the existing RIA fire alarm system. Per specification section 28 31 76 para. 2.1.5, each control unit shall provide power, supervision, control, and logic for the entire system, utilizing solid state, modular components, internally mounted and arranged for easy access. All building security and alarm systems are a standard, uniform system throughout the entire facility. These systems utilize proprietary software to control and monitor each system and communicate with various components.


Attachments/Links
Contact Information
Contracting Office Address
  • KO CONTRACTING DIVISION 600 DR MARTIN LUTHER KING JR PL
  • LOUISVILLE , KY 40202-2230
  • USA
Primary Point of Contact
Secondary Point of Contact


History
  • Apr 04, 2024 04:12 pm EDTSpecial Notice (Original)
Daily notification on new contract opportunities

With GovernmentContracts, you can:

  • Find more opportunities and win more business
  • Receive daily alerts for all new bid opportunities
  • Get contract opportunities matched to your business
ONE WEEK FREE TRIAL

See also

...Follow Access Control Upgrades Active Contract Opportunity Notice ID 832468814 Related Notice..., and ...

DEPT OF DEFENSE

Bid Due: 5/15/2024

...include transportation, overhead, bonding costs, insurance, safety oversight, quality control... is required to ...

ENERGY, DEPARTMENT OF

Bid Due: 5/10/2024

* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only as a convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.